• 제목/요약/키워드: transducer design

Search Result 383, Processing Time 0.03 seconds

Design of a Ka-Band Orthomode Transducer (Ka-대역 직교모드변환기 설계)

  • 이종경;채범용;박동희;안병철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.1
    • /
    • pp.110-118
    • /
    • 2004
  • In this paper, a method is presented for the design of an orthomode transducer(OMT) operating at 21/31GHz frequency bands. A square waveguide is used in the common port while the WR-34 standard rectangular waveguide is used in the straight port. The straight port is connected to the common port via a multi-stage quarter-wave impedance transformer. The side port is coupled to the common port through a slot formed along the center line of the common square waveguide. An impedance transformer is employed to match the impedance of the coupling slot with that of the WR-51 waveguide at the output of the side port. Dimensions of the OMT are iteratively optimized employing the theory of waveguide. The validity of the proposed method is verified by fabricating and testing the designed orthomode transducer.

Directivity Analysis for Optimal Design of Ultrasonic Angle Beam Transducer (초음파 사각 트랜스듀서의 최적설계를 위한 지향성 해석)

  • Nam, Young-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.796-803
    • /
    • 2008
  • Ultrasonic testing uses the directivity of the ultrasonic wave, which propagates in on direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of an ultrasonic wave is related to the choice of probe arrangement, testing sensitivity and scanning pitch and correct measurement of defect size and location. This paper describes on the directivity measurement of ultrasonic wave using the visualization method. The directivity of shear wave emitted from the angle beam transducer were constant during propagation. The difference of directivity was existed between 2 MHz and 4 MHz angle beam transducers. When these experimental results were compared with the theory which was based on the continuous wave, it showed good agreement with theoretical directivity on the principal lobe.

Design of Acoustic Element and Case for the Piezoelectric Acoustic Transducer (압전형 음향변환기용 음향소자 및 케이스의 설계)

  • 김현철;고영준;박재성;남효덕;장호경
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.711-714
    • /
    • 2000
  • In this study, the physical properties of the acoustic element and case with metal-piezoelectric ceramics were analyzed. The dielectric and piezoelectric properties of 0.5 wt% MnO$_2$and NiO doped 0.1Pb(Mg$\_$1/3Nb$\_$2/3)O$_3$-0.45PbTiO$_3$-0.45PbZrO$_3$ceramics were investigated aiming at acoustic transducer applications. The vibration characteristics for the laminated circular plate was analyzed for the various thickness and diameter of the piezoceramic layer and metal layer. Also, the acoustic characteristics for the geometrical form of case have been investigated. The design and fabrication method worked in this paper can be utilized in development of actuator and acoustic device.

  • PDF

Design of Mode Transducer between $TE_{10}$ Mode in Rectangular Waveguide and $TE_{11}$ Mode in Circular Waveguide (구형 도파관 $TE_{10}$모드와 원형 도파관 $TE_{11}$모드간의 모드변환기 설계)

  • Doo-Yeong Yang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.3
    • /
    • pp.246-253
    • /
    • 1996
  • In this paper, a problem that occurred in the telegraphist equation established by mode conversion method is solved as analysis tapered transmission line is applied to a waveguide taper. After comparing and analyzing the taper function with variant properties, we select on of taper functions not only that is easily designed but also that have good properties. And then we propose the applicant method to design the waveguide taper and deal with the design of mode transducer between rectangular waveguide and circular waveguide. The measured results of scattering coefficients for the mode transducer fabricated with designed data are agreed well with the theoretical results and the validity of the proposed design and analysis method has been confirmed.

  • PDF

Development of Split-beam Acoustic Transducer for a 50 kHz Fish Sizing Echo Sounder (50 kHz 체장어군탐지기용 분할 빔 음향 변환기의 개발)

  • Lee, Dae-Jae;Lee, Won-Sub
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.4
    • /
    • pp.413-422
    • /
    • 2011
  • An improved split-beam transducer for a 50 kHz fish-sizing echo sounder was developed. The main objective of this study was to minimize the side lobe level in the beam pattern and the distance between acoustic centers for adjacent transducer quadrants in the geometrical arrangement of array elements while maintaining a given number of transducer elements and beam width. To achieve these goals, a 32-element planar array transducer ($6{\times}6$ array with one element in each corner missing) was designed using the Dolph-Chebyshev shading function to suppress side lobes in the array beam pattern and fabricated by arranging the inter-element spacing to be substantially equal to half the wavelength using the transducer element of 0.4 times the wavelength in diameter. The performance characteristics of this split-beam transducer were evaluated in the experimental water tank of $5m{\times}5m{\times}6m$ (length${\times}$height${\times}$width). In this study, the design goal of the beam width and side lobe level for transmitting a beam pattern was initially set at $21^{\circ}$ and -30 dB, respectively. However, the measured beam width at 3 dB was $21^{\circ}$ in both directions with side lobe levels of -24.7 dB in the horizontal plane and -25.6 dB in the vertical plane. The averaged beam width at -3 dB of the receiving beam patterns for four receiving quadrants was $31.4^{\circ}$. The transmitting voltage response was 161.5 dB (re $1{\mu}Pa$/V at 1 m) at 50.23 kHz with a bandwidth of 2.16 kHz, and the averaged receiving sensitivity for four receiving quadrants was -178.13 dB (re 1 V/${\mu}Pa$) at 49.8 kHz with a bandwidth of 2.64 kHz.

A Study on the Cross Talk Level in a Piezoelectric Ultrasonic Array Transducer (압전형 초음파 배열 변환기의 음향간섭 레벨에 관한 연구)

  • 이수성;김영신;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.56-61
    • /
    • 2002
  • In piezoelectric ultrasonic linear array transducers widely used for diagnosis, the cross talk caused by the structural cross-coupling between adjacent elements inside the transducer affects the probe performance in a significant manner. In this study, we constructed a finite element model of a piezoelectric ultrasonic transducer, and analyzed its cross talk level with respect to the shape of and materials inside the kerf, The results of this work can be utilized in optimal design of the transducers for medical diagonosis and treatment as well as W applications.

Noninvasive Detection of Radial Pulse Wave by Fiber-Optic Transducer (광파이버 트랜스듀서에 의한 맥파의 무침습적 검출)

  • 박승환;정동명
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.229-236
    • /
    • 1989
  • This paper describes an idea of design and construction for a radial pulse wave detector, In acquiring arterial pulse signal noninvasively, a new combinational fiber-optic transducer was used which has a detecting part and a sensing part. The mechanism of detecting part is composed of special form of structure that can detect changing pulses in contact with skin, and transmits arterial wall movements to the sensing part. It consists of elastic reflector and optical fibers, which are arranged in a fiber pair. Then, the intensity of the reflected light will be proportional to the displacement changed by inclined reflector. Using this transducer, it expected to make a clinically useful tool for arterial pulse wave diagnosis, especially on the application of "MACK- CHIN" in the field of Korean traditional medicine, since : his transducer has a simple structure and has an easy and clear signal acquisition method.on method.

  • PDF

Design and Acoustic Properties of Piezoelectric Device with the PMN-PT-PZ System (PMN-PT-PZ계를 이용한 압전소자의 설계 및 음향특성)

  • Go, Young-Jun;Seo, Hee-Don;Nam, Hyo-Duk;Chang, Ho-Gyeong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.283-286
    • /
    • 2000
  • In this study, the acoustic transducer of a thin circular disc-type with PZT/Metal was manufactured. The piezoelectric transducer with 200kHz resonance frequency was designed by considering the sharp directivity and the sound pressure. The dielectric and piezoelectric properties of 0.5 weight percent $MnO_2$ and NiO doped $0.1Pb(Mg_{1/3}Nb_{2/3})O_3-0.45PbTiO_3-0.42PbZrO_3$ ceramics were investigated aiming at acoustic transducer applications. Also, the acoustic characteristics of a thin circular disc-type with metal-piezoceramics have been Investigated.

  • PDF

A Study on the Frequency Characteristics of a Class I Flextensional Transducer (Class I Flextensional 변환기의 주파수 특성에 관한 연구)

  • Kang, Kook-Jin;Lee, Young-Jin;Paik, Jong-Hoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.226-227
    • /
    • 2008
  • We constructed a class I Flextensional transducer, and analyzed the variation of the resonance frequency of the transducer in relation to its design variables. We used the FEM for the analysis. Major axis length, minor axis length, thickness and material properties of the shell have large effects on the resonance frequency. In addition, the validation of the FE model was verified by manufacturing and comparison of the impedance analysis.

  • PDF