Analysis of Natural Ventilation Effect of Seoul Metropolitan Subway by Monitoring Indoor $CO_2$ Concentrations (수도권 전동차 객실 $CO_2$농도관측을 통한 자연환기효과 해석)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.965-968
    • /
    • 2007
  • Two major parameters, i.e. carbon dioxide ($CO_2$) and particulate matters smaller than $10{\mu}m\;(PM_{10})$, were selected as the index pollutants in managing indoor air quality. The former pollutant, $CO_2$, is the index that shows the ventilation status and is exhaled by passengers when they breathe in train or subway. It is generally known that high $CO_2$ concentration in the vehicle may be decreased by insufficient air-tightening vehicle bodies and the air is ventilated when vehicles stop at the station and doors open. However, there is no established proof or quantitatively identified data on how much the $CO_2$ concentration is reduced when ventilation is done while doors are opened. In this study, $CO_2$ concentrations were measured in 6 lines of Korail and one line of Seoul Metro subway linesand a theoretical approach was takento predict the changing trend of $CO_2$ concentrations during the operation of vehicle by using $CO_2$ dilution factor through natural ventilation. As a result, the change could be quantified and it was found that app. 35% of indoor $CO_2$ was removed through natural ventilation.

  • PDF

A Study on Monitoring Means of Insulation deterioration of Electric Power Cable (전력케이블 열화 감시방안에 관한 연구)

  • Han, Hag-Su;Min, Kyung-Yun;Ryu, Ki-Son
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1522-1528
    • /
    • 2007
  • Electric Power cable is the apparatus that receives electric power from the Korea Electric Power Corporation and supplies electric power to electric train and annex facilities of each railway station. With substantial ripple effect during power blackout accidents, such power blackout accidents must be coped with by discriminating the status of insulation deterioration of electric power cable in advance. Discrimination of insulation deterioration of the electric power cable is normally executed while the power is disconnected and it is very difficult to discover, at early stage, the insulation deterioration of the power cable in operational state since the duration of inspection is limited. This research aims to consider method of diagnosing the insulation deterioration of electric power cable in On-Line state rather than diagnosis in Off-Line state in order to secure reliability of power supply by reducing duration of power blackout (accidental blackout and blackout during works) and by seeking reduction in equipment and manpower used in diagnosis of deterioration through prevention of the accident itself prior to occurrence through early restoration of accident due to insulation deterioration of the electric power cable and assessment of performance of the cable under operation.

  • PDF

A Study on the Application of Convergence Measurement System to Inverse Calculation of Tunnel Lining Sectional Forces (터널 라이닝 단면력 역산을 위한 유지관리 내공변위계측시스템 적용 연구)

  • 이대혁;김기선;한일영;박연준;유광호
    • Tunnel and Underground Space
    • /
    • v.11 no.2
    • /
    • pp.146-155
    • /
    • 2001
  • An inverse calculation method to obtain sectional forces, axial force and flexural moment of a tunnel concrete lining was developed by utilizing convergence measurements acquired at the maintenance stage. To monitor the behavior of the lining, DOCS system was applied to a subway tunnel section. The method was proved to be effective, yielding the same results as measured forces of buried instruments. Many effects such as vibration of sensors, vibration due to test train operation, the variation of temperature and high voltage were checked and a new management scheme for tunnel maintenance was proposed.

  • PDF

Analysis of Current Collect Performance Depending on Installation Condition of Overhead Contact Line in Suseo High Speed Line (수서고속철도 전차선로의 설치조건의 따른 집전상태 분석)

  • Na, Kyung-min;Park, Young;Lee, Kiwon;Cho, Yong Hyeon;Kwon, Sam-young;Park, Chulmin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.4
    • /
    • pp.727-732
    • /
    • 2017
  • This paper describes the dynamic characteristics depending on installation condition between a pantograph and an OCL (Overhead Contact Line) on a new high speed line in Korea. The current collection performance between the pantograph and the OCL was tested during train operation from Suseo to Jije stations. The current collection performance is evaluated based on the duration of an arc by using an arcing measurement system. The system consists of an optical sensor for measuring the duration of an arc and a camera for monitoring current collection performance. An arcing duration is defined as a percentage of arcing in international standards. This test aims to analyze the locations of repetitive arcing depending on installation conditions of OCLs on a new high speed line in order to use the result as reference data for correct construction and maintenance.

Box Model Approach for Indoor Air Quality (IAQ) Management in a Subway Station Environment

  • Song, Jihan;Pokhrel, Rajib;Lee, Heekwan;Kim, Shin-Do
    • Asian Journal of Atmospheric Environment
    • /
    • v.8 no.4
    • /
    • pp.184-191
    • /
    • 2014
  • Air quality in a subway tunnel has been crucial in most of the subway environments where IAQ could be affected by many factors such as the number of passengers, the amount and types of ventilation, train operation factors and other facilities. A modeling approach has been introduced to manage the general IAQ in a subway station. Field surveys and $CO_2$ measurements were initially conducted to analyze and understand the relationship between indoor and outdoor air quality while considering internal pollution sources, such as passengers and subway trains, etc. The measurement data were then employed for the model development with other statistical information. For the model development, the algorithm of simple continuity was set up and applied to model the subway IAQ concerned, while considering the major air transport through staircases and tunnels. Monitored $CO_2$ concentration on the concourse and platform were correlated with modeling results where the correlation values for the concourse and platform were $R^2=0.96$ and $R^2=0.75$, respectively. It implies that the box modeling approach introduced in this study would be beneficial to predict and control the indoor air quality in subway environments.

Dynamic Analysis of Monorail System with Magnetic Caterpillar (자석식 무한궤도를 가진 모노레일의 동역학 해석)

  • Won, Jong-Sung;Tak, Tae-Oh
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.2
    • /
    • pp.47-55
    • /
    • 2012
  • This work deals with dynamic analysis of a monorail system with magnetic caterpillar where magnets are embedded inside each articulated element of the caterpillar, augmenting traction force of main rubber wheels to climb up slope up to 15 degree grade. Considerations are first given to determine stiffness of the primary and secondary suspension springs in order for the natural frequencies of car body and bogie associated with vertical, pitch, roll and yaw motion to be within generally accepted range of 1-2 Hz. Equations for calculating magnetic force needed to climb up given slope are derived, and a magnetic caterpillar system for 1/6 scale monorail is designed based on the derivation. To assess the hill climbing ability and cornering stability, and make sure smooth operation of the side and vertical guiding wheels which is critical for safety, a multibody model that takes into account of every component level design characteristics of car, bogie, and caterpillar is set up. Through hill climbing simulation and comparison with measurement of the limit slope, the validity of the analysis and design of the magnetic caterpillar system are demonstrated. Also by studying the curving behavior, maximum curving speed without rollover, functioning of lateral motion constraint system, the effects of geometry of guiding rails are studied.

Introduction of the SBE and Its Operation for the Improvement of Field Professional Education (현장실습 교육 활성화를 위한 학교기업 도입과 운영 방안)

  • Oh Kyeung-Heub;Song Chul-Ki
    • Journal of Engineering Education Research
    • /
    • v.8 no.1
    • /
    • pp.60-70
    • /
    • 2005
  • The objective of the field professional education is to train up students with knowledge and technic and to supply them to companies. One of the good methods for the field professional education is to establish the school based enterprise(SBE) in school and university. The SBE program for the field professional education could improve the cooperation between industry and school(or university). In this paper, the foreign SBE programs and the domestic SBE programs are investigated and some improvement are suggested for the technical high schools.

Measurement and Analysis of Ground Borne Vibrations Resulting from Railroad Operation (열차 주행에 의한 지반진동의 계측 및 분석)

  • 목영진
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1993.06a
    • /
    • pp.15-54
    • /
    • 1993
  • Ground Vibrations were measured at one location near the railroad track at a site about 3.2 kilometers north of Chapel Hill, Tennessee, U.S.A., Measurements were made during the passage of 18 freight trains over the six-day period. The objective of this study was to evaluate ground vibration levels from train and other traffic at possible construction depths for the Superconducting Super Collider(SSC), The criterion with which the vibration levels are compared is the more stringent one : that is, 0, 0005 inchs(about 0.0127 m) at 3H2, The measurements show conclusively that vibration levels generated by railroad traffic in the rock at the depth of 100 it (30m) or more are at least 10 times smaller than the criterion.

  • PDF

Performance Characteristics of Louver Dust Collectors (루버 집진기의 성능특성)

  • Woo, Sang-Hee;Kim, Jong Bum;Park, Tong-Il;Yook, Se-Jin;Kwon, Soon Bark;Bae, Gwi-Nam
    • Particle and aerosol research
    • /
    • v.12 no.1
    • /
    • pp.11-20
    • /
    • 2016
  • A large amount of wear dust generated during train operation is a major dust source in urban railway tunnels. To check possibility of a louver dust collector for the removal of dust in the railway tunnel, five louver dust collector models were designed and their performance was tested in a wind tunnel. JIS Z 8901 Class 8 dust was used as a test dust. Pressure drop and particle collection efficiency were evaluated with the face velocity ranging from 1 m/s to 4 m/s. At this low velocity range, particle collection efficiency of the louver dust collector was found to be insensitive to air velocity and design parameters. Pressure drop was under 40 Pa, and $PM_{10}$ and $PM_{2.5}$ collection efficiencies were approximately 50% and 30%, respectively.

The Service Evaluation of Connection and Transfer Facilities in the High-speed Railway Stations (고속철도역의 연계환승시설 서비스 수준 평가)

  • Han, Sung-Yoeb;Kim, Kang-Seob;Park, Min-Kyu;Kim, Si-Gon
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.761-772
    • /
    • 2009
  • The introduction of KTX (Korea Train eXpress) provided passengers with a much faster mode of transport, and KTX has become a model railway system. Express railway stations are emphasized as public transit transfer centers, but their service evaluations were not performed appropriately so far. It is possible to know the level of service by developing valuation criteria for their evaluations. The evaluation of transfer centers mainly consists of two parts; connective service with other travel m odes, and transfer service inside transfer stations. Connection is defined as the inter-connection of multi-transportation vehicles, and transfer means that a passenger changes his travel mode to another. Such connective service and transfer service are evaluated by the level of service in terms of transfer facilities, the appropriateness of station layout and the quality of information throughout the facilities. We developed the service evaluation indicators of connective facilities and referred to the indicators of transfer facilities. We examined the 7 stations in Korea that are currently in operation and standardized the methodology of the evaluation process by applying the indicators suggested in this study.

  • PDF