• 제목/요약/키워드: transmission analysis

검색결과 5,831건 처리시간 0.038초

Analysis of Dynamics Characteristics for Friction Elements in Automatic Transmission (자동변속기 마찰요소의 동특성 해석)

  • 최영종;정우진;김성원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • 제5권5호
    • /
    • pp.9-19
    • /
    • 1997
  • In this paper, the modeling and analysis of dynamic characteristics has been carried out for friction clutches and brakes in an automatic transmission. From the operating oil pressure generated by the valve-body, time delay by check valve and the movement of piston has been examined. Also torque capacity and torque transferred at the clutch is studied. Heat capacity and temperature distribution at the reaction plate of clutch are codeled by time-dependent, nonhomogeneous partial differential equation, and brake torque, brake time, and the amount of heat generated are investigated. It is found that the time delay at the check valve is very short but dominant at the spool.

  • PDF

Network Reduction Method for Power System Transient Analysis ; Time-Domain Formulation Based On The Network Function (과도 상태 해석을 위한 계통 축약법 ; 계통 함수를 이용한 시간 영역 해석법)

  • Hong, J.H.;Kang, Y.C.;Cho, K.R.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.417-421
    • /
    • 1991
  • In electromagnetic transient analysis, complex transmission system should be modelled in detail. But in large system, this full representation of power transmission system has a big burden in many sides such as computation time, modelling efforts, etc. It is very required, therefore, in electromagnetic transients studies to represent parts of a complete system in a reduced or an equivalent form. This paper develops the method from which system equivalents may be derived. The suggested method is of an essentially transient form, and allows travelling wave interaction between the equivalent and explicit transmission network to be modelled.

  • PDF

Characteristic analysis of LCC and VSC HVDC system in Jeju power system using RTDS (RTDS를 이용한 제주도 전력계통에서의 전압형과 전류형 직류송전 시스템 특성분석)

  • Ju, Chang-Hyeon;Kim, Jin-Geun;Dinh, Minh-Chau;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.828-829
    • /
    • 2011
  • This paper performs a comparison analysis of two types of HVDC system in Jeju power system. A traditional HVDC transmission system had been composed of line commutated converter based on thyristors and the development of semiconductors enables to apply voltage source converter using IGBTs. The detailed parameters of Jeju power system were considered to make a similar condition with real system in real time digital simulator. Two types of HVDC transmission system were modeled and simulated to compare their characteristics in Jeju power system. The simulation results demonstrate that the VSC-HVDC system has more stable performance due to the fast response speed than LCC-HVDC when the transmission capacity was fluctuated.

  • PDF

A Variation of Maximum Stress with Axial Loading in Porcelain Insulators for Transmission Line using ANSYS (ANSYS를 이용한 송전용 자기재 애자의 장력에 따른 특성 변화)

  • Woo, B.C.;Han, S.W.;Cho, H.G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.104-107
    • /
    • 2003
  • The ageing cause in many porcelain suspension insulators which occur on transmission and distribution line with dead-end stings is mechanical stress in interface between porcelain and cement materials. It is known that the principal mechanical stress which give electrical failure is the results of the displacement is due to cement growth. We studied an analysing method to find out a deformation of brittle porcelain with a thermal expansion of cement for suspension insulator. These simulation analysis and experimental results show that cement volume growths affect severely to be mechanical failure ageing. These simulation analysis and experimental results show that axial loading affects of Porcelain insulators severely to be mechanical failure ageing.

  • PDF

Performance Analysis of Wireless Communication Networks for Smart Metering Implemented with Channel Coding Adopted Multi-Purpose Wireless Communication Chip (오류 정정 부호를 사용하는 범용 무선 통신 칩으로 구현된 스마트 미터링 무선 네트워크 시스템 성능 분석)

  • Wang, Hanho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • 제64권4호
    • /
    • pp.321-326
    • /
    • 2015
  • Smart metering is one of the most implementable internet-of-thing service. In order to implement the smart metering, a wireless communication network should be newly designed and evaluated so as to satisfy quality-of-service of smart metering. In this paper, we consider a wireless network for the smart metering implemented with multi-purpose wireless chips and channel coding-functioned micro controllers. Especially, channel coding is newly adopted to improve successful frame transmission probability. Based on the successful frame transmission probability, average transmission delay and delay violation probability are analyzed. Using the analytical results, service coverage expansion is evaluated. Through the delay analysis, service feasibility can be verified. According to our results, channel coding needs not to be utilized to improve the delay performance if the smart metering service coverage is several tens of meters. However, if more coverage is required, chanel coding adoption definitely reduces the delay time and improve the service feasibility.

Characteristic Analysis of Power Optical Fiber Composite Cable System on Underground Transmission Lines (지중송전선로 광 복합 전력케이블 시스템 특성분석)

  • Jung, Chae-Kyun;Park, Hung-Sok;Jang, Tai-In;Kang, Ji-Won;Kim, Jong-Chae;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.531-532
    • /
    • 2011
  • This paper describes the characteristics analysis of power-optical fiber composite cable on underground transmission lines. The effects on grounding, air gap and contact resistance are variously analysed using EMTP in normal operating condition. From these results, in this paper, the scheme for protecting the electrically abnormal phenomena will be established on power-optical fiber composite cable of underground transmission lines.

  • PDF

Performance Analysis of CVTs with a 2K-H II Differential Gear (2K-HII차동기어 결합형 무단변속기의 성능해석)

  • 박재민;김연수;최상훈
    • Journal of the Korean Society for Precision Engineering
    • /
    • 제21권4호
    • /
    • pp.170-178
    • /
    • 2004
  • Continuously variable transmission (CVT) mechanisms considered here are input coupled types that combine the functions of a 2K-H II type differential gear and a V-belt type continuously variable unit (CVU). For the 8 different mechanisms, 4 of them are power-circulation modes while the other 4 are power-split modes, various performance analysis (speed ratios, power flows, divisions of power transmission in a differential gear and a CVU, and theoretical efficiencies) are performed to vary design parameters. Experimental studies are executed to validate fundamental relations (speed ratios, power flows, efficiencies, occurrence of geared neutral). Some useful characteristics associated with performance also are discussed in the mechanisms.

Boundary Element Analysis on the Hydraulic Characteristics of Submerged Breakwater with Trapezoidal Type (사다리꼴형상 잠제의 수리특성에 관한 경계요소해석)

  • Kim Nam-Hyeong;Yang Soon-Bo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • 제6권4호
    • /
    • pp.45-51
    • /
    • 2003
  • The reflection and transmission of submerged breakwater with trapezoidal type are computed numerically using boundary element method. The analysis method is based on the wave pressure function with the contlnuit? in the analytical region including fluid and porous structures. Wane motion within the porous structures is simulated by introducing the linear dissipation coefficient and added mass coefficient. The results indicate that transmission and reflection coefficient are determined due to the change of slope of submerged breakwater with trapezoidal type.

  • PDF

Analysis of the Harmonic Resonance during Restoration of Primary Restorative Transmission System (시송전계통 탁구과정에서의 고조파 공진 현상에 대한 고찰)

  • Lee, H.J.;Lee, K.S.;Park, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.220-222
    • /
    • 2005
  • Power system restoration following a wide area or complete blackout starts with energizing primary restorative transmission systems. During this primary restoration process, unexpected over-voltage may happen due to nonlinear interaction between the unloaded transformer and the transmission system. This is known as the harmonic resonance phenomenon that may cause burning out of transformer or other devices. Since the harmonic resonance originates from the nonlinear characteristics, it is very difficult to predict the occurrence of this phenomenon. This paper reports the possible existence of the harmonic resonance in Korean power system. Analysis of the harmonic over-voltage is presented based on the various simulations using PSCAD/EMTDC.

  • PDF

Development of a System for ATPS Signal Analysis using LabVIEW (LabVIEW를 이용한 ATPS 센서 출력 파형 분석 시스템 개발)

  • Nam, Hyeong-Su;Shin, Eun-Hye;Jang, Gi-Won;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1799-1800
    • /
    • 2006
  • ATPS(Automatic Transmission Position Sensor) is the position sensor of an automatic transmission which transforms the gear changes into the electrical signals and transmits them to TCU. This paper deals with an development of the sensor output signal analysis system for ATPS inspection using LabVIEW. The developed system is designed to carry easily, and it can be installed for inspection directly in a car fitted with an automatic transmission. The system can not only detect the output signals of the sensor but also inspect the sensor behavior under the running state of a car. For this, the system is designed to control the position and the speed of motor. Also, it has the database system for the systematic output data management and the convenient GUI for user.