• Title/Summary/Keyword: transformer noise

Search Result 205, Processing Time 0.035 seconds

Application of Technique Discrete Wavelet Transform for Acoustic Emission Signals (음향방출신호에 대한 이산웨이블릿 변환기법의 적용)

  • 박재준;김면수;김민수;김진승;백관현;송영철;김성홍;권동진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.585-591
    • /
    • 2000
  • The wavelet transform is the most recent technique for processing signals with time-varying spectra. In this paper, the wavelet transform is utilized to improved the assessment and multi-resolution analysis of acoustic emission signals generating in partial discharge. This paper especially deals with the assessment of process statistical parameter using the features extracted from the wavelet coefficients of measured acoustic emission signals in case of applied voltage 20[kv]. Since the parameter assessment using all wavelet coefficients will often turn out leads to inefficient or inaccurate results, we selected that level-3 stage of multi decomposition in discrete wavelet transform. We applied FIR(Finite Impulse Response)digital filter algorithm in discrete to suppression for random noise. The white noise be included high frequency component denoised as decomposition of discrete wavelet transform level-3. We make use of the feature extraction parameter namely, maximum value of acoustic emission signal, average value, dispersion, skewness, kurtosis, etc. The effectiveness of this new method has been verified on ability a diagnosis transformer go through feature extraction in stage of acting(the early period, the last period) .

  • PDF

Considerations on the TF Anal,ysis using Partial Discharge Pulse Characteristics in Oil (유중 부분방전 펄스 특성을 이용한 TF 분석에 대한 고찰)

  • Kim, Jeong-Tae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.508-514
    • /
    • 2005
  • In this paper, it was investigated the characteristics of PD(partial discharge) pulse shapes in oil and the possibility of TF(Time-Frequency) analysis for the discrimination of air corona in on-site PD measurement of oil transformers. For the purpose, single and multiple discharges combined with oil discharges and air corona were generated and measured by use of artificial models through the HFPD pulse detector and the oscilloscope. PD pulse shapes were different according to the type of defects, especially including air corona- pulses. Also, through the TF analysis, data clusters could be classified each other in the TF Map, even in the case of multiple discharges. Therefore, it is known that TF analysis could be aprlied for the improvement of on-site PD measurement in oil transformers.

A Study on the Performance-Improvement of TIG Welder with IGBT Inverter System. (IGBT 인버터제어 TIG용접기 성능개선에 관한 연구)

  • Lee, J.H.;Kim, J.M.;Kim, Y.C.;Won, C.Y.;Kim, G.S.;Kim, Y.R.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2155-2158
    • /
    • 1997
  • This paper describes the performance improvement of dc TIG (Tungsten Inert Gas) welder. The TIG welder consists of single phase full bridge IGBT inverter which incorporates the high frequency transformer, the boost converter for improving the input power factor, and the arc start system. The arc will be generated without fail even when the extension cable between the torch and the power source is 100m long. In addition, the arc start system with a short dc output voltage will generate less EMI noise than the traditional arc start system with a high frequency output voltage. To demonstrate the practical significance of the proposed methods, some simulation studies are presented.

  • PDF

A Quadrature VCO Exploiting Direct Back-Gate Second Harmonic Coupling

  • Oh, Nam-Jin
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.3
    • /
    • pp.134-137
    • /
    • 2008
  • This paper proposes a novel quadrature VCO(QVCO) based on direct back-gate second harmonic coupling. The QVCO directly couples the current sources of the conventional LC VCOs through the back-gate instead of front-gate to generate quadrature signals. By the second harmonic injection locking, the two LC VCOs can generate quadrature signals without using on-chip transformer, or stability problem that is inherent in the direct front-gate second harmonic coupling. The proposed QVCO is implemented in $0.18{\mu}m$ CMOS technology operating at 2 GHz with 5.0 mA core current consumption from 1.8 V power supply. The measured phase noise of the proposed QVCO is - 63 dBc/Hz at 10 kHz offset, -95 dBc/Hz at 100 kHz offset, and -116 dBc/Hz at 1 MHz offset from the 2 GHz output frequency, respectively. The calculated figure of merit(FOM) is about -174 dBc/Hz at 1 MHz offset. The measured image band rejection is 46 dB which corresponds to the phase error of $0.6^{\circ}$.

A Study on DC-DC Converter for X-Ray Using Soft-Switching Method (소프트 스위칭 방식을 이용한 X-Ray용 DC-DC Converter에 관한 연구)

  • Kim, Hack-Seong;Kim, Hyen-Joon;Won, Chung-Yuen;Yoo, Dong-Wook;Ha, Sung-Woon
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.379-381
    • /
    • 1994
  • This paper is concerned with a zero-voltage soft-switching PWM DC-DC high-pelter converter using IGBTs, which Bakes the most of the parastic LC parameters of high-voltage transformer link, for diagnostic X-Ray power generator. The converter circuit basically utilizes phase-shift pulse width modulated series resonant full-bridge PWM DC-DC high-Power converter operating at a constant frequency:20kHz. This technique brings about dramatic decreases in the switching losses of power devices and their electrical stresses as compared with the commonly-used hard-switching PWM DC-DC power converter. The high-frequency switching operation of the converters has some effective advantages, which consist in the physical reduction in size and weight and lowered acoustic noise.

  • PDF

Study on Development of Insulation Degradation Diagnosis System for Electrical Transformer (변압기 절연열화진단 시스템개발에 관한 고찰)

  • 김이곤;유권종;김서영;조용섭;박봉서;최시영;심상욱
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.139-144
    • /
    • 2001
  • Insulation aging diagnosis system provides early warning regarding electrical equipment defect. Early warning is very important in that it can avoid great losses resulting from unexpected shutdown of the production line. Since relations of insulation aging and partial discharge dynamics are non-linear, it is very difficult to provide early warning in an electrical equipment. In this paper, we propose the design method of insulation aging diagnosis system that use a magnetic wave and acoustic signal to diagnoses an electrical equipment. Proposed system measures the partial discharge on-line from DAS(Data Acquisition System) and acquires 2D patterns from analyzing it. For filtering the noise contained in sensor signals we used ICA algorithms. Using this data, design of the neuro-fuzzy model that diagnoses an electrical equipment is investigated. Validity of the new method is asserted by numerical simulation.

  • PDF

A Inverter Design of Reversible Power Converter (가역 전력변환기의 인버터 설계)

  • Chun, J.H.;Lee, H.W.;Baek, S.H.;Kwak, D.K.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.8-13
    • /
    • 2005
  • In this paper discusses single-phase DC-AC Inverter design of reversible power converter that driven by binary combination at different transformer winding ratio by BCD code level. It has a advantage that constructs a control system simply and obtain load current of good quality without filter circuit and free from noise or isolation for lower switching frequency. In this research, study on current type converter and inverter circuit that consist for possibility of AC-DC/DC-AC multi-level reversible converter.

  • PDF

UHF Noise leakage characteristics of power transformer (전력용 변압기의 극초단파 대역 외부잡음 유입 특성 측정)

  • Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2031_2032
    • /
    • 2009
  • 가스절연개폐장치(GIS)에 적용하고 있는 극초단파(Ultra High Frequency, UHF) 전자기파 부분방전 측정기술을 전력용 변압기 분야에 적용하는데 외부잡음 유입특성을 고려하여야 한다. 부싱을 통하여 부분방전 신호 이외의 외부잡음의 유입가능성이 크다. 따라서 본 논문에서는 현장에 설치 운전중인 154kV 변압기에 UHF 센서를 설치하여 부싱을 통해 유입되는 외부잡음을 0~2GHz 의 주파수영역에서 측정 하였다.

  • PDF

Study of ZVS-PWM Series Resonant Converter with Active-Clamp Technique (액티브 클램프 기법을 이용한 영전압 스위칭 직렬 공진형 컨버터에 관한 연구)

  • Jeon, Hee-Cheol;Kim, Yong;Jung, Kye-Cheon;Kim, Pil-Soo;Lee, Eun-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2674-2677
    • /
    • 1999
  • Resonant converters have several salient features such as high efficiency and low noise. Therefore, ZVS-PWM controlled series resonant converter with active-clamp technique is presented. The combination of an active-clamp technique and resonant circuit makes it possible to control the output voltage of the resonant converter with PWM. This new resonant converter was implemented and has achieved a good controllability. In this paper, the normal load characteristics and abnormal voltage increase in the case of the light load are analyzed. As a result, it is clarified that the stray capacitance of the transformer is a cause of the abnormal voltage increase. Then, it is confirmed that the abnormal voltage increase is suppressed by decreasing the duty ratio. ZVS condition is analyzed. The maximum efficiency of 89% is obtained for the output of 10V and 5A.

  • PDF

A Study on Performance Improvement of Optical Current Transformer and Signal Processor (벌크형 광 CT 센서 및 신호처리부 성능 개선 방안 연구)

  • Kim, Young-Soo;Park, Byung-Seok;Kim, Myong-Soo;Lim, Yong-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1929-1932
    • /
    • 2002
  • In this paper, some parameters are studied for the performance improvement of a bulk optical current sensor. The performance of optical current sensor is influenced by current measuring range, Verdet constant change due to temperature change, temperature variation of wave plate, signal to noise ratio of optical transmitter/receiver, optical bias mismatch. Two types of optical current sensors are implemented and tested in the current range from 10 ampere to 200 ampere.

  • PDF