• 제목/요약/키워드: tomographic images

검색결과 261건 처리시간 0.025초

Positional symmetry of porion and external auditory meatus in facial asymmetry

  • Choi, Ji Wook;Jung, Seo Yeon;Kim, Hak-Jin;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제37권
    • /
    • pp.33.1-33.9
    • /
    • 2015
  • Background: The porion (Po) is used to construct the Frankfort horizontal (FH) plane for cephalometrics, and the external auditory meatus (EAM) is to transfer and mount the dental model with facebow. The classical assumption is that EAM represents Po by the parallel positioning. However, we are sometimes questioning about the possible positional disparity between Po and EAM, when the occlusal cant or facial midline is different from our clinical understandings. The purpose of this study was to evaluate the positional parallelism of Po and EAM in facial asymmetries, and also to investigate their relationship with the maxillary occlusal cant. Methods: The 67 subjects were classified into three groups. Group I had normal subjects with facial symmetry ($1.05{\pm}0.52mm$ of average chin deviation) with minimal occlusal cant (<1.5 mm). Asymmetry group II-A had no maxillary occlusal cant (average $0.60{\pm}0.36$), while asymmetry group II-B had occlusal cant (average $3.72{\pm}1.47$). The distances of bilateral Po, EAM, and mesiobuccal cusp tips of the maxillary first molars (Mx) from the horizontal orbital plane (Orb) and the coronal plane were measured on the three-dimensional computed tomographic images. Their right and left side distance discrepancies were calculated and statistically compared. Results: EAM was located 10.3 mm below and 2.3 mm anterior to Po in group I. The vertical distances from Po to EAM of both sides were significantly different in group II-B (p=0.001), while other groups were not. Interside discrepancy of the vertical distances from EAM to Mx in group II-B also showed the significant differences, as compared with those from Po to Mx and from Orb to Mx. Conclusions: The subjects with facial asymmetry and prominent maxillary occlusal cant tend to have the symmetric position of Po but asymmetric EAM. Some caution or other measures will be helpful for them to be used during the clinical procedures.

모야모야병에서 EDAS 수술효과의 평가를 위한 수술전후 $^{99m}Tc$-HMPAO SPECT의 유용성 (Serial $^{99m}Tc$-HMPAO Brain SPECT for Assessing Perfusion Improvement after EDAS in Moyamoya Patients)

  • 이경한;이상형;여정석;곽철은;정준기;이명철;조병규;고창순
    • 대한핵의학회지
    • /
    • 제28권1호
    • /
    • pp.22-30
    • /
    • 1994
  • Encephalo-duro-arterio-synangiosis (EDAS) is a relatively new surgical procedure for treatment of childhood moyamoya disease. We assessed regional cerebral perfusion in moyamoya patients before (1.3 mo) and after (6.8 mo) EDAS with $^{99m}Tc$-HMPAO brain SPECT. A total of 21 EDAS operations in 17 moyamoya patients was included. Preoperative CT or MRI showed cerebral infarction in 14 patients and carotid angiography showed Suzuki grade I to V stenosis in 6%, 9%, 62%, 12% and 12% of the hemispheres respectively. Preoperative SPECT showed regional hypoperfusion in all patients, bilateral frontal and temporal lobes being the most frequently involved site. $4{\times}4$ pixel sized ROIs were applied on the frontotemporal cortex in 3 slice averaged transverse tomographic images. An index of regional perfusion was measured as: PI (%)=average F-T activity/average cerebellar activity${\times}100$ Pre-EDAS ipsilateral PI ranged from 23.7 to 98.4% (mean: $74.3{\pm}17%$) and increased significantly after operation ($81.4{\pm}17%$, p<0.001). Individual post-EDAS PI improved in 15/21 cases, showed no significant change in 5 and was slightly aggravated in 1. The amount of clinical improvement (${\Delta}CI$) was graded with a scale of 0 to 4 based on frequency and severity of TIA attacks. When patients were grouped according to pre-EDAS PI, group II (PI 70-89) showed a significantly higher ${\Delta}CI$ (3.3) compared to group I (PI< 70, 1.57) or group III (PI >90, 0.5) (P< 0.001). The amount of perfusion improvement (${\Delta}PI$) showed significant correlation with ${\Delta}CI$ (r=0.42, p=0.04). ${\Delta}PI$ did not, however, correlate with the amount of neovascularization assessed angiographically in 8 patients. Serial HMPAO SPECT is an useful noninvasive study for assessing perfusion improvement after EDAS in childhood moyamoya patients.

  • PDF

측두하악관절 주변인대 질환의 초음파영상 (Ultrasounds Image on the Disorders of the Ligaments Surrounding Temporomandibular Joints)

  • 홍수민;임영관;김병국
    • Journal of Oral Medicine and Pain
    • /
    • 제33권4호
    • /
    • pp.387-394
    • /
    • 2008
  • 목적 : 측두하악장애 환자에서 고가의 자기공명영상 진단을 대신하여 상대적으로 경제적인 진단방법으로 고해상도 초음파 영상을 도입하는데 있어서 그 정확성과 유용성을 확인하고자 하였다. 방법 : 측두하악장애의 임상적 증상 중 과두걸림, crepitation과 함께 통증을 호소하는 20명의 환자를 대상으로 하였다. 고해상도 초음파 촬영을 시행하였고, 고해상도를 가진 초음파촬영시의 결과를 비교하기 위하여, 통상적인 방사선 사진인 측두하악관절의 횡두개 촬영을 Accurad X-200으로, 그리고 Dental CT를 촬영하였으며, 이를 임상소견과 더불어 비교항목으로 선택하였다. 고해상도 초음파의 진단학적 가지 평가를 위하여 통계학적으로 감수성, 특이성, 양성예상치, 음성예상치 및 정확도를 계산하였다. 결과 : 고해상도의 초음파 영상은 골관절염성 변화를 진단하는데 67.5%의 정확도를 보였으며, 관절원판의 위치변화를 진단하는데 92.5%를 보였으나, 관절 주변조직인 관절낭, 관절원판 후조직 그리고 주변 인대의 이상을 측정하는데 있어서 정확도가 55%를 나타내었다. 결론 : 향후 초음파 영상을 얻기 위한 적절한 기기의 발전과 고주파수의 transducer 등이 개발되고 시술자의 훈련과 경험이 쌓이게 되면 매우 우수한 그리고 비침습적이고 접근이 용이하며 경제적인 진단학적인 검사방법으로서 일반적인 도입이 가능할 것으로 사료된다.

X선 토모그램의 Smoothing 효과가 암석의 물성 예측에 미치는 영향 분석 (Smoothing Effect in X-ray Microtomogram and Its Influence on the Physical Property Estimation of Rocks)

  • 이민희;김영석
    • 지구물리와물리탐사
    • /
    • 제12권4호
    • /
    • pp.347-354
    • /
    • 2009
  • 암석의 물성을 정확히 예측하기 위해서는 물성에 일차적인 효과를 미치는 공극구조에 대한 이해가 매우 중요하며, 정확한 공극구조와 물성시뮬레이션을 이용한 다양한 물성예측 및 변화양상의 정량적 상관관계는 많은 지구물리분야에 응용할 수 있다. 최근 비파괴 구조해석방법, 특히 X선 토모그래피를 이용한 고분해능 스캔 등이 상용화되고 컴퓨터의 성능이 향상됨에 따라 실제의 공극구조를 이용하여 투수율을 예측하는 연구가 시도되고 있다. 본 연구에서는 이러한 연구를 투수율뿐만 아니라 속도와 전기전도도의 영역으로 확장하려는 시도를 하였다. 하지만 토모그래피 방법에서 발생하는 smoothing 효과에 의해 공극구조가 왜곡되고 계산된 물성에 오차가 발생하여, 영상처리기법(sharpening filtering 및 인공신경망 분류법)을 사용하여 smoothing 효과를 제거하는 방법을 시도하였다. 그 결과 가시적으로 향상된 공극구조를 얻을 수 있었고, 투수율 및 전기전도도의 계산값도 이론적 모델링과 유사한 정도의 정확도를 얻을 수 있었다. 하지만 속도의 경우에는 smoothing 효과의 제거에도 불구하고 오차도 상대적으로 크고 향상정도도 매우 미미하였다. 박편과 토모그래피에서 얻어진 공극구조의 비교 연구를 통하여 본 연구에서 사용된 사암의 경우에는 토모그래피에서 얻어진 해상도가 너무 낮은 것을 확인할 수 있었으며, 이러한 이유로 smoothing 효과가 제거되어도 속도예측의 향상은 그리 크지 않은 것으로 나타났다. 결론적으로 본 연구에서 제시된 방법은 토모그램의 smoothing 효과를 효율적으로 제거하였으며 이는 토모그래피방법으로 공극구조를 획득할 때 유용하게 사용될 것으로 기대된다. 또한 속도예측의 경우 토모그램의 해상도가 매우 중요한 인자로 판명되었으며 투수율 예측에 일반적으로 사용되는 해상도보다 최소 세 배 이상의 높은 해상도가 요구되는 것으로 파악되었다.

CT 영상을 이용한 악골 골수염의 경조직 변화에 관한 연구 (Study on the hard tissue changes in osteomyelitis of the jaws using CT image)

  • 안창현;최보람;허경회;이원진;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제39권3호
    • /
    • pp.163-168
    • /
    • 2009
  • Purpose : To assess the clinical findings and hard tissue changes of osteomyelitis of the jaws using computed tomographic (CT) image analysis. Materials and Methods : We reviewed and interpreted the CT images of 163 patients (64 males and 99 females, age range from 10 to 87 years) who visited the Seoul National University Dental Hospital from April 23, 2006 to December 31, 2008 and were diagnosed as osteomyelitis of the jaws through clinical, radiologic, and histopathologic examination. Each CT findings was investigated for frequency, correlation with age and gender. Results : Of the 163 patients, 31 (19.0%) were affected on the maxilla, 135 (82.8%) were affected on the mandible, and 3 (1.8%) were affected on the both jaws simultaneously. The mean age of the patients who were affected on the maxilla was 61.0 years and that of the patients who were affected on the mandible was 56.2 years. On the maxilla, the most frequent site of disease was the posterior area (83.9%) and on the mandible, mandibular body (83.0%), followed by angle (48.1%), ramus (38.5%), condyle (13.3%), incisal area (9.6%), and coronoid process (3.0%). Among the 31 maxillary osteomyelitis, defect in the trabecular bone was observed in 28 (90.3%), osteosclerosis 20 (64.5%), defect in the cortical bone 27 (87.1%), sequestrum 17 (54.8%), and periosteal reaction 2 (6.5%). Among the 135 mandibular osteomyelitis, defect in the trabecular bone was observed in 100 (74.1%), osteosclerosis 104 (77.0%), defect in the cortical bone 116 (85.9%), sequestrum 36 (26.7%), and periosteal reaction 67 (49.6%). Conclusion : Of our cases, the maxillary osteomyelitis was visibly observed more frequently in females than males. The incidence is the highest in seventies (28.8%) and the lowest in teens (3.1%). The osteomyelitis of the jaws was observed more frequently in males than females before the age of 50, and observed more frequently in females after the age of 50. The most noticeable point was that the sequestrum was observed more often on maxillary osteomyelitis and the periosteal reaction was observed more often on mandibular osteomyelitis.

  • PDF

상악동 중격;임플란트 수술 계획시 파노라마와 치과용 전산화 단충촬영 분석 (Maxillary sinus septum;panoramic radiographic and dental computed tomographic analyses in the planning of implant surgery)

  • 소현자;정동근;권진희;유소현;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제36권1호
    • /
    • pp.147-154
    • /
    • 2006
  • Surgical intervention in the posterior maxillary region requires detailed knowledge of maxillary sinus anatomy and the possible anatomical variations. This study evaluated the incidence, location of maxillary sinus septa by using radiographic (panoramic radiography and computed tomography) findings and comparison of panoramic radography with CT in antral anatomical variation. This study was based on data from 70 sinuses in partial dentate maxilla. The sample consisted of 61 patients(25 women and 36 men, with ages ranging between 19 and 77 years and a mean age of $49.4{\pm}11.3$ years) who were being treatment-planned to receive implant-supported restorations. First, the panoramic images were examined for the presence of antral septa by radiologist and examiner who don't know about CT findings. And incidence of antral septa was evaluated using an axial plane of CT image. The incidence of septa was compared between panoramic radiography and CT. The accuracy of the incidence was compared between radiologists and dentists. A total of 20 septa were found in 70 sinuses on CT image and the prevalence of one or more septa per sinus was found to be 28.6%. The assumed incidence of septa on panoramic radiography was $27.6%{\pm}2.2%$ in radiologist and $31.9%{\pm}5.8%$ in dentists. Erroneous diagnosis rate was 11.42% in radiologist and 15.96% in dentists. 40% of antral septa were located in the anterior(premolar) region, 30% of septa were located in the middle(first molar) and posterior(second molar) region separately. Prior to implant placement, it seems appropriate to consider panoramic radiography as a standard radiographic examination and periapical radiographs may be used to complete the findings in regions not sharply depicted in the panoramic radiograph. And cross-sectional imaging should be used in sites with severe bone loss and close proximity of the maxillary sinus.

전기비저항 토모그래피와 시추공 레이다 탐사의 원리 및 응용 (Principles and application of DC resistivity tomography and borehole radar survey.)

  • 김정호;이명종;조성준;송윤호;정승환
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 1999년도 제2회 학술발표회
    • /
    • pp.92-116
    • /
    • 1999
  • 전기, 전자 토모그래피는 전기적인 물성을 이용하여 지하의 고분해능 영상을 획득하는 방법이며 주파수에 의하여 전기비저항, 전자탐사, 레이다 토모그래피로 나뉘어진다. 이들 중 전기비저항, 레이다 토모그래피는 최근 들어 국내에서도 특히 지반조사 분야에서 활발하게 이용되기 시작하고 있다 본 논문에서는, 전기, 전자 토모그래피 법 중 국내에서 사용되는 전기비저항 토모그래피 및 레이다 토모그래피를 포함한 시추공을 이용한 레이다 탐사의 원리 및 적용에 대하여 국내의 탐사 사례를 중심으로 논하였다. 특히 시추공을 이용한 레이다 탐사의 방법론적인 접근에 있어서는, 방향탐지 안테나를 이용한 레이다 반사법 탐사법과 이방성 토모그래피 문제가 석산 탐사 및 지반조사 사례를 이용하여 논의되었다 한편 전기비저항 토모그래피에서는 각종의 전극 배열의 장단점이 논의되었으며, 전기전도도가 높은 시추공 공내수 내에 전극이 위치하기 때문에 발생하는 시추공 효과에 대하여 설명하였다. 대부분의 사례들은 알려져 있는 지질 정보, 시추코아 검층자료, 텔레뷰어 등의 자료와 비교하여 논의하였다.

  • PDF

시뮬레이션된 성인 남성 인체모형 팬텀을 이용한 전산화단층촬영 에서의 노이즈 제거를 위한 Median Modified Wiener 필터 (Median Modified Wiener Filter for Noise Reduction in Computed Tomographic Image using Simulated Male Adult Human Phantom)

  • 주성욱;안병헌;강성현;이영진
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.21-28
    • /
    • 2021
  • 전산화단층촬영장치 (computed tomography, CT)는 다른 방사선 촬영 장치와 비교하면 피폭이 많다는 문제점이 있다. 이러한 피폭을 감소하기 위하여 저선량 촬영을 하게 되면 영상에 잡음이 증가하게 된다. 이를 보완하기 위해 환자의 피폭선량은 감소시키면서 영상의 화질을 향상하는 다양한 잡음 제거 알고리즘이 개발되었으며, 그 중 우수한 시간 분해능을 가진 CT 장치에 효과적으로 적용할 수 있는 median modified Wiener filter (MMWF) 알고리즘이 제시되었다. 본 연구의 목적은 MMWF 알고리즘의 마스크 크기를 최적화하고, 기존의 알고리즘들에 대한 MMWF 알고리즘의 잡음 제거의 우수성을 보는 것이다. MATLAB 프로그램을 이용하여 획득한 Gaussian 잡음이 부가된 MASH 팬텀 복부 영상들로부터 각각의 마스크 크기가 설정된 MMWF 알고리즘을 적용한 후 root mean square error (RMSE), peak signal-to-noise ratio (PSNR), coefficient correlation (CC) 그리고 universal image quality index (UQI) 값을 비교하였다. 그 결과 5 × 5 마스크 크기에서 RMSE 값이 가장 낮고, PSNR, CC, UQI 값이 가장 높았다는 것을 확인할 수 있었다. 또한, 최적화된 마스크 크기로 Gaussian 필터, median 필터, Wiener 필터에 대한 MMWF의 RMSE, PSNR, CC, UQI 값을 비교하였으며 그 결과 MMWF 알고리즘에서 가장 개선된 RMSE, PSNR, CC, UQI 값을 얻을 수 있었다.

Cone-beam computed tomographic evaluation of mandibular incisor alveolar bone changes for the intrusion arch technique: A retrospective cohort research

  • Lin Lu;Jiaping Si;Zhikang Wang;Xiaoyan Chen
    • 대한치과교정학회지
    • /
    • 제54권2호
    • /
    • pp.79-88
    • /
    • 2024
  • Objective: Alveolar bone loss is a common adverse effect of intrusion treatment. Mandibular incisors are prone to dehiscence and fenestrations as they suffer from thinner alveolar bone thickness. Methods: Thirty skeletal class II patients treated with mandibular intrusion arch therapy were included in this study. Lateral cephalograms and cone-beam computed tomography images were taken before treatment (T1) and immediately after intrusion arch removal (T2) to evaluate the tooth displacement and the alveolar bone changes. Pearson's and Spearman's correlation was used to identify risk factors of alveolar bone loss during the intrusion treatment. Results: Deep overbite was successfully corrected (P < 0.05), accompanied by mandibular incisor proclination (P < 0.05). There were no statistically significant change in the true incisor intrusion (P > 0.05). The labial and lingual vertical alveolar bone levels showed a significant decrease (P < 0.05). The alveolar bone is thinning in the labial crestal area and lingual apical area (P < 0.05); accompanied by thickening in the labial apical area (P < 0.05). Proclined incisors, non-extraction treatment, and increased A point-nasion-B point (ANB) degree were positively correlated with alveolar bone loss. Conclusions: While the mandibular intrusion arch effectively corrected the deep overbite, it did cause some unwanted incisor labial tipping/flaring. During the intrusion treatment, the alveolar bone underwent corresponding changes, which was thinning in the labial crestal area and thickening in the labial apical area vice versa. And increased axis change of incisors, non-extraction treatment, and increased ANB were identified as risk factors for alveolar bone loss in patients with mandibular intrusion therapy.

감마카메라에서의 팬텀 내 선원 위치 변화에 따른 산란 영향 평가 (The Evaluation of Scattering Effects for Various Source Locations within a Phantom in Gamma Camera)

  • 유아람;이영섭;김진수;김경민;천기정;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.216-224
    • /
    • 2009
  • $^{99m}Tc$은 핵의학 영상 획득 물리적 특성이 우수하지만 유기화 작용이 일어나지 않아 갑상선 호르몬의 합성능력이 없는 결절을 진단하는데 제한을 받는다. 이와는 달리 $^{131}I$은 유기화 작용으로 인하여 갑상선의 기능을 평가하는데 활용됨은 물론 높은 에너지의 베타선과 감마선을 방출함으로써 암의 치료에도 널리 사용되고 있는 방사선 핵종이다. 그러나 $^{131}I$은 단일에너지의 감마선을 방출하는 $^{99m}Tc$ 등과는 달리, 다양한 에너지의 감마선을 방출함으로써 핵의학 영상의 정량화가 어려운 단점이 있으며, 특히 고에너지 영역의 감마선에 의한 격벽투과와 산란선은 핵의학 진단영상에 악영향을 미치게 되는 단점이 있다. 본 연구에서는 팬텀 내에서 선원의 위치 변화에 따른 산란의 영향을 알아보기 위해 GATE (Geant4 Application for Tomographic Emission) 시뮬레이션 도구로 dual-head 감마카메라(ECAM), PMMA 팬텀(RADICAL, USA), 점선원 0.1 mCi를 사용하여 모사하였다. 팬텀 내에서 $^{131}I$ 점선원을 X축, Y축으로 위치를 변화시키며 영상을 획득하였다. 또 산란 매질의 유무에 따른 영향을 확인하기 위해 같은 위치에서 점선원이 팬텀 안에 있을 때와 공기 중에 있을 때를 비교 하였다. 저에너지 선원과 비교를 위해 같은 방법으로 $^{99m}Tc$으로도 시뮬레이션 하였다. 또한 시뮬레이션과 똑같은 환경에서 측정 실험을 통해 시뮬레이션의 타당성을 검증 하였다. 이 연구에서는 한 팬텀 내에서도 위치 변화에 따라 산란의 영향이 달라진다는 것을 시뮬레이션을 통해 확인하였다. 이러한 분포 변화는 시뮬레이션과 측정 실험 모두에서 동일한 경향을 나타내었으므로 시뮬레이션이 타당함을 확인할 수 있었다. 시뮬레이션을 이용하면 X축, Y축 위치 변화만 아닌 다양한 경우에 대해서도 위치 변화에 따른 산란 영향의 예상이 가능할 것이며 나아가 산란 보정 연구의 기초 자료로 사용될 것이라 생각한다.

  • PDF