• Title/Summary/Keyword: towel tissue

Search Result 7, Processing Time 0.018 seconds

A SPECTROSCOPIC STUDY OF THE OPTICAL PROPERTIES OF VARIOUS PAPERS MADE FROM RECLAIMED FIBRES

  • Ingegerd Forsskahl;Carola Olkkonen;Henrik Tylli
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 1999.04b
    • /
    • pp.296-301
    • /
    • 1999
  • Different papers such as toilet and towel tissue, newsprint and copy paper made from reclaimed fibres were characterized using UV-VIS reflectance and fluorescence spectroscopy. The emission properties of the extracts of the papers were also evaluated. Photochemical irradiation at ambient temperatures, and thermal aging of the copy papers at 105$^{\circ}C$ and 150$^{\circ}C$ were performed. Post-colour numbers (PC) were calculated from the reflectance values measured from the corresponding UV-VIS reflectance spectra. Light absorption coefficient spectra were calculated before and after irradiation, and the changes in absorption coefficient were related to the content of chromophores in the papers. Photochemical and thermal discolouration of the copy papers, similar to that of virgin fibres, was readily observed. The influence of changes in the concentrations of fluorescent brightening agents and dyes on the spectral properties was also assessed. Photostabilization studies of the copy papers were performed with the use of polymer additives polyethylene glycol (PEG) and polytetrahydrofuran (PTHF).

Screening of Tissue Papers for Nematode Extraction for the Baermann Funnel Method (Baermann Funnel법의 선충 분리 여과지 선발)

  • Kang, Heonil;Eun, Geun;Ha, Jihye;Lee, Jaehyun;Kim, Donggeun;Kim, Yongchul;Choi, Insoo
    • Korean journal of applied entomology
    • /
    • v.55 no.4
    • /
    • pp.377-381
    • /
    • 2016
  • The Baermann funnel method requires approximately four Kimwipe tissues for research a nematode count under a stereo microscope. To select more efficient and economical nematode extraction paper for nematode extraction, 15 different kinds of tissue papers were tested and compared with Kimwipe tissues. Nematode species used in the extraction efficiency tests include juvenile (J2) of Heterodera sp., J2 of Meloidogyne sp., Pratylenchus sp., Rhabditis sp., Acrobeloides sp., Panagrolaimus sp., Poikilolaimus sp. and Diplogasterida. The extraction efficiency varied between 42.0 to 88.8%. Considering costs, extraction efficacy, and clarity, the Pulling Kitchen Towel (Monalisa Co., Korea) is the best tissue, with clarity A, isolation efficiency of 69.4% (not significantly different compared to Kimwipe 1 ply 88.8%), and 1/2 costs per isolation of Kimwipe 2 ply.

A Study on the Hygiene Management of Ultrasound Probe (초음파 탐촉자의 위생관리에 관한 연구)

  • Ha, Myeong-Jin;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.87-96
    • /
    • 2020
  • This study examined the hygiene management of ultrasound probes by examining the cleaning tools for hygiene management of ultrasound probes, the presence or absence of wearing glove as a personal protective equipment, and the awareness of ultrasound probe hygiene. Parts 154 questionnaire about people working in the ultrasound room were surveyed and analyzed. The single gel removal tool of the ultrasound probe was most frequently used with a 48.7% cotton towel, and for double gel removal tools, the first gel removal tool was 42.4% cotton towel and the second gel removal tool was used with 57.6% wet tissue. Antimicrobial wipes were the most commonly used drug and instrument used in ultrasound hygiene management at 58.4%. According to the survey of the presence or absence of wearing glove during ultrasound examination, 46.8% were found to be unworn. When examining the intracavity ultrasound, 30.9% of those who do not wear glove and 61.0% of hygiene awareness of ultrasound probes are 'normal'. According to age, ultrasound probe gel removal tool was not significant difference(p>0.05). According to the working organization and the working department, it was significant difference to wearing gloves during ultrasound examination(p<0.05). Therefore, in order to properly sanitize the ultrasound probe, it is considered that a guideline for hygiene management of the ultrasound probe that fits the situation in Korea is necessary, and it is considered that thorough hygiene management training for inspector is necessary for efficient hygiene management of the ultrasound probe.

Development of an Objective Softness Evaluation Method and Its Standardization for Hygiene Paper (위생용지 부드러움의 객관적 평가 방법 개발 및 표준화)

  • Ko, Young Chan;Park, Jong-Moon;Moon, Byoung-Geun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.5
    • /
    • pp.80-84
    • /
    • 2015
  • Softness is considered one of the most important attributes of hygiene paper such as tissue and towel. Being subjective in nature, however, softness attribute has been generally believed to be impossible to evaluate using objective methods. Hallmark in his pioneering work proposed that tissue subjective softness should be mainly consisted of the bulk softness component and surface softness component. The bulk softness component can be determined by tensile stiffness; the surface softness component by surface tester. The surface friction turns out far more important than the surface roughness in determining the surface softness component. It cannot be too much emphasized that both results of the tensile stiffness and the surface friction should depend on measuring conditions such as an instrument used, sample sizes (e.g., basis weight, length, and width) and operating conditions of the instrument (e.g., gauge length, cross-head speed, size of stylus, and its scanning speed). This indicates that a direct comparison of the test results would be impossible or misleading unless they have been tested under the identical conditions. This may explain why the standard objective test method for tissue softness has not been available at present.

Analysis of Replacement Cycle by Eyeglasses Scratches in Daily Life (일상생활 속 안경렌즈 흠집에 의한 교체주기 분석)

  • Jung, Mi-A;Lee, Eun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.12
    • /
    • pp.447-451
    • /
    • 2019
  • This study were to investigate the scratches and replacement cycles of eyeglasses according to personal characteristics in daily life. The subjects were 58 people who voluntarily participated in this study. The replacement cycle of eyeglasses according to the contact of eyelashes with eyeglasses, type and the number of eyeglasses wiped on a day were analyzed. The statistical analysis were performed by X2 test and Fisher's exact test. The average replacement cycle of the eyeglasses were longer females than males. The eyeglasses replacement cycle were significantly shorter when the eyelashes contacted the eyeglasses and when the eyeglasses were wiped using a tissue or clothes other than the eyeglasses towel. The coating film of the eyeglasses may be damaged by the convergence effect such as eyelashes or minor carelessness in daily life, and this study will continue to follow up on this result.

Need Survey of Home Modification on Outpatient with Stroke and Spinal Cord Injury in Rehabilitation Center (재활치료를 받는 뇌졸중과 척추손상 외래환자들의 주거환경개선에 대한 요구도 조사)

  • Lim, Kyung-Min;Lee, Yu-Na
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.324-333
    • /
    • 2013
  • The purpose of this study was to investigate the need of home modification for outpatient with stroke and spinal cord injury. The subjects of this study were 54 outpatients who have experience in rehabilitation therapy at hospitals in Seoul and Gyeonggi-do. A questionnaire was distributed and collected form January 2th to February 4th, 2012. Descriptive statistics and $x^2$-test were used to analyze data. There were statistically significant difference in stairs of access, in width of front door, in bathroom, space of room according diagnosis. There were statistically significant difference in light of sensor, tissue holder and socket cover in bathroom for the comparison of demands for home modification by living type. There were statistically significant difference in width and threshold of front door, tissue holder and towel bar, nonslip floor in bathroom, space and table, chair of kitchen, space and threshold of porch, light for the comparison of demands for home modification according score of MBI. Based on the results of the survey, needs of home modification is different according disability level, diagnosis, living type, ADL performance. The results of this study show a need for the further occupational therapy of home modification and supporting policies in home modification.

Formaldehyde Monitoring of Hygiene Products in Domestic Market (국내 유통 위생용품 중 포름알데히드 잔류량 모니터링)

  • Na, Young-Ran;Kwon, Hyeon-Jeong;Cho, Hyun-Nho;Kim, Hyeon-Jin;Park, Yon-Koung;Park, Sung-Ah;Lee, Seong-Ju;Kang, Jung-Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.225-233
    • /
    • 2020
  • By the standards and specifications for hygiene products, three test methods for formaldehyde are specified for each item type of hygiene product. After derivatization using acetylacetone and 2,4-dinitrophenylhydrazine (2,4-DNPH), formaldehyde is analyzed by spectrophotometer and high-performance liquid chromatography (HPLC). Validation of the three test methods was performed on tissue, diaper lining and waterproof layer, and panty liner products. The results of linearity (R2), limit of detection (LOD), limit of quantification (LOQ), recovery rate (%) and reproducibility (%), showed that all three methods are suitable for analyzing formaldehyde in hygiene products. After derivatization with 2,4-DNPH and cetylacetone, formaldehyde was analyzed at 0, 3, 6, 9, 24 and 48 hours by HPLC. Formaldehyde derivatized with 2,4-DNPH showed no statistically significant change in formaldehyde peak area over time (P>0.05). But, acetylacetone-derivatizated formaldehyde showed a negative correlation coefficient (r) over time (P<0.01). We investigated the residual amounts of formaldehyde in 205 hygiene products distributed in Busan. Among 74 disposable diaper products tested, 73 had low concentrations of formaldehyde (0.13-29.87 mg/kg). Moreover, formaldehyde was not detected in any of 78 tissue, 27 disposable paper towel, 12 disposable dishcloth, 7 paper cup, one brand of paper straw and 6 disposable napkin products.