• Title/Summary/Keyword: transient temperature field

Search Result 114, Processing Time 0.026 seconds

Fracture and Hygrothermal Effects in Composite Materials (복합재의 파괴와 hygrothermal 효과에 관한 연구)

  • Kook-Chan Ahn;Nam-Kyung Kim
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.143-150
    • /
    • 1996
  • This is an explicit-Implicit, finite element analysis for linear as well as nonlinear hygrothermal stress problems. Additional features, such as moisture diffusion equation, crack element and virtual crack extension(VCE ) method for evaluating J-integral are implemented in this program. The Linear Elastic Fracture Mechanics(LEFM) Theory is employed to estimate the crack driving force under the transient condition for and existing crack. Pores in materials are assumed to be saturated with moisture in the liquid form at the room temperature, which may vaporize as the temperature increases. The vaporization effects on the crack driving force are also studied. The Ideal gas equation is employed to estimate the thermodynamic pressure due to vaporization at each time step after solving basic nodal values. A set of field equations governing the time dependent response of porous media are derived from balance laws based on the mixture theory Darcy's law Is assumed for the fluid flow through the porous media. Perzyna's viscoplastic model incorporating the Von-Mises yield criterion are implemented. The Green-Naghdi stress rate is used for the invariant of stress tensor under superposed rigid body motion. Isotropic elements are used for the spatial discretization and an iterative scheme based on the full newton-Raphson method is used for solving the nonlinear governing equations.

  • PDF

Difference of Neuronal Recovery by Incubation Condition after Transient Hypoxia (배양조건에 의한 일과성 저산소상태 후 신경세포회복의 차이)

  • Moon, Soo-Hyeon;Oh, Jae-Inn;Park, Youn-Kwan;Chung, Heung-Sub;Lee, Hoon-Kap;Lee, Ki-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.9
    • /
    • pp.1161-1170
    • /
    • 2000
  • Objective : The transverse hippocampal slice is one of the most commonly studied in vitro models of mammalian brain physiology. However, despite its broad usage, there has been no standardization of slice preparation techniques or recording condition. It is well known that variations in recording conditions can result in profound different effects to neuronal responses. Evoked field potentials, recorded extracellularly, were used to investigate the effects of variations in hippocampal slice preparation protocol on hypoxia responses of CA1 neurones. Material & Methods : Before hypoxic injury, hippocampal slices were incubated for 4 hours. During incubation period, the slices were placed in a incubation chamber($21^{\circ}C$) for recovery from preparation injury and then transferred to recording chamber($34^{\circ}C$) for more recovery and baseline electric recording with current stimulation(0.1Hz). Various time periods in incubation chamber and recording chamber were applied to each experimental group(group 1=60min : 180min, group 2=90min : 150min, group 3=180min : 60min, time in incubation chamber : time in recording chamber) before 10 min hypoxia produced by replacing 95% $O_2$+5% $CO_2$ mixed gas to 95% $N_2$+5% $CO_2$ gas. Calcium, Magnesium ions and several drugs effecting on glutamate receptor also were studied. Recoveries from hypoxic injury of hippocampal slices were estimated by percent recovery of population spike(PS). Statistic analysis of study were performed using paired t-test. Results : The percent recovery of PS after 10min hypoxia was considerably enhanced by increasing the period of current stimulation during incubation period before hypoxic injury. Temperature effect on the result of this experiment was also studied(group 4) but the result from this showed no statistic significance. Low magnesium ion concentration of artificial CSF(Mg-free aCSF) during incubation period enhanced the recovery of PS but low calcium (calcium-free) and high magnesium ion concentration(2mM) reduced it after hypoxic injury. L-glutamate($100{\mu}M$) and AP-5($50{\mu}M$) had no effect on the recovery of PS but CNQX($10{\mu}M$) in artificial CSF during incubation period markedly enhanced the recovery of PS. Co-treatment of AP-5($50{\mu}M$), CNQX($10{\mu}M$) and high magnesium concentration(2mM) enhanced recovery of PS in immediate following period of hypoxic injury but the effect of cotreatment after then decayed rapidly and lost statistic significance. Conclusions : Judging from above results, the condition of baseline recording is important in observing the recovery of population spike after hypoxia, and the time and the condition should be controled more strictly to obtain reliable results.

  • PDF

LATEST RESULTS OF THE MAXI MISSION

  • MIHARA, TATEHIRO
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.559-563
    • /
    • 2015
  • Monitor of All-sky X-ray Image (MAXI) is a Japanese X-ray all-sky surveyer mounted on the International Space Station (ISS). It has been scanning the whole sky since 2009 during every 92-minute ISS rotation. X-ray transients are quickly found by the real-time nova-search program. As a result, MAXI has issued 133 Astronomer's Telegrams and 44 Gamma-ray burst Coordinated Networks so far. MAXI has discovered six new black holes (BH) in 4.5 years. Long-term behaviors of the MAXI BHs can be classified into two types by their outbursts; a fast-rise exponential-decay type and a fast-rise flat-top one. The slit camera is suitable for accumulating data over a long time. MAXI issued a 37-month catalog containing 500 sources above a ~0.6 mCrab detection limit at 4-10 keV in the region ${\mid}{b}{\mid}$ > $10^{\circ}$. The SSC instrument utilizing an X-ray CCD has detected diffuse soft X-rays extending over a large solid angle, such as the Cygnus super bubble. MAXI/SSC has also detcted a Ne emission line from the rapid soft X-ray nova MAXI J0158-744. The overall shapes of outbursts in Be X-ray binaries (BeXRB) are precisely observed with MAXI/GSC. BeXRB have two kinds of outbursts, a normal outburst and a giant one. The peak dates of the subsequent giant outbursts of A0535+26 repeated with a different period than the orbital one. The Be stellar disk is considered to either have a precession motion or a distorted shape. The long-term behaviors of low-mass X-ray binaries (LMXB) containing weakly magnetized neutron stars are investigated. Transient LMXBs (Aql X-1 and 4U 1608-52) repeated outbursts every 200-1000 days, which is understood by the limit-cycle of hydrogen ionization states in the outer accretion disk. A third state (very dim state) in Aql X-1 and 4U 1608-52 was interpreted as the propeller effect in the unified picture of LMXB. Cir X-1 is a peculiar source in the sense that its long-term behavior is not like typical LMXBs. The luminosity sometimes decreases suddenly at periastron. It might be explained by the stripping of the outer accretion disk by a clumpy stellar wind. MAXI observed 64 large flares from 22 active stars (RS CVns, dMe stars, Argol types, young stellar objects) over 4 years. The total energies are $10^{34}-10^{36}$ erg $s^{-1}$. Since MAXI can measure the spectrum (temperature and emission measure), we can estimate the size of the plasma and the magnetic fields. The size sometimes exceeds the size of the star. The magnetic field is in the range of 10-100 gauss, which is a typical value for solar flares.

Construction and Tests of the Vacuum Pumping System for KSTAR Current Feeder System (KSTAR 전류전송계통 진공배기계 구축 및 시운전)

  • Woo, I.S.;Song, N.H.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, Jae-Sik;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.483-488
    • /
    • 2007
  • Current feeder system (CFS) for Korea superconducting tokamak advanced research(KSTAR) project plays a role to interconnect magnet power supply (MPS) and superconducting (SC) magnets through the normal bus-bar at the room temperature(300 K) environment and the SC bus-line at the low temperature (4.5 K) environment. It is divided by two systems, i.e., toroidal field system which operates at 35 kA DC currents and poloidal field system wherein 20$\sim$26 kA pulsed currents are applied during 350 s transient time. Aside from the vacuum system of main cryostat, an independent vacuum system was constructed for the CFS in which a roughing system is consisted by a rotary and a mechanical booster pump and a high vacuum system is developed by four cryo-pumps with one dry pump as a backing pump. A self interlock and its control system, and a supervisory interlock and its control system are also established for the operational reliability as well. The entire CFS was completely tested including the reliability of local/supervisory control/interlock, helium gas leakage, vacuum pressure, and so on.