• Title/Summary/Keyword: transmission analysis

Search Result 5,821, Processing Time 0.033 seconds

Capacity assessment of existing corroded overhead power line structures subjected to synoptic winds

  • Niu, Huawei;Li, Xuan;Zhang, Wei
    • Wind and Structures
    • /
    • v.27 no.5
    • /
    • pp.325-336
    • /
    • 2018
  • The physical infrastructure of the power systems, including the high-voltage transmission towers and lines as well as the poles and wires for power distribution at a lower voltage level, is critical for the resilience of the community since the failures or nonfunctioning of these structures could introduce large area power outages under the extreme weather events. In the current engineering practices, single circuit lattice steel towers linked by transmission lines are widely used to form power transmission systems. After years of service and continues interactions with natural and built environment, progressive damages accumulate at various structural details and could gradually change the structural performance. This study is to evaluate the typical existing transmission tower-line system subjected to synoptic winds (atmospheric boundary layer winds). Effects from the possible corrosion penetration on the structural members of the transmission towers and the aerodynamic damping force on the conductors are evaluated. However, corrosion in connections is not included. Meanwhile, corrosion on the structural members is assumed to be evenly distributed. Wind loads are calculated based on the codes used for synoptic winds and the wind tunnel experiments were carried out to obtain the drag coefficients for different panels of the transmission towers as well as for the transmission lines. Sensitivity analysis is carried out based upon the incremental dynamic analysis (IDA) to evaluate the structural capacity of the transmission tower-line system for different corrosion and loading conditions. Meanwhile, extreme value analysis is also performed to further estimate the short-term extreme response of the transmission tower-line system.

345kV Overhead Transmission Line Collapse Analysis and Countermeasures (345kV 인천화력 송전선로 철탑도괴 원인분석 및 대책)

  • Park, Jae-Ung;Shin, Tai-Woo;Choi, Jin-Sung;Choi, Han-Yeol;Min, Byeong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.531-535
    • /
    • 2010
  • 345kV Incheon Thermal Power Plant Transmission Line Collapse Analysis and Countermeasures. The Typhoon Galmaegi which had been formed in July 15, 2008 diminished into a tropical cyclone and cooled the air above the West Sea. The cooled air colliding with the warm inland air caused a strong whirlwind at some places in the west seaside; the whirlwind battered the 345kV Incheon Thermal Power Plant Transmission Line to be collapsed. The resistance of transmission towers against wind pressure, one of the key elements in transmission line engineering, is designed to endure the pressure corresponding to the maximum instantaneous wind speed. Before the above accident happened, no transmission line has ever been collapsed by a whirlwind. So this paper is aimed to analyze causes that collapsed 345kV Incheon Thermal Power Plant transmission line and to introduce countermeasures.

Development of Transmission Pricing Package Based on Unified Modeling Language (UML 기반의 송전요금계산 패키지 개발)

  • 이찬주;박종배;신중린;김진호;김발호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.111-120
    • /
    • 2004
  • This paper presents an application of Unified Modeling Language(UML) software technique for developing transmission pricing evaluation package. Also, this paper describes a transmission pricing algorithm applicable to a large-scale power system. The usage-based transmission pricing mechanism is very complex since it requires power flow analysis, fault current analysis, sensitivity evaluation of a transmission line, penalty factors calculation, transmission asset databases, and cost allocation rules, etc. For the efficient and flexible development of the transmission pricing package, a UML. approach is applied, which is composed of a use-case diagram, interaction diagram, class diagram, and package diagram using Rational Rose Unified Process(RUP). The designed transmission pricing package can be efficiently modified and reused as the market environments evolves since it is designed by Object-Oriented Programming(OOP).

Energy Efficiency Analysis of Cellular Downlink Transmission with Network Coding over Rayleigh Fading Channels

  • Zhu, Jia
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.3
    • /
    • pp.446-458
    • /
    • 2013
  • Recently, energy-efficient cellular transmission has received considerable research attention to improve the energy efficiency of wireless communication. In this paper, we consider a cellular network consisting of one base station (BS) and multiple user terminals and explore the network coding for enhancing the energy efficiency of cellular downlink transmission from BS to users. We propose the network coded cellular transmission scheme and conduct its energy consumption analysis with target outage probability and data rate requirements in Rayleigh fading environments. Then, the energy efficiency in Bits-per-Joule is further defined and analyzed to evaluate the number of bits delivered per Joule of energy cost. Numerical results show that the network coded cellular transmission significantly outperforms the traditional cellular transmission in terms of energy efficiency, implying that given a Joule of energy cost, the network coded cellular transmission scheme can deliver more bits than the traditional cellular transmission.

Dynamic Analysis of the Power Transmission System in an Industrial Robot (산업용 로봇 손목의 동력 전달계에 대한 동특성 해석)

  • Kim, Woo-Hyung;Chung, Jin-Tai
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.150-155
    • /
    • 2008
  • Dynamic characteristics of a wrist power transmission examine closely with mass property, to present a model which is able to induce the vibration is ultimately the purpose. A robot wrist power transmission for analysis model gets the mass property through the approach to be the experimental. A bearing equivalent stiffness which supports the axis and a gear contact equivalent stiffness are determined by the simplicity analysis model compared the result of the experiment. We calculate the vibration tendency of the robot wrist power transmission by an analysis tool which is called the RecurDyn. We compared it with a signal analysis experiment's which a robot operation happens which is based on the ambient noise.

  • PDF

A Study on the Dynamic Analysis Modeling of Industrial Robot's Wrist Power Transmission (산업용 로봇 손목 동력 전달계의 동특성 해석 모델 연구)

  • 김우형;정두한;최영삼;정진태;임흥순
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.243-246
    • /
    • 2004
  • The dynamic characteristic of a wrist power transmission examine closely with mass property, to present the model which induce the vibration is ultimately the purpose. A robot wrist power transmission for analysis model got the mass property through the approach to be the experimental. A bearing equivalent stiffness which supports the axis and a gear contact equivalent stiffness are determined by the simplicity analysis model compared the result of the experiment. We calculate the vibration tendency of the robot wrist power transmission by an analysis tool which is called the RecurDyn. We compared it with a signal analysis experiment's which a robot operation happens which is based on the ambient noise.

  • PDF

A Study on the Transmission Error of a Star type Epicyclic Gear Train (스타형 유성기어열의 전달오차에 관한 연구)

  • 류형태;이동환;천길정
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.206-212
    • /
    • 1999
  • In this paper, the transmission error of a atar type Epicyclic Gear Train (EGT) has been studied. Dynamic analysis has been executes calculate the rotation angle of the input and output shafts at various loads. Transmission Error of EGT has been measured to compare with the analysis results. There are qualitative similarity between the experimental and analytical results.

  • PDF

Analysis of TCP packet by Protocol Analysis module Design (프로토콜 분석모듈 설계에 의한 TCP 패킷 분석)

  • Eom, Gum-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.234-236
    • /
    • 2004
  • Transmission control protocol(TCP) is protocol used in internet. TCP is seldom transmission error and is protocol based on wire environment. TCP uses 3 way handshake ways, data transmission control through windows size, data transmission control through reception confirmation, sliding window for packet delivery. In this study, designed TCP packet ion module for analyze the TCP segments & correct information about TCP. TCP capture in internet using designed TCP module and analysed TCP segments composition. Through this, could analyze the correct information of protocol in network.

  • PDF

Analysis of Sequence Impedances of 345kV Cable Transmission Systems (실계통 345kV 지중송전선 대칭좌표 임피던스의 해석)

  • Choi, Jong-Kee;Ahn, Yong-Ho;Yoon, Yong-Beum;Oh, Sei-Ill;Kwa, Yang-Ho;Lee, Myoung-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.905-912
    • /
    • 2013
  • Power system fault analysis is commonly based on well-known symmetrical component method, which describes power system elements by positive, negative and zero sequence impedance. In case of balanced fault, such as three phase short circuit, transmission line can be represented by positive sequence impedance only. The majority of fault in transmission lines, however, is unbalanced fault, such as line-to-ground faults, so that both positive and zero sequence impedance is required for fault analysis. When unbalanced fault occurs, zero sequence current flows through earth and skywires in overhead transmission systems and through cable sheaths and earth in cable transmission systems. Since zero sequence current distribution between cable sheath and earth is dependent on both sheath bondings and grounding configurations, care must be taken to calculate zero sequence impedance of underground cable transmission lines. In this paper, conventional and EMTP-based sequence impedance calculation methods were described and applied to 345kV cable transmission systems (4 circuit, OF 2000mm2). Calculation results showed that detailed circuit analysis is desirable to avoid possible errors of sequence impedance calculation resulted from various configuration of cable sheath bonding and grounding in underground cable transmission systems.