• Title/Summary/Keyword: transient information

Search Result 715, Processing Time 0.025 seconds

Analysis of Transient Potential Rises of Horizontal Ground Electrodes Considering the Frequency-Dependent of Soil (토양의 주파수의존성을 고려한 정보통신설비용 수평접지전극의 과도전위상승 분석)

  • Ahn, Chang Hwan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.2
    • /
    • pp.147-153
    • /
    • 2016
  • The lightning protection of information and communication facilities is very important factor to improve a reliability of the action of these equipment. Especially the transient potential rise of ground electrode being injected with the lightning current is to be a basic data of the dielectric strength for both power and communication facilities so that more accurate analysis should be required. The transient potential rise can be calculated from the ground impedance and the ground impedance is strongly dependent upon the shape of the ground electrode and the frequency-dependence of soil. The Debye's equation which is able to calculate the characteristics of dielectrics is used to analyze the frequency-dependent of soil. Also, the method to calculate the transient potential rise from the ground impedance is specified in this paper. In order to analyze the transient potential rise resulting from calculations with Debye's equation, TLM(transmission line method) and case of ${\rho}$(resistivity)-constant are simulated, respectively. The length of a horizontal ground electrode is 30 m and simulations were performed at 10, 100, $1000{\Omega}{\cdot}m$ with the standard lightning current waveform. In result, the transient potential rise of horizontal ground electrode calculating with Debye's equation is lower than it of other models.

Detecting Emerging Technology using Information Analysis (정보분석 방법론을 활용한 유망기술 탐색)

  • Lee, Woo-Hyoung;Kim, Han-Joo;Park, Jun-Cheul
    • The Journal of Information Systems
    • /
    • v.17 no.3
    • /
    • pp.235-254
    • /
    • 2008
  • This article describes the latest development of a generic approach to detecting emerging trends and transient in scientific literature. The work makes substantial theoretical and methodological contributions to progressive Information analysis. A specialty is conceptualized as a time variant duality research front concepts in information science. A research front is defined as an emergent and transient grouping of concepts and underlying research issues. The contributions of the approach is that the nature of an intellectual base is algorithmically and temporally identified by emergent research-front terms. The modeling process is implemented in RADERS, and applied to the analysis of telecommunication field. Practical implications of the work are discussed. A number of challenges and opportunities for future studies are identified.

Transient Chirp Analysis of Ml-DFB Laser Module (Transient chirp 측정을 이용한 Modulator 집적 DFB 레이저 모듈의 특성해석)

  • 오윤경;곽계달
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.9
    • /
    • pp.35-41
    • /
    • 1998
  • A transient chirp measurement was used to analyze the chirping characteristics of modulator integrated DFB (MI-DFB) laser module. This method measures the wavelength change due to a small variation in modulation with bias. The measurement system includes a monochrometer and digitizing oscilloscope. The chirping characteristics due to packaging influences can also be accounted for. The chirp parameter calculated using this method was compared with the peak-to peak chirp. They showed the same tendency with modulator bias voltage. These results can be used as a reference when optimizing system parameters.

  • PDF

Cascaded Propagation and Reduction Techniques for Fault Binary Decision Diagram in Single-event Transient Analysis

  • Park, Jong Kang;Kim, Myoungha;Kim, Jong Tae
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.65-78
    • /
    • 2017
  • Single Event Transient has a critical impact on highly integrated logic circuits which are currently common in various commercial and consumer electronic devices. Reliability against the soft and intermittent faults will become a key metric to evaluate such complex system on chip designs. Our previous work analyzing soft errors was focused on parallelizing and optimizing error propagation procedures for individual transient faults on logic and sequential cells. In this paper, we present a new propagation technique where a fault binary decision diagram (BDD) continues to merge every new fault generated from the subsequent logic gate traversal. BDD-based transient fault analysis has been known to provide the most accurate results that consider both electrical and logical properties for the given design. However, it suffers from a limitation in storing and handling BDDs that can be increased in size and operations by the exponential order. On the other hand, the proposed method requires only a visit to each logic gate traversal and unnecessary BDDs can be removed or reduced. This results in an approximately 20-200 fold speed increase while the existing parallelized procedure is only 3-4 times faster than the baseline algorithm.

Investigation of Agrobacterium-mediated Transient dsRNA Expression in Tobacco

  • Choi, Wonkyun;Lim, HyeSong;Seo, Hankyu;Kim, Dong Wook
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.4
    • /
    • pp.394-402
    • /
    • 2019
  • The Agrobacterium tumefaciens mediated gene transfer is widely used to generate genetic transformation of plants and transient assay of temporal exogenous gene expression. Syringe infiltration system into tobacco (Nicotiana benthamiana) leaves is a powerful tool for transient expression of target protein to study protein localization, protein-protein binding and protein production. However, the protocol and technical information of transient gene expression, especially double strand RNA (dsRNA), in tobacco using Agrobacterium is not well known. Recently, dsRNA is crucial for insecticidal effect on destructive agronomic pest such as Corn rootworm. In this study, we investigated the factor influencing the dsRNA expression efficiency of syringe agro-infiltration in tobacco. To search the best combination for dsRNA transient expression in tobacco, applied two Agrobacterium cell lines and three plant vector systems. The efficiency of dsRNA expression has estimated by real-time PCR and digital PCR. As a result, pHellsgate12 vector constructs showed the most effective accumulation of dsRNA in the cell. These results indicated that the efficiency of dsRNA expression was depending on the kind of vector rather than Agrobacterium cells. In summary, the optimized combination of transient dsRNA expression system in tobacco might be useful to in vivo dsRNA expression for functional study and risk assessment of dsRNA.

Transient Noise Reduction in Speech Signal Utilizing a Long-term Predictor (장구간 예측 필터를 이용한 음성 신호에서의 돌발 잡음 제거)

  • Choi, Min-Seok;Kang, Hong-Goo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.1
    • /
    • pp.29-38
    • /
    • 2012
  • This paper presents a transient noise reduction system in a speech signal. The proposed transient noise reduction system utilizes a median filter to reduce the transient noise. Since the median filter can distort speech during the noise reduction, a long-term prediction (LTP) filter is adopted as a pre-processor to minimize speech distortion. The speech information preserved by the LTP filter is re-synthesized after reducing the noise. This paper verifies the weakness of a linear prediction (LP) filter and the superiority of the LTP filter for preserving the speech component in transient noise presence environment. Applying the proposed system, the signal-to-noise ratio (SNR) of output is improved by 8dB in both speech and noise presence region, and PESQ score is increased by 1 point comparing with noisy input.

Transient Impedance Characteristics of Grounding Rods (봉상접지극의 과도임피던스 특성)

  • 김일권;송재용;길경석;권장우
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.133-143
    • /
    • 2001
  • This paper describes the correlation of the transient impedance and its parameters with the stationary resistance of a grounding system to a square pulse current and a lightning impulse current. In the experiment, the grounding system consists of a single grounding rod$(\Psi10[mm], 1[m])$and/or a triple-grounding rods of equilateral triangles with 5[m] spacing for operation. To analyze the transient impedance characteristics of the grounding system, a pulse generator which can produce square wave of a 30[ns] rise-time and a $20[\mus] $pulse duration is designed and fabricated. The injected content in the grounding system and the developed potential were recorded, and the time variation of the transient impedance were calculated as the ratio of the potential rising to the injected current at each time. The transient impedance and the effective surge impedance Z3 which defines economic protection level in power system were quite higher than the stationary resistance. The grounding impedance is decreased by the application of the triple-rods grounding system, and its effect is decreased as the frequency of the current is increased due to the inductance of the grounding leads.

  • PDF

Classification of Underwater Transient Signals Using MFCC Feature Vector (MFCC 특징 벡터를 이용한 수중 천이 신호 식별)

  • Lim, Tae-Gyun;Hwang, Chan-Sik;Lee, Hyeong-Uk;Bae, Keun-Sung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.8C
    • /
    • pp.675-680
    • /
    • 2007
  • This paper presents a new method for classification of underwater transient signals, which employs frame-based decision with Mel Frequency Cepstral Coefficients(MFCC). The MFCC feature vector is extracted frame-by-frame basis for an input signal that is detected as a transient signal, and Euclidean distances are calculated between this and all MFCC feature. vectors in the reference database. Then each frame of the detected input signal is mapped to the class having minimum Euclidean distance in the reference database. Finally the input signal is classified as the class that has maximum mapping rate in the reference database. Experimental results demonstrate that the proposed method is very promising for classification of underwater transient signals.

The Protection methods of Telecommunication Network from Electrical Transient Phenomena (전기적 과도현상으로부터 통신망의 보호대책)

  • Choi, Man-Ho;Kim, Hyun-Duk;Kim, Byung-Cheul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.693-696
    • /
    • 2005
  • Parallel and cross of the electrical power and telecommunication network is become accelerated, because telecommunication equipments are constructed according to road for efficient maintenance of domestic telecommunication network. The electrical power network can generate an electrostatic induction, and is itself transmission medium from electrical transient phenomenon such as lighting. So, transient phenomenon of lightning surge is induced to telecommunication network, and then it is damaged by connecting between electrical ground of electrical power network and telecommunication network. In this study, we found that cut-off of return path current by separate distance between electrical ground of electrical power network and telecommunication network, and cut-off of electrostatic induction voltage by grounding unused leads of both terminals of the electrical and telecommunication network have good effect as the protection methods of telecommunications network from electrical transient phenomena.

  • PDF

Analysis on the Effects of TRV and MOV in Real System with TCSC (TCSC가 적용된 실계통 시스템에서의 TRV와 MOV의 영향에 대한 분석)

  • Lee, Seok-Ju
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.2
    • /
    • pp.41-46
    • /
    • 2019
  • The application of series compensator in a power system affects other devices such as circuit breakers transient recovery voltage (TRV) problem. In this paper, we analyze the TRV effect on a line circuit breaker in the cases with and without thyristor-controlled series capacitor (TCSC) via simulation, and suggest an effective method to overcome the increase of TRV due to the TCSC installation. It also discusses the impact of proposed protection on metal oxide varistor (MOV). A 345 kV transmission line in Korea was selected as a study case. Grid system was modelled using PSCAD (Power Systems Computer Aided Design) / EMTDC(Electro Magnetic Transient Direct Current). The TRV was analyzed by implementing a short circuit fault along the transmission line and at the breaker terminal. The proposed protection scheme, the TRV satisfies the standard. However, the MOV energy capacity increased as the delay time increased. This result can solve the TRV problem caused by the expected transmission line fault in a practical power system.