• Title/Summary/Keyword: trabecular bone

Search Result 309, Processing Time 0.027 seconds

A Microstructural Analysis for Preventive Treatments of Vertebral Fracture (척추 골절의 예방적 치료법에 관한 미세 구조해석)

  • 김형도;탁계래;김한성;이성재
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.146-149
    • /
    • 2002
  • It is reported that the mechanical properties of vertebral trabecular bone depend on the density and the mass of bones. Osteoporosis is a systemic skeletal disease caused by low bone mass and microstructure deterioration of trabecular bone. Silva and Gibson (1997) studied the treatment of age-related bone loss using drug therapy. Vertebroplasty is a minimally invasive surgery for the treatment of osteoporosis vertebrae. This procedure includes puncturing vertebrae and filling with Polymethylmethacrylate (PMMA). However, the relative effect of drug therapy and bone cement for osteoporosis treatment is not reported yet. In this study, several 2D models of human vertebral trabecular bone are analyzed by finite element method. The mechanical behaviors of the vertebral trabecular bone treated by the drug therapy and the bone cement are compared. This study shows that bone cement treatment is more effective strategy than drug therapy to prevent the degradation of bone strength.

  • PDF

Effects of Cheonggukjang and Doenjang on Bone Loss in Ovariectomized Rats

  • Lee, Chang-Hyun;Song, Geun-Seoup;Kim, Young-Soo
    • Food Science and Biotechnology
    • /
    • v.17 no.3
    • /
    • pp.553-557
    • /
    • 2008
  • The effects of cheonggukjang and doenjang on bone mineral density, trabecular area and cortical thickness of the tibia, and serum osteocalcin level in ovariectomized rats were investigated. After 4 weeks, bone mineral density, bone trabecular area, the cortical thickness index, and serum osteocalcin level were analyzed. The cheonggukjang and doenjang diet groups showed significant prevention of ovariectomized (OVX)-related body weight gain. Whole body bone mineral density of the OVX group was significantly lower than that of the sham group, whereas the cheonggulgang and doenjang diets resulted in complete restoration of bone mineral density. Trabecular area in the proximal diaphysis and cortical thickness in the distal diaphysis of the tibia were increased significantly in the cheonggukjang and doenjang diet fed groups. The cheonggukjang and doenjang diets significantly reduced serum osteocalcin level in the OVX rats. These results suggest that cheonggukjang and doenjang might have inhibitory effects on osteoporosis, by showing accelerated bone formation in OVX rats.

Detecting and Tracking Changes of Mechanical Characteristics of the Trabecular and Cortical Bone in the Lumbar Vertebrae of an OVX Rat - Use of In-Vivo Micro-CT and Micro-FE Analysis - (난소 절제술을 시행한 흰쥐 등뼈의 해면골과 피질골의 구조적 특성 추적관찰 및 기계적 특성 분석 - 생체 내 미세단층촬영 시스템과 미세 유한요소법 적용 -)

  • Ko, Chang-Yong;Woo, Dae-Gon;Lee, Tae-Woo;Lee, Beob-Yi;Tack, Gye-Rae;Kim, Han-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.1 s.190
    • /
    • pp.110-117
    • /
    • 2007
  • This study investigated changes of mechanical characteristics of the trabecular and cortical bone in the lumbar vertebrae of the ovariectomised (OVX) rat. In previous researches, there were many studies for morphology of osteoporotic bones based on Micro-Computed Tomography (Micro-CT). However, there were few studies for detecting and tracking changes of mechanical characteristics of the trabecular and cortical bone in the lumbar vertebrae of the OVX rat. For this study, the 4th lumbar of the OVX rat (female Sprague-Dawley) was utilized as a specimen. An OVX rat was scanned at week 0 (just before surgery), at week 4, and week 8 after surgery. Micro-finite element (${\mu}-FE$) analysis was used to investigate mechanical characteristics of the trabecular and cortical bone in the lumbar vertebrae for an OVX rat. When the OVX rat (at week 8) was compared with the OVX rat (at week 0), the structural modulus of cortical and trabecualr bone was decreased by 52% and 99%, respectively. This study showed the change of mechanical characteristics of cortical bone as well as trabecular bone of an OVX rat. Detecting and tracking changes of mechanical characteristics could greatly contribute to an experiment test for the trabecular and cortical bone in the lumbar vertebrae of an OVX rat by using In-vivo Micro-CT.

Effect of Cortical Bone on Acoustic Properties of Trabecular Bone in Bovine Femur In Vitro (생체 외 조건의 소 대퇴골에서 해면질골의 음향특성에 대한 피질골의 효과)

  • Hwang, Kyo Seung;Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.181-189
    • /
    • 2013
  • The purpose of the present study is to investigate the effect of cortical bone on acoustic properties of trabecular bone, such as speed of sound (SOS) and normalized broadband ultrasound attenuation (nBUA), in bovine femur in vitro. Twelve trabecular bone samples and three cortical bone plates with thicknesses of 1.00, 1.47, and 2.00 mm were extracted from the proximal end of two bovine femurs. The correlations between acoustic properties and trabecular apparent bone density were also examined before and after attaching a cortical bone plate to the trabecular bone samples. SOS increased linearly with increasing thickness of the cortical plate attached to one side of ultrasonic incidence of the trabecular bone samples, whereas nBUA showed a nonlinear dependence on the thickness of the cortical plate. All the SOS (r = 0.95-0.97) and nBUA (r = 0.53-0.73) measurements with and without the cortical bone plate with various thicknesses were found to exhibit high correlations with the trabecular apparent bone density. These results imply that the acoustic properties measured in the femur with lateral cortical layers in vitro can be useful indices for the prediction of trabecular bone mineral density.

Choice of Thresholding Technique in Micro-CT Images of Trabecular Bone Does Not Influence the Prediction of Bone Volume Fraction and Apparent Modulus

  • Kim, Chi-Hyun;Kim, Byung-Gwan;Guo, X. Edward
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.174-177
    • /
    • 2007
  • Trabecular bone can be accurately represented using image-based finite element modeling and analysis of these bone models is widely used to predict their mechanical properties. However, the choice of thresholding technique, a necessary step in converting grayscale images to finite element models which can thus significantly influence the structure of the resulting finite element model, is often overlooked. Therefore, we investigated the effects of thresholding techniques on micro-computed tomography (micro-CT) based finite element models of trabecular bone. Three types of thresholding techniques were applied to micro-CT images of trabecular bone which resulted in three unique finite element models for each specimen. Bone volume fractions and apparent moduli were predicted for each model and compared to experimental results. Our findings suggest that predictions of apparent properties agree well with experimental measurements regardless of the choice of thresholding technique in micro CT images of trabecular bone.

Nondestructive Estimation of Mechanical Orthogonality of Human Trabecular Bone by Computed Tomography and Spherical Indentation Test

  • Bae Tae Soo;Lee Tae Soo;Choi Kuiwon
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.2
    • /
    • pp.117-122
    • /
    • 2005
  • The elastic modulus and the apparent density of the trabecular bone were evaluated from spherical indentation tests and Computed Tomography (CT) and their relationship was quantified. The femurs were prepared for trabecular bone analysis. Embedded with respect to their anatomical orientation, the transverse planes of the trabecular bone specimens were scanned at 1㎜ intervals using a CT scanner. The metaphyseal regions of femurs were sectioned with a diamond-blade saw, producing 8㎜ cubes. Using a specially made spherical indentation tester, the cubes were mechanically tested in the anterior-posterior (AP), medial-lateral (ML), and inferior-superior (IS) directions. After determination of modulus from the mechanical testing, the apparent densities of the specimens were measured. The results showed that the IS modulus was significantly greater than both the AP and ML moduli with the AP modulus greater than the ML modulus. This demonstrated that orthogonality was a structural characteristic of the trabecular bone. The power relationship between the modulus and the apparent density was also found to be statistically significant.

Micro-Structural Profiles of Trabecular Bone at the Ankle Joint (족관절 해면골의 미세 구조 분석)

  • Kim, Hyon-Jeong;An, Tae-Sun;Baek, Myong-Hyun;Choi, Mun-Kwon;Won, Ye-Yeon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.8 no.2
    • /
    • pp.157-160
    • /
    • 2004
  • Purpose: This study aimed to investigate and compare the micro-structural profiles of trabecular bone from different facets at the ankle joint. Materials and Methods: In a fresh cadaver ankle, four cored 10 mm of diameter cylindrical specimens of trabecular bone were harvested from the distal tibia, the talar dome, the medial malleolus, and the lateral malleolus. Using a micro-computed tomography, two-dimensional and three-dimensional micro-structural indices of the trabecular bone were analyzed. Results: Each specimen from the tibia, talus, medial malleolus, and the lateral malleolus showed unique micro-structural pattern. Tibia versus talus, the talus was seen a higher bone volume fraction and a wider supporting zone subchondrally whereas the tibia was seen a relatively lower bone volume fraction and a much narrower supporting zone subchondrally. Lateral malleolus versus medial malleolus, the lateral malleolus was seen the thicker but sparse trabeculae pattern whereas the medial malleolus was seen the thinner but more compact trabecular pattern. Conclusion: Each four locations from the different facet at the ankle joint have distinct own micro-structural patterns of the trabecular bone, suggesting different mechanical properties.

  • PDF

The three-dimensional microstructure of trabecular bone: Analysis of site-specific variation in the human jaw bone

  • Kim, Jo-Eun;Shin, Jae-Myung;Oh, Sung-Ook;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul;Huh, Kyung-Hoe
    • Imaging Science in Dentistry
    • /
    • v.43 no.4
    • /
    • pp.227-233
    • /
    • 2013
  • Purpose: This study was performed to analyze human maxillary and mandibular trabecular bone using the data acquired from micro-computed tomography (micro-CT), and to characterize the site-specific microstructures of trabeculae. Materials and Methods: Sixty-nine cylindrical bone specimens were prepared from the mandible and maxilla. They were divided into 5 groups by region: the anterior maxilla, posterior maxilla, anterior mandible, posterior mandible, and mandibular condyle. After the specimens were scanned using a micro-CT system, three-dimensional microstructural parameters such as the percent bone volume, bone specific surface, trabecular thickness, trabecular separation, trabecular number, structure model index, and degrees of anisotropy were analyzed. Results: Among the regions other than the condylar area, the anterior mandibular region showed the highest trabecular thickness and the lowest value for the bone specific surface. On the other hand, the posterior maxilla region showed the lowest trabecular thickness and the highest value for the bone specific surface. The degree of anisotropy was lowest at the anterior mandible. The condyle showed thinner trabeculae with a more anisotropic arrangement than the other mandibular regions. Conclusion: There were microstructural differences between the regions of the maxilla and mandible. These results suggested that different mechanisms of external force might exist at each site.

Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study

  • Tayman, Mahmure Ayse;Kamburoglu, Kivanc;Ocak, Mert;Ozen, Dogukan
    • Imaging Science in Dentistry
    • /
    • v.52 no.2
    • /
    • pp.171-179
    • /
    • 2022
  • Purpose: The aim of this study was to assess the accuracy of cone-beam computed tomographic (CBCT) images obtained using different voxel sizes in measuring trabecular bone microstructure in comparison to micro-CT. Materials and Methods: Twelve human skull bones containing posterior-mandibular alveolar bone regions were analyzed. CBCT images were obtained at voxel sizes of 0.075mm(high: HI) and 0.2mm(standard: Std), while microCT imaging used voxel sizes of 0.06 mm (HI) and 0.12 mm (Std). Analyses were performed using CTAn software with the standardized automatic global threshold method. Intraclass correlation coefficients were used to evaluate the consistency and agreement of paired measurements for bone volume (BV), percent bone volume (BV/TV), bone surface (BS), trabecular thickness (TbTh), trabecular separation (TbSp), trabecular number (TbN), trabecular pattern factor(TbPf), and structure model index (SMI). Results: When compared to micro-CT, CBCT images had higher BV, BV/TV, and TbTh values, while micro-CT images had lower BS, TbSp, TbN, TbPf, and SMI values (P<0.05). The BV, BV/BT, TbTh, and TbSp variables were higher with Std voxels, whereas the BS, TbPf, and SMI variables were higher with HI voxels for both imaging methods. For each imaging modality and voxel size evaluated, BV, BS, and TbTh were significantly different(P<0.05). TbN, TbPf, and SMI showed statistically significant differences between imaging methods(P<0.05). The consistency and absolute agreement between micro-CT and CBCT were excellent for all variables. Conclusion: This study demonstrated the potential of high-resolution CBCT imaging for quantitative bone morphometry assessment.

Estimation of Structural Properties from the Measurements of Phase Velocity and Attenuation Coefficient in Trabecular Bone (해면질골에서 위상속도 및 감쇠계수 측정에 의한 구조적 특성 평가)

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.7
    • /
    • pp.661-667
    • /
    • 2009
  • Trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were used to investigate correlations of phase velocity and attenuation coefficient with structural properties in trabecular bone. Trabecular separation (Tb.Sp) of the 7 trabecular-bone-mimicking phantoms ranged from 300 to $900\;{\mu}m$ and volume fraction (VF) from 1.6% to 8.7%. Phase velocity and attenuation coefficient of the phantoms were measured by using a through-transmission method in water, with a matched pair of broadband unfocused transducers with a diameter of 12.7 mm and a center frequency of 1 MHz. Phase velocity and attenuation coefficient at 1 MHz decreased almost linearly with increasing Tb. Sp and increased almost linearly with increasing VF. The simple and multiple linear regression models with phase velocity and attenuation coefficient as independent vanables and Tb.Sp and VF as dependent variables demonstrated that the coefficients of determination for the prediction of VF were higher than those for the prediction of Tb.Sp. The results obtained in the trabecular-bone-mimicking phantoms consisting of parallel-nylon-wire arrays were consistent with those in human trabecular bone suggesting that the structural properties can be estimated from the measurements of phase velocity and attenuation coefficient in trabecular bone.