Transient Queueing Approximation for Modeling Computer Networks (컴퓨터 통신망의 모델링을 위한 비정상 상태에서의 큐잉 근사화)

  • Lee, Bong-Hwan
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.4
    • /
    • pp.15-23
    • /
    • 1995
  • In this paper, we evaluate the performance of a transient queueing approximation when it is applied to modeling computer communication networks. An operational computer network that uses the ISO IS-IS(Intermediate System-Intermediate System) routing protocol is modeled as a Jackson network. The primary goal of the approximation pursued in the study was to provide transient queue statistics comparable in accuracy to the results from conventional Monte Carlo simulations. A closure approximation of the M/M/1 queueing system was extended to the general Jackson network in order to obtain transient queue statistics. The performance of the approximation was compared to a discrete event simulation under nonstationary conditions. The transient results from the two simulations are compared on the basis of queue size and computer execution time. Under nonstationary conditions, the approximations for the mean and variance of the number of packets in the queue erer fairly close to the simulation values. The approximation offered substantial speed improvements over the discrete event simulation. The closure approximation provided a good alternative Monte Carlo simulation of the computer networks.

  • PDF

A Study of the Transient Effect at the Thulium-doped Optical Fiber Amplifier (Thulium이 도핑된 광섬유 증폭기의 과도현상에 관한 연구)

  • 이재명;이영우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.349-352
    • /
    • 2001
  • The transient response in TDFA(Thulium-Doped Fiber Amplifier) is theoretically investigated. The TDFA has the spectral gain band in 1.47 ${\mu}{\textrm}{m}$. The transient model includes the transient buildup of the population inversion, the pump power, the signal power and their transient variation along the fiber amplifier. The results of numerical analysis can predict the gain saturation and recovery time at the fiber amplifier. It also shows the gain saturation and recovery effect depending on the pumping and saturation rate.

  • PDF

Chernoff Bound and the Refined Large Deviation Approximation for Connection Admission Control in CDMA Systems

  • Yeong Min Jang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4B
    • /
    • pp.338-344
    • /
    • 2002
  • This paper proposes a transient (predictive) connection admission control (CAC) scheme using the transient quality of service (QoS) measure for CDMA cellular systems with bursts On-Off sources. We need an approximate and bounded approach for real-time CAC applications. We derive the transient outage probability as the QoS measure using the Chernoff bound and the refuted large deviation approximation. Numerical results show that the predictive CAC is a promising approach for the multicell CDMA systems.

Fringe Field Effects on Transient Characteristics of Nano-Electromechanical (NEM) Nonvolatile Memory Cells

  • Han, Boram;Choi, Woo Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.5
    • /
    • pp.609-614
    • /
    • 2014
  • The fringe field effects on the transient characteristics of nano-electromechanical (NEM) memory cells have been discussed by using an analytical model. The influence of fringe field becomes stronger as the size of a cell decreases. By using the proposed model, the dependency of NEM memory transient characteristics on cell parameters has been evaluated.

Realization of Torsional Response based on Multi-mass Modeling of Turbine-Generator Shaft System (터빈 발전기 축 시스템의 다중 질량체 모델링을 통한 비틀림 응답 구현)

  • Park, Ji-Kyung;Cho, Gyu-Jung;Sohn, Seung-Hyun;Chung, Se-Jin;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.201-207
    • /
    • 2015
  • Turbine-generator torsional response is caused by interaction between electrical transient air-gap torque and mechanical characteristics of turbine-generator shafts. If torsional shaft torque exceeds a certain threshold, the loss of fatigue life may occur and, in the end, it is possible to happen permanent shaft failure. Therefore, it is required to understand the torsional response for reliable operation and protection of turbine-generator shaft system. In this paper, we introduced multi-mass modeling method of turbine-generator shaft system using mechanical-electrical analogy and state-space equation to verify the transient torsional response based on ElectroMagnetic Transient Program (EMTP). These simple realization methods for turbine-generator shaft torsional response could be helpful to understand torsional interaction phenomena and develop the transient torque reduction countermeasures for turbine-generator shaft system.

Modeling, Dynamic Analysis and Control Design of Full-Bridge LLC Resonant Converters with Sliding-Mode and PI Control Scheme

  • Zheng, Kai;Zhang, Guodong;Zhou, Dongfang;Li, Jianbing;Yin, Shaofeng
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.766-777
    • /
    • 2018
  • In this paper, a sliding mode and proportional plus integral (SM-PI) control combined with self-sustained phase shift modulation (SSPSM) for LLC resonant converters is presented. The proposed control scheme improves the transient response while preserving good steady-state performance. An averaged large signal model of an LLC converter with the ZVS modulation technique is developed for the SM control design. The sliding surface is obtained based on the input-output linearization concept. A system identification method is adopted to obtain the transform function of the LLC resonant converter, which is used to design the PI control. In order to reduce the inherent chattering problem in the steady state, the combined SM-PI control strategy is derived with fuzzy control, where the SM control is responsive during the transient state while the PI control prevails in the steady state. The combination of SSPSM and the SM-PI control provides ZVS operation, robustness and a fast transient response against step load variations. Simulation and experimental results validate the theoretical analysis and the attractive features of the proposed scheme.

Coaxial-type Transient Voltage Suppressor for Antenna Circuit Protection (안테나용 동축형 과도전압 차단장치)

  • 송재용;이종혁;길경석;배정철
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.489-492
    • /
    • 2000
  • This paper describes a new transient voltage suppressor(TVS) with a low insertion loss and a very wide frequency bandwidth to protect antenna circuit from transient voltages. Conventional protection devices have some problems such as low frequency bandwidth and high insertion loss. In order to improve these limitations, a coaxal type TVS, which consists of a gas tube is developed. The performance of the proposed transient voltage suppressor is tested by using a combination surge generator specified in IEC 61000-4-5 standard and by using a network analyzer of 40 MHz ∼ 5GHz bandwidth. From the experimental results, it is confirmed that the proposed TVS has an enough protection performance in low insertion loss and in wide frequency bandwidth

  • PDF

The Trap Characteristics of SILC in Silicon Oxide for SoC

  • Kang C. S.
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.209-212
    • /
    • 2004
  • In this paper, The stress induced leakage currents of thin silicon oxides is investigated in the nano scale structure implementation for Soc. The stress and transient currents associated with the on and off time of applied voltage were used to measure the distribution of high voltage stress induced traps in thin silicon oxide films. The stress and transient currents were due to the charging and discharging of traps generated by high stress voltage in the silicon oxides. The channel current for the thickness dependence of stress current, transient current, and stress induced leakage currents has been measured in oxides with thicknesses between $41\square\;and\;113.4\square,$ which have the channel width x length 10x1um, respectively. The stress induced leakage currents will affect data retention and the stress current, transient current is used to estimate to fundamental limitations on oxide thicknesses. The weight value of synapse transistor was caused by the bias conditions. Excitatory state and inhitory state according to weighted values affected the channel current. The stress induced leakage currents affected excitatory state and inhitory state.

  • PDF

Coordinated Control Strategy for Power Systems with Wind Farms Integration Based on Phase-plane Trajectory

  • Zeng, Yuan;Yang, Yang;Qin, Chao;Chang, Jiangtao;Zhang, Jian;Tu, Jingzhe
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.20-29
    • /
    • 2018
  • The dynamic characteristics of power systems become more and more complex because of the integration of large-scale wind power, which needs appropriate control strategy to guarantee stable operation. With wide area measurement system(WAMS) creating conditions for realizing realt-ime transient stability analysis, a new coordinated control strategy for power system transient stability control based on phase-plane trajectory was proposed. When the outputs of the wind farms change, the proposed control method is capable of selecting optimal generators to balance the deviation of wind power and prevent transient instability. With small disturbance on the base operating point, the coordinated sensitivity of each synchronous generator is obtained. Then the priority matrix can be formed by sorting the coordinated sensitivity in ascending order. Based on the real-time output change of wind farm, coordinated generators can be selected to accomplish the coordinated control with wind farms. The results in New England 10-genrator 39-bus system validate the effectiveness and superiority of the proposed coordinated control strategy.

A Novel SIME Configuration Scheme Correlating Generator Tripping for Transient Stability Assessment

  • Oh, Seung-Chan;Lee, Hwan-Ik;Lee, Yun-Hwan;Lee, Byong-Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1798-1806
    • /
    • 2018
  • When a contingency occurs in a large transmission route in a power system, it can generate various instabilities that may lead to a power system blackout. In particular, transient instability in a power system needs to be immediately addressed, and preventive measures should be in place prior to fault occurrence. Measures to achieve transient stability include system reinforcement, power generation restriction, and generator tripping. Because the interpretation of transient stability is a time domain simulation, it is difficult to determine the efficacy of proposed countermeasures using only simple simulation results. Therefore, several methods to quantify transient stability have been introduced. Among them, the single machine equivalent (SIME) method based on the equal area criterion (EAC) can quantify the degree of instability by calculating the residual acceleration energy of a generator. However, method for generator tripping effect evaluation does not have been established. In this study, we propose a method to evaluate the effect of generator tripping on transient stability that is based on the SIME method. For this purpose, the measures that reflect generator tripping in the SIME calculation are reviewed. Simulation results obtained by applying the proposed method to the IEEE 39-bus system and KEPCO system are then presented.