• 제목/요약/키워드: top-contact

검색결과 308건 처리시간 0.028초

한국 여성 노인을 대상으로 한 피트니스 압박웨어 선호도 및 착용 특성 평가 (Evaluation of Preference and Wearing Characteristics of Fitness Compression wear for Korean Elderly Women)

  • 전은진;유희천;김동미;김희은
    • 한국의류산업학회지
    • /
    • 제21권3호
    • /
    • pp.336-345
    • /
    • 2019
  • This study evaluated the preference and wearing characteristics of existing fitness compression wear for elderly women and identified the problems and improvements of existing fitness apparel. Preference and wearing characteristics for 6 types (A-F) of upper and lower fitness compression wear were evaluated. Photos and drawings as well as the preferred designs and details were investigated after presenting the evaluation clothing. Evaluations were made on a 5 point Likert scale for the fitness, allowance, pressure, ease of movement, fabric material, and overall satisfaction after wearing. The design preference indicated that B type (26.6%) and C type (23.4%) were preferred in the top with C, E and F type preferred to the same ratio of 19.4% in the slacks. The fitness and allowance amount of the top B type were the most appropriate (${\geq}4$), the C type was in close contact (2.86), and the F type was inadequate in the neck circumference (1.77). The feeling of pressure was high in the waist, abdomen, thighs, and knees. The area where the elderly people want to improve their strength was the legs; in addition, a pattern design was needed to strengthen leg muscles when designing fitness compression wear. However, a design with excessive adhesion due to a muscle support band was shown to be not preferred. Therefore, depending on the activity, it is necessary to develop a fitness compression wear that applies an optimum stretching ratio of fabric based on body surface area changes.

Post Ru CMP Cleaning for Alumina Particle Removal

  • Prasad, Y. Nagendra;Kwon, Tae-Young;Kim, In-Kwon;Park, Jin-Goo
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.34.2-34.2
    • /
    • 2011
  • The demand for Ru has been increasing in the electronic, chemical and semiconductor industry. Chemical mechanical planarization (CMP) is one of the fabrication processes for electrode formation and barrier layer removal. The abrasive particles can be easily contaminated on the top surface during the CMP process. This can induce adverse effects on subsequent patterning and film deposition processes. In this study, a post Ru CMP cleaning solution was formulated by using sodium periodate as an etchant and citric acid to modify the zeta potential of alumina particles and Ru surfaces. Ru film (150 nm thickness) was deposited on tetraethylorthosilicate (TEOS) films by the atomic layer deposition method. Ru wafers were cut into $2.0{\times}2.0$ cm pieces for the surface analysis and used for estimating PRE. A laser zeta potential analyzer (LEZA-600, Otsuka Electronics Co., Japan) was used to obtain the zeta potentials of alumina particles and the Ru surface. A contact angle analyzer (Phoenix 300, SEO, Korea) was used to measure the contact angle of the Ru surface. The adhesion force between an alumina particle and Ru wafer surface was measured by an atomic force microscope (AFM, XE-100, Park Systems, Korea). In a solution with citric acid, the zeta potential of the alumina surface was changed to a negative value due to the adsorption of negative citrate ions. However, the hydrous Ru oxide, which has positive surface charge, could be formed on Ru surface in citric acid solution at pH 6 and 8. At pH 6 and 8, relatively low particle removal efficiency was observed in citric acid solution due to the attractive force between the Ru surface and particles. At pH 10, the lowest adhesion force and highest cleaning efficiency were measured due to the repulsive force between the contaminated alumina particle and the Ru surface. The highest PRE was achieved in citric acid solution with NaIO4 below 0.01 M at pH 10.

  • PDF

곡면형 압전 복합재료 작동기 LIPCA 개발 (Development of Lightweight Piezo-composite Curved Actuator)

  • 박기훈;윤광준;박훈철
    • 한국항공우주학회지
    • /
    • 제30권5호
    • /
    • pp.94-100
    • /
    • 2002
  • 본 논문은 곡면형 압전 복합재료 작동기 LIPCA의 개발 및 성능 실험에 관한 것이다. LIPCA는 압전 세라믹을 중심으로 상층부는 탄성계수가 크면서 열팽창계수가 낮은 섬유강화 복합재료층이 위치하며, 하층부는 탄성계수가 작으면서 열팽창계수가 큰 섬유강화 복합재료층이 위치한다. 작동기의 성능 검증을 위해 작동지그 및 전압 공급 장치 그리고 비접촉 레이저 센서로 이루어진 실험 시스템을 구성하였다. 성능 실험은 양단 단순지지상태에서 압전 재료의 전극에 $100\sim400V_{pp}$의 교류 전압을 1Hz로 가하였을 경우 작동기 중앙부에서 발생하는 수직방향의 변위를 측정하는 것으로 수행하였다. LIPCA와 THUNDER의 성능 검증 결과 LIPCA-C2는 THUNDER에 비해 34% 경량화 되었으며, 작동변위는 13% 향상되었다.

모핑을 이용한 화상회의의 시선 맞춤 보정 방법 (Mutual Gaze Correction for Videoconferencing using View Morphing)

  • 백으뜸;호요성
    • 스마트미디어저널
    • /
    • 제4권1호
    • /
    • pp.9-15
    • /
    • 2015
  • 언어를 사용하지 않고 몸짓이나 손짓, 표정 등 신체의 동작으로 의사나 감정을 표현하고 전달하는 비언어적 전달 방법은 중요한 의사전달 방법 중 하나이다. 이러한 몸짓이나, 손짓, 시선 맞춤 그리고 손동작은 때론 말보다 더 강력한 의사전달의 방법으로 작용한다. 비언어적 의사전달 방법에서 시선 맞춤은 그중에서도 가장 중요한 의사전달 방법이다. 하지만 화상회의를 할 때 디스플레이 상에서의 눈과 카메라의 차이 때문에 상호간에 시선 맞춤이 되지 않는다. 만약 상호간에 시선 맞춤을 하지 않고 대화를 하면 정확한 의사전달이 힘들고 서로의 이야기에 집중하기 어려워진다. 본 논문에서는 화상회의 상황에서 시선 맞춤을 개선하는 방법을 제안한다. 시선 맞춤을 개선하기 위해 두 대의 카메라를 텔레비전의 위, 아래에 설치하였다. 동시에 두 영상을 촬영하여 2D 워핑을 하여 가상의 중간시점으로 옮기고, 뷰 모핑을 한다. 모핑된 얼굴과 배경영상을 합성하여 화상회의를 위해 개선된 시선 맞춤 영상을 만든다. 실험 결과를 통하여 제안한 알고리즘이 시선 맞춤을 개선하고 자연스러운 중간 시점 영상을 합성하는 것을 확인 할 수 있다.

배드민턴 포핸드 헤어핀 동작 시 숙련 정도에 따른 손가락 압력 및 운동학적 변인 비교 분석 (A Comparative Analysis of the Finger Pressure and Kinematic Variables in the Forehand Hairpin Net Shot According to Proficiency)

  • 이행섭;채원식;정재후
    • 한국운동역학회지
    • /
    • 제22권4호
    • /
    • pp.387-394
    • /
    • 2012
  • The purpose of this study was to compare and analyze the finger pressure and kinematic variables in the forehand hairpin net shot between skilled elite players and less skilled recreational players. Eight elite players(age: $18.1{\pm}0.8yrs$, height: $176.8{\pm}1.5cm$, weight: $640.9{\pm}48.6N$) with minimum of 6 years of experience and eight recreational players(age: $27.9{\pm}1.6yrs$, height: $177.1{\pm}6.1cm$, weight: $820.5{\pm}62.8N$) with less than one year experience were recruited in this study. For each trial being analyzed, four critical instants were identified from the video recordings: Right heel contact1 (E1), Right toe-off (E2), Right heel contact2 (E3), and Shuttlecock Impact (E4). Each hairpin net shot was broken into consecutive phases: E1~E2 (Right Landing Phase: RLP), E2~E3 (Sliding Step Phase: SSP), and E3~E4 (Impact Phase: IP). Temporal parameters, shuttlecock speed, linear and angular kinematics of body segments, and finger pressures were computed for this study. The results showed that The finger pressure of the ring finger and the middle finger for the skilled group during an impact had significantly greater than those of unskilled group. It is possible that all fingers were not used in the same manner when the racket was gripped in forehand hairpin. The result also suggested that the ring finger and the middle finger pushed the racket from top to bottom while having the mid-phalanx and proximal phalanx of index finger as an axis.

Calibration-free real-time organic film thickness monitoring technique by reflected X-Ray fluorescence and compton scattering measurement

  • Park, Junghwan;Choi, Yong Suk;Kim, Junhyuck;Lee, Jeongmook;Kim, Tae Jun;Youn, Young-Sang;Lim, Sang Ho;Kim, Jong-Yun
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1297-1303
    • /
    • 2021
  • Most thickness measurement techniques using X-ray radiation are unsuitable in field processes involving fast-moving organic films. Herein, we propose a Compton scattering X-ray radiation method, which probes the light elements in organic materials, and a new simple, non-destructive, and non-contact calibration-free real-time film thickness measurement technique by setting up a bench-top X-ray thickness measurement system simulating a field process dealing with thin flexible organic films. The use of X-ray fluorescence and Compton scattering X-ray radiation reflectance signals from films in close contact with a roller produced accurate thickness measurements. In a high-thickness range, the contribution of X-ray fluorescence is negligible, whereas that of Compton scattering is negligible in a low-thickness range. X-ray fluorescence and Compton scattering show good correlations with the organic film thickness (R2 = 0.997 and 0.999 for X-ray fluorescence and Compton scattering, respectively, in the thickness range 0-0.5 mm). Although the sensitivity of X-ray fluorescence is approximately 4.6 times higher than that of Compton scattering, Compton scattering signals are useful for thick films (e.g., thicker than ca. 1-5 mm under our present experiment conditions). Thus, successful calibration-free thickness monitoring is possible for fast-moving films, as demonstrated in our experiments.

건설현장의 추락 및 접촉사고 방지를 위한 스마트 세이프티 센서 개발 (Development of Smart Safety Sensors to Prevent Falling and Contact Accidents at Construction Sites)

  • 이주희;안요섭
    • 한국건설관리학회논문집
    • /
    • 제22권1호
    • /
    • pp.47-54
    • /
    • 2021
  • 한국산업안전보건공단의 산업재해통계 보고서 최근 4년 동안의 자료를 확인하면 2017년부터 2020년 6월까지 건설현장의 재해자 수가 약 93,158명, 사망자 수가 약 1,977명으로 건설업이 재해율 총 3위, 사망률 총 1위로 높은 안전사고 추이를 보이고 있다. 그 중에서도 전체 직업군에서 추락으로 인한 사망사고 및 접촉으로 인한 사망사고는 전체 사고 유형 중 3위 안으로 빈번하게 발생하는 안전사고이다. 본 논문은 건설현장의 다양한 유형의 안전사고 중 발생 비율이 가장 높은 추락과 접촉 사고 두 유형의 안전사고를 예방하기 위해 초음파 센서를 이용한 스마트 감지 장치를 개발하여 직접 현장 작업자가 경험하게 한 결과, 설문참여 작업자의 69.5%이상이 센서의 현장 적용성에 대해 긍정적으로 평가하였으며, 이를 토대로 건설업 안전사고의 전체 비율을 감소하는데 일조 하고자 한다.

Preparation of Poly(vinylidene fluoride)-g-poly(methacrylic acid) Composite Nanofiltration Membrane

  • Kim, Yong-Woo;Choi, Jin-Kyu;Koh, Joo-Hwan;Kim, Jong-Hak
    • Korean Membrane Journal
    • /
    • 제9권1호
    • /
    • pp.57-63
    • /
    • 2007
  • Amphiphilic graft copolymer from poly(vinylidene fluoride) (PVDF) was synthesized using atom transfer radical polymerization (ATRP) for composite nanofiltration membranes. Direct initiation of the secondary fluorinated site of PVDF facilitates grafting of tert-butyl methacrylate (tBMA). Amphiphilic PVDF-g-PMAA graft copolymer with a 51:49 wt ratio was obtained by hydrolyzing poly(tert-butyl methacrylate) (PtBMA) to poly(methacrylic acid) (PMAA). Wide angle X-ray scattering (WAXS) and differential scanning calorimetry (DSC) confirmed the decrease of crystallinity of PVDF upon graft copolymerization. Composite nanofiltration membranes were prepared from PVDF-g-PMAA as a top layer coated onto PVDF ultrafiltration (UF) support membrane. The morphology and hydrophilicity of membranes were characterized using scanning electron microscopy (SEM) and contact angle measurement. The rejections of composite membranes were 80.2% for $Na_2SO_4$ and 28.4% for NaCl, and the solution flux were 9.5 and $14.5\;L/m^2\;h$ at 1.0 MPa pressure.

Assessment of Requirements for Successful Mobile Project Management Information Systems

  • Lee, Ung-Kyun;Jeong, Hyung Seok David;Woldesenbet, Asregedew
    • 한국건축시공학회지
    • /
    • 제14권1호
    • /
    • pp.45-53
    • /
    • 2014
  • The objective of this study is to assess the requirements of tablet PC-based PMIS applications designed for use on construction sites to determine whether these new programs can play a significant role in increasing the efficiency of a project. In this research, the current market conditions of PMIS running on a tablet PC were analyzed. In addition, two industry surveys were conducted. A research team interviewed some industry experts and identified fourteen useful and desirable functions that can be incorporated into tablet PC-based applications and project management tools. Through a questionnaire survey, the most effective functions for the tablet PC-based PMIS were identified. The three top-rated functions among those suggested were Contact Information for Job-Related Personnel; Receive and Respond to Submittals, RFIs, and Notices; and Problem Solving for Design and Engineering Issues. The results of this research are expected to provide helpful information for mobile application developers and members of other interested groups in the construction industry.

Electrical Effects in Organic Thin-Film Transistors Using Polymerized Gate Insulators by Vapor Deposition Polymerization (VDP)

  • Lee, Dong-Hyun;Pyo, Sang-Woo;Koo, Ja-Ryong;Kim, Jun-Ho;Shim, Jae-Hoon;Kim, Young-Kwan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.661-664
    • /
    • 2004
  • In this paper, it was demonstrated that the organic thin film transistors with the organic gate insulators were fabricated by vapor deposition polymerization (VDP) processing. The configuration of OTFTs was a staggered-inverted top-contact structure and gate dielectric layer was deposited with 0.45 ${\mu}m$ thickness. In order to form polyimide as a gate insulator, VDP process was also introduced instead of spin-coating process. Polyimide film was respectively co-deposited with different materials. One was from a 4,4'-oxydiphthalic anhydride (ODPA) and 4, 4'-oxydianiline (ODA) and the other was from 2,2-bis(3,4-dicarboxyphenyl) hexafluoropropane dianhydride (6FDA) and ODA. And it was also cured at 150 $^{\circ}C$ for 1 hour followed by 200 $^{\circ}C$ for 1 hour. Electrical characteristics of the organic thin-film transistors were detailed comparisons between the ODPA-ODA and the 6FDA-ODA which were used as gate insulator.

  • PDF