• Title/Summary/Keyword: titanium clip

Search Result 9, Processing Time 0.031 seconds

A Study on the magnetization of metal orthopedic prosthesis in magnetic resonance imaging (자기공명 영상장치에서 정형보철금속의 자화(磁化)에 관한 연구)

  • Kim, Hyeong-Gyun;Song, Duk-Chung;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.34-39
    • /
    • 2013
  • For orthopedic artificial metal stainless steel, the magnetization of the magnetic field due to the presence of the titanium was to observe the change. Magnetic field meter (Tesla meters) a certain distance (ISO Centre) 1.5 Tesla magnetic field, the magnetization in the center with the passage of time were measured. Therefore, these artificial metal clip shape and magnetization of the sample size to produce a ferromagnetic material for comparison is the experimental dependence. For comparison of the experimental dependence of the magnetization, thereby producing a test piece size such as shaping prosthetic metal Clip is a ferromagnetic material. The experimental results, the metal orthopedic implants, there was no change in the magnetization indicated by ferromagnetic material in its natural state. However, in a magnetic field of 1.5T (Tesla), showed a sensitivity that is magnetized rapidly compared to the ferromagnetic material. In conclusion, high in the order of Clip, Stainless, of Titanium, the degree of dependence of the magnetization intensity of magnetization was the order Stainless, Titanium, of Clip in a magnetic field.

Titanium Hemostatic Clip Tailoring Method to Overcome Vessel Caliber Discrepancy in Interposition Saphenous Vein Graft for Carotid Artery Resection (경동맥 절제술 후 재건에 사용된 복재정맥의 혈관구경 불일치를 극복하기 위한 Titanium Hemostatic Clip 봉합방법)

  • Kim Sun-Ho;Lim Young-Chang;Lee Sei-Young;Lim Jae-Yol;Choi Eun-Chang
    • Korean Journal of Head & Neck Oncology
    • /
    • v.20 no.2
    • /
    • pp.177-180
    • /
    • 2004
  • Objectives: To completely excise a malignant tumor which invades carotid artery walls, the resection and reconstruction of the carotid artery is essentially required. In most of the cases, interposition graft using a saphenous vein has been performed, however the vessel caliber discrepancy between a common carotid artery and the saphenous vein can result in a problem on surgical technique. We have introduced and evaluated a new titanium hemoclip tailing method to overcome vessel caliber discrepancy in interposition saphenous vein graft for carotid artery resection in the treatment of head and neck cancers. Method: After carotid artery resection, the calibers of the proximal common carotid artery and the vein were compared, and an orifice of the common carotid artery was gradually reduced to a little larger than or the same size as the orifice of the vein by using the titanium hemostatic clip. Subsequently, the common carotid artery was connected to the vein through anastomosis. The same method was also applied to the distal anastomosis site. There after, the vessels were connected through the anastomosis, and a circulation was restored by releasing a vascular clamp. Then, a titanium hemostatic clip-applied redundant portion on the outside of carotid artery was sutured by the blanket edge suture method, using 6-0 Prolene. Results: We have experienced this method in two patients with recurrent squamous cell carcinoma and neuroblostoma, respectively. The interposition saphenous vein graft of these patients was found to maintain good patency on the follow up angiography after one year, and they had no specific vascular complication, such as atherosclerosis. Conclusion: This method made it possible to simply perform the interposition saphenous vein graft (ISVG) within a short time and, therefore, was very useful for shortening the duration to block circulation.

Comparison of Two Techniques on Titanium Clip Application for Ovariohysterectomy in Bitches (개의 난소자궁적출술에 있어서 티타늄클립의 두 가지 적용방법에 대한 비교)

  • Park, Jin-Seok;Kang, Hyun-Gu;Kim, Ill-Hwa
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.566-570
    • /
    • 2011
  • The objective of this study was to assess the complications of titanium clip application after ovariohysterectomy (OHE) and find the proper surgical technique to minimize the complications by comparing the ligation method of ovarian pedicle. Six female beagle dogs were used for this study and they were divided randomly into two groups by ligation techniques: ligation and non-ligation of the suspensory ligament of ovary including ovarian pedicle. To evaluate the difference between two techniques, the location and embedded pattern of applied clips in the abdominal cavity were identified through radiographic tests and autopsy. Hematology tests were also performed to check the existence of inflammation by applied clips and all tests were carried out monthly for 1 year. There were few changes in location of clips of both groups on X-ray views without any migration. Almost all values in hematology of two groups were within the normal range and there were no inflammatory symptoms. All of applied clips in two groups were found near the kidney, but the embedded forms of them showed slight differences. The clips ligating suspensory ligament and ovarian pedicle were located in deep place and thickly surrounded with thin layers of peritoneum. But the clips ligating only ovarian pedicle were found with ease on surface of layer and located in lower place compared with the clips ligating suspensory ligament. These results indicate that the suspensory ligament holds applied clips and minimizes the movement of them. Therefore, ligation of suspensory ligament would be the preferred technique in titanium clip application for OHE.

Effect of Metals used in Orthopedic on Magnetic Resonance Imaging I (정형보철용 금속이 자기공명영상에 미치는 영향 I)

  • Kim, Hyeong-Gyun;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.46-50
    • /
    • 2012
  • Stainless steel and titanium used for orthopedic prosthetic metal, magnetic resonance imaging was measured quantitatively the extent of distortion. Based on reading tests at varying metal magnetic resonance imaging (MRI) were investigated. To two image acquisition conditions for having three metal bodies mutually quantitative it compared analyzed the image of cross direction and the image of lengthwise. As for the distortion of the magnetic resonance image, as for the distortion of image it became small in the order of Clip, Strainless and Titanium. In addition, with T1WI and T2WI which are image acquisition condition T2WI the distortion of image became small. As for the distortion of the image by the metal, you could see the distortion of image in elliptical shape, the metal a bigger image distortion appeared in many parts. If clinical doctor has the condition of the same operation, use the Titanium material, it can, raising the diagnostic value of magnetic resonance image inspection after the operating from Stainless.

Role of Multislice Computerized Tomographic Angiography after Clip Placement in Aneurysm Patients Based on Comparison with Three Dimensional Digital Subtraction Angiography

  • Han, Myung-Hwan;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.103-111
    • /
    • 2007
  • Objective : We evaluated the accuracy of multislice computerized tomographic angiography (MCTA) in the postoperative evaluation of clipped aneurysms by comparising it with three dimensional digital subtraction angiography (3D-DSA). Methods : Between May 2004 and September 2006, we included patients with ruptured cerebral aneurysm of the anterior circulation that was surgically clipped and evaluated by both postoperative MCTA and postoperative 3D-DSA. We measured the diagnostic performance and calculated the sensitivity and specificity of postoperative MCTA compared to 3D-DSA in the detection of aneurysm remnants. Results : A total of 11 neck remnants among the 92 clipped aneurysms (11.9%) were confirmed by 3D-DSA. According to Sindou's classification of aneurysm remnants, 8.7% of clipped aneurysms (8/92) had only neck remnant on 3D-DSA and 3.2% (3/92 aneurysms) had residuum of the neck and sac on 3D-DSA. There were 12 (13.04%) equivocal cases that were difficult to interpret based on the postoperative MCTA. The reasons for the equivocal cases included multiple clips (6 cases, 50.0%). beam-hardening effect (4 cases, 33.3%), motion artifact (1 case, 8.3%), fenestrated clip (1 case, 8.3%) and other combined causes. The sensitivity and specificity of the postoperative MCTA was 81.8% and 88.9%, respectively by ROC curve (p=0.000). Conclusion : MCTA is an accurate noninvasive imaging method used for the assessment of clipped aneurysms in the anterior circulation. If the image quality of postoperative MCTA is good quality and the patient has been treated with a single titanium clip, except a fenestrated clip, the absence of an aneurysm remnant can be diagnosed by MCTA alone and the need for postoperative DSA can be reduced in a large percentage of cases.

Effect of Metals used in Orthopedic on Magnetic Resonance Imaging II (정형 보철용 금속이 자기공명영상에 미치는 영향 II)

  • Kim, Hyeong-Gyun;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.5
    • /
    • pp.115-120
    • /
    • 2012
  • Metals used orthopedic in human magnetic resonance imaging scan of the metal to be inserted, The information to users about the image distortion is to propose a basis for judgment. Metals used orthopedic on Stainless, Titanium and Clip using ferromagnetic artifacts and distortion of the image were measured. Using Phantom "Effect of Metals used in Orthopedic on Magnetic Resonance ImagingI" pig in a paper subsequently was carried out using the same bone. Experimental results using a pure Titanium is a relatively high diagnostic value was found that.

The influence of saliva pH value on the retention and durability of bar-clip attachments

  • Silva, Antonio Sergio;Aroso, Carlos;Ustrell, Raul;Braga, Ana Cristina;Mendes, Jose Manuel;Escuin, Tomas
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.32-38
    • /
    • 2015
  • PURPOSE. The aim of this study was to compare the durability and retention of 4 types of attachments placed over computer aided design/computer aided manufacturing (CAD/CAM) titanium bars when subjected to different pH conditions. MATERIALS AND METHODS. Four commercially available attachments were investigated: Hader Yellow, Hader Red, Ackerman Gold and Ackerman Stainless Steel. These attachments and Ackerman CAD/CAM titanium bars were placed in 2 vessels containing different artificial saliva solutions (pH 7/pH 4) at $37^{\circ}C$ for one month to simulate corrosion conditions, and they were then subjected to mechanical testing (5400 cycles of insertion and removal). RESULTS. The results revealed that there were significant differences in the average values of insertion/removal force due to the pH (F (1, 24)=9.207, P<.05) and the type of attachment (F (3, 24)=11.742, P<.05). CONCLUSION. More acidic pH values were found to have a negative influence on the retention capacity of the attachments.

Effect of Metals used in Orthopedic on Magnetic Resonance Imaging III (정형 보철용 금속이 자기공명영상에 미치는 영향 III)

  • Kim, Hyeong-Gyun;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.42-47
    • /
    • 2012
  • Followed by a paper on the Pig and Bone orthopedic prosthetic, this experiment using Phantom and Bone MRI imaging I, II of orthopedic prosthetic metal effect combines magnetic resonance imaging on metal signal-to-noise ratio(Signal to noise : SNR) and CNR(Contrast to noise: CNR), fat signal suppression(Fat-suppression) images was compared. Specimen trees to measure the reliability of the experimental reproducibility tests and statistical analysis using the SPSS statistical package was applied program SPSS(IBM SPSS Statistice 19) by * P = 0.000 < significance level $({\alpha})$ = 0.01 as a significant there was a correlation(** P < 0.01). SNR and CNR results did not directly proportional to the Titanium, Stainless, Clip CNR and fat signal suppression of the order of images of blood specimens was found to be close to the image. The impact of orthopedic prosthetic metals on magnetic resonance imaging in the diagnostic value of Titanium is relatively high and are meant more.

Arachnoid Remodeling by Clipping Technique Facilitates Surgical Maneuverability during Transsphenoidal Surgery for Pituitary Macroadenoma

  • Kim, Eui Hyun;Park, Soo Jeong;Na, Minkyun;Moon, Ju Hyung;Kim, Sun Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.4
    • /
    • pp.591-597
    • /
    • 2022
  • Objective : Pituitary adenomas frequently extend into the suprasellar space. After a suprasellar tumor is removed, the superiorly extended arachnoid becomes redundant and sinks down into the intrasellar space which often hiders visualization and accessibility to the hidden space behind the evaginated arachnoid. We introduced arachnoid remodeling by clipping technique, and evaluated its usefulness and safety during TSS. Methods : Total 223 patients who underwent arachnoid remodeling with our new clipping technique were included. Redundant arachnoid was clipped along the dural edge with multiple 2.6-mm titanium clips until the redundant arachnoid membrane no longer blocked the surgical route. To check for possible deterioration of hormonal function by this technique, we assessed anterior pituitary function of 166 patients who underwent arachnoid remodeling by clipping and compared this with those of other 429 control patients. Results : Our technique greatly enhanced the accessibility and visualization of intrasellar and parasellar spaces, both of which are generally hindered by redundant arachnoid during transsphenoidal surgery (TSS). We found no difference in anterior pituitary function between a clip-assisted arachnoid remodeling group and the control group, implying that this technique does not result in hypopituitarism. Conclusion : During TSS for pituitary adenomas with suprasellar extension, arachnoid remodeling by clipping technique is very useful and convenient for the management of the redundant arachnoid membrane to enhance visualization and surgical accessibility.