• Title/Summary/Keyword: tolerance limit

Search Result 207, Processing Time 0.021 seconds

Optimum Design of Dual Orifice Fuel Nozzle (이중 오리피스 연료 노즐 최적설계)

  • Lim, O-Kaung;Choi, Eun-Ho;Kim, Sung-Sub
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.4
    • /
    • pp.407-416
    • /
    • 2007
  • Fuel spray nozzle has a critical effect on combustion characteristics. Mass flow rate and SMD(sauter mean diameter) were selected as design variables by using the experiment data of various types of duplex fuel nozzles for the swirl atomizers. The sensitivity of each design variable on the mass flow rate and SMD was analyzed and the uniformity of mass flow rate was investigated through the shape optimization of duel-orifice-type swirl atomizers. The design variables that have a little effect on the optimum design were excluded using the DOE(design of experiments) method, which enabled the optimization of sensitive design variables on mass flow rate and limit tolerance. The SMD of the research spray nozzle that was used in this study was found to be most similar to that of the calculation results using the Jasuja's SMD relationship. This study showed the specific characteristics of duel orifice type swirl atomizers and the optimization of these kinds of nozzle. This study provided the optimization design of mass flow rate and its allowable tolerance.

Compound Backup Technique using Hot-Cold Data Classification in the Distributed Memory System (분산메모리시스템에서의 핫콜드 데이터 분류를 이용한 복합 백업 기법)

  • Kim, Woo Chur;Min, Dong Hee;Hong, Ji Man
    • Smart Media Journal
    • /
    • v.4 no.3
    • /
    • pp.16-23
    • /
    • 2015
  • As the IT technology advances, data processing system is required to handle and process large amounts of data. However, the existing On-Disk system has limit to process data which increase rapidly. For that reason, the In-Memory system is being used which saves and manages data on the fast memory not saving data into hard disk. Although it has fast processing capability, it is necessary to use the fault tolerance techniques in the In-Memory system because it has a risk of data loss due to volatility which is one of the memory characteristics. These fault tolerance techniques lead to performance degradation of In-Memory system. In this paper, we classify the data into Hot and Cold data in consideration of the data usage characteristics in the In-Memory system and propose compound backup technique to ensure data persistence. The proposed technique increases the persistence and improves performance degradation.

Evaluation and Comparative Analysis of Scalability and Fault Tolerance for Practical Byzantine Fault Tolerant based Blockchain (프랙티컬 비잔틴 장애 허용 기반 블록체인의 확장성과 내결함성 평가 및 비교분석)

  • Lee, Eun-Young;Kim, Nam-Ryeong;Han, Chae-Rim;Lee, Il-Gu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.2
    • /
    • pp.271-277
    • /
    • 2022
  • PBFT (Practical Byzantine Fault Tolerant) is a consensus algorithm that can achieve consensus by resolving unintentional and intentional faults in a distributed network environment and can guarantee high performance and absolute finality. However, as the size of the network increases, the network load also increases due to message broadcasting that repeatedly occurs during the consensus process. Due to the characteristics of the PBFT algorithm, it is suitable for small/private blockchain, but there is a limit to its application to large/public blockchain. Because PBFT affects the performance of blockchain networks, the industry should test whether PBFT is suitable for products and services, and academia needs a unified evaluation metric and technology for PBFT performance improvement research. In this paper, quantitative evaluation metrics and evaluation frameworks that can evaluate PBFT family consensus algorithms are studied. In addition, the throughput, latency, and fault tolerance of PBFT are evaluated using the proposed PBFT evaluation framework.

Analysis of Static Lateral Stability Using Mathematical Simulations for 3-Axis Tractor-Baler System

  • Hong, Sungha;Lee, Kyouseung;Kang, Daein;Park, Wonyeop
    • Journal of Biosystems Engineering
    • /
    • v.42 no.2
    • /
    • pp.86-97
    • /
    • 2017
  • Purpose: This study aims to evaluate the applicability of a tractor-baler system equipped with a newly developed round baler by conducting stability analyses via static-state mathematical simulations and verification experiments for the tractor equipped with a loader. Methods: The centers of gravity of the tractor and baler were calculated to analyze the transverse overturning of the system. This overturning of the system was analyzed by applying mathematical equations presented in previous research and comparing the results with those obtained by the newly developed mathematical simulation. For the case of the tractor equipped with a loader, mathematical simulation results and experimental values from verification experiments were compared and verified. Results: The center of gravity of the system became lower after the baler was attached to the tractor and the angle of transverse overturning of the system steadily increased or decreased as the deflection angle increased or decreased between $0^{\circ}$ and $180^{\circ}$ on the same gradient. In the results of the simulations performed by applying mathematical equations from previous research, right transverse overturning occurred when the tilt angle was at least $19.5^{\circ}$ and the range of deflection angles was from $82^{\circ}$ to $262^{\circ}$ in counter clockwise. Additionally, left transverse overturning also occurred at tilt angles of at least $19.5^{\circ}$ and the range of deflection angles was from $259^{\circ}$ to $79^{\circ}$ in counter clockwise. Under the $0^{\circ}$ deflection angle condition, in simulations of the tractor equipped with a loader, transverse overturning occurred at $17.9^{\circ}$, which is a 2.3% change from the results of the verification experiment ($17.5^{\circ}$). The simulations applied the center of gravity and the correlations between the tilt angles, formed by individual wheel ground contact points excluding wheel radius and hinge point height, which cannot be easily measured, for the convenient use of mathematical equations. The results indicated that both left and right transverse overturning occurred at $19.5^{\circ}$. Conclusions: The transverse overturning stability evaluation of the system, conducted via mathematical equation modeling, was stable enough to replace the mathematical equations proposed by previous researchers. The verification experiments and their results indicated that the system is workable at $12^{\circ}$, which is the tolerance limit for agricultural machines on the sloped lands in South Korea, and $15^{\circ}$, which is the tolerance limit for agricultural machines on the sloped grasslands of hay in Japan.

Influence of Temperature, Salinity and Hypoxia on Survival and Metabolic Rate in the Ark Shell, Scapharca broughtonii (피조개의 생존과 대사에 미치는 수온, 염분 및 저산소의 영향)

  • Shin, Yun-Kyung;Kim, Byoung-Hak;Choi, Nack-Joong;Jung, Choon-Goo;Park, Min-Woo
    • The Korean Journal of Malacology
    • /
    • v.24 no.1
    • /
    • pp.59-66
    • /
    • 2008
  • The ark shell, Scapharca broughtonii were collected from the Jinhae bay in Kyungnam, Korea from April 2006 to October 2007. To assess how much they have tolerance against hypoxia under the compound condition of temperature and salinity, survivorship, oxygen consumption rate and external features of Scapharca broughtonii were measured, The 7 days-$LC_{50}$ of dissolved oxygen (DO) for Scapharca broughtonii at $15^{\circ}C$-ordinary sea water and $26{\pm}1$ psu was 1.98mg/L (confidence limit: 1,45-2.39 mg/L) and 2.63mg/L (confidence limit: 1.76-3.37mg/L) respectively. Whereas 3 days-$LC_{50}$ at $25^{\circ}C$-ordinary sea water was 3.89mg/L (confidence limit: 3.36-4.55 mg/L) and 4 days-$LC_{50}$ at $25^{\circ}C-26{\pm}1$ psu was 3.74mg/L (confidence limit: 3.19-4,43 mg/L). Oxygen consumption rate with each experimental group was decreased during the period exposed to hypoxia. To recovery, they were replaced to ordinary and oxygen consumption rate was increased a little, but all died, The color of the umbo of shell in Scapharca broughtonii was changed dark during hypoxia. These data will provide important fundamental information for examining the causes of mass mortality of shellfish in the summer.

  • PDF

Microbiological Contamination and Sanitary Management of Aquarium Water in the Busan Area

  • Cho, Kyung-Soon
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.46 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • This research has been performed by our own investigation, also cooperated with Health and Sanification Division and each of district offices in Busan metropolitan city. After choosing, we collected water samples five times for microbiological examination. As a result of investigating in 160 water samples from urban areas, we could detect 88 cases of Vibrio spp. Furthermore, there were four cases exceeding the acceptable limit of aquarium water (100,00/mL) and another four cases exceeding the limit of Coliform group (1,000 below/100 mL). As a result of investigating that we performed for 271 cases of water samples from coastal areas from April to November, we could detect 130 cases of vibrio species and 10 cases of Coliform group. After performing 17 kinds of antibiotic susceptibility test for 41 cases of isolated Vibrio parahaemolyticus, 27 cases showed tolerance to Amplicllin (AM), all of 31 cases showed intermediate resistance only to Cefazolin (CF) but had sensitivity to the rest of them. As a result of performing antibiotic susceptibility test, serum test and PFGE gene analysis on each 10 pair of Vibrio parahaemolyticus detected concurrently from intake-pipe water and, aquarium water, we couldn't get data showing that they are clearly same species in three kinds of test. In addition, UV sterilization, Ozonization and so on. Based on our research, intake pipe didn't have a problem with microbiological contamination so we are sure that the germ came from supplied fish had caused that kind of contamination. For effective management, UV sterilization or Ozonization which can be handled consistently should be adopted in aquarium.

An Application Study of Six Sigma in Clinical Chemistry (6 시그마의 적용에 대한 연구)

  • Chang, Sang Wu;Kim, Nam Yong;Choi, Ho Sung;Park, Yong Won;Chu, Kyung Bok;Yun, Kyeun Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.121-126
    • /
    • 2004
  • The primary goal of six sigma is to improve patient satisfaction, and thereby profitability, by reducing and eliminating defects. Defects may be related to any aspect of customer satisfaction: high product quality, schedule adherence, cost minimization, process capability indices, defects per unit, and yield. Many six sigma metrics can be mathematically related to the others. Literally, six means six standard deviations from the mean or median value. As applied to quality metrics, the term indicates that failures are at least six standard deviations from the mean or norm. This would mean about 3.4 failures per million opportunities for failure. The objective of six sigma quality is to reduce process output variation so that on a long term basis, which is the customer's aggregate experience with our process over time, this will result in no more than 3.4 defect Parts Per Million(PPM) opportunities (or 3.4 Defects Per Million Opportunities. For a process with only one specification limit (upper or lower), this results in six process standard deviations between the mean of the process and the customer's specification limit (hence, 6 Sigma). The results of applicative six sigma experiment studied on 18 items TP, ALB, T.B, ALP, AST, ALT, CL, CK, LD, K, Na, CRE, BUN, T.C, GLU, AML, CA tests in clinical chemistry were follows. Assessment of process performance fits within six sigma tolerance limits were TP, ALB, T.B, ALP, AST, ALT, CL, CK, LD, K, Na, CRE, BUN, T.C, GLU, AML, CA with 72.2%, items that fit within five sigma limits were total bilirubin, chloride and sodium were 3 sigma. We were sure that the goal of six sigma would reduce test variation in the process.

  • PDF

Development of Customer Satisfaction Quality Indicator Considering Producer's Specification Limits (생산자규격을 고려한 소비자만족품질지표의 개발)

  • Kim, Dong-Hyuk;Chung, Young-Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.4
    • /
    • pp.50-58
    • /
    • 2018
  • Process Capability ($C_{pk}$) is a representative measure of how well the producer manages dispersion and bias for the specifications needed by the consumer. This is expressed as a ratio of 6 times the natural tolerance to the specification. As the producer manages the dispersion small, the capacity index becomes higher. And it is classified into 5 grades according to the degree of management. It is a measure of the quality of processes used in most industrial fields. However, $C_{pk}$ is calculated by only reflecting the mean and dispersion of the process, there is a disadvantage that it can not give information about the economic loss caused by the inconsistency of the process with the target value. Overcoming these drawbacks, process capability indexes reflecting various types of loss functions such as $C_{pm}$, $C^+_{pm}$ and $C_{pl}$ have been developed. However, all of these previous studies have applied the limit to the consumer specification, which is based on the traditional and passive quality perception that the quality characteristic should exist within the limits of the consumer specification. In this study, we will develop 'Customer Satisfaction Quality Indicator (CSQI)' which is a quantitative indicator that can be fully evaluated when the manufacturer's specification limit, which is an aggressive quality strategy, is applied. This is expected to be useful decision information for both producers and consumers.

Development of a Lateral Flow Strip-Based Recombinase Polymerase Amplification Assay for the Detection of Haemonchus contortus in Goat Feces

  • Wu, Yao-Dong;Wang, Qi-Qi;Wang, Meng;Elsheikha, Hany M.;Yang, Xin;Hu, Min;Zhu, Xing-Quan;Xu, Min-Jun
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.2
    • /
    • pp.167-171
    • /
    • 2021
  • Haemonchosis remains a significant problem in small ruminants. In this study, the assay of recombinase polymerase amplification (RPA) combined with the lateral flow strip (LFS-RPA) was established for the rapid detection of Haemonchus contortus in goat feces. The assay used primers and a probe targeting a specific sequence in the ITS-2 gene. We compared the performance of the LFS-RPA assay to a PCR assay. The LFS-RPA had a detection limit of 10 fg DNA, which was 10 times less compared to the lowest detection limit obtained by PCR. Out of 24 goat fecal samples, LFS-RPA assay detected H. contortus DNA with 95.8% sensitivity, compared to PCR, 79.1% sensitivity. LFS-RPA assay did not detect DNA from other related helminth species and demonstrated an adequate tolerance to inhibitors present in the goat feces. Taken together, our results suggest that LFS-RPA assay had a high diagnostic accuracy for the rapid detection of H. contortus and merits further evaluation.

Variation of optimization techniques for high dose rate brachytherapy in cervical cancer treatment

  • Azahari, Ahmad Naqiuddin;Ghani, Ahmad Tirmizi;Abdullah, Reduan;Jayamani, Jayapramila;Appalanaido, Gokula Kumar;Jalil, Jasmin;Aziz, Mohd Zahri Abdul
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1414-1420
    • /
    • 2022
  • High dose rate (HDR) brachytherapy treatment planning usually involves optimization methods to deliver uniform dose to the target volume and minimize dose to the healthy tissues. Four optimizations were used to evaluate the high-risk clinical target volume (HRCTV) coverage and organ at risk (OAR). Dose-volume histogram (DVH) and dosimetric parameters were analyzed and evaluated. Better coverage was achieved with PGO (mean CI = 0.95), but there were no significant mean CI differences than GrO (p = 0.03322). Mean EQD2 doses to HRCTV (D90) were also superior for PGO with no significant mean EQD2 doses than GrO (p = 0.9410). The mean EQD2 doses to bladder, rectum, and sigmoid were significantly higher for NO plan than PO, GrO, and PGO. PO significantly reduced the mean EQD2 doses to bladder, rectum, and sigmoid but compromising the conformity index to HRCTV. PGO was superior in conformity index (CI) and mean EQD2 doses to HRCTV compared with the GrO plan but not statistically significant. The mean EQD2 doses to the rectum by PGO plan slightly exceeded the limit from ABS recommendation (mean EQD2 dose = 78.08 Gy EQD2). However, PGO can shorten the treatment planning process without compromising the CI and keeping the OARs dose below the tolerance limit.