• Title/Summary/Keyword: transformer noise

Search Result 204, Processing Time 0.025 seconds

Noise Reduction Performance of a Reactive type Silencer with Perforated Panels (다공판이 내장된 반사형 소음기의 소음저감 성능)

  • Lee, Sun-Ki;Lee, Young-Chul;Song, Hwa-Young;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1415-1418
    • /
    • 2007
  • When a high voltage COS fuse becomes a short circuit by the over current, the impulse noise over 150 dB(A) with the strong pulse jet is radiated from the COS fuse of an electric transformer. For the purpose of the impulse noise reduction, in this study, a reactive type silencer with perforated panels are considered. The transmission loss of the silencer are calculated by transfer matrix method. The effect of the porosity, the distance between panels, and the number of perforated panel on the sound transmission loss is investigated and discussed.

  • PDF

Reduction of Radiated Noise of EMI using Shielding Methods of High Frequency Transformer (고주파 변압기 차폐에 따른 EMI 방사 노이즈 저감에 관한 연구)

  • Lee Wan-Yun;Chung Gyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.811-814
    • /
    • 2004
  • Radiated noise from high frequency transformers (HTFs) of switching mode power supply is mainly caused by the leakage inductance and the parasitic capacitance of HTFs. Generally, the radiated noise can be reduced by adding snubbers to switching power circuits or shielding HTFs. Radiated noise, however, is mainly affected by the shielding method. In this paper, the various shielding methods to reduce the radiated noise of EMI are analyzed, compared in the experimental studies. And it is proved that the radiated noise can be reduced according to the shielding methods of HFTs and the electrical connection between shields and power circuit.

  • PDF

Noise Reduction of PDP Module (PDP 모듈의 소음 저감)

  • Park, Sooyong;Lee, Seokyeong;Jaeman Joo;Junghun Kang;Sangkyoung O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.326.2-326
    • /
    • 2002
  • A PDP(Plasma Display Panel) module consists of a discharge panel, a SMPS for power supply, driving boards for panel control, and a logic board. Driving boards supply high voltage pulses to induce glow dischargein the PDP panel. The electrical pulses excite the circuit elements and subsequentlyacoustic noises. The main sources of the noise in the circuit are the transformer of SMPS and the power MOSFET of driving boards, and the heat sinks often amplify the noise level. (omitted)

  • PDF

A Development of COS Holder to Reduce an Impact Ambient Noise (충격성 소음 감소용 COS 홀더 개발)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.5
    • /
    • pp.1062-1068
    • /
    • 2007
  • We are using COS to block the excess current and to protect the transformer. But the fuse of COS is melt due to the overload resulting from the excess current flows and it destroys an air severing relations to clear as strong arc happens. Such phenomenon induces an impact ambient noise and it gives the circumstance area resident or pedestrian the fear. Thus, it is necessary that we urgently need to control the ambient noise from the actual circumstances. In this study, we investigate the characteristic of an impact ambient noise associate with the melting state of the COS fuse and suggest the method to reduce the noise.

  • PDF

Soft-Switched PWM DC-DC High-Power Converter with Quasi Resonant-Poles and Parasitic Reactive Resonant Components of High-Voltage Transformer (부분 공진형 소프트 스위칭 PWM DC-DC 고전압 컨버터)

  • 김용주;신대철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.384-394
    • /
    • 1999
  • This paper deals with a fixed frequency full-bridge inverter type DC-DC high-power converter with high frequency high voltage(HFHV) transformer-coupled stage, which operates under quasi-resonant ZVS transition priciple in spite of a wide PWM-based voltage regulation processing and largely-changed load conditions. This multi-resonant(MR) converter topology is composed of a series capacitor-connected parallel resonant tank which makes the most of parasitic circuit reactive components of HFHV transformer and two additional quasi-resonant pole circuits incorporated into the bridge legs. The soft-switching operation and practical efficacy of this new converter circuit using the latest IGBTs are actually ascertained through 50kV trially-produced converter system operating using 20kHz/30kHz high voltage(HV) transformers which is applied for driving the diagnostic HV X-ray tube load in medical equipments. It is proved from a practical point of view that the switching losses of IGBTs and their electrical dynamic stresses relating to EMI noise can be considerably reduced under a high frequency(HF) switching-based phase-shift PWM control process for a load setting requirements.

  • PDF

Zero-Voltage Switching Two-Transformer Full-Bridge PWM Converter With Lossless Diode-Clamp Rectifier (새로운 무 손실 다이오드 클램프 회로를 채택한 두 개의 트랜스포머를 갖는 영 전압 스위칭 풀 브릿지 컨버터)

  • Yoon H. K.;Han S. K.;Park J. S.;Moon G. W.;Youn M. J.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.551-555
    • /
    • 2004
  • The two-transformer full bridge (TTFB) PWM converter has two transformers which act as the output inductor as well as the main transformer, i.e. as the forward and the flyback transformer. Although the doubled leakage inductor of the TTFB makes it easier to achieve the zero-voltage switching (ZVS) of the lagging leg switch along the wide load range, it instigates a serious voltage ringing in the secondary rectifier diodes, which would require the dissipative snubber circuit, cause the serious power dissipation, and increase the voltage stress across those diodes. To overcome these problems, a, new lossless diode-clamp rectifier (LDCR) is employed as the output rectifier, which helps the voltage across rectifier diodes to be clamped on a half the output voltage $(V_o/2)$ or the output voltage $(V_o)$. Therefore, no dissipative snubber for rectifier diodes is needed and a high efficiency as well as low noise output voltage can be realized. The operations, analysis and design consideration of proposed converter are presented in this paper. To verify the validity of the proposed converter, experimental results from a 425W, 385-170Vdc prototype for the plasma display panel (PDP) sustaining power module (PSPM) are presented.

  • PDF

Optimal Design of Ultrasonic Horn for Ultrasonic Drilling Processing of Ceramic Material (세라믹 소재 초음파 드릴링 가공을 위한 초음파 Horn의 최적 설계에 관한 연구)

  • Cha, Seung-hwan;Yang, Dong-ho;Lee, Sang-hyeop;Lee, Jong-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.9
    • /
    • pp.1-11
    • /
    • 2022
  • Recently, there has been continuous technological development in the semiconductor industry, and semiconductor manufacturing technologies are being advanced and highly integrated. For this reason, ceramic material having excellent heat resistance, wear resistance, and conductivity are used as components in semiconductor manufacturing. Among them, the probe card's space transformer is used as ceramic material to prevent electronic signal noise during the electrical die sorting of semiconductor function testing. However, implementing a bulk-type space transformer with a thickness of 5.6 mm or more is challenging, and thus it is produced in a structure with a stacked ceramic film. The stacked space transformer has low productivity because it is difficult to ensure hole clogging and a precise shape. In this research, an ultrasonic horn is designed to manufacture a bulk-type ceramic space transformer through ultrasonic drilling. Vibration characteristics were analyzed according to the ultrasonic horn, and the natural frequency was measured.

Unleashing the Potential of Vision Transformer for Automated Bone Age Assessment in Hand X-rays (자동 뼈 연령 평가를 위한 비전 트랜스포머와 손 X 선 영상 분석)

  • Kyunghee Jung;Sammy Yap Xiang Bang;Nguyen Duc Toan;Hyunseung Choo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.05a
    • /
    • pp.687-688
    • /
    • 2023
  • Bone age assessment is a crucial task in pediatric radiology for assessing growth and development in children. In this paper, we explore the potential of Vision Transformer, a state-of-the-art deep learning model, for bone age assessment using X-ray images. We generate heatmap outputs using a pre-trained Vision Transformer model on a publicly available dataset of hand X-ray images and show that the model tends to focus on the overall hand and only the bone part of the image, indicating its potential for accurately identifying the regions of interest for bone age assessment without the need for pre-processing to remove background noise. We also suggest two methods for extracting the region of interest from the heatmap output. Our study suggests that Vision Transformer holds great potential for bone age assessment using X-ray images, as it can provide accurate and interpretable output that may assist radiologists in identifying potential abnormalities or areas of interest in the X-ray image.

A Development of COS Fuse Holder to Reduce an Impact Ambient Noise (충격성소음저감용 COS 휴즈 홀더 개발)

  • Cho, Hyun-Seob;Min, Jin-Kyoung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.11a
    • /
    • pp.176-179
    • /
    • 2006
  • We are using COS to purpose blocking the excess current and to protect the transformer. But the fuse of COS is melt due to the overload if the excess current flows and it destroy an air severing relations to clear as strong arc happens. Such phenomenon induces an impact ambient noise and it gives the circumstance area resident or pedestrian the fear. Thus, We are the actual circumstances which an ambient noise countermeasure establishment have desired urgently. In this study, we grasp the characteristic of an impact ambient noise which a COS fuse happens the melting and study the method to reduce an impact ambient noise.

  • PDF