• Title/Summary/Keyword: transmission distribution

Search Result 1,550, Processing Time 0.032 seconds

A Study on the Cancellation of Harmonic Noise for the Improvement of Data Transmission Characteristics in Power Line Channel (전력선 채널의 데이터 전송 특성 개선을 위한 고조파 잡음 제거에 관한 연구)

  • 박준현;김남용;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.3
    • /
    • pp.259-269
    • /
    • 1991
  • In this paper, power line harmonic noise which is the most serious problem in the secondary power distribution line is eliminated and analyzed using adaptive noise cancellers with two adaptive algorithms, LMS and individual tap LMS(ITLMS) algorithm. To testify the improvement of data transmission characteristics made by the adaptive filter with two adaptive algorithms, BER was measured in DS spread spectrum communication system including the noise canceller.

  • PDF

Evaluation of Jacket Compounds for Underground Distribution Power Cables (지중 배전케이블용 자켓 컴파운드의 특성평가)

  • 한재홍;송일근;김동명;이재봉;정창수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.8
    • /
    • pp.687-694
    • /
    • 2002
  • In order to replace the jacket material for URD power cables, the 6 kinds of polyethylene compounds were manufactured and evaluated. The characteristics of the compounds were investigated by water vapor transmission (WVT) test, thermal and mechanical test. In WVT test, all the polyethylene compounds showed the superior water resistance to conventional PVC. The molecular structure and density of polyethylene play an important role in WVT. Also, the polyethylene compounds showed the suitable characteristics in thermal and mechanical test. Especially, the linear polyethylene compounds showed the superior characteristics to LDPE ones. Due to the fillers in compounds, the abrasion resistance was decreased and the cut-through resistance was increased. From this study, it can be considered that the polyethylene compounds may be suitable to jacket material for URD power cables.

Analysis of the lightning characteristics by the Lightning DB in KOREA (낙뢰위치표정시스템의 낙뢰 DB를 이용한 한반도 뇌격 특이특성 분석)

  • Woo, J.W.;Kwak, J.S.;Shim, E.B.;Lee, G.W.;Kim, K.W.;Kim, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1658-1660
    • /
    • 2001
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

IGA-Based Transmission Loss Minmization considering A New Equality Constraint (새로운 등호제약조건을 고려한 개선된 유전알고리즘 기반의 송전손실 최소화)

  • Chae, Myung-Suk;Lee, Myung-Hwan;Kim, Byung-Seop;Shin, Joong-Rin;Yim, Han-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.104-106
    • /
    • 2000
  • This paper presents an algorithm for optimal reactive power dispatch problem based on Improved Genetic Algorithm(IGA). Optimal Reactive Power Dispatch (ORPD) is particularized to the minimization of transmission line losses by suitable selection of generator reactive power outputs and transformer tap setting. For the objective, in this paper, Loss Re-Distribution Algorithm(LRDA) is new applied to the equality constraint of ORPD. The proposed method has been evaluated on the IEEE 30 bus system. Results of the application of the method are compared with a base case.

  • PDF

A Study on Algorism for Evaluating Power Wheeling Effects using Monte-Carlo Simulation (Monte Carlo Simulation을 이용한 Power Wheeling 영향평가 알고리즘에 관한 연구)

  • Cho, Jae-Han;Nam, Kwang-Woo;Kim, Yong-Ha;Lee, Buhm;Choi, Sang-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1111-1113
    • /
    • 1999
  • This paper presents a algorism for evaluating contingency case power wheeling effects using Monte-Carlo simulation The effects of wheeling on generating cost, transmission losses, and system security are considered. For a specific operating condition, the effects are quantified by the sensitivity of specific quantities of interest with respect to wheeling level. This model is utilized within a Monte-Carlo simulation to calculate probability distribution functions of the incremental effects of wheeling on operating cost, transmission losses, and system security. The model and solution methods are applied on a IEEE RTS-96 system power system and the results are presented.

  • PDF

Analysis of scattering fields by conductors with arbitrary cross-section in parallel-plate waveguide (평행판 도파관내의 산란 도체에 의한 산란파 해석)

  • 정봉식;김현정;김응수;조규완
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.12
    • /
    • pp.65-73
    • /
    • 1995
  • In this paper, new algorithm which calculates transmission coefficient of electromagnetic wave by numerical analysis of scattered field by conductors with arbitrary cross-sections in parallel-plate waveguide is proposed. Proposed algorithm assumes magnetic current distribution on the boundary of scattering conductors, and applies Image theorem to perfect conductor surfaces of parallel-plate waveguide. Integral equations for fictitious magnetic currents on conducting boundary are set up. Magnetic current distributions on conducting boundary are expanded as exponential basis function, and using Galerkin method matrix equations are set wp. To compute matrix elements this method utilizes Fourier transform which is faster than numerical integration. Finally, frequency and incidence-angle characteristic of transmission coefficient are calculated and compared with experimental results.

  • PDF

Analysis of Lightning observed by KEPCO Lightning Detection Network (한전낙뢰관측 시스템 KLDNet의 낙뢰관측 결과 분석)

  • Kwak, J.S.;Park, M.H.;Jeong, M.J.;Ju, H.J.;Oh, S.Y.;Kim, H.S.;Woo, J.W.;Han, K.S.;Goo, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.398-399
    • /
    • 2015
  • The fault level of power transmission lines caused by natural disaster such as lightning and rainstorm has been on the rise. Especially, the cause of lightning stokes is large part of transmission faults. In order to reduce the lightning failures, it is necessary to measure and analyze the lightning characteristics. This paper deals with observation of the lightning strokes by KEPCO Lightning Detection Network(KLDNet) and analysis including lightning density, multiplicity and amplitude distribution.

  • PDF

Analysis of LPATS-III Error Level and the lightning characteristics in KOREA (LPATS-III의 오차검토 및 한반도 낙뢰발생빈도 분석결과)

  • Woo, J.W.;Shim, E.B.;Kwon, D.J.;Choi, Y.M.;Lee, S.J.;Kim, K.W.;Lee, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1772-1774
    • /
    • 2002
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. To study the basic research of the lightning parameters for power system operation, LPATS-III (Lightning Positioning and Tracking System) has been introduced since 1995 in Korea. This paper describes the inspection result about location information error and the statistical distribution of lightning current.

  • PDF

A Review of Methods for Calculation of Induced Voltage to a Communication Line from Distribution Power Line (배전선로가 초고속통신망에 미치는 유도장해 요소 분석)

  • Lim, Yong-Hun;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1956-1958
    • /
    • 2002
  • This paper reviews the calculation of induced voltage to a communication line from Power Transmission Line. Power lines, both overhead and underground, often run parallel to weak current lines, such as telecommunication, signal or data transmission systems or protection circuits. The coexistence of both systems in parallel over long lengths is accompanied by the possible induction of significant longitudinal voltage in the weak current line. In order to evaluate a precise induced voltage, this paper indicated problem about coefficient and numerical formula and present some induced voltage production technology standard application.

  • PDF

Monotonic and Parallelizable Algorithm for Simultaneous Reconstruction of Activity/Attenuation using Emission data in PET

  • Kim, Seung-Gu
    • Communications for Statistical Applications and Methods
    • /
    • v.8 no.1
    • /
    • pp.299-309
    • /
    • 2001
  • In PET(Positron Emission Tomography), it is necessary to use transmission scan data in order to estimate the attenuation map. Recently, there are several empirical studies in which one might be able to estimate attenuation map and activity distribution simultaneously with emissive sinogram alone without transmission scan. However, their algorithms are based on the model in which does not include the background counts term, and so is unrealistic. If the background counts component has been included in the model, their algorithm would introduce non-monotonic reconstruction algorithm which results in vain in practice. in this paper, we develop a monotonic and parallelizable algorithm for simultaneous reconstruction of both characteristics and present the validity through some simulations.

  • PDF