• Title/Summary/Keyword: total correction

Search Result 756, Processing Time 0.047 seconds

A study on surgical significance of angiographic pulmonary arterial size in tetralogy (활로 4 징증에서 술전 폐동맥 크기에 대한 연구)

  • Jo, Jae-Il;Kim, Jong-Hwan
    • Journal of Chest Surgery
    • /
    • v.16 no.1
    • /
    • pp.40-48
    • /
    • 1983
  • Tetralogy of Fallot is characterized by the interventricular septal defect associated with obstruction of the right ventricular outflow. The importance of the latter anatomic malformation was clinically evaluated according to the angiographic measurements of the pulmonary arteries along with the pulmonary valve annulus. Seventy of a total 76 patients operated on during a whole year of 1981 were the patients for clinical evaluation. Fifteen patients died within 1 month after operation with the operative mortality of 21.4%. The young age and the severity of pulmonary arterial hypoplasia were ones among the surgical risk factors at a total corrective surgery of tetralogy. Preoperative angiographic measurements of the pulmonary arteries to speculate the expected postoperative ratio between the left ventricular and the right ventricular pressures were retrospectively calculated according to the formula. The predicted values of P RV/LV greater than 0.5 carried apparenliy higher complication and mortality rates than the group of P RV/LV less then 0.5. The selection of the candidates for either a total correction or the staged operation In tetralogy of Fallot can be evaluated on the preoperative angiographic measurements and the expected Improvements of the clinical results were discussed.

  • PDF

Surgical correction of Total Anomalous Pulmonary Venous Connection - Review of 37 Cases treated surgically during 10 years (총폐정맥환류이상증에 대한 외과적 요법 및 장기 성적)

  • 나명훈
    • Journal of Chest Surgery
    • /
    • v.20 no.4
    • /
    • pp.695-705
    • /
    • 1987
  • This report provides follow - up data on 37 patients, aged 7 days to 25 years [median: 6.5 months], who underwent repair of total anomalous pulmonary venous connection at Seoul national University Hospital between May, 1978 and June, 1987. The patients were 22 males and 17 females and the sex ratio was 1.6 to 1, showing a male predominance. Sixteen patients had supracardiac, 13 cardiac, 3 infracardiac and 5 had a mixed type. The duration of follow up was from 1 month to 60 months [median: 14 months] There were eight early and one late deaths, and the overall mortality was 24%. The deaths during 1 year of life were eight [89%] and only one death [11%] occurred above 1 year of age. The mortality of cardiac type was unusually high, accounting for 56 percent of the total death, which was probably due to the preoperative poor clinical condition such as pulmonary edema and congestive heart failure. The major cause of death was the perioperative myocardial failure, and the survival was closely related to the preoperative clinical status, age and moderately elevated pulmonary arterial pressure, the sign of the elevated pulmonary vascular resistance and pulmonary venous obstruction. Early diagnosis and early application of surgical intervention is essential to the improved postoperative survival

  • PDF

Development of Korean VTEC Polynomial Model Using GIM

  • Park, Jae-Young;Kim, Yeong-Guk;Park, Kwan-Dong
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.4
    • /
    • pp.297-304
    • /
    • 2022
  • The models used for ionosphere error correction in positioning using Global Navigation Satellite System (GNSS) are representatively Klobuchar model and NeQuick model. Although these models can correct the ionosphere error in real time, the disadvantage is that the accuracy is only 50-60%. In this study, a method for polynomial modeling of Global Ionosphere Map (GIM) which provides Vertical Total Electron Content (VTEC) in grid type was studied. In consideration of Ionosphere Pierce Points (IPP) of satellites with a receivable elevation angle of 15 degrees or higher on the Korean Peninsula, the target area for model generation and provision was selected, and the VTEC at 88 GIM grid points was modeled as a polynomial. The developed VTEC polynomial model shows a data reduction rate of 72.7% compared to GIM regardless of the number of visible satellites, and a data reduction rate of more than 90% compared to the Slant Total Electron Content (STEC) polynomial model when there are more than 10 visible satellites. This VTEC polynomial model has a maximum absolute error of 2.4 Total Electron Content Unit (TECU) and a maximum relative error of 9.9% with the actual GIM. Therefore, it is expected that the amount of data can be drastically reduced by providing the predicted GIM or real-time grid type VTEC model as the parameters of the polynomial model.

Conservative orthodontic treatment for severe pathologic migration following total glossectomy: A case report

  • Giap, Hai-Van;Jeon, Ji Yoon;Kim, Kee Deog;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.52 no.4
    • /
    • pp.298-307
    • /
    • 2022
  • Glossectomy combined with radiotherapy causes different levels of tongue function disorders and leads to severe malocclusion, with poor periodontal status in cancer survivors. Although affected patients require regular access to orthodontic care, special considerations are crucial for treatment planning. This case report describes the satisfactory orthodontic management for the correction of severe dental crowding in a 43-year-old female 6 years after treatment for tongue cancer with total glossectomy combined with radiotherapy, to envision the possibility of orthodontic care for oral cancer survivors. Extraction was performed to correct dental crowding and establish proper occlusion following alignment, after considering the possibility of osteoradionecrosis. Orthodontic mini-implants were used to provide skeletal anchorage required for closure of the extraction space and intrusion of the anterior teeth. The dental crowding was corrected, and Class I occlusal relationship was established after 36 months of treatment. The treatment outcome was sustained after 15 months of retention, and long-term follow-up was recommended.

The Clinical Study on Far Diatance Spectacles for Teen-age and Twenty-age (10대와 20대의 원용안경에 관한 임상적 연구)

  • Hong, Soo-Hak;Kim, Sang-Kun;Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.149-154
    • /
    • 2002
  • This study is examined the difference between binocular spherical diopter and astigmatism diopter, spherical diopter, astigmatism diopter, and axis of astigmatism by sex and age with reference to the prescription of refraction for a total of 257 persons, 134 persons (male:78, female: 56)of teen-age and 123 persons of twenty-age who visit optical shop. Spherical correction diopter is mainly distributed to 280 eyes between -0.25D and -4.00D. And in astigmatism correction, for right astigmatism, 48 eyes(49.48%) are prescribed astigmatism diopter for a range of C-0.25~C-0.50D, 29 eyes(29.89%) has C-0.75~C-1.00D, 65 eyes(67.01%) has with the rule astigmatism. For left astigmatism, 43 eyes(42.57%) are prescribed astigmatism diopter of C-0.25~C-0.50D and 37 eyes(36.63%) has C-0.75C~1.00D, 73 eyes(72.27%) are shown with the rule astigmatism. And also each 108 persons(47.16%) and 28 persons(25.00%) are shown no difference between binocular spherical correction diopter and binocular astigmatism correction diopter, 94 eyes(39.49%) of teen-age and 104 eyes(42.27%) of twenty-age, male 119 eyes(41.90%) and female 79 eyes(34.34%) need correcting astigmatism. In pupillary distance, 165 persons mostly have 59~64mm.

  • PDF

Comparison of OC and EC Measurement Results Determined by Thermal-optical Analysis Protocols (열광학적 분석 프로토콜에 의한 유기탄소와 원소탄소 측정값 비교)

  • Kim, Hyosun;Jung, Jinsang;Lee, Jinhong;Lee, Sangil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.5
    • /
    • pp.449-460
    • /
    • 2015
  • Carbonaceous aerosol is generally classified into OC (organic carbon) and EC (elemental carbon) by thermal optical analysis. Both NIOSH (National institute of occupational safety and health) with high temperature (HighT) and IMPROVE-A (Interagency monitoring of protected visual environments) with low temperature (LowT) protocols are widely used. In this study, both protocols were applied for ambient $PM_{2.5}$ samples (Daejeon, Korea) in order to underpin differences in OC and EC measurements. An excellent agreement between NIOSH and IMPROVE-A protocol was observed for TC (total carbon). However, significant differences between OC and EC appeared and the differences were larger for EC than OC. The main differences between two protocols are temperature profile and charring correction method. For the same charring correction method, HighT_OC was 10% higher than LowT_ OC, while HighT_EC was 15% and 33% lower than LowT_EC for TOT (thermal-optical transmittance) and TOR (thermal-optical reflectance), respectively. This difference may be caused by the temperature of OC4 in He step and possibly difference in POC (pryorilized OC) formation. For the same temperature profile, OC by TOT was about 26% higher than that by TOR. In contrast, EC by TOT was about 50% lower than that by TOR. POC was also dependent on both temperature profile and the charring correction method, showing much distinctive differences for the charring correction method (i.e., POC by TOT to POC by TOR ratio is about 2). This difference might be caused by different characteristics between transmittance and reflectance for monitoring POC formation within filters. Results from this study showed that OC and EC depends on applied analysis protocol as shown other studies. Because of the nature of the thermal optical analysis, it may not be possible to have an absolute standard analysis protocol that is applicable for any ambient $PM_{2.5}$. Nevertheless, in order to provide consistent measurement results for scientists and policy makers, future studies should focus on developing a harmonized standard analysis protocol that is suitable for a specific air domain and minimizes variations in OC and EC measurement results. In addition, future elaborate studies are required to find and understand the causes of the differences.

Recovery of Lithospheric Magnetic Component in the Satellite Magnetometer Observations of East Asia (인공위성 자력계에서 관측된 동아시아 암권의 지자기이상)

  • Kim, Jeong-Woo
    • Geophysics and Geophysical Exploration
    • /
    • v.5 no.3
    • /
    • pp.157-168
    • /
    • 2002
  • Improved procedures were implemented in the production of the lithospheric magnetic anomaly map from Magsat satellite magnetometer data of East Asia between $90^{\circ}E-150^{\circ}E$ and $10^{\circ}S-50^{\circ}N$. Procedures included more effective selection of the do·it and dawn tracks, ring current correction, and separation of core field and external field effects. External field reductions included an ionospheric correction and pass-by-pass correlation analysis. Track-line noise effects were reduced by spectral reconstruction of the dusk and dawn data sets. The total field magnetic anomalies were differentially-reduced-to-the-pole to minimize distortion s between satellite magnetic anomalies and their geological sources caused by corefield variations over the study area. Aeromagnetic anomalies were correlated with Magsat magnetic anomalies at the satellite altitude to test the lithospheric veracity of anomalies in these two data sets. The aeromagnetic anomalies were low-pass filtered to eliminate high frequency components that may not be shown at the satellite altitude. Although the two maps have a low CC of 0.243, there are many features that are directly correlated (peak-to-peak and trough-to-trough). The low CC between the two maps was generated by the combination of directly- and inversely-correlative anomaly features between them. It is very difficult to discriminate directly, inversely, and nully correlative features in these two anomaly maps because features are complicatedly correlated due to the depth and superposition of the anomaly sources. In general, the lithospheric magnetic components were recovered successfully from satellite magnetometer observations and correlated well with aeromagnetic anomalies in the study area.

OPTIMAL TRAJECTORY CORRECTION MANEUVER DESIGN USING THE B-PLANE TARGETING METHOD FOR FUTURE KOREAN MARS MISSIONS (B-평면 조준법을 이용한 화성 탐사선의 궤적 보정을 위한 최적의 기동 설계)

  • Song, Young-Joo;Park, Eun-Seo;Yoo, Sung-Moon;Park, Sang-Young;Choi, Kyu-Hong;Yoon, Jae-Cheol;Yim, Jo-Ryeong;Choi, Joon-Min;Kim, Byung-Kyo
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.4
    • /
    • pp.451-462
    • /
    • 2005
  • Optimal Trajectory Correction Maneuver (TCM) design algorithm has been developed using the B-plane targeting method for future Korean Mars missions. For every-mission phase, trajectory informations can also be obtained using this developed algorithms which are essential to design optimal TCM strategy. The information were computed under minimum requiring perturbations to design Mars missions. Spacecraft can not be reached at designed aim point because of unexpected trajectory errors, caused by many perturbations and errors due to operating impulsive maneuvers during the cruising phase of missions. To maintain spacecraft's appropriate trajectory and deliver it to the designed aim point, B-plane targeting techniques are needed. A software NPSOL is used to solve this optimization problem, with the performance index of minimizing total amount of TCM's magnitude. And also executing time of maneuvers on be controlled for the user defined maneuver number $(1\~5)$ of TCMs. The constraints, the Mars arrival B-plane boundary conditions, are formulated for the problem. Results of this work show the ability to design and analyze overall Mars missions, from the Earth launch phase to Mars arrival phase including capture orbit status for future Korean Mars missions

Quality Analysis of GCP Chip Using Google Map (Google Map을 이용한 GCP 칩의 품질 분석)

  • Park, Hyeongjun;Son, Jong-Hwan;Shin, Jung-Il;Kweon, Ki-Eok;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_1
    • /
    • pp.907-917
    • /
    • 2019
  • Recently, the demand for high-resolution satellite images increases in many fields such as land monitoring and terrain analysis. Therefore, the need for geometric correction is increasing. As an automatic precision geometric correction method, there is a method of automatically extracting the GCP by matching between the GCP Chip and the satellite image. For automatic precision geometric correction, the success rate of matching GCP Chip and satellite image is important. Therefore, it is important to evaluate the matching performance of the manufactured GCP Chip. In order to evaluate the matching performance of GCP Chips, a total of 3,812 GCP Chips in South Korea were used as experimental data. The GCP Chip matching results of KOMPSAT-3A and Google Map showed similar matching results. Therefore, we determined that Google Map satellite imagery could replace high-resolution satellite imagery. Also, presented a method using center point and error radius of Google Map to reduce the time required to verify matching performance. As a result, it is best to set the optimum error radius to 8.5m. Evaluated the matching performance of GCP Chips in South Korea using Google Maps. And verified matching result using presented method. As a result, the GCP Chip s in South Korea had a matching success rate of about 94%. Also, the main matching failure factors were analyzed by matching failure GCP Chips. As a result, Except for GCP Chips that need to be remanufactured, the remaining GCP Chips can be used for the automatic geometric correction of satellite images.

A Statistical Correction of Point Time Series Data of the NCAM-LAMP Medium-range Prediction System Using Support Vector Machine (서포트 벡터 머신을 이용한 NCAM-LAMP 고해상도 중기예측시스템 지점 시계열 자료의 통계적 보정)

  • Kwon, Su-Young;Lee, Seung-Jae;Kim, Man-Il
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.23 no.4
    • /
    • pp.415-423
    • /
    • 2021
  • Recently, an R-based point time series data validation system has been established for the statistical post processing and improvement of the National Center for AgroMeteorology-Land Atmosphere Modeling Package (NCAM-LAMP) medium-range prediction data. The time series verification system was used to compare the NCAM-LAMP with the AWS observations and GDAPS medium-range prediction model data operated by Korea Meteorological Administration. For this comparison, the model latitude and longitude data closest to the observation station were extracted and a total of nine points were selected. For each point, the characteristics of the model prediction error were obtained by comparing the daily average of the previous prediction data of air temperature, wind speed, and hourly precipitation, and then we tried to improve the next prediction data using Support Vector Machine( SVM) method. For three months from August to October 2017, the SVM method was used to calibrate the predicted time series data for each run. It was found that The SVM-based correction was promising and encouraging for wind speed and precipitation variables than for temperature variable. The correction effect was small in August but considerably increased in September and October. These results indicate that the SVM method can contribute to mitigate the gradual degradation of medium-range predictability as the model boundary data flows into the model interior.