• Title/Summary/Keyword: transmission distribution

Search Result 1,550, Processing Time 0.031 seconds

Analysis on Voltage Sag in Low Voltage DC Distribution System according to the Number of Poles (극 수에 따른 저압직류 배전계통의 순시전압강하 분석)

  • Noh, Chul-Ho;Kim, Doo-Ung;Gwon, Gi-Hyeon;Oh, Yun-Sik;Han, Jun;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.66-73
    • /
    • 2015
  • AC-based power systems, having the advantages that voltage transformation and long distance transmission are easy, have been constructed since the last 19th century. However, DC-based power system is paid attention these days because of the development of power electronic devices as well as the increase of digital loads and distributed generation. For instance, the transmission systems using High Voltage DC (HVDC) are commercially operated in the world and the researches on distribution system using Low Voltage DC (LVDC) are gradually increased. This paper analyzes voltage sag, resulted from faults, in LVDC distribution system according to the number of poles. Modeling and simulation with various conditions are conducted by using ElectroMagnetic Transients Program (EMTP). Moreover, some countermeasures to reduce voltage sag in LVDC distribution system are suggested briefly.

Power Frequency Magnetic Field Reduction Method for Residents in the Vicinity of Overhead Transmission Lines Using Passive Loop

  • Lee, Byeong-Yoon;Myung, Sung-Ho;Cho, Yeun-Gyu;Lee, Dong-Il;Lim, Yun-Seog;Lee, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.829-835
    • /
    • 2011
  • A power frequency magnetic field reduction method using passive loop is presented. This method can be used to reduce magnetic fields generated within the restricted area near transmission lines by alternating current overhead transmission lines. A reduction algorithm is described and related equations for magnetic field reduction are explained. The proposed power frequency magnetic field reduction method is applied to a scaled-down transmission line model. The lateral distribution of reduction ratio between magnetic fields before and after passive loop installation is calculated to evaluate magnetic field reduction effects. Calculated results show that the passive loop can be used to cost-effectively reduce power frequency magnetic fields in the vicinity of transmission lines generated by overhead transmission lines, compared with other reduction methods, such as active loop, increase in transmission line height, and power transmission using underground cables.

Delay Analysis of a Message based on the Stop-and-Wait ARQ in a Time- Varying Radio Link (시변 패킷 기반 무선 링크에서 정지-대기 ARQ 기반 메시지의 지연 시간 분석)

  • 정명순;박홍성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.9A
    • /
    • pp.684-693
    • /
    • 2003
  • This paper analyzes transmissiondelays of a message and a packet in a time-varying and packet-based radio link. The paper assumes that thearrivals of messages have a Bernoulli process and the lengths of the messages a exponential distribution. To reflect the feature of the time-varying radio link, we use a two-state Markov model. From the model the mean transmission delay of and the mean queue length of the packet are analyzed in terms of the packet distribution function, the packet transmission service time, and the PER of the radio link. And the mean message transmission delay time and the mean queue length are derived using the performance indices of the packet. Numerical results show that the message arrival rate and the message length have some bounds to keep the transmission of the message steady and to improve the performance indices of the message. It can be known that the PER of the state influences on the performance indices more than the sojourn time of the state.

An Efficient Implementation of Tornado Code for Fault Tolerance

  • Lei, Jian-Jun;Kwon, Gu-In
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.2
    • /
    • pp.13-18
    • /
    • 2009
  • This paper presents the implementation procedure of encoding and decoding algorithms for Tornado code that can provide fault tolerance for storage and transmission system. The degree distribution satisfying heavy tail distribution is produced. Based on this distribution, a good random irregular bipartite graph is attained after plenty of trails. Such graph construction is proved to be efficient, and the experiments also demonstrate that the implementation obtains good performance in terms of decoding overhead.

  • PDF

Performance of WDM Signals in Optical Links with Random Distribution of Residual Dispersion Per Span only in Half Transmission Section of Total Length (전송 반 구획에서만 중계 구간 당 분산이 랜덤하게 분포하는 광 링크에서의 WDM 신호의 성능)

  • Lee, Seong-Real
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.3
    • /
    • pp.440-448
    • /
    • 2012
  • Optimal net residual dispersion (NRD) and effective launching power range of optical transmission links with optical phase conjugator (OPC) and dispersion management (DM) for compensating the distorted wavelength division multiplexing (WDM) signals due to interaction of group velocity dispersion (GVD) and optical nonlinear effects. WDM systems considered in this research have optical links with the random distribution of residual dispersion per span (RDPS) in each single mode fiber (SMF) spans of only one half transmission section for designing the adaptive optical transmission system configurations. It is confirmed that optimal NRD is 10 ps/nm and effective launching power range is obtained to be -8~1 dBm under NRD = 10 ps/nm in optical links with total dispersion controlled by precompensation. And, it is also confirmed that optimal NRD is -10 ps/nm and effective launching power range is obtained to be -7.5~1 dBm under NRD = -10 ps/nm in optical links with total dispersion controlled by postcompensation.

Study on the measuring system of power quality for transmission system (송전계통의 전기품질 측정 시스템에 관한 연구)

  • Kim, Yeoung-Noh;Shin, Bong-Il;Lee, Hee-Chul;Kwak, No-Hong;Jeon, Young-Soo;Park, Sang-Ho;Lee, Il-Moo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.107-109
    • /
    • 2006
  • The additional matters appear to be considered in several aspects for building up power-quality measuring system of transmission system(high voltage system) compared to distribution system(middle or low voltage system). Like in distribution system, input signals are also received from PT and CT source of voltage and current respectively in transmission system and applied in accordance with a certain rate. In this case, very big error rate can be occurred according to the specification of the measuring system as the applying rate is bigger than in distribution system beyond comparison. In addition, when the abnormal signal occurred such as sag/swell, interruption, transient etc., power quality of other sites linked to the system also should be checked to find the accurate cause of the abnormal power-quality signals from the corresponding site. Accordingly, the accurate diagnosis on the condition of Power quality for the system depends on the way how the synchronization system is brought along for each site. This paper will suggest the solution for the most effective system building focused on how to solve the problem of the error rate and synchronization described in the above when building up the measuring system of power quality for transmission system.

  • PDF

Study on the measuring system of power quality for transmission system (송전계통의 전기품질 측정 시스템에 관한 연구)

  • Kim Yeoung-Noh;Shin Bong-Il;Lee Hee-Chul;Kwak No-Hong;Jeon Young-Soo;Park Sang-Ho;Lee Il-Moo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.432-434
    • /
    • 2006
  • The additional matters appear to be considered in several aspects for building up power-quality measuring system of transmission system(high voltage system) compared to distribution system(middle or low voltage system). Like in distribution system, input signals are also received from PT and CT source of voltage and current respectively in transmission system and applied in accordance with a certain rate. In this case, very big error rate can be occurred according to the specification of the measuring system as the applying rate is bigger than in distribution system beyond comparison. In addition, when the abnormal signal occurred such as sag/swell, interruption, transient etc., power quality of other sires linked to the system also should be checked to find the accurate cause of the abnormal power-quality signals from the corresponding. site. Accordingly, the accurate diagnosis on the condition of power quality for the system depends on the way how the synchronization system is brought along for each site. This paper will suggest the solution for the most effective system building focused on how to solve the problem of the error rate and synchronization described in the above when building up the measuring system of power quality for transmission system.

  • PDF

Phase Noise Spectrum Distribution Analysis for Next-generation VSAT Satellite System (차세대 VSAT 위성통신시스템의 위상잡음 스펙트럼 분포 해석)

  • Kim, Young-wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1831-1836
    • /
    • 2016
  • Phase noise spectrum distributions of signal generators for next-generation VSAT satellite system based on DVB-RCS2 were analyzed in this paper. The forward link of VSAT system utilizes the APSK higher-order modulation methods based on the DVB-S2 ACM, the modulation methods of the return link utilizes the higher-order PSK and QAM based on the DVB-RCS2. In digital satellite system using the higher-order modulation techniques, the phase noise have an effect on transmission performance, the transmission performance is dominantly degraded by the phase noise of signal generators in the transmission system. The phase noise spectrum distribution of signal generators are analyzed by considering the ACM conditions that adopts the modulation techniques and data rates due to satellite transmission environment. The proper phase noise spectrum distribution for next-generation VSAT system based on DVB-RCS2 are proposed from the analyzed phase noise spectrum characteristics.

BER DEGRADATION DUE TO THE PHASE NOISE SPECTRAL SHAPE IN LMDS SYSTEMS

  • Kim, Youngsun;Song, Jong-In;Kim, Kiseon
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.113-116
    • /
    • 2000
  • Phase noise of oscillator gives the performance degradation significantly when a high carrier frequency and low transmission rate are used. The BER(Bit Error Rates) degradation of QPSK(Quadrature Phase Shift Keying) transmission is analyzed with the oscillator phase noise level specified in downstream physical interface of LMDS(Local Multipoint Distribution Services) which is described in DAVIC(Digital Audio Visual Council). The model used for the phase noise is a power-law model. We also investigated the effects of the various transmission rates on system performance. For the transmission rate below 0.5 Mbps, the BER performance is severely degraded and we verified that the transmission rate, 20 Mbps, is adequate for the downstream of LMDS systems.

  • PDF

PER Analysis for Cooperative Multi-Hop Transmission Protocol over Nakagami-m Fading Channels

  • Duy, Tran Trung;Kong, Hyung-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.3
    • /
    • pp.189-195
    • /
    • 2012
  • In this paper, we propose a novel protocol called a Multi-hop Diversity Transmission protocol in which the retransmission is realized by a relay that is Nearest to a current Source (MDTNS). We derive the mathematical expressions of the packet error rate (PER) and the average number of transmissions over Nakagami-m fading channels, and verify them by Monte Carlo simulations. The simulation results show that the MDTNS protocol improves the performance of the network in terms of PER when compared to the Multi-hop Diversity Transmission protocol in which the retransmission is done by a relay that is Nearest to Destination (MDTND) and to the conventional multi-hop transmission (CMT) protocol.