• Title/Summary/Keyword: tooth abrasion

Search Result 69, Processing Time 0.031 seconds

Analysis of the Difference in the Importance of Instructors and Clinical Dental Hygienists for Oral Pathology Learning Objectives

  • Lee, Sun-Mi;Lee, Jung–Hwa;Cho, Eunae Sandra
    • Journal of dental hygiene science
    • /
    • v.22 no.1
    • /
    • pp.9-19
    • /
    • 2022
  • Background: The purpose of this study was to identify the differences in the importance of oral pathology learning objectives for instructors and clinical dental hygienists and provide basic data that can guide learning objectives for acquiring practically necessary basic knowledge in the clinical field. Methods: Through the first-stage expert meeting, 27 items with less than four points out of 129 learning objectives in 15 detailed areas were deleted, 12 additional opinions were reflected, 114 learning objectives were set, and a survey was conducted with 253 people. Results: There were statistically significant differences in 92 items after examining the difference between professors and clinical dental hygienists. Among the areas of inflammation and repair, "Can explain the five symptoms of inflammation" had the highest with a score at 4.76 in the case of the professors. Among the areas of tooth damage, "Can explain abrasion" had the highest with a score at 4.61 in the case of the clinical dental hygienists. Conclusion: I would like to propose the existing 15 detail areas and 129 learning objectives as 14 detail areas and 98 learning objectives and strengthen the job competency of dental hygienists in the future. First, you need to develop competencies that are highly relevant to your work. Second, it is necessary to develop related textbooks and educational materials based on revised learning objectives and competencies. Third, based on revised learning objectives, the dental hygienist national examination should be improved. Through these changes in education, the education of oral and maxillofacial disease subjects should strengthen job competencies among dental hygienists with learning objectives that can be applied to actual clinical practice based on basic knowledge rather than knowledge orientation. In addition, it is possible to improve the quality of dental hygiene studies.

A STUDY ON THE ENAMEL EROSION BY CARBONATED BEVERAGE (탄산음료의 법랑질 침식효과에 대한 연구)

  • Lee, Kyung-Ho;Park, Soo-Jin;Jung, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.144-151
    • /
    • 2005
  • Erosion is believed to be the predominant cause of teeth wear in children and young adults, although there will at ways be a contribution from attrition and abrasion. The pH of cola is known to be low and have, therefore, been implicated in the increasing incidence of erosion. The aim of present study was to evaluate the effect of cola on the progression of erosive demineralization in human enamel using demineralization model in vitro. Six groups of human enamel slap were immersed(5 min each bath) in fresh cola, with immersions taking place with or without agitation, and under 3 regimes of frequency intake(low intake, 1 immersion/day; medium, 5/day; high, 10/day). Quantitative assessments of surface erosion were done over an 8-day interval using surface microhardness testing. 1. The average pH of cola was 2.5, which was acidic enough to cause tooth erosion. 2. All the enamel specimen exposed to cola showed erosion like lesions and surface hardness decreased in proportion to the length of immersion (p<0.05). 3. The surface hardness of enamel decreased in proportion to the frequency of immersion (p<0.05). 4. Increased degassing from the drink by gitation accelerated the enamel softening compared with those without agitation.

  • PDF

COMPARISON OF MECHANICAL PROPERTIES IN 4 INDIRECT COMPOSITE RESIN (4종의 간접법용 복합 레진의 기계적 특성 비교)

  • Kim, Kil-Soo;Yoon, Tae-Ho;Song, Kwang-Yeob;Ahn, Seung-Geun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.1
    • /
    • pp.21-33
    • /
    • 2007
  • Statement of problem: The esthetic component of dental care has become increasingly more important, while new tooth-colored materials are continually marketed. Various new indirect composite materials have been developed with required advantages. The most recent development in the indirect composites has been the introduction of the second-generation laboratory composite or poly-glass materials. They are processed by different laboratory techniques based on combinations of heat, pressure, vacuum and light polymerization. Although, second generation products became available in 1995, their characteristics and clinical performance have not been adequately investigated. Purpose: The aim of this study was to measure the mechanical properties of the second generation indirect resin system and compare these with an existing universal direct composite resin. Material and method: In this study four indirect composite material (Adoro LC, BelleGlass HP, Tescera, Synfony) were tested for flexural strength, wear resistance, hardness and their degree of conversion against Z250, a light cure direct composite. Results: Within the limitations of this study, the following conclusions were drawn: 1. From the abrasion wear result, Adoro showed the least volume loss while Synfony showed the greatest volume loss. Z250 and BelleGlass HP didn't show significant difference (p>0.05), but they showed significant difference with other groups (p<0.05). From the attrition wear, BelleGlass HP showed the least volume loss and it didn’t show significant difference with Tescera (p>0.05). While Synfony showed the greatest volume loss that it showed significant difference with other groups (p>0.05). 2. Mean values of flexural strength by means of three point bending test was in the order of Z250, Adoro, Belleglass HP, Tescera and Synfony. Mean elastic modulus was in the order of Z250, BelleGlass HP, Tescera, Adoro and Synfony. 3. The result of Vicker‘s microhardness value showed that significantly higher value in Z250 (p<0.05), and is in the order of BelleGlass HP, Tescera, Adoro and Synfony. 4. The degree of conversion measured by FT-IR showed significantly higher value in BelleGlass HP (p<0.05), and is in the order of Adoro, Synfony, Tescera and Z250. Conclusion: Significant differences were found in the flexural strength, wear resistance, hardness and their degree of conversion.

A SCANNING ELECTRON MICROSCOPIC STUDY OF BONDING ASPECTS TO THE SCLEROTIC DENTIN (경화된 상아질의 접합 양상에 관한 주사전자현미경적 연구)

  • Lee, Rin;Lee, Hyeong-Il;Lee, Kwang-Won;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.228-243
    • /
    • 1997
  • The changes of microstructures, morphology of sclerotic dentin and bonding aspects generated by an adhesive resin was investigated. Incisors and premolars showing natural cervical abrasions were collected and conditioned with 10 % phosphoric acid or 10 % maleic acid. The sclerotic dentin specimens were then rinsed and blot-dried and applied with dentin adhesive (All Bond 2) to the conditioned dentin surface. To examine the morphologic change of the sclerotic dentin specimen after etching and bonding procedure, the treated specimens were examined by SEM. To analyze the chemical composition of sclerotic dentin and crystals occluding dentinal tubules, the sclerotic dentin specimen was powdered and examined with X-ray Diffractometer. To investigate the Ca/P weight percent ratio within the dentinal tubules, the sclerotic dentin specimen was fractured perpendicularly to the long axis of the tooth from the center of cervical abrasion lesion and then examined with EDX(Energy Dispersive X-ray) microanalyzer. The results were as follows : 1. The increased width of peritubular dentin and the depositions of the irregular amorphous materials within the dentinal tubules were showed in the sclerotic dentin specimens. 2. After the treatment of sclerotic dentin specimen with 10 % phosphoric acid or 10 % maleic acid, the lateral side of tubules rather than cross-sectional tubule openings was showed exclusively at the incisal and gingival incline of the specimens. 3. After the treatment of sclerotic dentin specimen with 10 % phosphoric acid or 10 % maleic acid, the hybrid layer was not formed evidently and the resin tag was not formed or shortly penetrated into the tubules with the thinner diameter. 4. According to the results of XRD analysis of the sclerotic dentin specimen, Hydroxyapatite and Octacalcium phosphate were predominent, however, Whitlockite crystals were rare. 5. The mean Ca/P weight percent ratio analysed from 5 fractured sclerotic dentin specimens was $2.322{\pm}0.170$ at the intertubular dentin, $1.826{\pm}0.051$ within the dentinal tubule.

  • PDF

THE SEM STUDY ABOUT THE MORPHOLOGICAL CHANGES OF THE DENTINAL SURFACE IRRADIATED WITH Nd : YAG LASER (Nd : YAG 레이저를 조사한 상아질 표면변화에 관한 주사전자현미경적 연구)

  • Lim, Sung-Sam;Yoon, Soo-Han;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.479-489
    • /
    • 1997
  • The purpose of this study was to evaluate the effect of the Nd : YAG laser on the tooth hypersensitivity by the observation of the morphological changes of the dentinal surface irradiated with Nd : YAG laser by use of SEM. In 40 mandibular and maxillary molars without any carious lesion or restoration, severe attrition and abrasion, Enamel was removed with fine grit diamond bur and exposed dentinal surfaces were polished with Soflex discs. In control group (10 teeth), exposed dentinal surfaces were acid-etched with 10 % Maleic acid for 15 seconds. In the experimental group 1 (10 teeth), acid-etched dentinal surfaces with 10% Maleic acid were prepared by Nd : YAG laser (6 watts power, 1 psi water, 18 psi air) for 2 minutes. In the experimental group 2 (10 teeth), exposed dentinal surfaces were irradiated with Nd: YAG laser (10 watts power, 3 psi water, 10 psi air) until the painted black stains on the dentinal surfaces were completely removed. In the experimental group 3 (10 teeth). dentinal surfaces were prepared with Nd : YAG laser (6 watts power, 1 psi water, 18 psi air) until the painted black stanins on them were completely removed and then the irradiated dentinal surfaces were acid-etched with 10 % Maleic acid for 15 seconds. The specimens were routinely processed and observed with scanning electron microscope. The results were as follows : 1. In the irradiated dentinal surfaces, the characteristics of the melting and recrystalization on the dentinal surfaces were observed. Compared with the results in the control group, we could observe that in the irradiated dentinal surfaces, the aperture of the dentinal tubules were reduced and there were more debris obstructing the dentinal tubules. 2. In the irradiated dentinal surfaces, crater structures were commonly present and in the crater bottoms, there were a lot of bead like melted dentin structures, which had the ruptured opening in the center of them. 3. The melted dentins and cracks in the smear layer were less frequently observed in the irradiated dentinal surfaces using copious cooling water than in the irradiated dentinal surfaces using scare cooling water.

  • PDF

The study on toothbrush filaments (칫솔 강모 형태에 관한 연구)

  • Han, Seung-Min;Yang, Seung-Min;Lee, Young-Moo;Ku, Young;Rhyu, In-Chul;Chung, Chong-Pyoung;Choi, Sang-Mook;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.4
    • /
    • pp.857-864
    • /
    • 2002
  • The aim of this study is to investigate the end of filaments of the different toothbrushes in the market through the stereomicroscope and to evaluate the % of rounded-end filaments considered to be acceptable. 9 brands, total 11 type toothbrushes were tested. 2 toothbrushes of each type which is marked as rounded-end filaments were tested. The toothbrushes which are not marked as rounded-end filaments were excluded. The domestic as well as foreign toothbrushes which are familiar to consumers were tested. 2 tufts of each toothbrushes were cut and examined by stereomicroscope using $40{\times}$ magnification. The procedure was carried out with blind-technique, and the digital photographs were taken. Besides the % of rounded-end filaments, total tufts number, material of the tuft, stiffness, and other special characteristics were recorded. By the classification of Silverstone and Featherstone, rounded-end filaments were examined and counted. The results shows that there are different range of rounded-end filaments according to the toothbrush types(17.7%-91.2%). Atman toothbrush has the most rounded-end filaments(91.2%) among the observed toothbrushes, and the Advantage Plus(Ora1-B) has the next(86.75%). E-Clean #411 has the least(17.70%) and E-Clean #410 of the same brand has also low % rounded-end filaments(20.60%). While G.U.M #409(Butler) has 67.90% rounded-end filaments, G.U.M #471 of the Same brand has comparative low 41.83% rounded-end filaments. 4 types of total 11 have the rounded-end filaments over 80%, however other 4 types have under even 50%. Considering that the correct brushing habit with a toothbrush which has rounded-end filaments can protect the gingival injury and tooth abrasion, it is thought that we dentists need to give the correct information about toothbrush to the patients

FINITE ELEMENT STRESS ANALYSIS OF CLASS V COMPOSITE RESIN RESTORATION SUBJECTED TO CAVITY FORMS AND PLACEMENT METHODS (와동 형태와 충전 방법에 따른 Class V 복합 레진 수복치의 유한요소법적 응력 분석)

  • Son, Yoon-Hee;Cho, Byeong-Hoon;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.91-108
    • /
    • 2000
  • Most of cervical abrasion and erosion lesions show gingival margin where the cavosurface angle is on cementum or dentin. Composite resin restoration of cervical lesion shrink toward enamel margin due to polymerization contraction. This shrinkage has clinical problem such as microleakage and secondary caries. Several methods to diminish contraction stress of composite resin restoration, such as modifying cavity form and building up restorations in several increments have been attempted. The purpose of this study was to compare polymerization contraction stress of composite resin in Class V cavity subjected to cavity forms and placement methods. In this study, finite element model of 5 types of Class V cavity was developed on computer tomogram of maxillary central incisor. The types are : 1) Box cavity 2) Box cavity with incisal bevel 3) V shape cavity 4) V shape cavity with incisal bevel 5) Saucer shape cavity. The placement methods are 1) Incisal first oblique incremental curing 2) Bulk curing. An FEM based program for light activated polymerization is not available. For simulation of curing dynamics, time dependent transient thermal conduction analysis was conducted on each cavity and each placement method. For simulation of polymerization shrinkage, thermal stress analysis was performed with each cavity and each placement method. The time-temperature dependent volume shrinkage rate, elastic modulus, and Poisson's ratio were determined in thermal conduction data. The results were as follows : 1. With all five Class V cavifies, the highest Von Mises stress at the composite-tooth interface occurred at gingival margin. 2. With box cavity, V shape cavity and saucer cavity, Von Mises stress at gingival margin of V shape cavity was lower than the others. And that of box cavity was lower than that of saucer cavity. 3. Preparing bevel at incisal cavosurface margin decreased the rate of stress development in early polymerization stage. 4. Preparing bevel at incisal cavosurface margin of V shape cavity increased the Von Mises stress at gingival margin, but decreased at incisal margin. 5. At incisal margin, stress development by bulk curing method was rapid at early stage. Stress development by first increment of incremental curing method was also rapid but lower than that by bulk curing method, however after second increment curing final stress was the same for two placement methods. 6. At gingival margin, stress development by incremental curing method was suddenly rapid at early stage of second increment curing, but final stress was the same for two placement methods.

  • PDF

A STUDY ON THE ENAMEL EROSION BY FERMENTED MILKS (수종 유산균 발효유의 법랑질 침식효과에 대한 연구)

  • Sim, Jeung-Ho;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.4
    • /
    • pp.555-563
    • /
    • 2004
  • The pH of beverages is known to be low and have, therefore, been implicated in the increasing incidence of erosion. Erosion is believed to be the predominant cause of teeth wear in children and young adults, although there will always be a contribution from attrition and abrasion. The aim of the present study was to evaluate the effect of yogurt on the progression of erosive demineralization in human enamel using demineralization model in vitro. In 4 yogurts, available on the market, pH, buffering capacity and the concentrations of calcium, phosphate and fluoride were determined. The buffering effect was determined by titration with NaOH. 50 milliliters of each drink was then titrated with 1M sodium hydroxide, added in 0.5 milliliters increments, until the pH reached about 7. Human deciduous enamel(n=40) samples were divided into four groups and exposed to 80ml of the yogurt for 30,60, 90 and 120min. Enamel surface microhardness(VHN) was examined before and after each exposure. 1. The average PH of fermented milk was 3.77 and this pH value was acidic enough to cause tooth erosion. 2. All of the fermented milks were found to be erosive(p<0.05) 3. The teeth exposed to the fermented milk all showed erosion like lesions and microhardness measurements showed that enamel surface hardness decreased proportionately with increased time of immersion in all tooth specimen groups. 4. After immersion for 30 and 60 minutes, reduction rate of microhardness values was not significantly different between the groups(p>0.05). However, after 90 and 120 minutes, reduction rate of each group was significantly different(p<0.05).

  • PDF

PROPERTIES OF FLUORIDE-RELEASING RESIN COMPOSITE RESTORATIVE MATERIALS (불소방출성 콤포짓트 레진계 수복재의 특성)

  • Kim, Sang-Hoon;Baik, Byeong-Ju;Kim, Jae-Gon;Yang, Yeon-Mi;Park, Jeong-Yeol
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.418-426
    • /
    • 2008
  • The objectives of this study were to examine the properties of fluoride-releasing resin composite restorative materials. Four commercially available compomer materials (Compoglass F: CF, $Dyract^{(R)}$ AP: DA, $Dyract^{(R)}$ flow: DF, F2000: FT) and one fluoride-releasing composite resin ($Tetric^{(R)}$ Ceram: TC) were selected as experimental materials. Rectangular-shaped tensile test specimens were fabricated in a teflon mold giving 5mm in gauge length and 2mm in thickness. Disk-shaped specimens were fabricated in the split teflon mold with diameter of 15mm and thickness of 1mm. After curing for an hour, specimens were immersed in deionized water at $37^{\circ}C{\pm}1^{\circ}C$ for 30 days. All specimens were thermocycled for 10,000 cycles with 15 seconds of dwelling time in each $5^{\circ}C$ and $55^{\circ}C$ water baths. Toothbrush abrasion test was conducted under a load of 1.5 N and the abraded surfaces were examined with surface roughness tester (SV-3000, Mitutoyo Co, Japan) and SEM (JSM-5800, JEOL, Japan). Fluoride recharging was done by toothbrushing for 3 min. using a fluoride toothpaste (Perio Alpine Herb, LG Household & Health Care, Korea). The results obtained were summarized as follows; 1. The highest tensile strength value of 32.3 MPa was observed in TC group and the lowest value of 16.8 MPa was observed in CF group. The tensile strength of TC group was significantly higher than those of CF and DF groups (P<0.05). 2. The lowest Ra value of 0.287 was observed in TC group and the highest value of 1.516 was observed in FT group. The Ra value of FT group was significantly higher than other groups (P<0.05). 3. The abraded surfaces revealed the increase of surface roughness due to the protrusion and missing of filler particles. 4. The release of fluoride of compomers after tooth brushing by Perio Alpine Herb was initially large and then followed by small and continuously. But it remains small and constant in fluoride-releasing composite resin of TC. 5. The highest value of fluoride release after toothbrushing by Perio Alpine Herb was $2.064{\mu}g/cm^2$ in CF group and the lowest value was $0.1119{\mu}g/cm^2$ in TC group. The amount of fluoride release of CF group was significantly higher than other groups (P<0.05).

  • PDF