• 제목/요약/키워드: transfer impedance

검색결과 363건 처리시간 0.029초

최소 위상 조건을 적용한 음향 임피던스 측정 (Application of Minimum Phase Condition to Acoustic Impedance Measurement)

  • 임병덕;허준혁
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.855-860
    • /
    • 2005
  • For the accurate measurement of acoustic properties of a surface, efforts have been made to reduce errors caused by external disturbance. If the reflection coefficient is considered as a transfer function between reflected wave and incident wave, causality is required between them and the reflection coefficient should be of minimum phase. In this thesis, the minimum phase condition is applied to measure correct reflection coefficient. The reflection coefficient is approximated as a rational function in the Z domain by minimizing the sum square error. Then the minimum phase reflection coefficient is reconstructed using the distribution of poles and zeros of the reflection coefficient model. The incident wave, the reflected wave and the impulse response function of causality are recalculated from the minimum phase reflection coefficient for further applications.

  • PDF

구형 혼안테나에 인접된 전송선로에 유기되는 부하전류 및 EMI 특성 해석 (An Analysis of EMI Characteristics and the Induced Load Current on th Transmission Line Being Close to the Rectangular Horn Antenna)

  • 양두영;채관수;이상설
    • 한국통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.335-341
    • /
    • 1991
  • 구형 혼안테나에 의한 EMI문제를 해결하기 위하여 근거리 영역에 대한 복사 전자계식을 세운다. 전자계 해석 방법과 전송선이론을 적용하여 인접한 전송선 부하에 흐르는 EMI 부하전류를 계산한다. 거리와 주파수 및 송, 수전단 임피던스에 따른 부하전류 전달함수로 부터 EMI의 최소화조건을 찾아낸다. 송전단 임피던스가 작아질수록 EMI 부하전류는 커지고 송전단 임피던스가 커질수록 EMI 부하전류는 작아진다.

  • PDF

전달손실계수 측정 시스템에 대하여 (On the Transmission Loss Measurement System)

  • 류윤선;김윤석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.166-171
    • /
    • 2002
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the transmission loss coefficient measurement system using 4-microphone impedance tube is proposed, based on the idea calculating the full transfer matrix of the acoustical sample to test. The theoretical background and measurement system are introduced, and finally the measurement results are verified.

  • PDF

Electrochemical Study of Poly(aniline N-alkylsulfonate)s

  • Kim, Eunkyoung;Rhee, Suh Bong
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.631-636
    • /
    • 1995
  • Electrochemical properties of self-dopable poly(aniline N-butylsulfonate)s in various acidic medium were investigated by spectroelectrochemical techniques. Cyclic voltammetric study showed more than two reversible process of one electron transfer, the potential and peak intensity of which were dependent on the acid concentration and dopant ion. Spectroscopic study at different oxidation level indicated that the electrochromic switching of the poly(aniline N-alkylsulfonate)s film involves structural changes from benzenoid ring to quinoid ring. Spectrocyclic voltammetry together with impedance spectra of the PANBUS film in 0.1 M $LiClO_4$ solution of acetonitrile containing 0.46 M of perchloric acid showed two types of highly conductive states at the intermediate oxidation levels, which can be related to the metallic polaron states doped by two different process.

  • PDF

폴리피롤 첨가에 의한 supercapacitor용 저 임피던스 전극 (Electrode of Low Impedance by Polypyrrole Addition for Supercapacitor)

  • 김경민;장인영;강안수
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2003년도 추계학술대회
    • /
    • pp.343-350
    • /
    • 2003
  • The best Ppy weight ratio was 7 wt% and the optimal electrode composition ratio was 78 : 17 : 5 wt.% of (MSP-20 : BP-20 =1 : 1), (Super P : Ppy =10 : 7) and P(VdF-co-HFP). Implantation of Ppy as the conducting agents have led to superior electrochemical characteristics because of the low of internal resistance and faradaic capacitance. The result of unit cell with Ppy 7 wt% were as follows: 28.02 Fig of specific capacitance, 1.34 Ω of DC-ESR and 0.36 Ω of AC-ESR. Unit cell showed a good stability up to 200 charge-discharge cycles, retaining 82% of their original capacity at 200 cycles. From the analysis of impedance, the electrodes with Ppy 7 wt% showed low ESR, low charge transfer resistance and quick reaction rate. It was inferred that quick charge-discharge was possible. As compared with the specific capacitance (rectangular shape) of CV, it was also concluded that the specific capacitance originated from thecompound phenomena of the faradaic capacitance by oxidation and reduction of Ppy and the non-faradaic capacitance by adsorption-desorption of activated carbon.

  • PDF

전달손실계수 측정 시스템에 대하여(Part II) (On the Transmission Loss Measurement System(Part II))

  • 김윤석;류윤선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.658-661
    • /
    • 2003
  • The transmission loss coefficient is very important acoustic property in parallel with absorption and acoustic impedance categorizing the acoustical materials, which can control the acoustical problems. At the same time, the transmission loss coefficient is a key parameter to choose the optimum material for the analysis of acoustical characteristics of material using SEA(Statistical Energy Analysis). In this paper, the transmission loss coefficient measurement system using 4-microphone impedance tube is proposed, based on the idea calculating the full transfer matrix of the acoustical sample to test. The theoretical background and measurement system are introduced, and finally the measurement results are verified.

  • PDF

2 포트 VNA를 이용한 멀티포트 5-parameter 변환에 관한 연구 (Transfer characteristics measurement of multi-port system using two-port Network Analyzer)

  • 김종민;황보훈;심민규;설병수;이종성;이형석;나완수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.137-138
    • /
    • 2006
  • In this paper, we study the algorithm for the multiport measurements using the 2port VNA(Vector network Analyzer). We explain the conversion algorithm which the open impedance to the matched impedance(50 ohm), and then we apply this algorithm to the 4 port VNA measurement. Finally, we discuss the reliability of this algorithm.

  • PDF

ECR장치의 임피던스 매칭회로 설계 (ECR device impedance matching circuit design)

  • 김성완;김창선
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.445-446
    • /
    • 2012
  • Recently the interest in wireless power transfer have been studied. ECR (Electromagnetic Coupled Resonance) device, depending on the size of the frequency characteristics of the structure, increasing in volume and larger volume of wireless power transmission device to make use of ECR is a big barrier. So to solve this problem for ECR device miniaturization and high efficiency has been actively studied. In this paper, the size of the device for ECR IM (Impedance Matching) by applying a one-turn coil circuit, remove the device in the form of ECR Network Analyzer measured by removing the one-turn coil has demonstrated the possibility of the device in the form of ECR.

  • PDF

TWO TYPES OF ACTIVE NOISE CONTROL SYSTEM USING MFB LOUDSPEAKER

  • Nishimura, Yoshitaka;Shimada, Yasuyuki;Usagawa, Tsuyoshi;Ebata, Masanao
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.764-769
    • /
    • 1994
  • The impedance of an electro-acoustic transducer can be controlled by motional feedback, and the noise in a duct can be reduced actively by adjusting the impedance using an additional sound. In this paper, two approaches for active noise control using motional feedback (MFB) loudspeaker are described. First configuration uses an external sensor to pickup of source directly. In this configuration, the adaptation of controller is necessary to compensate the change of transfer function from noise source to control poing. The second configuration uses a new adaptive algorithm specialized for peridic noise. Because this configuration does not require any reference input and the error sensor couples very tightly with control loudspeaker, this MFB system itself is independent of the duct condition. No microphone are required in both configurations, so that a more reliable and stable active control system can be realized under severe conditions such as high pressure, high temperature, dust, flow and so on.

  • PDF

Efficiency Enhancement of Wireless Power Transfer with Optimum Coupling Mechanism for Mid-range Operation

  • Anowar, Tanbir Ibne;Kumar, Narendra;Ramiah, Harikrishnan;Reza, Ahmed Wasif
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1556-1565
    • /
    • 2017
  • This paper depicts the design, implementation and analysis of efficient resonant based wireless power transfer (WPT) technique using three magnetic coupled coils. This work is suitable for mid ranged device due to small form factor while minimizing the loading effect. A multi turned loop size resonator is exploited for both the transmitter and receiver for longer distance. In this paper, class-E power amplifier (class-E PA) is introduced with an optimum power tracking mechanism of WPT system to enhance the power capability at mid-range with a flat gain. A robust method of finding optimum distance is derived with an experimental analysis of the designed system. In this method, the load sensitive issue of WPT is resolved by tuning coupling coefficient at considerable distances. Our designed PA with a drain efficiency of 77.8% for a maximum output of 5W is used with adopted tuning technique that improves the overall WPT system performance by 3 dB at various operating points.