• Title/Summary/Keyword: total correction

Search Result 756, Processing Time 0.029 seconds

Comparison of Correlation between CVS-75 Mode and Korea Mode to Estimate Emission Factors from Vehicles (자동차 오염물질 배출계수 산정을 위한 CVS-75모드와 국내차속모드의 상관성 비교 연구)

  • Jung, Sung-Woon;Ryu, Jeong-Ho;Lyu, Young-Sook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.383-391
    • /
    • 2006
  • In Korea, the major source of serious air pollution is motor vehicles. Air pollution from vehicles has been annually increased. Then the government will try to control the vehicle emission by applying the effective emission management policy for the manufactured and in-used car. It is necessary to correctly calculate the emission factor for successful propulsion of the vehicle emission control policy. In this study, correlation analysis of exhaust emissions from vehicles between CVS-75 mode and Korea mode was conducted. A total of 25 light-duty buses were tested on the chassis dynamometer system in order to measure CO, HC, NOx PM and fuel efficiency (F.E.). For the test modes, 10 different Korea modes and CVS-75 mode were used. As the result of correlation analysis between those modes, most of the correlation coefficients were higher than 0.90. On the basis of high correlation between those modes, correction factors by driving conditions were estimated. Through the results of this study, we obtained essential basic data to correct difference from those modes.

A Hybrid Approach to Information System Sizing and Selection using Simulation and Genetic Algorithm (시뮬레이션과 유전 알고리즘의 하이브리드 기법을 이용한 정보시스템 용량 산정 및 선택 방안)

  • Min, Jae-H.;Chang, Sung-Woo;Shin, Kyung-Shik
    • Korean Management Science Review
    • /
    • v.24 no.2
    • /
    • pp.143-155
    • /
    • 2007
  • The purpose of this paper is to develop a new method for information system sizing and selection based on a hybrid mixture of simulation and genetic algorithm, and to show its cost-effectiveness by applying it to a real world problem. To serve this purpose, we propose an operational model which identifies a set of system alternatives using simulation, and determines the optimal one using genetic algorithm. Specifically, with simulation, we generate probability distributions describing real data gathered from actual system, which can overcome the major weakness of the existing methodology that normally employs point estimates of the actual data and constant correction factors without theoretical rationale. We next search for the optimal combination of H/W, the number of CPUs, and S/W, which meets both of our business goals of incurring low TCO(total cost of ownership) and maintaining a good level of transaction processing performance. Experimental result shows the proposed method in this paper saves the cost while it preserves the system's capacity within allowable performance range.

Development and Evaluation of an e-learning Blood-borne Infection Control Program for Nursing Students (간호학생을 위한 e-learning 혈행성 감염예방 프로그램의 개발과 효과)

  • Choi, Jeong-Sil;Eom, Mi-Ran
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.17 no.2
    • /
    • pp.249-258
    • /
    • 2010
  • Purpose: To develop an e-learning blood-borne infection control program and to evaluate the effects of the program on risk perception, knowledge, preventive health behaviors related to blood-borne infections, and satisfaction with the program by nursing student. Methods: The program was developed through the processes of analysis, design, development, implementation, and evaluation. The pre-experimental research design involved a one group pretest-posttest design. The setting was two universities located in Daejeon, Korea. Results: Using the program that was designed and developed, results for the total score of risk perception, knowledge, and preventive health behaviors in the post-test application were significantly higher than in the pre-test application (p<.05). Relevance and usefulness of the information received the highest ratings, while the system's design were demonstrated to have the lowest ratings. Those areas requiring correction were modified accordingly. Conclusions: Application of an e-learning blood-borne infection control program is effective, and can be expanded to other student nurses who also have a high risk of blood-borne infections.

Destripe Hyperspectral Images with Spectral-spatial Adaptive Unidirectional Variation and Sparse Representation

  • Zhou, Dabiao;Wang, Dejiang;Huo, Lijun;Jia, Ping
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.752-761
    • /
    • 2016
  • Hyperspectral images are often contaminated with stripe noise, which severely degrades the imaging quality and the precision of the subsequent processing. In this paper, a variational model is proposed by employing spectral-spatial adaptive unidirectional variation and a sparse representation. Unlike traditional methods, we exploit the spectral correction and remove stripes in different bands and different regions adaptively, instead of selecting parameters band by band. The regularization strength adapts to the spectrally varying stripe intensities and the spatially varying texture information. Spectral correlation is exploited via dictionary learning in the sparse representation framework to prevent spectral distortion. Moreover, the minimization problem, which contains two unsmooth and inseparable $l_1$-norm terms, is optimized by the split Bregman approach. Experimental results, on datasets from several imaging systems, demonstrate that the proposed method can remove stripe noise effectively and adaptively, as well as preserve original detail information.

DENSITY STRUCTURE AND STABILITY OF THE SUBCOMPONENTS IN GIANT MOLECULAR CLOUD COMPLEXES

  • Yoo, Chin-Woo;Hong, Seung-Soo
    • Journal of The Korean Astronomical Society
    • /
    • v.19 no.1
    • /
    • pp.33-49
    • /
    • 1986
  • Radial distribution of internal density has been determined for thirteen subclouds in the three giant molecular cloud complexes accompanying Mon OB1, Mon OB2 and CMa OB1 associations, We modeled their radial density structures with the density distribution of isothermal gas spheres. Most of the subclouds, nine out of the thirteen, are well described by isothermal spheres of single component; while the rest four require an additional component. Total mass and potential energy of each subcloud are also derived from the radial density structure; thermal energy and internal velocity dispersion required for sustaining the density structure are deduced from the isothermal gas model. Our derived masses of the clouds are comparable to the values determined by Blitz (1978) under LTE assumption. This agreement suggests that the correction factor for non-LTE effect on mass-estimate is not far from unity. The ratio of the gravitational potential energy to the kinetic energy of thermal motion is as large as 250; hence the thermal motion alone cannot support these clouds against the gravity. Being supported by turbulence motion with velocities of six to seven times the thermal velocity, the clouds of one-component type seem to be in equilibrium with the gravity; while the clouds of two-component type are likely to be in the stage of gravitational collapse.

  • PDF

High Efficiency AC-DC Converter Using Average-Current Mode Flyback Topology for PDP and Improvement of Hold-up Characteristic (평균전류모드 플라이백 토폴로지를 이용한 PDP용 고효율 AC-DC 컨버터 및 Hold-up 특성 개선)

  • Lee, Kyung-In;Lim, Seung-Beom;Jung, Yong-Min;Oh, Eun-Tae;Lee, Jun-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.2
    • /
    • pp.23-27
    • /
    • 2008
  • Recently, regulation for THD (Total Harmonic Distortion) such as IEC 61000-3-2, IEEE 519 is being reinforced about a product which directly connects to AC line in order to prevent distortion of common power source in electronic equipment and electrical machinery. In order to satisfy these regulations, conventional circuits were used two-stage structure attached power factor correction circuit at ahead of converter but this method complicate the circuit and then a number of element increases thereupon the cost of production rises. in this paper, we propose a high efficiency single-stage 300W PFC fly-back converter that improved power factor and efficiency than conventional two-stage power module.

  • PDF

A New Control Scheme of the Line-Interactive UPS Using the Series Active Compensator (직렬 능동 보상기를 이용한 Line-Interactive UPS의 새로운 제어 기법)

  • Jang, Hoon;Lee, Woo-Cheol;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.8
    • /
    • pp.405-412
    • /
    • 2003
  • This paper presents a three-phase Line-Interactive uninterruptible power supply (UPS) system with series-parallel active power-line conditioning capabilities, using synchronous reference frame (SRF) based controller, which allows an effective power factor correction, source harmonic voltage compensation, load harmonic current suppression, and output voltage regulation. The three-phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low THD (total harmonic distortion). The control algorithm using SRF method and the active power flow through the Line-interactive UPS systems are described and studied. The simulation and experimental results are depicted in this paper to show the effect of the proposed algorithm.

Distortion Elimination for Buck PFC Converter with Power Factor Improvement

  • Xu, Jiangtao;Zhu, Meng;Yao, Suying
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.10-17
    • /
    • 2015
  • A quasi-constant on-time controlled buck front end in combined discontinuous conduction mode and boundary conduction mode is proposed to improve power factor (PF).When instantaneous AC input voltage is lower than the output bus voltage per period, the buck converter turns into buck-boost converter with the addition of a level comparator to compare input voltage and output voltage. The gate drive voltage is provided by an additional oscillator during distortion time to eliminate the cross-over distortion of the input current. This high PF comes from the avoidance of the input current distortion, thereby enabling energy to be delivered constantly. This paper presents a series analysis of controlling techniques and efficiency, PF, and total harmonic distortion. A comparison in terms of efficiency and PF between the proposed converter and a previous work is performed. The specifications of the converter include the following: input AC voltage is from 90V to 264V, output DC voltage is 80V, and output power is 94W.This converter can achieve PF of 98.74% and efficiency of 97.21% in 220V AC input voltage process.

Implementation of an Export System for GIS Arrester Facilities (GIS 피뢰설비 전문가 시스템 구현)

  • Kim, Il-Kwon;Song, Jae-Yong;Moon, Seung-Bo;Cha, Myung-Soo;Rhyu, Keel-Soo;Kil, Gyung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1465-1466
    • /
    • 2006
  • The monitoring and diagnosing technique for lightning arresters is important to assure the reliability of power supply in GIS-substation. In this paper, we described the implementation of an expert system for GIS arrester facilities. The proposed system consists of a data acquisition module (DAM), a wireless communication module, and a personal computer. The DAM detects system voltages, total leakage currents and its harmonic components, and includes an algorithm to calculate the resistive leakage current by the principle that the magnitudes of resistive leakage current are equal at the same level of the system voltage applied to the arrestor. Also, we designed a surge event detection circuit which can acquire the date, the polarity, and the amplitude of surge events. All the acquired data are transmitted after correction by many algorithms to the remote station through the ZigBee protocol. The expert system is based on the Jave Expert System Shell (JESS) and make more reliable decision by using an exclusive inference process.

  • PDF

Optimum Inner and Outer Code Rates for Concatenated Codes in Gaussian Binary Symmetric Channels (가우시안 이진 대칭 채널에서 쇄상부호의 최적 내.외 부호율에 관한 연구)

  • Lee, Ye Hoon
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.110-113
    • /
    • 2014
  • In this paper, we address a problem of finding the optimum inner and outer code rates for a concatenated code in Gaussian binary symmetric channels. Clearly, as the inner code rate decreases, the error detection capability of the inner code increases. However, decreasing the inner code rate implies a decrease in error-correction capability of the outer code when overall code rate is fixed. With this notion in mind, we examine the optimum distribution of redundancy on the outer and inner codes to achieve a maximum performance gain in the concatenated coding scheme. Our analysis shows that the maximum coding gain can be obtained when the inner code rate is maximized and the outer code rate is minimized under the constraint of total code rate is fixed.