• 제목/요약/키워드: torque ratio

검색결과 675건 처리시간 0.028초

정면밀링공정중 추축모터전류를 이용한 절입비의 실시간 추정 (In-process Immersion Ratio Estimation Using Spindle Motor Current during Face Milling)

  • 조규진;오영탁;권원태;주종남
    • 한국생산제조학회지
    • /
    • 제9권6호
    • /
    • pp.57-64
    • /
    • 2000
  • In order to regulate cutting torque in milling, monitoring system should be set to a certain threshold. Radial immersion ratio is an important factor to determine the threshold and should be estimated in process for automatic regulation. In this paper, on-line estimation of the radial immersion ratio using spindle motor current in face milling is presented. When a tooth finishes sweeping, a sudden drop of cutting torque occurs. This torque drop is equal to the cutting torque acting on a single tooth at the swept angle of cut and can be acquired from cutting torque signals. Average cutting torque per revolution can also be calculated from cutting torque signals. The ratio of cutting torque acting on a single tooth at the swept angle of cut to the average cutting torque per revolution is a function of the swept angle of cut and the number of teeth. Using the magnitude of this ratio, the radial immersion ratio is estimated. Identical algorithm is adopted to estimate the immersion ratio based on the spindle motor current measurement. The experiments performed under different cutting conditions show that the radial immersion ratio can be estimated within 10% error range by the proposed method using spindle motor current. Varying immersion ratio is also estimated well using the presented algorithm.

  • PDF

밀링공정에서 주축모터전류를 이용한 절입비 추정 (Immersion Ration Estimation Using Spindle Motor Current during Milling)

  • 조규진;권원태;조동우;주종남
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.222-229
    • /
    • 1999
  • In order to regulate cutting torque in milling, monitoring system should be set to a certain threshold. Radial immersion ratio is an important factor to determine the threshold and should be estimated in process for automatic regulation. In this paper, on-line estimation of the radial immersion ration using spindle motor current in face milling is presented. When a tooth finishes sweeping, a sudden drop of cutting torque occurs. This torque drop is equal to cutting torque acting on a single tooth at the swept angle of cut and can be acquired form cutting torque signals. Average cutting torque per revolution can also be calculate form cutting torque signals. The ratio of cutting torque acting on a single tooth at the swept angle of cut to the average cutting torque per revolution is a function of the swept angle of cut and the number of teeth. Using the magnitude of this ratio, the radial immersion ratio is estimated. Identical algorithm is adopted to estimate the immersion ratio based on the spindle motor current measurement. The experiments performed under different cutting conditions show that the radial immersion ratio can be estimated within 10% error range by the proposed method using spindle motor current.

  • PDF

A New Direct Torque Control Scheme of an Induction Motor Using Duty Ratio Modulation

  • Park, Jeong-Woo;Lee, Dong-Myung
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1223-1231
    • /
    • 2018
  • The direct torque control (DTC) scheme features a simple structure thanks to stator flux-oriented control. It has the advantage of robustness against motor parameters variation since only the stator resistance is involved in the control scheme. On the other hand, the disadvantage of DTC is large torque ripple. To reduce the torque ripple, many studies on DTC-space vector modulation (DTC-SVM) schemes, which modulate the duty ratio with a fixed switching cycle, have been proposed. However, there is the difficulty in obtaining the duty ratio for DTC-SVM. Hence, this paper proposes a new duty ratio selection and stator flux calculation methods for reducing torque ripple. Simulations and experiments were carried out to determine the validity of the proposed method. The proposed scheme has simplified the duty ratio command and achieved the same control performance as the conventional duty ratio modulation method without using the information of motor parameters.

중부하 토크 컨버터의 실험적 성능분석 (Experimental Investigation and Performance Test of Heavy Duty Torque Converter)

  • 이해종;김세현;이중섭;이상철;정효민;정한식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.690-695
    • /
    • 2004
  • The present study is an investigation on the characteristics of heavy load toque converter by experimental process. To get the dynamic performance, the dynamometer was used with a parameters of speed, torque, oil pressure and oil flux, etc. The torque converter was tested for various input speed, output oil pressure and input oil flow rate. All experiments were investigated in case that the speed ratio is increased. The torque ratio and capacity factor was in inverse proportion to speed. Engine revolution had a more effects at region of low speed ratio. But, the opposite phenomena were represented increase of efficiency. In result of this experiments, the characteristics of torque converter were not influenced by oil pressure and oil flux.

  • PDF

21-68세 남녀 100명의 슬관절 굴근과 신근의 근력에 대한 등속성 평가 (Isikinetic evaluation of the knee flexors and extensors on muscle strength in 100 men and women aged 21 - 68yr)

  • 남형천
    • 대한물리치료과학회지
    • /
    • 제8권2호
    • /
    • pp.967-976
    • /
    • 2001
  • The purpose of the present study was to the investigate the effect of aging in men and women on muscle strength of knee extensor and flexors by using the cybex 6000 isokinetic dynamometer. A total of 100 volunteers participated in this study and were divided into five groups according to their chronological age as follows: 20s, 30s, 40s, 50s, 60s, 10 men and 10 women in each decade respectively. Isokinetic ($60^{\circ}{\cdot}s-l$) knee extensor and flexor peak torque, peak torque to body weight ratio, opposing muscles(flexor/extensor) peak torque ratio, deficit of peak torque between dominant and non-dominant were measured. The results obtained were as follows: 1) In men, While the aged increased. the peak torque of the knee flexor and extensor statistically sig nificant decreased in the dominant and non-dominant side. 2) In women, Statistically significant difference of knee extensor peak torque was found as the aged increased in the dominant and non-dominant side, but significant difference of knee flexor peak torque did not that. 3) In men, No significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the non-dominant side, but statistically significant difference in the peak torque of knee flexor to body weight weight ratio was found as the aged increased in the dominant side. 4) In women. No significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the dominant side, but statistically significant difference in the peak torque of knee flexor to body weight ratio was found as the aged increased in the non-dominant side. 5) In men and women, While the aged increased, statistically significant difference was found the dominant and non-dominant side in the peak torque of knee extensor to body weight ratio. 6) Peak torque of hamstring to quadriceps ratio of dominant and non-dominant side in men and women were not significantly different as the age increases. 7) Mean deficit of peak torque between dominant and non-dominant side in men and women were not significantly different as the age increases. From these results we conclude a proper exercise program is need before 50s decade to preserve in muscle strength of knee flexors and extensors.

  • PDF

극호비 변화에 따른 영구자석 매입형 동기전동기의 토크 특성 해석 (Torque Characteristics Analysis of Interior Permanent Magnet Synchronous Motor According to Pole Arc Ratio)

  • 이갑재;김기찬;이종인;권중록
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권2호
    • /
    • pp.81-87
    • /
    • 2005
  • The torque characteristics of permanent magnet(PM) motor is varied according to magnet width. In this paper, the design method of magnet and magnetic circuit is proposed in order to improve the torque of Interior Permanent Magnet Synchronous Motor(IPMSM). This paper presents the effects of pole arc ratio and salient pole ratio on the torque and torque ripple in the IPMSM with concentrated winding.

분수슬롯을 가진 영구자석 전동기에서 극당 슬롯 비율이 코깅토크와 역기전력에 미치는 영향 (Effect of Pole to Slot Ratio on Cogging Torque and EMF Waveform in Permanent Magnet Motor with Fractional-Slot)

  • 이갑재;이주
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권9호
    • /
    • pp.454-459
    • /
    • 2003
  • Conventional integral-slot design in permanent magnet(PM) motor tends to have a high cogging torque and large end turns, which contribute to copper losses. The fractional-slot design is effective compared to integral-slot design in the cogging torque and electromotive force(EMF) waveform. The effectiveness of fractional slot can be maximized by selecting optimal pole to slot ratio. This paper presents the effect of pole to slot ratio on the cogging torque and EMF waveform in the PM motor with fractional-slot. The effectiveness of the proposed designs has been confirmed by comparing waveform of EMF. cogging torque and torque ripple between conventional and new models.

토크예측제어를 이용한 매입형 영구자석 동기전동기의 토크리플저감기법 (Torque Ripple Reduction of Interior Permanent-Magnet Synchronous Motors Driven by Torque Predictive Control)

  • 김현섭;한정호;송중호
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.102-109
    • /
    • 2013
  • In this paper, a new torque predictive control method of interior permanent magnet synchronous motor is developed based on an extended rotor flux. Also, a duty ratio prediction method is proposed and allows the duty ratio of the active stator voltage vector to be continuously calculated. The proposed method makes it possible to relatively reduce the torque ripple under the steady state as well as to remain the good dynamic response in the transient state. With the duty ratio prediction method, the magnitude and time interval of the active stator voltage vector applied can be continuously controlled against the varying operation conditions. This paper shows a comparative study among the switching table direct torque control(DTC), the SVM-DTC, conventional torque predictive control, and the proposed torque predictive control. Simulation results show validity and effectiveness of this work.

토크 컨버터 내부의 비정상 후류 유동특성에 대한 수치해석 연구 (A Numerical Study of Unsteady Wake Flow Characteristics in a Torque Converter)

  • 원찬식;허남건
    • 한국유체기계학회 논문집
    • /
    • 제9권5호
    • /
    • pp.36-41
    • /
    • 2006
  • In the present study, a transient incompressible viscous turbulent flow is simulated for the automotive torque converter with moving mesh technique. For the analysis, entire torque converter flow passages are modeled. Computed torque ratio, capacity factor and efficiency show a good agreement with the experiment data. The flow instabilities characterized by back-flow and wake etc. appeared in some cascade passages are shown to be propagating along tangential direction. These flow patterns are mainly influenced by the pump and turbine blade passing and can't be predicted through conventional steady simulation with a mixing plane approach. The understanding of the unsteady flow characteristics in a torque converter achieved in the present study may lead to the optimal design of a torque converter.

넓은 환상간극을 가진 동심원통속의 couette 흐름에서 고분자수용액의 유동현상 (A flow phenomenon of aquaous polymer solution in couette flow of concentric cylinder with wide circular)

  • 권혁칠;이성노;정진도
    • 오토저널
    • /
    • 제15권3호
    • /
    • pp.81-88
    • /
    • 1993
  • This report describes the experimental research on the flow phenomena of the aq uaous polymer solution within the Cuette flow of the concentric, cylinders type with a wide circular gap. We have investigated the phenomena of the fluid flow through torque measuring in the system that the inner cylinder is stationary and the outer one is rotating. Geometrical parameters of the system are the gap ratio of t/R$_{0}$=0.2 and Aspect ratio of l/t=100. The torque increases considerably in about 420-480RPM, So, it is considered a turbulent transition boundary, the higher plymer concentration is, the lower torque value is and the higher transition Reynolds number is. In each of the polymer concentration, the unstable boundary of torque, that is, idiosyncrasies of torque is observed around 220-280RPM. and the boundary is looked upon as a resonant vibration which is caused by the inner cylinder and tortional vibration of torque sensor.r.

  • PDF