• Title/Summary/Keyword: transmission analysis

Search Result 5,831, Processing Time 0.033 seconds

Analysis of Inductive Interference from EHV Transmission to buried Gas Pipelines (초고압 송전선로에서 가스관에 미치는 유도 장해 해석)

  • Lee, Seung-Youn;Ko, Eun-Young;Yun, Suk-Moo;Park, Nam-Ok;Shin, Myung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.458-460
    • /
    • 2000
  • In this paper, we analyze the inductive coupling between overhead power transmission lines and neighbouring gas pipelines or other conductors, when they parallel to a line section in a phase-to-earth fault is assumed on the transmission line. A numerical procedure employing the finite-element method(FEM) is used in conjunction with Faraday's law, in order to predict the current in a faulted transmission line as well as the induced voltages across points on a pipeline running parallel to the faulted line and remote earth. The results lead to conclusion that may be useful to power system engineers.

  • PDF

Basic Design for the 500kV Transmission System In Myanmar (미얀마 500kV 송전망 기본설계)

  • Baek, S.D.;Kim, J.H.;Choi, Y.S.;Han, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.40-41
    • /
    • 2006
  • KEPCO conducted the project called the "Feasibility Study & Basic Designs for the 500kV Transmission System in Myanmar" as its second overseas project following the "Development Study on the Power System Network Analysis in Myanmar" as it first project. This paper deals with the design processes and results of 423 kilometers of the 500kV single circuit transmission lines and three substations. The main contents of the basic design include insulation design, transmission line design and substation design.

  • PDF

Benefit/Cost Analysis with Power Market Simulation Software on The Transmission System Expansion (송전망확충의 경제성평가를 위한 전산모형 이용방안)

  • Moon, S.P.;Choi, Y.C.;Jang, B.H.;Kim, S.Y.;Yoon, J.S.;Lee, W.K.;Park, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.72-73
    • /
    • 2006
  • As the electric power market environments are being changed, suitable data for expansions should be subjected to stockholders. And the public responses are requested for transmission system expansion. The necessity of transmission system expansion can be easily assessed via the benefit/cost evaluations. Because the benefit/cost evaluation of the transmission system expansions required variety elements, which can be depended on electric power market simulation software. On this paper, a method is illustrated using the PPOOL developed by PPC and PSS/E developed by PTI.

  • PDF

A Study on Heat Transfer of an Underground Power Transmission Cable-Joint (지중송전케이블 접속부에서의 열전달에 관한 연구)

  • Park, M.H.;Kim, J.K.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.4
    • /
    • pp.265-277
    • /
    • 1993
  • Recently, underground transmission system is growing continuously according to the electric power demand increase in the downtown area. Even if domestic cable makers are manufacturing 154kV oil filled cable and joint, the design technology of cable-joint has not been fully self-reliance. This study is aimed at the detail heat transfer analysis of 154kV cable-joint. So, that is cut into the five sections in order to analyze a conjugate natural convection in two dimensional $r-{\theta}$ coordinate. The streamline and temperature distributions are obtained for each sections. Also the changes of those are analyzed with respect to the variation of transmission currents and cable-joint surface heat transfer coefficients. The same analyses are also shown in view point of the maximum temperature of conductor and local equivalent conductivity.

  • PDF

Pump Light Porer of Wideband Optical Phase Conjugator Dependence on Amplifier Spacing in 320 Gbps WDM Systems with MSSI

  • Lee Seong-Real
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.8A
    • /
    • pp.735-744
    • /
    • 2006
  • In this paper, the optimum pump light powers of optical phase conjugator(OPC) are numerically investigated as a function of amplifier spacing in 1,200 km $8{\times}40$ Gbps WDM systems with 0.1, 0.4, 0.8, or 1.6 ps/nm/km dispersion coefficient. It is confirmed that the variation of optimal pump light power dependence on amplifier spacing for NRZ transmission system is smaller than that for RZ transmission system through the evaluations and analysis of eye opening penalty(EOP) characteristics. And, in both cases of NRZ and RZ transmission, the variation of optimal pump light power is more increased as amplifier spacing becomes longer. Additionally, it is confirmed that the best amplifier spacing in NRZ and RZ transmission system is 50 km.

Analysis on Characteristics of Transmission Loss using Marginal Loss Factors Based on the KEPCO's Expected Peak Load Data of Year 2000 (한계손실계수에 의한 한전 예상첨두계통 송전손실 특성 분석)

  • NamKung, Jae-Yong;Choe, Heung-Gwan;Mun, Yeong-Hwan;O, Tae-Gyu;Im, Seong-Hwang;Han, Yong-Hui
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.7
    • /
    • pp.333-339
    • /
    • 2001
  • The transmission networks are not perfect conductors and a percentage of the power generated is therefore lost before it reaches the loads. This network loss effects to the cost of suppling power to consumers, and must be considered if the most efficient dispatch and location of generators and loads is to be achieved. In this paper, we propose an approximate calculation of marginal loss factors to analyze characteristics of transmission loss of KEPCO power system. These static marginal loss factors are approximately calculated based on the KEPCO's expected summer peak load data of year 2000.

  • PDF

Reduction Methods of Sheath Circulating Current in Underground Cable (지중 송전선로에서 시스 순환전류 저감 방안)

  • Ha, C.W.;Kim, J.N.;Lee, S.K.;Kim, D.W.;Park, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.175-177
    • /
    • 2002
  • The use of underground transmission cables has increased continuously in densely inhabited urban and suburban for power transmission. Two or more transmission lines are outgoing from one substation in many cases, and one line comprises twin circuits. In order to meet the increasing do and for electric power, underground tables of two or fore circuits are installed in ducts in parallel for several kilometer in the same route. It, however, has not been known generally that the sheath circulating current is generated in a system where a large number of cables are laid on the same route. Therefore, this paper describes an improved analysis method for sheath circulating current on underground transmission cables using EMTP. Author propose several methods to reduce sheath circulating current. The analysing method and reduction methods for two or more underground cables will be really improved for cable system utility.

  • PDF

Identification of Correlative Transmission Lines for On-Line Stability Diagnosis (온라인 전력계통 안정도 진단을 위한 선로 선정 방안)

  • Cho, Yoon-Sung;Jang, Gil-Soo;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.3-6
    • /
    • 2001
  • Power system stability is correlated with system structure, disturbances and operating conditions. and power flows in transmission lines are closely related with those conditions. This paper discusses a methodology to identify crucial transmission lines for stability diagnosis with respect to transient stability and small-signal stability. On-line monitoring of the selected lines enables to predict system stability in real-time. Also, a Procedure to make a priority list of monitored transmission lines using contingency analysis. The procedure is applied to the PSS/E test system. and it shows capabilities of the proposed method.

  • PDF

Analysis of Magnetic Field on Ultra High Voltage ac Transmission Line (초고압 송전선로의 자계해석에 관한 연구)

  • Lee, Joo-Youl;Ko, Eun-Young;Jung, Ho-Sung;Shin, Myung-Chul;Kweon, Myung-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1382-1384
    • /
    • 1999
  • Traditional magnetic field computation techniques assume that the current carrying power line conductors are straight horizontal wires. This assumption result in much errors. So this paper considerd catenary curve for the dip of real transmission line. We have data from various position at transmission line, on the earth. And as far from transmission condutor a eddy current affect of the position are con siderd.

  • PDF

Experimental and Parametric Study on the Output Coupled type Continuously Variable Transmission

  • Kim, Yeon-Su;Park, Jae-Min;Park, Sang-Hoon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.3
    • /
    • pp.28-36
    • /
    • 2002
  • The continuously variable transmission (CVT) mechanism considered here is the output coupled type which combines the functions of a 2K-H I type differential gear unit and a V-belt type continuously variable unit (CVU). One shaft of the CVU is connected directly to the output shaft and another shaft of it is linked to the differential gear unit. It is shown that some fundamental relations (speed ratios, power flows and efficiencies) for twelve mechanisms previously described are valid by various experimental studies, six of them produce a power circulation and the others produce a power split. Parametric analysis is carried out in relation to the efficiency, speed ratio and power ratios in order to assist in the design of an optimum configuration. Some useful properties associated with power flow modes also are discussed in the output coupled type continuously variable transmission.