• 제목/요약/키워드: total efficiency

검색결과 5,609건 처리시간 0.038초

부착증식공정에서 내부 반송율 변화에 따른 생물학적 제거 특성 (Biological Removal Characteristics by the Internal Recycle Rate in the Attached Growth Process)

  • 박충기;김병욱;임재명
    • 환경위생공학
    • /
    • 제14권4호
    • /
    • pp.110-116
    • /
    • 1999
  • This study was conducted to investigate the contaminants removal efficiency and the optimal operating parameters by the internal recycle rate (IRR) in the combining A2/O process with fixed film. The average removal efficiency of BOD and COD was 92.5%~94.6%, 73.9%~87.0% in RUN 1 and 91.9%~94.7%, 77.7%~89.0% in RUN 2, respectively. Organic removal efficiency, at two different hydraulic retention time of 10 and 14hr, was similar. At 50% of the internal recycle rate, organic removal efficiency was somewhat higher than the other. Total nitrogen (T-N) and total phosphorus (T-P) were removed, highly, at 50% of internal recycle rate. It could be suggested by this study that the optimum internal recycle rate is 50% and hydraulic retention time is 14hr.

  • PDF

케이싱 그루브가 존재하는 축류압축기의 성능특성 연구 (A Study on Performance Characteristics of an Axial Compressor with the Casing Groove)

  • 최광진;김진혁;김광용
    • 한국유체기계학회 논문집
    • /
    • 제13권2호
    • /
    • pp.24-29
    • /
    • 2010
  • This paper presents a study on the performance of NASA Rotor 37 with the casing grooves based on three-dimensional numerical analysis. Reynolds-averaged Navier-Stokes equations are solved on a hexahedral grid with the shear stress transport model as a turbulence closure model. The governing equations are discretized by a finite volume method. The validation of the numerical results is performed through experimental data for the total pressure ratio and the adiabatic efficiency. The investigation for an axial compressor with a smooth casing and the casing grooves is carried out to compare the performance parameters, for example, surge margin and efficiency, etc. The surge margin is improved in the case of the casing grooves while remarkable improvement of the efficiency is not produced. The result shows that the casing groove is beneficial to expand the operating range of NASA Rotor 37.

Development of a Highly Efficient Boiler System Using a Diesel Engine

  • Lee, D.-H;Lee, D.-Y;Jo, M.-C;Cho, H.-N;Kim, Y.-S
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.367-375
    • /
    • 2004
  • We have developed a highly efficient boiler system using the 2,600cc Diesel engine. In this system, the co-generation concept is utilized in that the electric power is produced by the generator connected to the engine, and waste heat is recovered from both the exhaust gases and the engine itself by the shell-and-tube heat exchangers. The heat exchanger connected to the engine outlet is specially designed such that it not only recovers waste heat effectively from the exhaust gases, but significantly reduces an engine noise. It is found that the total efficiency(thermal efficiency plus electric power generation efficiency) of this system reaches maximum 96.3% which is about 15% higher than the typical Diesel engine boiler system currently being used worldwide.

The effect of Gas Mixture Ratio on Discharge Characteristics of an AC PDP Cell

  • Lee, Hae-June;Lee, D.K.;Choi, J.H.;Cho, Y.S.;Park, H.D.;Lee, H.J.;Park, C.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.171-174
    • /
    • 2005
  • Experimental measurements are reported and compared with the results of a two-dimensional fluid simulation for the investigation of the discharge characteristics regarding the change of the mixture ratio of Ne-Xe-He noble gases. The increase of Xe contents results in the increases of luminance and luminous efficiency while it also results in the increase of the breakdown voltage and the discharge time lag. The addition of He gas increases the brightness and the luminance efficiency. When Xe partial pressure is low, the luminance efficiency increases with the amount of He at the same total pressure. When Xe partial pressure is high, however, the luminance efficiency has a maximum value when the partial pressure of He is about 10% of the total pressure for a standard AC PDP cell with Xe fraction of $10{\sim}30%$.

  • PDF

주택 에너지효율향상을 위한 재정지원 방안에 관한 연구 (The Study of Financing for Energy Efficiency Homes)

  • 박기현
    • KIEAE Journal
    • /
    • 제12권6호
    • /
    • pp.63-68
    • /
    • 2012
  • The aim of this study is to evaluate current policies and suggest the way of overcome financial impediments to the energy efficiency function of residential buildings. Based on this analysis the paper enumerates policy recommendations for enhancing how energy efficiency is addressed in building codes and other policies for residential buildings. For achieving this goal, this study conducts the cost-benefit analysis to measure total energy savings and associated total cost. The results of study shows that the cost is greater than the benefit from 1st to 4th year but the benefit will be greater than the cost for the rest of the year. In addition, this study designs a financial support method and an implementation mechanism. Investment from the capital market will take place with the government's interest subsidy. Home retrofit will be undertaken with low interest rate with 2.5% and the return will be paid by a monthly energy bill. The results of this study provides some useful insights for the policy design, including the importance of developing information tools for providing appropriate information to households.

Effect of dielectric barrier discharge parameters on degradation efficiency of ethyl acetate

  • Deng, Xu;Lu, SiHeng;Zheng, Kun;Yu, ZhiMin
    • 도시과학
    • /
    • 제8권2호
    • /
    • pp.13-18
    • /
    • 2019
  • Using self-made coil dielectric barrier discharge reactor, the removal efficiency of ethyl acetate under simulated experimental parameters such as initial concentration of waste gas, total flow rate, relative humidity and voltage was investigated. The results show that the degradation rate of ethyl acetate increases with the increase of output voltage. When other conditions remain unchanged, the degradation rate decreases with the increase of initial concentration of ethyl acetate; with the increase of total flow rate, the degradation rate of ethyl acetate decreases; with the increase of relative humidity, the degradation rate first increases and then decreases, and when the relative humidity is 64%, the degradation efficiency is the highest.

폐비닐 재활용 여재를 이용한 소규모 오수종말처리장의 효율검증 (Efficiency Verification of Small-Scale Sewage Treatment Plant Using Discussed Vinyl as Biofilm Media)

  • 임재명;김병욱;구본수
    • 산업기술연구
    • /
    • 제18권
    • /
    • pp.1-6
    • /
    • 1998
  • This study was conducted to use disused vinyl as biofilm for biological sewage treatment. Efficiency verification was performed on laboratory and on-site plant. In laboratory study, total biochemical oxygen demand(TBOD) removal rate was ranged 94.8~97 % in each hydraulic retention tim(HRT), 12, 16, 20, 24 hr, respectively. At that time, filling rate was 50 %. And effluent TBOD concentration was low ranged 3.64~6.28 mg/L. In on-site plant, TBOD removal rate was ranged 88.2~96.8 % and effluent TBOD concentration was 4.8~17.7mg/L. This concentration was lower than disign effluent concentration, 30mg/L. Total kjeldhal nitrogen(TKN) removal efficiency was ranged 56.8~90.9%. This was resulted higher than Lab. scale treatment efficiency.

  • PDF

설치장소에 의한 스털링엔진 태양열 발전시스템의 성능예측 (Performance Prediction of a Solar Power System with Stirling Engine in Different Test Sites)

  • ;배명환;장형성;강상율
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2001년도 춘계학술대회 논문집
    • /
    • pp.122-128
    • /
    • 2001
  • The simulation analyses of a dish solar power system with stirling engine in this study are applied to system performance prediction if four different test sites; Seoul, Pusan and Cheju in Korea, and Naha in Japan. The effects of difference of concentrator type such as monolithic and stretched-membrane construction on system efficiency are also evaluated. The total amount of generated power for a year depends on the site. However the total maximum system efficiency in every site is approximately 16% and there isnt striking difference. It is also found that the maximum collector efficiency of stretched-membrane concentrator is about 3∼15% lower than that of the monolithic type.

  • PDF

농업용 보의 수차 발전기 효율 분석 (Efficiency Analysis for Water Turbine Generator of Agricultural Reservoir)

  • 김종겸
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1223-1227
    • /
    • 2013
  • If the factory test efficiency and field operation efficiency of water turbine are different from each other, issues for efficiency warranty can be raised. So, This paper shows the result for comparative analysis of field operating efficiency vs plant testing efficiency of the water turbine generator installed in agricultural reservoir. The efficiency of the induction generator is analyzed by the change of rotational speed with the parameter obtained by test, the efficiency of water turbine is calculated by the change of head with the design flow. Efficiency deviation of induction generator is lower but the variation of developed power is pretty high near the rated speed and the efficiency variation of water turbine is high by the fluctuation of head for constant flow. It was found that factory test efficiency and total efficiency of water turbine generator calculated according to the rotational speed are very close.

Feeding strategies with total mixed ration and concentrate may improve feed intake and carcass quality of Hanwoo steers

  • Lee, Soohyung;Lee, Sang Moo;Lee, Jaehun;Kim, Eun Joong
    • Journal of Animal Science and Technology
    • /
    • 제63권5호
    • /
    • pp.1086-1097
    • /
    • 2021
  • This study examined the impact of using total mixed ration (TMR) and concentrate on feed intake, daily gain, carcass yield grade, and carcass quality grade of Hanwoo steers and its subsequent economic efficiency. Thirty six 7-month-old Hanwoo steers were assigned to one of the four treatment groups, and each group was divided into three repeated pens, with each repeated pen comprising three steers. The treatment groups were: 1) separate feeding with commercial concentrate and forage (namely, SCF) for the entire experimental period; 2) TMR feeding for a growing period followed by SCF for the early and late fattening period (namely, TMRGSCF); 3) TMR feeding for growing and an early fattening period followed by SCF for the late fattening period (namely, TMREFSCF); and 4) TMR feeding for the entire experimental period (namely, TMRW). The results showed that the SCF treatment had significantly (p < 0.05) higher feed intake during the growing period than other treatments. In contrast, the total feed intake had little difference during early and late fattening as well as the whole period regardless of feeding strategies. Daily gain showed no difference during the growing period. However, it was significantly higher in SCF and TMREFSCF treatments for the early and late fattening period, respectively (p < 0.05). The daily gain during the total raising period is in the order of TMREFSCF > TMRGSCF > SCF > TMRW. Carcass characteristics, including carcass weight, loin eye muscle area, and carcass yield grade, did not significantly differ among different treatments. However, TMRW treatment, wherein TMR was fed for a long time, showed that the cold carcass weight was less compared with other treatments, but carcass yield grade was higher with thinner backfat. Backfat thickness was in the order of SCF > TMRGSCF > TMREFSCF > TMRW, showing that the thickness reduced with longer TMR feeding (p < 0.05). TMRGSCF, which numerically had a higher carcass quality grade, showed higher economic efficiency, whereas SCF showed low economic efficiency. In conclusion, it was more feasible to apply TMR strategy in the growing and early fattening period and then SCF for the early or late fattening period to improve carcass yield, quality grade, and economic efficiency.