Maxillary sinus septum;panoramic radiographic and dental computed tomographic analyses in the planning of implant surgery

상악동 중격;임플란트 수술 계획시 파노라마와 치과용 전산화 단충촬영 분석

  • So, Hyun-Ja (Department of Periodontology, College of Dentistry, Chonbuk National University) ;
  • Jeong, Dong-Keun (Department of Periodontology, College of Dentistry, Chonbuk National University) ;
  • Kwon, Jin-Hee (Department of Periodontology, College of Dentistry, Chonbuk National University) ;
  • Ryu, So-Hyun (Department of Periodontology, College of Dentistry, Chonbuk National University) ;
  • Kim, Hyung-Seop (Department of Periodontology and Research Institute of Oral Bio-Science, College of Dentistry, Chonbuk National University)
  • 소현자 (전북대학교 치과대학 치주과학교실) ;
  • 정동근 (전북대학교 치과대학 치주과학교실) ;
  • 권진희 (전북대학교 치과대학 치주과학교실) ;
  • 유소현 (전북대학교 치과대학 치주과학교실) ;
  • 김형섭 (전북대학교 치과대학 치주과학교실, 전북대학교 구강생체과학 연구소)
  • Published : 2006.03.30

Abstract

Surgical intervention in the posterior maxillary region requires detailed knowledge of maxillary sinus anatomy and the possible anatomical variations. This study evaluated the incidence, location of maxillary sinus septa by using radiographic (panoramic radiography and computed tomography) findings and comparison of panoramic radography with CT in antral anatomical variation. This study was based on data from 70 sinuses in partial dentate maxilla. The sample consisted of 61 patients(25 women and 36 men, with ages ranging between 19 and 77 years and a mean age of $49.4{\pm}11.3$ years) who were being treatment-planned to receive implant-supported restorations. First, the panoramic images were examined for the presence of antral septa by radiologist and examiner who don't know about CT findings. And incidence of antral septa was evaluated using an axial plane of CT image. The incidence of septa was compared between panoramic radiography and CT. The accuracy of the incidence was compared between radiologists and dentists. A total of 20 septa were found in 70 sinuses on CT image and the prevalence of one or more septa per sinus was found to be 28.6%. The assumed incidence of septa on panoramic radiography was $27.6%{\pm}2.2%$ in radiologist and $31.9%{\pm}5.8%$ in dentists. Erroneous diagnosis rate was 11.42% in radiologist and 15.96% in dentists. 40% of antral septa were located in the anterior(premolar) region, 30% of septa were located in the middle(first molar) and posterior(second molar) region separately. Prior to implant placement, it seems appropriate to consider panoramic radiography as a standard radiographic examination and periapical radiographs may be used to complete the findings in regions not sharply depicted in the panoramic radiograph. And cross-sectional imaging should be used in sites with severe bone loss and close proximity of the maxillary sinus.

Keywords

References

  1. Chanavaz M. Maxillary sinus: Anatomy, physiology, surgery, and bone grafting related to implantology. -Eleven years of surgical exprerience (1970-1990) J Oral Implantol 1990;16:199-209
  2. Kaufman E. Maxillary sinus elevation surgery. An overview J Esthet Restor Dent 2003;15:272-283 https://doi.org/10.1111/j.1708-8240.2003.tb00298.x
  3. Sailer HF. A new method of inseting endosseous implants in totally atrophic maxillae. J Cranio-Max Fac Surg 1989;17:299-305 https://doi.org/10.1016/S1010-5182(89)80057-5
  4. Smiler DG, Johnson PW, Lozada JL, Misch C, Rosenlicht JL, Tatum H, Wagner JR. Sinus lift grafts and endosseous implants: Treatment of the atrophic posterior maxilla. Dental Clin North America 1992;36:151-186
  5. Tatum H. Maxillary sinus implant reconstructions. Dent Clin North Am 1986;30:207-229
  6. van den Bergh, ten Bruggenkate, JM Disch, Tuinzing DB. Anatomical aspects of sinus floor elevations. Clin Oral Impl Res 2000;11:256-265 https://doi.org/10.1034/j.1600-0501.2000.011003256.x
  7. Betts J, Miloro M. Modification of the sinus lift procedure for septa in the maxillary antrum. J Oral Maxillofac Surg 1994;52:332-333 https://doi.org/10.1016/0278-2391(94)90313-1
  8. ten Bruggenkate & van den Bergh Maxillary sinus floor elevation: a valuable pre-prosthetic procedure. Periodontology 2000 1998; 17: 176-182 https://doi.org/10.1111/j.1600-0757.1998.tb00133.x
  9. Krennmair G., Ulm C., Lugmayr H. Maxillary sinus septa: incidence, morphology and clinical implications. J Cranio-Maxillofacial Surg 1997; 25:261-265 https://doi.org/10.1016/S1010-5182(97)80063-7
  10. Ulm W.,Solar P , Krennmair G, Matejka M, Watzek G. Incidence and suggested surgical management of septa in sinus-lift procedures. Int J Oral Maxillofac Implants 1995;10:462-465
  11. Andresson L. & Kurol M. CT scan prior to installation of osseointegrated implants in the maxilla. Int J Oral Maxillofac Surg 1987;16:50-55 https://doi.org/10.1016/S0901-5027(87)80030-9
  12. Andresson JE & Svartz K. CT-scanning in the preoperative planning of osseointegrated implants in the maxilla. Int J. Oral Maxillofac Surg 1988;17:33-35 https://doi.org/10.1016/S0901-5027(88)80226-1
  13. Sakakura CE, Morais JAND, Loffredo LCM, Scaf G A survey of radiographic prescription in dental implant assessment. Dentomaxillofacial Radiology 2003;32:397-400 https://doi.org/10.1259/dmfr/20681066
  14. Dula K, Mini R, van der Stelt, Buser D. The radiographic assessment of implant patients. Decision-making criteria Int J. Oral .Maxillofac Implants 2001;16:80-89
  15. Tal H. & Moses O. A comparison of panoramic radiography with computed tomography in the planning of implant surgery. Dentomaxillofacial Radiology 1991;20:40-42 https://doi.org/10.1259/dmfr.20.1.1884852
  16. Tyndall A., Brooks L., Hill C, Arbor A. Selection criteria for dental implant site imaging. A position paper of the American Academy of Oral and Maxillofacial Radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2000;89: 630-637 https://doi.org/10.1067/moe.2000.106336
  17. Krennmair G., Ulm C., Lugmayr H., Solar P. The incidence, location, and height of maxillary sinus septa in the edentulous and dentate maxilla. J Oral Maxillofac Surg 1999;57:667-671 https://doi.org/10.1016/S0278-2391(99)90427-5
  18. Clark DE, Danforth RA, Barnes RW, Burtch ML Radiation absorbed from dental implant radiography: A comparison of linear tomography, CT scan, and panoramic and intra-oral techniques. J Oral Implantol 1990;16:156-164
  19. Ekestubbe A, Grondahl HG, Molander B. Quality of digital pre-implant tomography: comparison of film-screen images with storage phosphor images at normal and low dose. Dentomaxillofacial Radiol 2003;32:322-326 https://doi.org/10.1259/dmfr/50054523
  20. Lecomber AR, Yoneyama Y, Lovelock DJ, T Hosoi, AM Adams Comparison of patient dose from imaging protocols for dental implant planning using conventional radiography and computed tomography. Dentomaxillofacial Radiol 2001;30:255-259 https://doi.org/10.1038/sj.dmfr.4600627
  21. Schwarz MS, Rothman SLG, Chafetz N, Rhodes M. Computed tomography in dental implantation surgery. Dental Clinics of North America 1989;33: 555-597
  22. Schwarz MS, Rothman SLG, Rhodes ML, Chafetz N Computed tomography: Part II. Preoperative assessment of the maxilla for endosseous implant surgery. Int J. Oral & Maxillofac Implants 1987;2:143-148
  23. Velasquez-Plata D, Hovey LR, Peach CC, Alder ME Maxillary sinus septa: A 3-dimensional computerized tomographic scan analysis. Int J Oral Maxillofac Implants 2002;17:854-860
  24. 오희균, 유선열 상악동 중격에 대한 임상해부학적 연구 대한구강악안면외과학회지 1998;24:208-212
  25. Haidar Z. Diagnostic limitations of orthopantomography with lesions of the antrum. Oral Surg. 1978;46:449-453 https://doi.org/10.1016/0030-4220(78)90413-9
  26. White C., Pharoah J. Oral Radiology: Principles and interpretation -fifth edition
  27. Perez CA, Farman AG, Louisville Diagnostic radiology of maxillary sinus defects. Oral Surg Oral Med Oral Pathol 1988; 66: 507-512 https://doi.org/10.1016/0030-4220(88)90279-4