• Title/Summary/Keyword: transmission analysis

Search Result 5,798, Processing Time 0.037 seconds

Energy flow finite element analysis of general Mindlin plate structures coupled at arbitrary angles

  • Park, Young-Ho
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.435-447
    • /
    • 2019
  • Energy Flow Finite Element Analysis (EFFEA) is a promising tool for predicting dynamic energetics of complicated structures at high frequencies. In this paper, the Energy Flow Finite Element (EFFE) formulation of complicated Mindlin plates was newly developed to improve the accuracy of prediction of the dynamic characteristics in the high frequency. Wave transmission analysis was performed for all waves in complicated Mindlin plates. Advanced Energy Flow Analysis System (AEFAS), an exclusive EFFEA software, was implemented using $MATLAB^{(R)}$. To verify the general power transfer relationship derived, wave transmission analysis of coupled semi-infinite Mindlin plates was performed. For numerical verification of EFFE formulation derived and EFFEA software developed, numerical analyses were performed for various cases where coupled Mindlin plates were excited by a harmonic point force. Energy flow finite element solutions for coupled Mindlin plates were compared with the energy flow solutions in the various conditions.

Tribological Failure Analysis of Automatic Transmission in a Passenger Car (승용차 자동변속기의 고장사례에 관한 트라이볼로지적 고찰)

  • Kim, Chung-Kyun;Lee, Il-Kwon
    • Tribology and Lubricants
    • /
    • v.21 no.5
    • /
    • pp.227-235
    • /
    • 2005
  • This paper presents a tribological study on the failure cases of automatic transmission components in a passenger car. The automatic transmission system is composed of torque converter, clutch, brake, planetary gear, and valve body controlling oil pressure of an automatic transmission fluid. The most largest influence components in an automatic transmission are a torque converter and clutch plate in which are influenced by a wear and torque converting energy loss. The failure case study of an automatic transmission indicates that the tribological design and maintenance technologies should be considered as a key design concept. This means that the failure and power energy loss come from the friction, wear and a oil leakage of an automatic transmission, which is related to the oil seal and O-ring seal failures.

Performance Analysis and Comparison of Different Data Rates in Wideband CDMA Using Three Different Transmission Schemes

  • Pahadee, Sangita;Ahmed, Kazi M.;Rajatheva, R.M.A.P.;Sigdel, S.
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.552-555
    • /
    • 2002
  • Wideband CDMA is one of the radio access technologies for the third generation in which voice is the basic service. There has been lot of research work in order to find out the suitable transmission scheme to meet the requirement of accommodating variable type of services in Wideband-CDMA. This paper studies the behavior of different services using different transmission schemes in Wideband CDU and compares their performance in terms of BER. Different transmission schemes are found to be suitable for different services. Transmission schemes used are- fixed processing gain scheme also called as variable bandwidth scheme, single code transmission and multicode transmission. It is found that fixed processing gain scheme is suitable fur high data rates. Single code transmission is suitable fer low data rates where as multicode transmission is suitable for low and medium data rates.

  • PDF

Transmission Performance Analysis of Interleaving of TDMA STD DP transmission mode in Air Tactical Communication System (항공전술 통신체계에서 TDMA STD DP 전송모드의 인터리빙 전송성능 분석)

  • Hong, Jin-Keun;Park, Sun-Chun;Kim, Seng-Jo;Park, Jong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.249-251
    • /
    • 2004
  • In this paper, we analyses transmission performance of interleaving for cipher communication in TDMA STD DP mode of aerial tactical communication link. In LINK16 link we present about transmission architecture of STD DP mode and study an effect of interleaving, the capability of crypto synchronization pattern, and a quality of degraded effect of transmission communication during crypto communication.

  • PDF

Dynamic Characteristics of Automatic Transmission System Due to the Change of Planetary Gear Ratio (자동변속기내 유성기어비 변화에 의한 동력전달계의 동적특성)

  • 박영일;김영석
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.10
    • /
    • pp.120-127
    • /
    • 1998
  • In this study the dynamic characteristics of automatic transmission system due to the change of the planetary gear ratio is studied. To study the power flow and shift quality for power transmission the simulation program is developed using the modeling and analysis technique. The results from this study will be used in designing the basic structure of automatic transmission using planetary gear system.

  • PDF

A Study on the Sound Transmission Characteristics of the Corrugated Panels for railway Vehicles (철도차량용 주름패널의 음투과특성에 관한 연구)

  • 김석현;박정모
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.257-264
    • /
    • 1998
  • Sound transmission characteristics are investigated on the corrugated panels which used for railway vehicles. A special purpose program is developed to calculate the sound transmission loss of orthotropic multi-layered panels. Several kinds of corrugated panels are analysed to estimate the transmission performance and the results are compared with the measured data. Calculated transmission losses show good agreement with the measured values in corrugated panels and aluminum/foam multi-layered panels. The analysis results can be utilized to design the corrugated panels and multi-layered panels which are required to reduce the interior noise in railway vehicles.

  • PDF

An Analysis of Congestion Cost for Electric Power Transmission in Consideration of Uncertainty of Future Electric Power System (미래 전력 계통의 불확실성을 고려한 송전혼잡비용 분석)

  • Park, Sung Min;Kim, Sung Soo
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.131-137
    • /
    • 2014
  • It is expected that there will be delay of scheduled transmission network reinforcement and huge investment of renewable energy resources in Korea. As transmission capacity expansion delayed, supplying power to Seoul metropolitan area will not be increased as scheduled. In addition, uncertain renewable energy out of Seoul metropolitan area can cause transmission congestion in the future power system. These two combining effects will make the difference in locational marginal prices(LMP) and congestion costs increase. In that sense, this paper will analyze how much the congestion costs for Korea power system are incurred in the future power system. Most of previous approaches to analyze the congestion costs for electric power system are based on the optimal power flow model which cannot deal with hourly variation of power system. However, this study attempted to perform the analysis using market simulation model(M-Core) which has the capability of analyzing the hourly power generation cost and power transmission capacity, and market prices by region. As a result, we can estimate the congestion costs of future power system considering the uncertainty of renewable energy and transmission capacity.

Analysis and Countermeasure of Lighting Fault on 765kV Transmission Lines (765kV 송전선로 낙뢰고장 분석 및 대책)

  • Min, Byeong-Wook;Lee, Sung-Hak;Kim, Ho-Ki;Kang, Yeon-Woog;Bang, Hang-Kwon;Park, Jae-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.337-338
    • /
    • 2008
  • KEPCO has built, for the first time in the world, 765㎸ double circuit transmission lines which use vertically arranged phase conductor, while 765㎸ transmission lines in other countries are single circuit lines and use horizontally arranged phase conductor. System operating voltage, switching overvoltage, and lightning overvoltage were considered in determining the air gap. Recently, however, lightning outage rate of some 765㎸ transmission lines in KOREA shows that it is more than what is expected. Lightning fault of 765㎸ transmission lines is mostly single phase grounding fault which can be reclosed. But it still needs to be carefully managed, for the bulk system like 765㎸ transmission lines have huge effects on whole power system. This paper introduces analysis and countermeasure of KEPCO's 765㎸ transmission line lightning outage.

  • PDF

Development of Transmission Simulator for High-Speed Tracked Vehicles (고속 무한궤도 차량용 변속기 시뮬레이터 개발)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.14 no.4
    • /
    • pp.29-36
    • /
    • 2017
  • Electronic control technologies that have long been developed for passenger cars spread to construction equipment and agricultural vehicles because of its outstanding performance achieved by embedded software. Especially, system program of transmission control unit (TCU) plays a crucial role for the superb shift quality, driving performance and fuel efficiency, etc. Since the control algorithm is embedded in software that is rarely analyzed, development of such a TCU cannot be conducted by conventional reverse engineering. Transmission simulator is a kind of electronic device that simulates the electric signals including driver operation command and output of various sensors installed in transmission. Standalone TCU can be run in normal operation mode with the signals provided by transmission simulator. In this research, transmission simulator for the tracked vehicle TCU is developed for the analysis of shift control algorithm from the experiments with standalone TCU. It was confirmed that shift experimental data for the simulator setup conditions can be used for the analysis of control algorithms on proportional solenoid valves and shift map.

Effect Analysis of Spacer Stiffness and Interval on Galloping of Power Transmission Lines (스페이서 강성과 간격이 송전선 갤러핑에 미치는 영향분석)

  • Oh, Yun-Ji;Sohn, Jeong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • Due to icing and snow, power transmission lines have asymmetric cross sections, and their motion becomes unstable. At this time, the vibration caused by the wind is called galloping. If galloping is continuous, short circuits or ground faults may occur. It is possible to prevent galloping by installing spacers between transmission lines. In this study, the transmission line is modeled as a mass-spring-damper system by using RecurDyn. To analyze the dynamic behavior of the transmission line, the damping coefficient is derived from the free vibration test of the transmission line and Rayleigh damping theory. The drag and lift coefficient for modeling the wind load are calculated from the flow analysis by using ANSYS Fluent. Galloping simulations according to spacer stiffness and interval are carried out. It is found that when the stiffness is 100 N/m and the interval around the support is dense, the galloping phenomenon is reduced the most.