• Title/Summary/Keyword: total correction

Search Result 751, Processing Time 0.035 seconds

Normal Control Study of Cerebral Blood Flow by Tc-99m HM-PAO SPECT ($^{99m}TC-HMPAO$ SPECT를 이용한 정상인 국소뇌혈류의 정량적 분석)

  • Moon, Dae-Hyuk;Lee, Bum-Woo;Lee, Kyung-Han;Choi, Yoon-Ho;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Yoon, Byung-Woo;Lee, Nam-Soo;Roh, Jae-Kyu;Myung, Ho-Jin;Koong, Sung-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.155-163
    • /
    • 1989
  • Regional cerebral perfusion was evaluated in 15 normal controls by single photon emission computed tomography using $^{99m}Tc$ HM-PAO. For quantitative analysis, 13 pairs of homologous region of interest (ROI) were drawn on three transverse slices matching the vascular territories and cerebral cortices, and normal values of 3 semiqunatitative indices including 'Right to left ratio'(R/L ratio), 'Regional index'(RI), and 'Region to cerebellum ratio'(R/cbll ratio) were calculated. Mean values of R/L ratios of homotogous regions were ranged from 0.985 to 1.023, and mean ${\pm}2$ s.d. of all regions did not exceed 11% of mean. Significant difference of RIs (mean count per voxel of a ROI/mean count per voxel of total ROIs) between regions were found (p<0.001) with highest values in occipital cortex and cerebellum. After attenuation correction, RIs in deep gray, cranial portion of anterior cerebral artery and vascular territories in the 2nd slice increased significantly (p < 0.05-0.001), but vise versa in other ROIs. Region to cerebellum ratios also showed regional difference similar to RIs.

  • PDF

A Hydrological Study on the Flow Characteristic of the Keum River (하천의 유황에 관한 수문학적 연구)

  • 박성우
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.2
    • /
    • pp.3438-3453
    • /
    • 1974
  • Unmeasured value of water for human lives is widely approved, but the water as one of natural resources cannot be evaluated with ease since it changes itself ceaselessly by flowing-out or transforming the phase. Major objectives of the study concerned consequently with investigating its potentiality and evaluating its time seriesly availabity in a volumatic unit. And the study was performed to give the accurate original data to the planners concerned. Some developed rational methods of predicting runoff related to hydrological factors as precipitation, were to be discusseed for their theorical background and to be introduced whether they needed some corrections or not, comparing their estimation with actual runoff from synthetic unit-hydrograph methods. To do so, the study was performed to select Kongju Station, located at the watershed of the Keum River, and to collect such hydrological data from 1962 to 1972 as runoff, water level, precipitation, and so on. On the other hand, the hydrological characteristics of runoff were concluded more reasonably in numerical values, with calculating the the ratio of daily runoff to annual discharge of the flow in percentage, as. the distribution ratio of runoff. The results of the study can be summarized as follows; (1) There needed some consideration to apply the Kajiyama's Formula for predicting monthly runoff of rivers in Korea.(2) The rational methods of predicting runoff might be recommended to become less theorical and reliable than the unique analyzation of data concerned in each given water basin. The results from the Keum River prepared above would be available to any programms concerned. (3) The most accurate estimation for runoff could be suggested to synthetic unithydrograph methods calculated from the relation between each storm and runoff. However it was not contained in the study. (4) The relations between rainfall and runoff at KongJu Station were as following table. The table showed some intersting implications about the characteristics of runoff at site, which indicated that the runoff during three months from July to September approached total of 60% of quantity while precipitation concentrated on the other three from June to August. And there were some months which had more amount of runoff than expected values calculated from the precipitation, such as Febrary, March, August, September, Octover, and December, shown in the table. Such implications should be suggested to meet any correction factors in the future formulation concerned with the subjects, if any rational methods would be required.

  • PDF

Line-of-Sight (LOS) Vector Adjustment Model for Restitution of SPOT 4 Imagery (SPOT 4 영상의 기하보정을 위한 시선 벡터 조정 모델)

  • Jung, Hyung-Sup
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.2
    • /
    • pp.247-254
    • /
    • 2010
  • In this paper, a new approach has been studied correcting the geometric distortion of SPOT 4 imagery. Two new equations were induced by the relationship between satellite and the Earth in the space. line-of-sight (LOS) vector adjustment model for SPOT 4 imagery was implemented in this study. This model is to adjust LOS vector under the assumption that the orbital information of satellite provided by receiving station is uncertain and this uncertainty makes a constant error over the image. This model is verified using SPOT 4 satellite image with high look angle and thirty five ground points, which include 10 GCPs(Ground Control Points) and 25 check points, measured by the GPS. In total thirty five points, the geometry of satellite image calculated by given satellite information(such as satellite position, velocity, attitude and look angles, etc) from SPOT 4 satellite image was distorted with a constant error. Through out the study, it was confirmed that the LOS vector adjustment model was able to be applied to SPOT4 satellite image. Using this model, RMSEs (Root Mean Square Errors) of twenty five check points taken by increasing the number of GCPs from two to ten were less than one pixel. As a result, LOS vector adjustment model could efficiently correct the geometry of SPOT4 images with only two GCPs. This method also is expected to get good results for the different satellite images that are similar to the geometry of SPOT images.

Prediction of the Chemical Composition and Fermentation Parameters of Fresh Coarse Italian Ryegrass Haylage using Near Infrared Spectroscopy

  • Kim, Ji Hye;Park, Hyung Soo;Choi, Ki Choon;Lee, Sang Hoon;Lee, Ki-Won
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.37 no.4
    • /
    • pp.350-357
    • /
    • 2017
  • Near infrared spectroscopy (NIRS) is a rapid and accurate method for analyzing the quality of cereals, and dried animal forage. However, one limitation of this method is its inability to measure fermentation parameters in dried and ground samples because they are volatile, and therefore, respectively lost during the drying process. In order to overcome this limitation, in this study, fresh coarse haylage was used to test the potential of NIRS to accurately determine chemical composition and fermentation parameters. Fresh coarse Italian ryegrass haylage samples were scanned at 1 nm intervals over a wavelength range of 680 to 2500 nm, and optical data were recorded as log 1/reflectance. Spectral data, together with first- and second-order derivatives, were analyzed using partial least squares (PLS) multivariate regressions; scatter correction procedures (standard normal variate and detrend) were used in order to reduce the effect of extraneous noise. Optimum calibrations were selected based on their low standard error of cross validation (SECV) values. Further, ratio of performance deviation, obtained by dividing the standard deviation of reference values by SECV values, was used to evaluate the reliability of predictive models. Our results showed that the NIRS method can predict chemical constituents accurately (correlation coefficient of cross validation, $R_{cv}^2$, ranged from 0.76 to 0.97); the exception to this result was crude ash ($R_{cv}^2=0.49$ and RPD = 2.09). Comparison of mathematical treatments for raw spectra showed that second-order derivatives yielded better predictions than first-order derivatives. The best mathematical treatment for DM, ADF, and NDF, respectively was 2, 16, 16, whereas the best mathematical treatment for CP and crude ash, respectively was 2, 8, 8. The calibration models for fermentation parameters had low predictive accuracy for acetic, propionic, and butyric acids (RPD < 2.5). However, pH, and lactic and total acids were predicted with considerable accuracy ($R_{cv}^2$ 0.73 to 0.78; RPD values exceeded 2.5), and the best mathematical treatment for them was 1, 8, 8. Our findings show that, when fresh haylage is used, NIRS-based calibrations are reliable for the prediction of haylage characteristics, and therefore useful for the assessment of the forage quality.

Application Analysis of GIS Based Distributed Model Using Radar Rainfall (레이더강우를 이용한 GIS기반의 분포형모형 적용성 분석)

  • Park, Jin-Hyeog;Kang, Boo-Sik;Lee, Geun-Sang
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.1
    • /
    • pp.23-32
    • /
    • 2008
  • According to recent frequent local flash flood due to climate change, the very short-term rainfall forecast using remotely sensed rainfall like radar is necessary to establish. This research is to evaluate the feasibility of GIS-based distributed model coupled with radar rainfall, which can express temporal and spatial distribution, for multipurpose dam operation during flood season. $Vflo^{TM}$ model was used as physically based distributed hydrologic model. The study area was Yongdam dam basin ($930\;km^2$) and the 3 storm events of local convective rainfall in August 2005, and the typhoon.Ewiniar.and.Bilis.collected from Jindo radar was adopted for runoff simulation. Distributed rainfall consistent with hydrologic model grid resolution was generated by using K-RainVieux, pre-processor program for radar rainfall. The local bias correction for original radar rainfall shows reasonable results of which the percent error from the gauge observation is less than 2% and the bias value is $0.886{\sim}0.908$. The parameters for the $Vflo^{TM}$ were estimated from basic GIS data such as DEM, land cover and soil map. As a result of the 3 events of multiple peak hydrographs, the bias of total accumulated runoff and peak flow is less than 20%, which can provide a reasonable base for building operational real-time short-term rainfall-runoff forecast system.

  • PDF

Head motion during cone-beam computed tomography: Analysis of frequency and influence on image quality

  • Moratin, Julius;Berger, Moritz;Ruckschloss, Thomas;Metzger, Karl;Berger, Hannah;Gottsauner, Maximilian;Engel, Michael;Hoffmann, Jurgen;Freudlsperger, Christian;Ristow, Oliver
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.227-236
    • /
    • 2020
  • Purpose: Image artifacts caused by patient motion cause problems in cone-beam computed tomography (CBCT) because they lead to distortion of the 3-dimensional reconstruction. This prospective study was performed to quantify patient movement during CBCT acquisition and its influence on image quality. Materials and Methods: In total, 412 patients receiving CBCT imaging were equipped with a wireless head sensor system that detected inertial, gyroscopic, and magnetometric movements with 6 dimensions of freedom. The type and amplitude of movements during CBCT acquisition were evaluated and image quality was rated in 7 different anatomical regions of interest. For continuous variables, significance was calculated using the Student t-test. A linear regression model was applied to identify associations of the type and extent of motion with image quality scores. Kappa statistics were used to assess intra- and inter-rater agreement. Chi-square testing was used to analyze the impact of age and sex on head movement. Results: All CBCT images were acquired in a 10-month period. In 24% of the investigations, movement was recorded (acceleration: >0.10 [m/s2]; angular velocity: >0.018 [°/s]). In all examined regions of interest, head motion during CBCT acquisition resulted in significant impairment of image quality (P<0.001). Movement in the horizontal and vertical axes was most relevant for image quality (R2>0.7). Conclusion: Relevant head motions during CBCT imaging were frequently detected, leading to image quality loss and potentially impairing diagnosis and therapy planning. The presented data illustrate the need for digital correction algorithms and hardware to minimize motion artefacts in CBCT imaging.

Software development for the visualization of brain fiber tract by using 24-bit color coding in diffusion tensor image

  • Oh, Jung-Su;Song, In-Chan;Ik hwan Cho;Kim, Jong-Hyo;Chang, Kee-Hyun;Park, Kwang-Suk
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.133-133
    • /
    • 2002
  • Purpose: The purpose of paper is to implement software to visualize brain fiber tract using a 24-bit color coding scheme and to test its feasibility. Materials and Methods: MR imaging was performed on GE 1.5 T Signa scanner. For diffusion tensor image, we used a single shot spin-echo EPI sequence with 7 non-colinear pulsed-field gradient directions: (x, y, z):(1,1,0),(-1,1,0),(1,0,1),(-1,0,1),(0,1,1),(0,1,-1) and without diffusion gradient. B-factor was 500 sec/$\textrm{mm}^2$. Acquisition parameters are as follows: TUTE=10000ms/99ms, FOV=240mm, matrix=128${\times}$128, slice thickness/gap=6mm/0mm, total slice number=30. Subjects consisted of 10 normal young volunteers (age:21∼26 yrs, 5 men, 5 women). All DTI images were smoothed with Gaussian kernel with the FWHM of 2 pixels. Color coding schemes for visualization of directional information was as follows. HSV(Hue, Saturation, Value) color system is appropriate for assigning RGB(Red, Green, and Blue) value for every different directions because of its volumetric directional expression. Each of HSV are assigned due to (r,$\theta$,${\Phi}$) in spherical coordinate. HSV calculated by this way can be transformed into RGB color system by general HSV to RGB conversion formula. Symmetry schemes: It is natural to code the antipodal direction to be same color(antipodal symmetry). So even with no symmetry scheme, the antipodal symmetry must be included. With no symmetry scheme, we can assign every different colors for every different orientation.(H =${\Phi}$, S=2$\theta$/$\pi$, V=λw, where λw is anisotropy). But that may assign very discontinuous color even between adjacent yokels. On the other hand, Full symmetry or absolute value scheme includes symmetry for 180$^{\circ}$ rotation about xy-plane of color coordinate (rotational symmetry) and for both hemisphere (mirror symmetry). In absolute value scheme, each of RGB value can be expressed as follows. R=λw|Vx|, G=λw|Vy|, B=λw|Vz|, where (Vx, Vy, Vz) is eigenvector corresponding to the largest eigenvalue of diffusion tensor. With applying full symmetry or absolute value scheme, we can get more continuous color coding at the expense of coding same color for symmetric direction. For better visualization of fiber tract directions, Gamma and brightness correction had done. All of these implementations were done on the IDL 5.4 platform.

  • PDF

Effects of Various Intracranial Volume Measurements on Hippocampal Volumetry and Modulated Voxel-based Morphometry (두개강의 용적측정법이 해마의 용적측정술과 화소기반 형태계측술에 미치는 영향)

  • Tae, Woo-Suk;Kim, Sam-Soo;Lee, Kang-Uk;Nam, Eui-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.63-73
    • /
    • 2009
  • Purpose : To investigate the effects of various intracranial volume (ICV) measurement methods on the sensitivity of hippocampal volumetry and modulated voxel-based morphometry (mVBM) in female patients with major depressive disorder (MDD). Materials and Methods : T1 magnetic resonance imaging (MRI) data for 41 female subjects (21 MDD patients, 20 normal subjects) were analyzed. Hippocampal volumes were measured manually, and ICV was measured manually and automatically using the FreeSurfer package. Gray and white matter volumes were measured separately. Results : Manual ICV normalization provided the greatest sensitivity in hippocampal volumetry and mVBM, followed by FreeSurfer ICV, GWMV, and GMV. Manual and FreeSurfer ICVs were similar in normal subjects (p = 0.696), but distinct in MDD patients (p = 0.000002). Manual ICV-corrected total gray matter volume (p = 0.0015) and Manual ICV-corrected bilateral hippocampal volumes (right, p = 0.014; left, p = 0.004) were decreased significantly in MDD patients, but the differences of hippocampal volumes corrected by FreeSurfer ICV, GWMV, or GMV were not significant between two groups (p > 0.05). Only manual ICV-corrected mVBM analysis was significant after correction for multiple comparisons. Conclusion : The method of ICV measurement greatly affects the sensitivity of hippocampal volumetry and mVBM. Manual ICV normalization showed the ability to detect differences between women with and without MDD for both methods.

  • PDF

MYLK Polymorphism Associated with Blood Eosinophil Level among Asthmatic Patients in a Korean Population

  • Lee, Soo Ok;Cheong, Hyun Sub;Park, Byung Lae;Bae, Joon Seol;Sim, Won Chul;Chun, Ji-Yong;Isbat, Mohammad;Uh, Soo-Taek;Kim, Yong Hooun;Jang, An-Soo;Park, Choon-Sik;Shin, Hyoung Doo
    • Molecules and Cells
    • /
    • v.27 no.2
    • /
    • pp.175-181
    • /
    • 2009
  • The myosin light chain kinase (MYLK) gene encodes both smooth muscle and nonmuscle cell isoforms. Recently, polymorphisms in MYLK have been reported to be associated with several diseases. To examine the genetic effects of polymorphisms on the risk of asthma and related phenotypes, we scrutinized MYLK by re-sequencing/genotyping and statistical analysis in Korean population (n = 1,015). Seventeen common polymorphisms located in or near exons, having pairwise $r^2$ values less than 0.25, were genotyped. Our statistical analysis did not replicate the associations with the risk of asthma and log-transformed total IgE levels observed among African descendant populations. However, two SNPs in intron 16 (+89872C> G and +92263T> C), which were in tight LD (|D'| = 0.99), revealed significant association with log-transformed blood eosinophil level even after correction multiple testing ($P=0.002/P^{corr}=0.01$ and $P=0.002/P^{corr}=0.01$, respectively). The log-transformed blood eosinophil levels were higher in individuals bearing the minor alleles for +89872C> G and +92263T> C than in those bearing other allele. In additional subgroup analysis, the genetic effects of both SNPs were much more apparent among asthmatic patients and atopic asthma patients. Among atopic asthma patients, the log-transformed blood eosinophil levels were proportionally increased by gene-dose dependent manner of in both +89872C> G and +92263T> C(P = 0.0002 and P = 0.00007, respectively). These findings suggest that MYLK polymorphisms might be among the genetic factors underlying differential increases of blood eosinophil levels among asthmatic patients. Further biological and/or functional studies are needed to confirm our results.

Short-term Mechanical Circulatory Support with a Centrifugal Pump - Results of Peripheral Extracorporeal Membrane Oxygenator According to Clinical Situation

  • Lee, Woo-Surng;Chee, Hyun-Keun;Song, Meong-Gun;Kim, Yo-Han;Shin, Je-Kyoun;Kim, Jun-Seok;Lee, Song-Am;Hwang, Jae-Joon
    • Journal of Chest Surgery
    • /
    • v.44 no.1
    • /
    • pp.9-17
    • /
    • 2011
  • Background: A peripheral extracorporeal membrane oxygenator (p-ECMO) has been developed to support patients who are dying due to a serious cardiopulmonary condition. This analysis was planned to define the clinical situation in which the patient benefits most from a p-ECMO. Material and Methods: Between June 2007 and Aug 2009, a total of 41 adult patients used the p-ECMO. There were 23 males and 18 females (mean age $54.4{\pm}15.1$ years). All patients had very unstable vital signs with hypoxia and complex cardiac problems. We divided the patients into 4 groups. In the first group, a p-ECMO was used as a bridge to cardiac operation. In the second group, patients did not have the opportunity to undergo any cardiac procedures; nevertheless, they were treated with a p-ECMO. In the third group, patients mostly had difficulty in weaning from CPB (cardiopulmonary bypass) after cardiac operation. The fourth group suffered from many complications, such as pneumonia, bleeding, infections, and LV dysfunction with underlying cardiac problems. All cannulations were performed by the Seldinger technique or cutting down the femoral vessel. A long venous cannula of $DLP^{(R)}$ (Medtronic Inc, Minneapolis, MN) or $RMI^{(R)}$ (Edwards Lifesciences LLC, Irvine, CA) was used together with a 17~21 Fr arterial cannula and a 21 Fr venous cannula. As a bypass pump, a Capiox emergency bypass system ($EBS^{(R)}$; Terumo, Tokyo, Japan) was used. We attempted to maintain a flow rate of $2.4{\sim}3.0\;L/min/m^2$ and an activated clotting time (ACT) of around 180 seconds. Results: Nine patients survived by the use of the p-ECMO. Ten patients were weaned from a p-ECMO but they did not survive, and the remainder had no chance to be weaned from the p-ECMO. The best clinical situation to apply the p-ECMO was to use it as a bridge to cardiac operation and for weaning from CPB after cardiac operation. Conclusion: Various clinical results were derived by p-ECMO according to the clinical situation. For the best results, early adoption of the p-ECMO for anatomical correction appears important.