• 제목/요약/키워드: transmission distribution

Search Result 1,550, Processing Time 0.032 seconds

On the Code Selection of a Multicode DS/CDMA System for a High Data Rate Transmission

  • Kim, Jin-Young
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.457-460
    • /
    • 2000
  • The effect of code selection for a multicode DS/CDMA system is evaluated for a high deta rate transmission, The performance is evaluated in terms of bit error and outage probabilities. The multipath fading channel is modeled as a Nakagami-m distribution which has been known to be appropriate to model the multipath fading in urban as well as indoor channels. From simulation results, it is shown that the concatenated sequence of Walsh code and Gold sequence is most promising among many code selections. The considerations in this paper can be applied to the next-generation mobile communication systems such as IMT-2000 which requires high bit rate transmissions.

  • PDF

Electrical Breakdown Properties of Oil-paper Insulation under Pulsating Voltage Influenced by Temperature

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1735-1743
    • /
    • 2016
  • Insulation of valve-side windings in converter transformer withstands pulsating voltages, which will produce more serious insulation problems. In this paper, the electric breakdown experiments of oil-paper insulation specimens were executed at pulsating voltages and different temperatures. Experiment and analysis results showed that the breakdown voltage decreased with increasing temperature under pulsating voltage. The influence of temperature proves to be more significant once the temperature exceeds a limitation threshold. A fitting formula between breakdown voltage and the temperature was reported. Finally, in order to clearly understand the breakdown properties under pulsating voltage, the electric field distribution and space charge behavior under pulsating voltage at different temperature were discussed.

Spread Spectrum Method based Power Line Communication for Plant Monitoring and Control System (전력선 통신을 이용한 plant 감시 제어 시스템)

  • 서민상;성석경;안병규
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.211-215
    • /
    • 1997
  • Localized communication networks for office automation, security monitoring, environmental management of buildings, computer communications, and other applications enjoy every increasing demand. This paper proposes a direct sequence spread spectrum communication system for use in power line data transmission. Advantages of power distribution circuits include reasonably universal coverage and easy access vis a standard wall plug. Disadvantages include limited communication bandwidth, relatively high noise levels, and varying levels of impedance, noise, and attenuation. Spread spectrum signalling provides immunity to narrow-band signal impairments and multiplexing capability. Our prototype power line communication module supports completely physical and data link layers based on the international standard ISO 10368 for reliable high-speed power line communication system. Moreover it provides useful functions to compose a plant monitoring and control system. All the circuits of the communication module are included in one compact circuit. Thus a functional communication system for the power line plant monitoring and control is implemented.

  • PDF

Improvement of Time Synchronization over Space Wire Link (스페이스와이어 링크의 시각 동기 성능 개선)

  • Ryu, Sang-Moon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.11
    • /
    • pp.1144-1149
    • /
    • 2009
  • This paper deals with the time synchronization problem over SpaceWire links. SpaceWire is a standard for high-speed links and networks between spacecraft components, which was invented for better, cheaper, faster on-board data handling in spacecraft. The standard defines Time-Code for time distribution over SpaceWire network. When a Time-Code is transmitted, transmission delay and jitter is unavoidable. In this paper, a mechanism to remove Time-Code transmission delay and jitter over SpaceWire links is proposed and implemented with FPGA for validation. The proposed mechanism achieves high resolution clock synchronization over SpaceWire links, complies with the standard and can be easily adopted over SpaceWire network.

Detection Range Estimation Algorithm for Active SONAR System and Application to the Determination of Optimal Search Depth (능동 소나 체계에서의 표적 탐지거리 예측 알고리즘과 최적 탐지깊이 결정에의 응용)

  • 박재은;김재수
    • Journal of Ocean Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.62-70
    • /
    • 1994
  • In order to estimate the detection range of a active SONAR system, the SONAR equation is commonly used. In this paper, an algorithm to calculate detection range in active SONAR system as function of SONAR depth and target depth is presented. For given SONAR parameters and environment, the transmission loss and background level are found, signal excess is computed. Using log-normal distribution, signal excess is converted to detection probability at each range. Then, the detection range is obtained by integrating the detection probability as function of range for each depth. The proposed algorithm have been applied to the case of omni-directional source with center frequency 30Hz for summer and winter sound profiles. It is found that the optimal search depth is the source depth since the detection range increase at source depth where the signal excess is maximized.

  • PDF

The dynamic response of a prototype steel floor using velocity-source type of excitation

  • Magalhaes, Max D.C.
    • Structural Engineering and Mechanics
    • /
    • v.46 no.3
    • /
    • pp.371-385
    • /
    • 2013
  • Vibration isolators and anti-vibration mounts are ideal, for example, in creating floating floors for gymnasiums, or performance spaces. However, it is well-known that there are great difficulties on isolating vibration transmission in structural steel components, especially steel floors. Besides, the selection of inertia blocks, which are usually used by engineers as an effective vibration control measure, is usually based on crude methods or the experience of the engineers. Thus, no simple method or indices have been available for assessing the effect of inertia blocks on vibration isolation or stability of vibratory systems. Thus, the aims of this research are to provide further background description using a FE model and present and implement a modal approach, that was validated experimentally, the latter assisting in providing improved understanding of the vibration transmission phenomenon in steel buildings excited by a velocity-source type of excitation. A better visualization of the mean-square velocity distribution in the frequency domain is presented using the concept of modal expansion. Finally, the variation of the mean-square velocity with frequency, whilst varying mass and/or stiffness of the coupled system, is presented.

Determination of Channel Capacity Bounds of Narrow Band ISDN Subscriber Line in the Presence of Impulsive Noise (임펼스성 잡음이 있을때 협대역 ISDN 가입자 전송로의 통신로 용량 한계 결정)

  • Lee, Jong-Heon;Sung, Tae-Kyung;Chin, Yong-Ohk
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.854-858
    • /
    • 1987
  • This paper considers impulsive noise which produce burst error in high speed(approx.160Kbps) data transmission like ISDN(Integrated Servise Digital Network) using PSTN(Public Switching Telephone Network). To begin with, we obtains the transfer function of subscriber line to calculate the variation of bandwidth when the gain of receiver is fixed and channel capacity of non-gaussian channel in upper-and lower bound, and evaluates the transmission capability. In this paper compares channel capacity bounds which obtains when probability density function of impulsive noise is Laplacian distribution function with impulsive noise generated by waveform synthesier.

  • PDF

Analysis of the lightning characteristics by the LPATS in KOREA (낙뢰위치 표정시스템(LPATS)에 의한 2004넌 한반도 낙뢰통계 분석결과)

  • Kwak, J.S.;Woo, J.W.;Kweon, D.J.;Kang, Y.W.;Moon, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.606-608
    • /
    • 2005
  • As the overhead transmission lines are exposed to the outdoor weather, the causes of the transmission lines faults are from natural conditions, and among these faults, the outage rate due to lightning is more than 60%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

A Study on the Long-term Mechanical Properties Under Static and Cyclic State of Composite Insulators for Transmission Lines (송전용 고분자 애자의 정적 및 동적인 상태에서 장기 기계적 특성 연구)

  • Kim, S.Y.;Kim, Y.S.;Hong, J.Y.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.869-871
    • /
    • 1998
  • The extensive use of composite insulators for transmission lines can ultimately be justified only on long-term qualification tests. The actual load working on the insulator in the field is not static load but cyclic load. So in this paper, we discussed an examination of aging degradation by mechanical performance of composite insulators under static tension load and cyclic tension load. and also described useful approaches for analyzing their long term performance so as to develop reliable composite insulators. The static and cyclic tension load-time test data were examined by Weibull distribution for their capability of presuming long term performance. It was found that cyclic tension loads were more severe than static tension loads. The results also indicate that it may be relevant for an user to select composite insulators on basis of their performance under cyclic tension loads than static tension loads.

  • PDF

Energy Saving Properties of Sol Gel Dip Coated Indium Tin Oxide Films on a Glass Pane (창유리 위에 졸겔 담금 방법으로 코팅된 인듐 주석 산화막의 에너지 절약 특성)

  • 정형진;이희형;이동헌;이전국
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.1
    • /
    • pp.48-52
    • /
    • 1992
  • Indium tin oxide (ITO) layers are of considerable interest on account of the combination of properties they provide high electrical conductivity, high infrared reflection with high solar energy transmission, high transmission in the visible range. We are concerned about the variation of the spectral transmittances and sheet resistances as the thickness of SiO2-ZrO2 barrier layer and ITO layers and heat treating conditions are changed. Transmittances and reflectivities were studied by measuring UV-VIS-NIR-, FT-IR spectroscopy. ITO films are crack free, homogeneous and of polycrystalline cubic structure. The microstructure of good ITO films shows a narrow grain size distribution and mean value of 100 nm. The selectivity of absorbing properties is improved by increasing the thickness of ITO films. The increase of sheet resistance of ITO films are due to the increase in the reaction between films and glass substrate.

  • PDF