• 제목/요약/키워드: torsional force

검색결과 199건 처리시간 0.028초

Rudder Horn 최적화 설계 방안 (Optimizing Design for Rudder Horn)

  • 박성근
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2006년도 특별논문집
    • /
    • pp.77-80
    • /
    • 2006
  • In recent booming up of the ship building market, the supplying of large scale casting is difficult to keep the delivery schedule for ship yard because of the restrict manufacturer in Korea. And also, it is main cause to rise-up the cost of castings. This paper describes the outline of guidance of optimizing design for Rudder Horn Casting to reduce the risk of the delivery problem to ship yard.

  • PDF

Computer Graphics / Molecular Mechanics Studies of Quinolones Geometry Comparison with X-ray Crystal Structures

  • Chung, Sung-Kee;Daniel, F. chodosh
    • Bulletin of the Korean Chemical Society
    • /
    • 제11권4호
    • /
    • pp.313-317
    • /
    • 1990
  • Geometries for several representative quinolone carboxylate type antibacterials have been calculated by computer graphics/molecular mechanics energy minimization procedures using both MM2 and AMBER force fields. The calculated geometries were found to be in reasonable agreements with the corresponding X-ray crystal structures. It has been pointed out that notwithstanding the weaknesses associated with calculating the resonance and hydrogen bonding contributions, the employed methods are capable of generating credible ring geometries and torsional angle dispositions of N(1)-ethyl and 3-carboxylate substituents of the quinolones.

An independent distortional analysis method of thin-walled multicell box girders

  • Park, Nam-Hoi;Kang, Young-Jong;Kim, Hee-Joong
    • Structural Engineering and Mechanics
    • /
    • 제21권3호
    • /
    • pp.275-293
    • /
    • 2005
  • When a thin-walled multicell box girder is subjected to an eccentric load, the distortion becomes an important global response in addition to flexure and torsion. The three global responses appear in a combined form when a conventional shell element is used thus it is not an easy task to examine the three global responses separately. This study is to propose an analysis method using conventional shell element in which the three global responses can be separately decomposed. The force decomposition method which was designed for a single-cell box girder by Nakai and Yoo is expanded herein to multicell box girders. The eccentric load is decomposed in the expanded method into flexural, torsional, and multimode distortional forces by using the force equilibrium. From the force decomposition, the combined global responses of multicell box girders can be resolved into separate responses and the distortional response which is of primary concern herein can be obtained separately. It is shown from a series of extensive comparative studies using three box girder bridge models that the expanded method produces accurate decomposed results. Noting that the separate consideration of individual global response is of paramount importance for optimized multicell box girder design, it can be said that the proposed expanded method is extremely useful for practicing engineers.

헬리컬기어-플레이트 시스템의 방사소음 (Radiated Noise of Helical Gear-plate System)

  • 박찬일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1042-1048
    • /
    • 2007
  • This work analytically investigated the radiated noise of a helical gear-housing system due to the excitation of helical gears. The helical gears were modeled as a 12-degree of freedom mass-spring-damper system; the shaft was modeled as a rod, a beam, and a torsional shaft; and the gear housing was modeled as a clamped circular plate with viscous damping. The modeling of this system used transfer matrices for helical gears, shafts, and bearings. Damping for both the bearings and the plate were obtained by modal testing. For the evaluation of noise, sound pressure from the plate due to the force and the moment in both radial and tangential directions was analytically derived by the Rayleigh integral. The analytical derivation and parameters from the experiment were applied to an analysis of noise for the two sets of helical gears with differing gear ratios. The analysis showed that the moment excitation in both helical gears contributed more to the noise of the plate than axial force excitation.

  • PDF

도로용 발전장치 개발을 위한 에너지 발생기구 해석 (A Numerical Study of Energy Mechanism for Development of Road Generator System)

  • 이석영
    • 한국정밀공학회지
    • /
    • 제31권10호
    • /
    • pp.935-945
    • /
    • 2014
  • This paper presents a new road generative system that employs a pad of preventive overspeed or tollgate. The system consists of pad, shaft, torsional damper, oneway-clutch, gear system, and electricity generator components. When the car driven through the road generation system, it occurred to surplus energy in the DC power. In order to maximize the power of electricity energy harvester, the simulation software is developed. It is used to determine parametric dimension for optimal design with the theoretically calculated results from the simulation software. The transient responses at the conditions of low and high vehicle speed are compared with the calculated results as torque, impact force, power, out energy etc. Consequently, before design a road generation system, the analysis of simulation results shows that the proposed concept and system has efficiency and confidence.

미세 작동기의 설계 및 위치 제어에 관한 연구 (A Study of Position Control and Design for Microelectrostatic Mechanical Actuator)

  • 최원석;지태영;김건년;박효덕;허훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.911-916
    • /
    • 2003
  • Microactuator is frequently used in some optical or electrical applications such as light modulators and spatial scanner devices. When microactuator is implemented, it should be operated at accurate positions proportional to input voltage. Therefore in order to obtain rapid responses and reduced errors, a position control technique is used. In the paper, design procedure for the mems actuator and a typical PID controller is adapted to improve performance of microactuator as well. Also electrostatic force for the torsional microactuator is calculated via well-known Hornbeck's method.

  • PDF

마그네틱 기어드 모터의 자석 기어 자기력 해석 및 설계 (Magnetic Force Analysis and Design Methodology of Magnetic Gear in the Magnetic Geared Motor)

  • 정광석
    • 융복합기술연구소 논문집
    • /
    • 제13권1호
    • /
    • pp.7-12
    • /
    • 2023
  • The built-in motor with an integrated magnetic gear can realize high torque without a separate reduction device. In this paper, the main design parameters of the magnetic gear constituting the magnetic geared motor are derived and the sensitivity analysis results according to these design parameters are discussed. In particular, processing and assembly issues of modulators sandwiched between rotating bodies are discussed, and loss and magnetic force characteristics of various types of modulators are introduced. Since the modulator, which plays a key role in converting the torque of the magnetic gear, is desirable to have a separate form, it is inevitable to add a non-magnetic support to add torsional stiffness according to high-speed rotation, so the effect of this is also analyzed.

배관 재료의 물성을 고려한 내진설계 방법에 관한 연구 (A Study on Seismic Design Method Considering Physical Properties of Piping Material)

  • 방대석;이재오
    • 한국화재소방학회논문지
    • /
    • 제32권2호
    • /
    • pp.38-47
    • /
    • 2018
  • 본 연구에서는 배관 재료의 물성을 고려한 공학적 내진설계방식과 소방시설의 내진설계의 기준에 따른 사양위주의 설계방식에 대하여 비교 분석하였다. 배관 재료의 물성을 고려한 내진설계 방식의 경우는 배관에서 발생되는 비틀림 응력과 굽힘 응력의 합성 값을 통해 배관의 안전성을 분석하게 된다. 하지만 사양위주의 설계방식의 경우는 배관 재료의 안전성이 아니라 배관이 움직이는 힘을 해석하여 흔들림 방지버팀대가 견딜 수 있는지 여부를 해석하고 있다. 소화배관은 하나의 연결된 구조체로 일정구간에서 발생되는 흔들리는 힘을 통해서는 배관의 안전성을 보장받을 수 없기 때문에 배관 재료의 응력과 변위의 안전성 분석을 통해서 가능하다. 그러므로 안전성 있는 소화 설비 배관의 내진설계를 위해서는 배관 재료의 물성과 건축 구조물의 내진성능을 고려한 해석방법을 적용할 필요가 있다.

유압식 확장기가 내장된 오거 크레인의 특성 및 신뢰성 평가 (Evaluation of Characteristics and Reliability of an Auger Crane with Built-in Hydraulic Extender)

  • 김점식;권신원
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.77-82
    • /
    • 2010
  • This study evaluated the characteristics and reliability of an auger crane with a built-in hydraulic extender. The field test of the hydraulic extender was performed with the hydraulic lines filled with hydraulic fluid and free of air. The pressure generated during the test was measured with a digital pressure gauge. The crane was considered to have undergone one cycle of the excavation process after it had performed excavation under three conditions at the same location. This process was performed three times in total. From the results of the excavation using the hydraulic extender, it was found that the maximum pressure and torque measured were 19.9 [MPa] and 895.4 [$kgf{\cdot}m$], respectively. The rotation force of the auger crane generated at this time signifies a horizontal force. If the excavation diameter of the auger crane is increased, the rotation speed is reduced causing the circumferential speed to also be reduced. The torsional shear stress of the extendable auger crane was calculated to be approximately 23.5 [MPa]. However, the rotation shaft material used for this system was carbon steel for machine structural use (SM45C). Since the minimum torsional yield stress is greater than 150 [MPa] according to KS D 3752, it means the equipment has secured a safety factor greater than 6. Therefore, it was found that when performing work using the extendable auger crane, it exhibited no problems with the safety and reliability of its shaft.

Investigation on the performance of a new pure torsional yielding damper

  • Mahyari, Shahram Lotfi;Riahi, Hossein Tajmir;Esfahanian, Mahmoud Hashemi
    • Smart Structures and Systems
    • /
    • 제25권5호
    • /
    • pp.515-530
    • /
    • 2020
  • A new type of pure torsional yielding damper made from steel pipe is proposed and introduced. The damper uses a special mechanism to apply force and therefore applies pure torsion in the damper. Uniform distribution of the shear stress caused by pure torsion resulting in widespread yielding along pipe and consequently dissipating a large amount of energy. The behavior of the damper is investigated analytically and the governing relations are derived. To examine the performance of the proposed damper, four types of the damper are experimentally tested. The results of the tests show the behavior of the system as stable and satisfactory. The behavior characteristics include initial stiffness, yielding load, yielding deformation, and dissipated energy in a cycle of hysteretic behavior. The tests results were compared with the numerical analysis and the derived analytical relations outputs. The comparison shows an acceptable and precise approximation by the analytical outputs for estimation of the proposed damper behavior. Therefore, the relations may be applied to design the braced frame system equipped by the pure torsional yielding damper. An analytical model based on analytical relationships was developed and verified. This model can be used to simulate cyclic behavior of the proposed damper in the dynamic analysis of the structures equipped with the proposed damper. A numerical study was conducted on the performance of an assumed frame with/without proposed damper. Dynamic analysis of the assumed frames for seven earthquake records demonstrate that, equipping moment-resisting frames with the proposed dampers decreases the maximum story drift of these frames with an average reduction of about 50%.