• Title/Summary/Keyword: total curvature

Search Result 223, Processing Time 0.02 seconds

EFFECT OF SURFACE DEFECTS AND CROSS-SECTIONAL CONFIGURATION ON THE FATIGUE FRACTURE OF NITI ROTARY FILES UNDER CYCLIC LOADING (전동식 니켈 티타늄 파일의 표면 결함 및 단면 형태가 반복응력 하에서 피로 파절에 미치는 영향)

  • Shin, Yu-Mi;Kim, Eui-Sung;Kim, Kwang-Man;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.267-272
    • /
    • 2004
  • The purpose of this in vitro study was to evaluate the effect of surface defects and cross-sectional configuration of NiTi rotary files on the fatigue life under cyclic loading. Three NiTi rotary files ($K3^{TM},{\;}ProFile^{\circledR},{\;}and{\;}HERO{\;}642^{\circledR}$) with #30/.04 taper were evaluated. Each rotary file was divided into 2 subgroups : control (no surface defects) and experimental group (artificial surface defects), A total of six groups of each 10 were tested. The NiTi rotary files were rotated at 300rpm using the apparatus which simulated curved canal (40 degree of curvature) until they fracture. The number of cycles to fracture was calculated and the fractured surfaces were observed with a scanning electron microscope. The data were analyzed statistically. The results showed that experimental groups with surface defects had lower number of cycles to fracture than control group but there was only a statistical significance between control and experimental group in the $K3^{TM}$ (p<0.05), There was no strong correlation between the cross-sectional configuration area and fracture resistance under experimental conditions. Several of fractured files demonstrated characteristic patterns of brittle fracture consistent with the propagation of pre-existing cracks. This data indicate that surface defects of NiTi rotary files may significantly decrease fatigue life and it may be one possible factor for early fracture of NiTi rotary files in clinical practice.

Can proximal Gastrectomy Be Justified for Advanced Adenocarcinoma of the Esophagogastric Junction?

  • Sato, Yuya;Katai, Hitoshi;Ito, Maiko;Yura, Masahiro;Otsuki, Sho;Yamagata, Yukinori;Morita, Shinji
    • Journal of Gastric Cancer
    • /
    • v.18 no.4
    • /
    • pp.339-347
    • /
    • 2018
  • Purpose: To evaluate the status of number 3b lymph node (LN) station in patients with adenocarcinoma of the esophagogastric junction (AEG) and to investigate the optimal indications for radical proximal gastrectomy (PG) for AEG. Materials and Methods: Data of 51 patients with clinically advanced Siewert types II and III AEG who underwent total gastrectomy (TG) between April 2010 and July 2017 were reviewed. The proportion of metastatic LNs at each LN station was examined. Number 3 LN station was separately classified into number 3a and number 3b. The risk factors for number 3b LN metastasis and the clinicopathological features of number 3b-positive AEG patients were investigated. Results: The incidences of LN metastasis were the highest in number 1 (47.1%), followed by number 2 (23.5%), number 3a (39.2%), and number 7 (23.5%) LN stations. LN metastasis in number 3b LN station was detected in 4 patients (7.8%). A gastric invasion length of more than 40 mm was a significant risk factor for number 3b LN metastasis. All 4 patients with number 3b-positive AEG had advanced cancer with a gastric invasion length of more than 40 mm. The 5-year survival rate of patients with a gastric invasion length of more than 40 mm was 50.0%. Conclusions: Radical PG may be indicated for patients with AEG with gastric invasion length of less than 40 mm.

The Manufacture of Digital X-ray Devices and Implementation of Image Processing Algorithm (디지털 X-ray 장치 제작 및 영상 처리 알고리즘 구현)

  • Kim, So-young;Park, Seung-woo;Lee, Dong-hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.4
    • /
    • pp.195-201
    • /
    • 2020
  • This study studied scoliosis, one of the most common modern diseases caused by lifestyle patterns of office workers sitting in front of computers all day and modern people who use smart phones frequently. Scoliosis is a typical complication that takes more than 80% of the nation's total population at least once. X-ray are used to test for these complications. X-ray, a non-destructive testing method that allows scoliosis to be easily performed and filmed in various areas such as the chest, abdomen and bone without contrast agents or other instruments. We uses NI DAQ to miniaturize digital X-ray imaging devices and image intensifier in self-shielding housing with Vision Assistant for drawing lines to the top and the bottom of the spine to acquire angles, i.e. curvature in real-time. In this way, the research was conducted to see scoliosis patients and their condition easily and to help rapid treatment for solving the problem of posture correction in modern people.

Analysis of Radio Frequency (RF) Characteristics and Effectiveness according to the Number of Gores of Mesh Antenna (그물형 안테나의 고어 개수에 따른 Radio Frequency (RF) 특성 분석)

  • Kim, Jin-Hyuk;Lee, Si-A;Park, Tae-Yong;Choi, Han-Sol;Kim, Hongrae;Chae, Bong-Geon;Oh, Hyun-Ung
    • Journal of Space Technology and Applications
    • /
    • v.1 no.3
    • /
    • pp.364-374
    • /
    • 2021
  • This research discusses the change in radio frequency (RF) characteristics according to the number of Gores on the deployable mesh antennas for potential micro-satellite applications. The deployable type of lightweight mesh antenna can be used for various space missions such as communication/SAR/ SIGINT. In order to implement an ideal curvature of antenna surface, sufficient number of antenna rib structures are required. However, the increase in antenna ribs affects various design factors of the antenna system, especially total system mass, complexity of deployable mechanism and reliability. In this paper, the proper number of ribs for the mesh antenna were derived by comparison of electro-magnetic (EM) simulation results of example of antenna model in accordance with the various number of ribs.

Analysis and Validation of Geo-environmental Susceptibility for Landslide Occurrences Using Frequency Ratio and Evidential Belief Function - A Case for Landslides in Chuncheon in 2013 - (Frequency Ratio와 Evidential Belief Function을 활용한 산사태 유발에 대한 환경지리적 민감성 분석과 검증 - 2013년 춘천 산사태를 중심으로 -)

  • Lee, Won Young;Sung, Hyo Hyun;Ahn, Sejin;Park, Seon Ki
    • Journal of The Geomorphological Association of Korea
    • /
    • v.27 no.1
    • /
    • pp.61-89
    • /
    • 2020
  • The objective of this study is to characterize landslide susceptibility depending on various geo-environmental variables as well as to compare the Frequency Ratio (FR) and Evidential Belief Function (EBF) methods for landslide susceptibility analysis of rainfall-induced landslides. In 2013, a total of 259 landslides occurred in Chuncheon, Gangwon Province, South Korea, due to heavy rainfall events with a total cumulative rainfall of 296~721mm in 106~231 hours duration. Landslides data were mapped with better accuracy using the geographic information system (ArcGIS 10.6 version) based on the historic landslide records in Chuncheon from the National Disaster Management System (NDMS), the 2013 landslide investigation report, orthographic images, and aerial photographs. Then the landslides were randomly split into a testing dataset (70%; 181 landslides) and validation dataset (30%; 78 landslides). First, geo-environmental variables were analyzed by using FR and EBF functions for the full data. The most significant factors related to landslides were altitude (100~200m), slope (15~25°), concave plan curvature, high SPI, young timber age, loose timber density, small timber diameter, artificial forests, coniferous forests, soil depth (50~100cm), very well-drained area, sandy loam soil and so on. Second, the landslide susceptibility index was calculated by using selected geo-environmental variables. The model fit and prediction performance were evaluated using the Receiver Operating Characteristic (ROC) curve and the Area Under Curve (AUC) methods. The AUC values of both model fit and prediction performance were 80.5% and 76.3% for FR and 76.6% and 74.9% for EBF respectively. However, the landslide susceptibility index, with classes of 'very high' and 'high', was detected by 73.1% of landslides in the EBF model rather than the FR model (66.7%). Therefore, the EBF can be a promising method for spatial prediction of landslide occurrence, while the FR is still a powerful method for the landslide susceptibility mapping.

Cross-sectional Survey for Prevalence Rate of Scoliosis in Primary, Middle and High School Boys in Pusan City (부산시내 남자 초.중.고등학생의 척추측만증 유병률 측정을 위한 단면조사)

  • Kim, Bok-Yong;Park, Jung-Han;Kim, Poong-Taek
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.217-223
    • /
    • 1988
  • A cross-sectional survey was conducted to determine the prevalence rate of scoliosis in elementary, middle and high school boys in May 1988. The study population included 1,393 male students in Pusan ; 463 students of 4th grade in two elementary schools, 543 students of 1st grade in one middle school and 387 students of 1st grade in one high school. The students of elementary school were screened with inspection by two physicians at the same time and the students of middle and high schools were screened with both inspection by the same physicians and 70mm chest X-ray. Positive students in any one of the two screening tests were measured for height and body weight and asked for the shoulder side on which he carries the school bag. The angle of curvature on X-ray film was measured by Cobb's method. The number of positive students in any one of the two screening tests were 15(3.2%) in elementary schools, 174(32.0%) in middle school and 92(23.8%) in high school. However, positive rates in both tests were only 2.2% for the middle school students and 2.6% for the high school students and among these students 1.1% out of total middle school students and 2.3% of high school students had a curvature equal to or greater than $5^{\circ}$ of Cobb's angle on 70mm chest X-ray film. There was a statistically significant association between the direction of spinal curve and the shoulder side on which one carries school bag among positive students in both screening 1.sts (p<0.05) Mean height and body weight of 281 positive students in any one of two screening tests were compared with the Korean standard for the same age. Mean weight of elementary school students was nearly the same as the standard weight but the height was slightly shorter than the standard. However, both mean height and weight of the middle school students were lower than the standard while those of the high school students were higher. The prevalence rate of scoliosis for the 2nd and 3rd grades of high school is presumed to be higher than that of the 1st grade of high school and the rate for girls will be even higher than the rate for boys of the same age. Thus, scoliosis seems to be an important school health problem. To prevent scoliosis, it is recommeded to reduce the weight of school bag, educate the students to keep a right posture and exercise periodically.

  • PDF

EFFECT OF ROTATIONAL SPEED OF PROTAPERTM ROTARY FILE ON THE CHANCE OF ROOT CANAL CONFIGURATION (ProTaperTM로 근관성형시 회전 속도 변화가 근관형태에 미치는 영향)

  • Seo, Min-Chul;Jeon, Yoon-Jeong;Kang, In-Chol;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.179-185
    • /
    • 2006
  • This study was conducted to evaluate canal configuration after shaping by $ProTaper^{TM}$ with various rotational speed in J-shaped simulated resin canals. Forty simulated root canals were divided into 4 groups, and instrumented using by $ProTaper^{TM}$ at the rotational speed of 250, 300, 350 and 400 rpm. Pre-instrumented and post-instrumented images were taken by a scanner and those were superimposed. Outer canal width, inner canal width, total canal width, and amount of transportation from original axis were measured at 1, 2, 3, 4, 5, 6, 7 and 8 mm from apex. Instrumentation time, instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA followed by Scheffe's test. The results were as follows 1. Regardless of rotational speed, at the $1{\sim}2mm$ from the apex, axis of canal was transported to outer side of a curvature, and at 3~6 mm from the apex, to inner side of a curvature. Amounts of transportation from original axis were not sienifcantly different among experimental groups except at 5 and 6 mm from the apex. 2. Instrumentation time of 350 and 400 rpm was significantly less than that of 250 and 300 rpm (p<0.01). In conclusion the rotational speed of $ProTaper^{TM}$ files in the range of $250{\sim}400rpm$ does not affect the change of canal configuration, and high rotational speed reduces the instrumentation time. However appearance of separation and distortion of Ni-Ti rotary files can occur in high rotational speed.

Influence of Detailed Structure and Curvature of Woven Fabric on the Luminescence Effect of Wearable Optical Fiber Fabric (직물의 세부 구조 및 굴곡이 웨어러블 광섬유의 발광 효과에 미치는 영향)

  • Yang, Jin-Hee;Cho, Hyun-Seung;Kwak, Hwy-Kuen;Oh, Yun-Jung;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.55-62
    • /
    • 2018
  • The two main requirements of wearable optical fiber fabrics are that they must presuppose a high degree of flexibility and they must maintain the luminance effect in both flat and bent conformations. Therefore, woven optical fiber fabrics that satisfy the above conditions were developed by both weaving and by using computer embroidery. First, we measured the brightness of the wearable optical fiber fabric in the flat state at a total of 10 measurement points at intervals of 1 cm. Second, the wearable optical fiber fabric was placed horizontally on the forearm, where three-dimensional bending occurs, and the luminance values were recorded at the same 10 measurement points. For the woven fabric in the flat state, the maximum, minimum, average, and standard deviation luminance values were $5.23cd/m^2$, $2.74cd/m^2$, $3.56cd/m^2$, and $1.11cd/m^2$, respectively. The corresponding luminance values from the bent forearm were $7.92cd/m^2$ (maximum), $2.37cd/m^2$ (minimum), $4.42cd/m^2$ (average), and $2.16cd/m^2$ (standard deviation). In the case of the computer-embroidered fabric, the maximum, minimum, average, and standard deviation luminance values in the flat state were $7.56cd/m^2$, $3.84cd/m^2$, $5.13cd/m^2$, and $1.04cd/m^2$, respectively, and in the bent forearm state were $9.6cd/m^2$, $3.63cd/m^2$, $6.13cd/m^2$, and $2.26cd/m^2$, respectively. Therefore, the computer-embroidered fabric exhibited a higher luminous effect than the woven fabric because the detailed structure reduced light-loss due to the backside fabric. In both types of wearable optical fiber fabric the luminance at the forearm was 124% and 119%, respectively, and the light emitting effect of the optical fiber fabric was maintained even when bent by the human body. This is consistent with the principle of Huygens, which defines the wave theory of light, and also the Huygens-Fresnel-Kirchhoff principle, which states that the intensity of light increases according to the magnitude of the angle of propagation of the light wavefront (${\theta}$).

Clinical Effect of Bong Chuna Manual Therapy and Acupunture Treatment for Improving Cervical Curvature of Turtle Neck Syndrome and Measurement Method of Radiography (거북목증후군의 경추만곡 호전에 대한 봉추나요법과 침술의 효과와 방사선학적 평가방법 연구)

  • Oh, Won-Kyo;Lee, Eugune;Shin, Byung-Cheul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.19 no.1
    • /
    • pp.113-124
    • /
    • 2009
  • Objectives : The aim of this study was to observe the effect of Bong Chuna manual therapy(BCMT) and acupuncture on the Turtle Neck Syndrome(TNS) by the changes of radiological findings and symptoms. Methods : Total twenty-eight patients diagnosed as TNS were evaluated. Twenty patients in experimental group were treated by the combination of BCMT and acupuncture, eight patients in control group were treated by acupuncture only. We measured VAS(Visual analogue scale) as pain intensity and Neck Pain and Disability Scale(NDI) at pre- and post-treatment. Also the four line Cobb's method and Jochumsen method were assessed for evaluating the radiographical changes, additionally we used 'two line method'. Results : VAS score showed statistically significant reduction in pain intensity in both experimental group and control group after 8 weeks treatment, $-44.05{\pm}14.91$ vs $-23.75{\pm}14.08$ respectively. Also NDI score presented $-11.40{\pm}8.63$ reduction in experimental group, and it was significant statistically, however not in control group, $-8.63{\pm}9.84$ reduction after 8weeks treatment. In radiological findings, the four line Cobb's method, Jochumsen method and two line method were reduced after 8weeks treatment, $-9.30{\pm}10.33$, $-0.65{\pm}1.72$ and $-14.35{\pm}5.68$ in experimental group respectively, $-0.75{\pm}1.91$, $-0.25{\pm}0.71$ and $0.38{\pm}2.20$ in control group respectively. However they were statistical significance only in the four line Cobb's method and two line method in both group. Conclusions : Combination treatment of CMT and acupuncture showed better effect on pain reduction, VAS score and the correction of neck anteversion than acupuncture only in TNS. Two line method seems valuable for evaluating the improvement of radiographical changes in TNS.

A Comparison of Refractive Components in Anisometropia and Isometropia (굴절부등안과 동등안의 양안 굴절요소 차이 비교)

  • Shim, Hyun-Seog;Shim, Jun-Beom;Kim, Eun-Suck
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.187-193
    • /
    • 2011
  • Purpose: This study was to compare differences between both eyes in corneal powers, axial lengths, anterior chamber depths in anisometropia and isometropia, and to investigate the relationship between anisometropia and refractive components. Methods: The subject was a total of 83 patients, anisometropia 45 patients (90 eyes) and isometropia 38 patients (76 eyes) from 2.7 to 15.3 years old, prescribed eyeglasses and contact lenses by refraction from July 2010 to August 2010 in Gwangju City B eye clinic. Axial length, anterior chamber depth, corneal curvature, and corneal refractive power were measured using IOL Master. Refractive error was measured using an Auto-refractometer. Results: Anisometropia was a statistically significant difference in axial length, binocular refractive components, refractive error, and axial length, Axial length/corneal radius (AL/CR) ratio showed a statistically significant difference in anisometropia and isometropia. The major cause of anisometropia all 45 subjects was the axial length. Among the refractive components axial length, AL/CR had a strong correlation, but corneal refractive power had no correlation. Anterior chamber depth had a weak correlation. Conclusions: This study found that refractive error was the most axial ametropia caused by the axial length. The main cause of anisometropia was the axial length, but refractive components had a weak correlation.