무성방전내에서 톨루엔 제거에 미치는 운전변수의 영향 (Effects of Operating Parameters on Toluene Removal in Dielectric Barrier Discharge Process)

  • 정재우;이용환;박경렬
    • 한국대기환경학회지
    • /
    • 제18권3호
    • /
    • pp.173-182
    • /
    • 2002
  • We investigated the effects of operating variables, such as electrical. reactor and gas parameters on toluene removal and discharge property in the dielectric barrier discharge (DBD) process. The toluene removal was initiated with the energy transfer to the reactor by loading of voltages higher than the discharge onset value. The energy transfer and toluene removal increased with the applied voltage. Higher removal rate was observed with smooth surface electrode despite of lower energy transfer compared with the coarse electrode, because more uniform discharge can be obtained on smooth surface state. The decrease of dielectric material thickness enhanced the removal efficiency by increasing the discharge potential. The toluene removal efficiency decreased with the increase of the inlet concentration. The increase of gas retention time enhanced the removal efficiency by the increase of energy density. The oxygen and humidity contents seem to exert significant influences on the toluene removal by dominating the generation of electrons, ions, and radicals which are key factors in the removal mechanism.

Bio필터를 이용한 VOC 가스 중 Toluene 제거율과 필터특성 연구 (A Study on Toluene Removal of VOC and Characteristics of Material Using Biofilter)

  • 강신묵;하상안
    • 환경위생공학
    • /
    • 제13권2호
    • /
    • pp.88-94
    • /
    • 1998
  • This study was investigated the application of biofiltration using cometabolic process to remediate gaseous toluene that are highly recalcitrant to adsorption, absorption and biodegradation. The investigation was conducted using specially built steel columns packed with granular activated carbon for removal of toluene and G.A.C was also coated with Pseudomonas putida microorganisms by addition of KH$_{2}$PO$_{4}$. The biofilter unit was operated in the condition of dry and 27.5% moisture content at gas loading rate of 12.5 l/min. Gaseous toluene taken from tedlar bag was analyzed by the use of G.C. equipped with F.I.D. detector. The removal efficiency of gaseous toluene was 85% at average inlet concentration of 970 ppm during dry operating condition. For gaseous toluene, 91% removal efficient was obtained at the filter material with moisture content and 97% removal efficiency was obtained with Pseudomonas putida microorganisms at gas loading rate of 12.5 l/min.

  • PDF

연면방전 플라즈마를 이용한 톨루엔 처리에 관한 연구 (Toluene Removal Using Surface Discharge Induced Plasma Chemical Process)

  • 부문자;봉춘근;김신도
    • 한국대기환경학회지
    • /
    • 제13권4호
    • /
    • pp.297-305
    • /
    • 1997
  • The experimental study by use of SPCP was fulfilled to remove toluene emitted from various industrial processes. First of all, discharge characteristic was experimented as the change of applied voltage and frequency. Then toluene removal characteristic was tested with the analysis of by-products. As a result, optimum electrical discharge condition was from 20.0 kHz to 25.0 kHz of frequency and from 3.5 kV to 4.0 kV of voltage range. The variation of applied voltage had a more important effect on the removal characteristic of toluene than the frequency variation. The toluene removal efficiency was proportioned to ozone concentration and retention time on discharge plate. It was dropped as increase of toluene concentration, but total treated volume of tolene per power consumption was high. The decomposed toluene was transformed to $CO, CO_2$ and particulates, and the rate of transformation to particulates was higher than CO and $CO_2$ at high toluene concentration. Particulates were increased from 0.017 $\mum$ to 0.3 $\mum$ range of size distribution.

  • PDF

Bio 필터를 이용한 Toluene 제거에서 미생물분해에 관한 연구 (A Study on Microbial Degradation for Removal of Toluene Vapour by Biofilter)

  • 하상안;강신묵
    • 환경위생공학
    • /
    • 제14권1호
    • /
    • pp.24-30
    • /
    • 1999
  • A biological filter for treatment of toluene among volatile organic compounds was studied. The investigation was conducted using specially built stainless steel columns packed with granular activated carbon and cold for removal of toluene. The G.A. and mold as filter material was also coated with Pseudomonas putida microorganisms.The biofilter unit was operated in the condition of moisture content vairation at gas loading rate of 12.5 l/min. Gaseous toluene taken from tedlar bag was analyzed by the use of G.C equipped with F.I.d detector. The removal efficiency of gaseous toluene was 95% at average inlet concentration of 950 ppm during bio-degradation operating condition. Effective removal efficiency was obtained with moisture content 27.5% at activated carbon and 32% at mold in this study. The effective operating condition were obtained with pH 6-8, temperature 28-42℃ for microbial degradation at gas loading rate of 12.5 l/min in packed material.

  • PDF

Simultaneous Removal of H2S, NH3 and Toluene in a Biofilter Packed with Zeocarbon Carrier

  • Park, Byoung-Gi;Shin, Won-Sik;Jeong, Yong-Shik;Chung, Jong-Shik
    • 한국환경과학회지
    • /
    • 제17권1호
    • /
    • pp.7-17
    • /
    • 2008
  • Simultaneous removal of $NH_3,\;H_2S$ and toluene in a contaminated air stream was investigated over 185 days in a biofilter packed with Zeocarbon granule as microbial support. In this study, multi-microorganisms including Nitrosomonas and Nitrobacter for nitrogen removal, Thiobacillus thioparus (ATCC 23645) for $H_2S$ removal, and Pseudomonas aeruginosa (ATCC 15692), Pseudomonas putida (ATCC 17484) and Pseudomonas putida (ATCC 23973) for toluene removal were used simultaneously. The empty bed residence time (EBRT) was 40-120 seconds and the feed (inlet) concentrations of $NH_3,\;H_2S$ and toluene were 0.02-0.11, 0.05-0.23 and 0.15-0.21 ppmv, respectively. The observed removal efficiency was 85%-99% for $NH_3$, 100% for $H_2S$, and 20-90% for toluene, respectively. The maximum elimination capacities were 9.3, 20.6 and $17g/m^3/hr\;for\;NH_3,\;H_2S$ and toluene, respectively. The results of kinetic model analysis showed that there were no particular evidences of interactions or inhibitions among the microorganisms, and that the three bio degradation reactions took place independently within a finite area of biofilm developed on the surface of the Zeocarbon carrier.

다공성 세라믹 Biofilter를 이용한 Toluene 가스 제거 (Removal of Toluene Vapor by Porous Ceramic Biofilter)

  • 임재신;구자공;박상진
    • 한국대기환경학회지
    • /
    • 제14권6호
    • /
    • pp.599-606
    • /
    • 1998
  • Removal of toluene vapor from airstreams was studied in a biological reactor known as a biofilter. The biofilter was packed porous ceramic inoculated with thickened activated sludge (MLVSS 17,683 mg/L). The lab-scale biofilter was operated for 42 days under various experimental conditions including inlet toluene concentrations and flow rates of the contaminated air streams. Removal efficiency reached up 96.6% after 4 days from start up. Nutrient limitation was proposed as a reason for the decrease in biofilter performence. Biofilter performance decreased substantially, coincident with the buildup of back pressure due to accumulation of excess VSS within the medium bed. Practically, the bed needs to be backwashed when the overall pressure drop is greater than 460.6 Pa at SV (Space Velocity) 100 h-1. Periodic backwashing of the biofilter was necessary for removing excess biomass and attaining stable long -term high removal efficiency The removal efficiency of toluene in the biofilter decreased as the gas velocity and toluene concentration in the inlet gas increased. The maximum elimination capacity of ceramic biofilter could reach up to 444.85 g/m3. hr. When the loading of toluene exceed this critical value, substrate inhibition occurred.

  • PDF

중공사막을 적용한 2단 멤브레인 하이브리드 반응기에 의한 톨루엔 제거 (Removal of toluene using the 2-stage hollow fiber membrane-hybrid reactor)

  • 김진성;구소희;김태형;이명주;황선진
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.287-293
    • /
    • 2010
  • In this study, the toluene gas in VOCs was removed using bioreactor which applied with hollow fiber membrane and Pseudomonas sp. TDB-4. The EBRT of each reactor are controlled 60 sec(R-1) and 30 sec(R-2) and inlet tolune concentration of both R-1 and R-2 is controlled from 25ppm to 500 ppm. Up to 500 ppm of toluene concentration, the toluene removal efficiency of R-1 and R-2 are 92% and 81%, and theirs removal capacities are about 100 g/$m^3$/hr and 180 g/$m^3$/hr, respectively. In addition, according to this study, toluene removal efficiencies at the hollow fiber are approximately 70%(60 sec) and 45%(30sec).

초음파 발생 미스트를 이용한 TiO2 광촉매 시스템에서의 가스상 톨루엔 제거 (Removal of Gaseous Toluene Using a TiO2 Photocatalytic System with Mist Generated by Ultrasonic Atomization)

  • 최민석;한세현;장성찬;정용원
    • 한국대기환경학회지
    • /
    • 제25권3호
    • /
    • pp.211-218
    • /
    • 2009
  • Feasibility study of using $Ti0_2$ mist generated by ultrasonic atomization for photocatalytic degradation of gaseous toluene was attempted in this study. For this, the photocatalytic reactor consisting of mist generator and photo-reactor was designed. Most of experimental results showed that steady state reached about 30 minutes after the start of experiments. The effects of $Ti0_2$ concentration, toluene concentration, and UV wavelength on toluene removal ratio were investigated. It was found that the highest removal efficiency was obtained when $Ti0_2$ concentration was 0.6 g/L in slurry. At this condition, it was found that the toluene removal efficiency increased as toluene concentration in feed decreased. In order to investigate the effect of UV wavelength, experiments were carried out using three UV lamps with different UV wavelength. The results showed that the highest removal efficiency was achieved when the lamp with the shortest wavelength were employed.

소각비산재로 제조한 광촉매 흡착제의 벤젠과 톨루엔 제거특성 (Removal of Benzene and Toluene by Photo-catalyst Adsorbent Prepared from MSWI Fly Ash)

  • 최소영;심영숙;이우근
    • 한국대기환경학회지
    • /
    • 제21권4호
    • /
    • pp.431-438
    • /
    • 2005
  • In order to apply the photocatalytic decomposition of aromatic VOCs, adsorbent prepared from MSWI fly ash was coated by $TiO_2$ solution to endow with photo-catalytic function. The effects of coating number, existence of light source and the type of $TiO_2$ solution used for coating were examined. Adsorbent coated with amorphous $TiO_2$ solution showed higher adsorptivity than adsorbent coated with crystal $TiO_2$ solution. Without light source, breakthrough curve of photo -catalyst absorbent for VOCs removal was similar to that of absorbent made from MSWI fly ash. On the other hand, breakthrough time was enlarged with light source and total removal efficiency of benzene and toluene was also increased. It can be explained as photo-decomposition effect of $TiO_2$ photo-catalyst. Total removal efficiency of benzene and toluene was increased according to the increase of coating number with light source. It was due to the effect of adsorption and photo reaction of photo-catalytic adsorbent. But total removal efficiency of benzene was lower than that of toluene. Because benzene was removed more effectively than toluene by adsorption, but photo - decomposition effect oi toluene was more high than benzene.

복합열산화(Hybrid Thermal Oxidation) 시스템을 이용한 MEK(Methyl ethyl ketone)와 Toluene 제거 평가 (Evaluation of Hybrid Thermal Oxidation(HTO) System for Removal of MEK(Methyl ethyl ketone) and Toluene)

  • 장두훈;배우근;김문일;김경태
    • 한국지반환경공학회 논문집
    • /
    • 제11권6호
    • /
    • pp.31-37
    • /
    • 2010
  • 본 연구에서는 multi-bed 플레이트로 폐열재생 부분과 촉매반응 부분으로 구성되어 있는 복합열산화 시스템(Hybrid Thermal Oxidation System)을 이용하여 저온에서 주입 밸브 교체 시간간격과 유입유량을 변화시켜 VOCs(MEK와 Toluene) 제거를 평가하고자 하였다. $350^{\circ}C$의 연소온도 조건에서 VOCs는 완전히 전환되었으며 당량비에 따른 전환율 또한 100%에 근접하였고, HTO 시스템의 연소실은 좌우측의 온도가 균형을 이루며 열효율이 매우 높아 폐열회수 및 재생이 효율적이었다. 주입 밸브 교체 시간간격과 유입 유량 변화에 따른 HTO시스템에서의 VOCs 제거 효율은, MEK와 Toluene 모두 안정적으로 높은 91.1~97.4%의 효율을 나타내었으며, 보조연료량 증가보다는 밸브교대시간을 길게 하였을때 제거 효율이 증가하는 경향을 보여 보조연료량 증가보다 밸브교대시간을 증가시키는 것이 제거 효율을 높이는데 효율적으로 판단된다. 이와 같은 연구결과를 고려할 때 HTO시스템은 저농에서도 VOCs 제거, 특히 MEK과 Toluene 제거에 매우 안정적이며 콤팩트한 시스템으로 판단되며, 적은 설치 부지로 중소기업이 요구하는 새로운 VOCs 제거 시스템으로 적용 가능하리라 판단된다.