• Title/Summary/Keyword: total correction

Search Result 751, Processing Time 0.03 seconds

A Simulation Model for Estimating Evapotranspiration of Soybean Crop (콩 생육시기별 증발산량의 추정모형 설정)

  • Son, Eung-Ryong;Eom, Ki-Cheol;Ryu, Kwan-Sig;Kim, Ki-Joon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.33 no.3
    • /
    • pp.254-261
    • /
    • 1988
  • Lysimeter and field experiments were conducted in Sandy Loam to establish a simple estimation model for evapotranspiration (ET) of soybean for three years (l984-1986). Potential ET (PET) could be estimated by the eq.1 using Pan-evaporation (Eo) and was ranged from 1.1 to 4.6 mm/day during the experiments. PET (mm/day)=1.348+0.573 Eo …(1) Crop coefficient (Kc=maximum ET/PET) could be estimated by the eq.2 using Growth degree (G=days after planting/total growing days) and was ranged from 0.2 to 1.1 and from 0.6 to 1.4 for monoculture cropping and double cropping followed by barley, respectively, during the experiments. Monoculture : Kc=0.016+3.719 G-3.224 G$^2$…(2), Double cropping : Kc=0.609+2.014 G-2.120 G$^2$…(2). However, the maximum Kc was shown when G was about 50% and 40% for the monoculture and the double cropping, respectively. Soil water coefficient (f=AET/maximum ET) could be estimated by the eq.3 using soil water tension (Ψ) in 15cm depth. and it was decleased to 0.2 when Ψ was 10 bar. f=0.755-0.537 log │Ψ│…(3) Consequentially, the model to estimate the Actual ET (AET) of soybean was determined as eq.4 with the correction coefficient of -0.380. AET(mm/day)=PETㆍKcㆍf -0.380 …(4) The estimated AET were compared with the measured AET to verify the model established above. The average deviation of the estimated ET(AET) was 0.5782$\pm$0.338 (mm/day), and it would be within reasonable confidence range.

  • PDF

A comparative study to measure the sagittal condylar inclination using mechanical articulator, virtual articulator and jaw tracking device

  • Liya Ma;Fei Liu;Jiansong Mei;Jiarui Chao;Zhenyu Wang;Jiefei Shen
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.1
    • /
    • pp.11-21
    • /
    • 2023
  • PURPOSE. To compare the sagittal condylar inclination (SCI) in dentate individuals measured by the different methods with mechanical articulator (MA), virtual articulator (VA), and a jaw tracking device (JTD) system. MATERIALS AND METHODS. A total of 22 healthy dentate participants were enrolled in this study. For MA workflow, the SCI was obtained by a semi-adjustable articulator with protrusive interocclusal records. The SCI was also set on a VA by aligning intraoral scan (IOS) with cone beam computed tomography (CBCT) and facial scan (FS), respectively. These virtual workflows were conducted in a dental design software, namely VAIOS-CBCT and VAIOS-FS. Meanwhile, a JTD system was also utilized to perform the measurement. Intraclass correlation was used to assess the repeatability within workflows. The bilateral SCI values were compared by Wilcoxon matched-pairs signed rank test for each workflow, and Kruskal-Wallis test and post hoc p-value Bonferroni correction were used to compare the differences among four workflows. The agreement of VAIOS-CBCT, VAIOS-FS, and JTD compared with MA was evaluated by Bland-Altman analysis. RESULTS. Intraclass correlation of the SCI revealed a high degree of repeatability for each workflow. There were no significant differences between the left and right sides (P > .05), except for VAIOS-CBCT (P = .028). Significant differences were not found between MA and VAIOS-FS (P > .05). Bland-Altman plots indicated VAIOS-CBCT, VAIOS-FS, and JTD were considered to substitute MA with high 95% limits of agreement. CONCLUSION. The workflow of VAIOS-FS provided an alternative approach to measure the SCI compared with MA.

Physical and mechanical changes on titanium base of three different types of hybrid abutment after cyclic loading

  • Rimantas Oziunas;Jurgina Sakalauskiene;Laurynas Staisiunas;Gediminas Zekonis;Juozas Zilinskas;Gintaras Januzis
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.1
    • /
    • pp.33-43
    • /
    • 2023
  • PURPOSE. This study investigated the physical and mechanical changes in the titanium base of three different hybrid abutment materials after cyclic loading by estimating the post-load reverse torque value (RTV), compressive side fulcrum wear pattern of titanium base, and surface roughness. MATERIALS AND METHODS. A total of 24 dental implants were divided into three groups (n = 8 each): Group Z, LD, and P used zirconia, lithium disilicate, and polyetheretherketone, respectively, for hybrid abutment fabrication. RTV was evaluated after cyclic loading with 50 N for 1.2 × 106 chewing cycles. The compressive sides of the titanium bases were analyzed using a scanning electron microscope, and the roughness of the affected areas was measured using an optical profilometer after loading. Datasets were analyzed using Kruskal-Wallis test followed by Mann-Whitney tests with the Bonferroni correction (α = .05). RESULTS. Twenty-three samples passed the test; one LD sample fractured after 770,474 cycles. Post-load RTV varied significantly depending on the hybridabutment material (P = .020). Group P had a significantly higher median of post-load RTVs than group Z (16.5 and 14.3 Ncm, respectively). Groups LD and P showed minor signs of wear, and group Z showed a more pronounced wear pattern. While evaluating compressive side affected area roughness of titanium bases, lower medians were shown in group LD (Ra 0.16 and Rq 0.22 ㎛) and group P (Ra 0.16 and Rq 0.23 ㎛) than in group Z (Ra 0.26 and Rq 0.34 ㎛); significant differences were found only among the unaffected surface and group Z. CONCLUSION. The hybrid abutment material influences the post-load RTV. Group Z had a more pronounced wear pattern on the compressive side of titanium base; however, the surface roughness was not statistically different among the hybridabutment groups.

Network design for correction of deterioration due to hologram compression (홀로그램 압축으로 인한 열화 보정을 위한 네트워크 설계)

  • Song, Joon Boum;jang, Junhyuck;Hwang, Yunseok;Cho, Inje
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2020.11a
    • /
    • pp.377-379
    • /
    • 2020
  • The hologram data is having a dependence on the pixel pitch of the SLM (spatial light modulator) and the wavelength of light, and the quality of the digital hologram is proportional to the unit pixel pitch and the total resolution. In addition, since each pixel has a complex value, the amount of data in the digital hologram also increases exponentially, and the size is bound to be very large. Therefore, in order to efficiently handle digital hologram files, it is essential to reduce the file size through a codec and store it. Recently, research on enhancing image quality damaged by the codec is actively underway. In this paper, the hologram image of JPEG Pleno, which is the standard hologram data, was used, and the image quality damage that occurs whenthe holographic image is encoded and decoded through the JPEG2000, AVC, and HEVC codec is enhanced with a deep learning network to find out whether the image quality can be improved. we also compare and quantitatively find out the degree of improvement in image quality.

  • PDF

Mechanical and thermal stability investigation of functionally graded plates resting on visco-Pasternak foundation

  • Samira Hassiba Tagrara;Mohamed Mehdi hamri;Mahmoud Mohamed Selim Saleh;Mofareh Hassan Ghazwani;Abdelbaki Chikh;Abdelmoumen Anis Bousahla;Abdelhakim Kaci;Fouad Bourada;Abdelouahed Tounsi
    • Steel and Composite Structures
    • /
    • v.46 no.6
    • /
    • pp.839-856
    • /
    • 2023
  • This work presents a simple four-unknown refined integral plate theory for mechanical and thermal buckling behaviors of functionally graded (FG) plates resting on Visco-Pasternak foundations. The proposed refined high order shear deformation theory has a new displacement field which includes indeterminate integral variables and contains only four unknowns in which any shear correction factor not used, with even less than the conventional theory of first shear strain (FSDT). Governing equations are deduced from the principle of minimum total potential energy and a Navier type analytical solution is adopted for simply supported FG plates. The Visco-Pasternak foundations is considered by adding the impact of damping to the usual foundation model which characterized by the linear Winkler's modulus and Pasternak's foundation modulus. The accuracy of the present model is demonstrated by comparing the computed results with those available in the literature. Some numerical results are presented to show the impact of material index, elastic foundation type, and damping coefficient of the foundation, on the mechanical and thermal buckling behaviors of FG plates.

Prediction of Fire Curves Considering the Relationship between Mass Increase and Combustion Time of Combustibles (연소물의 질량증가와 연소시간의 상관관계를 고려한 화재곡선 예측)

  • Eun-Joon Nam;Tae-Il Lee;Goang-Seup Zi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.2
    • /
    • pp.9-16
    • /
    • 2024
  • In this paper, we aimed to convert the fire curve in volume units to a fire curve per unit area for application in the Fire Dynamic Simulator (FDS) surface heat release rate method. The fire curve was expressed dimensionlessly considering the total combustion characteristic time, and improvements were made to represent the appropriate ratios for the growth , steady, and decay phases concerning the fire intensity. Additionally, a correction function for combustion characteristic time varying with mass increase was derived. Also to control the growth time values according to the increase in mass, a function to correct the growth phase ratio was derived. Consequently, utilizing existing data, a formula was established to determine the reference mass for combustion materials and predict the fire curve based on mass increase.

Renormalization of Thalamic Sub-Regional Functional Connectivity Contributes to Improvement of Cognitive Function after Liver Transplantation in Cirrhotic Patients with Overt Hepatic Encephalopathy

  • Yue Cheng;Jing-Li Li;Jia-Min Zhou;Gao-Yan Zhang;Wen Shen;Xiao-Dong Zhang
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.2052-2061
    • /
    • 2021
  • Objective: The role of preoperative overt hepatic encephalopathy (OHE) in the neurophysiological mechanism of cognitive improvement after liver transplantation (LT) remains elusive. This study aimed to explore changes in sub-regional thalamic functional connectivity (FC) after LT and their relationship with neuropsychological improvement using resting-state functional MRI (rs-fMRI) data in cirrhotic patients with and without a history of OHE. Materials and Methods: A total of 51 cirrhotic patients, divided into the OHE group (n = 21) and no-OHE group (n = 30), and 30 healthy controls were enrolled in this prospective study. Each patient underwent rs-fMRI before and 1 month after LT. Using 16 bilateral thalamic subregions as seeds, we conducted a seed-to-voxel FC analysis to compare the thalamic FC alterations before and after LT between the OHE and no-OHE groups, as well as differences in FC between the two groups of cirrhotic patients and the control group. Correction for multiple comparisons was conducted using the false discovery rate (p < 0.05). Results: We found abnormally increased FC between the thalamic sub-region and prefrontal cortex, as well as an abnormally decreased FC between the bilateral thalamus in both OHE and no-OHE cirrhotic patients before LT, which returned to normal levels after LT. Compared with the no-OHE group, the OHE group exhibited more extensive abnormalities prior to LT, and the increased FC between the right thalamic subregions and right inferior parietal lobe was markedly reduced to normal levels after LT. Conclusion: The renormalization of FC in the cortico-thalamic loop might be a neuro-substrate for the recovery of cognitive function after LT in cirrhotic patients. In addition, hyperconnectivity between thalamic subregions and the inferior parietal lobe might be an important feature of OHE. Changes in FC in the thalamus might be used as potential biomarkers for recovery of cognitive function after LT in cirrhotic patients.

Pulmonary Artery Angioplasty for Improving Ipsilateral Lung Perfusion in Adolescent and Adult Patients: An Analysis Based on Cardiac Magnetic Resonance Imaging and Lung Perfusion Scanning

  • Dong Hyeon Son;Jooncheol Min;Jae Gun Kwak;Sungkyu Cho;Woong-Han Kim
    • Journal of Chest Surgery
    • /
    • v.57 no.4
    • /
    • pp.360-368
    • /
    • 2024
  • Background: The left pulmonary artery (LPA) may be kinked and stenotic, especially in tetralogy of Fallot, because of ductal tissue and anterior deviation of the conal septum. If LPA stenosis is not effectively treated during total correction, surgical angioplasty is occasionally performed. However, whether pulmonary artery (PA) angioplasty in adolescents or adults improves perfusion in the ipsilateral lung remains unclear. Methods: This retrospective review enrolled patients who underwent PA angioplasty for LPA stenosis between 2004 and 2019. Among patients who underwent a lung perfusion scan (LPS) or cardiac magnetic resonance imaging (cMRI) pre- and post-pulmonary angioplasty, those aged >13 years with <40% left lung perfusion (p-left) in the pre-angioplasty study were included. Preoperative and postoperative computed tomography, LPS, and cMRI data were collected. The perfusion ratio was analyzed according to the LPA's anatomical characteristics. Results: Seventeen adolescents and 16 adults (≥18 years old) were finally included (median age, 17 years). The most common primary diagnosis was tetralogy of Fallot (87.9%). In all patients, LPA angioplasty was performed concomitantly with right ventricular outflow tract reconstruction. No patients died. Preoperative p-left was not significantly different between adolescents and adults; however, adolescents had significantly higher postoperative p-left than adults. P-left significantly increased in adolescents, but not in adults. Seven patients had significant stenosis (z-score <-2.0) confined only to the proximal LPA and demonstrated significantly increased p-left. Conclusion: PA angioplasty significantly increased ipsilateral lung perfusion in adolescents. If focal stenosis is confined to the proximal LPA, PA angioplasty may improve ipsilateral lung perfusion, regardless of age.

Value of Tibiotalocalcaneal Arthrodesis Using Retrograde Intramedullary Nailing in Severe Hindfoot Deformity and Arthritis (심한 후족부 변형 및 경거종골간 관절염에서 골수강내 금속정을 이용한 경거종골 관절 유합술의 가치)

  • Park, Jae-Gu;Chung, Hyung-Jin;Bae, Su-Young;Lee, Jung-Hwan;Kim, Hwi-Young;Lee, Jun Seok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.133-140
    • /
    • 2019
  • Purpose: This study examined the radiological and clinical outcomes of tibiotalocacalcaneal arthrodesis using retrograde intramedullary nailing in a severe hindfoot deformity and ankle/subtalar arthritis. Materials and Methods: A total of 22 patients (22 cases) with a severe hindfoot deformity and arthritis underwent tibiotalocalcaneal arthrodesis with retrograde intramedullary nails. The average age was 57.4 years (22-82 years) and the mean follow-up was 29.6 months (12-74 months). The radiological outcomes included an assessment of the preoperative and postoperative coronal ankle alignment, hindfoot alignment, sagittal alignment, and postoperative union time. The clinical outcomes were evaluated using the visual analogue scale (VAS), American Orthopaedic Foot and Ankle Society (AOFAS) score, and postoperative complications. The results were analyzed statistically by dividing the patients into two groups based on a 10° angle of deformity. Results: Regarding the preoperative coronal ankle alignment, 14 patients had a mean varus deformity of 17.8°±14.5° and six had a mean valgus deformity of 8.1°±6.6°. Postoperatively, a satisfactory postoperative coronal ankle alignment of less than 5° was obtained in all patients. Regarding the preoperative hindfoot alignment, 12 patients showed a mean varus deformity of 15.2°±10.5° and six had a mean valgus deformity of 8.1°±4.2°. In total, 94.4% (17 patients) had satisfactory postoperative hindfoot alignment of less than 5°. Radiological union was achieved in 90.9% at an average of 19.2 weeks (12-32 weeks) and there were 2 cases of nonunion. The clinical outcomes showed improvement in the mean VAS and AOFAS scores (p<0.001, p<0.001, respectively). Even a preoperative severe deformity more than 10° showed a significant deformity correction of coronal ankle alignment and hindfoot alignment, postoperatively (p<0.001, p<0.001, respectively). No significant differences were found between the patients with a preoperative coronal ankle deformity more than 10° and those less than 10° regarding the mean postoperative coronal ankle alignment (p=0.162). Conclusion: Tibiotalocalcaneal arthrodesis using retrograde intramedullary nailing is an acceptable technique for achieving satisfactory deformity correction, high union rate with minimal complications, and improvement of the clinical outcomes. In addition, tibiotalocalcaneal arthrodesis using retrograde intramedullary nailing is considered an effective treatment option, particularly in severe ankle and hindfoot deformities.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.