• Title/Summary/Keyword: tissue electron density

Search Result 51, Processing Time 0.024 seconds

Verification of Radiation Therapy Planning Dose Based on Electron Density Correction of CT Number: XiO Experiments (컴퓨터영상의 전자밀도보정에 근거한 치료선량확인: XiO 실험)

  • Choi Tae-Jin;Kim Jin-Hee;Kim Ok-Bae
    • Progress in Medical Physics
    • /
    • v.17 no.2
    • /
    • pp.105-113
    • /
    • 2006
  • This study peformed to confirm the corrected dose In different electron density materials using the superposition/FFT convolution method in radiotherapy Planning system. The experiments of the $K_2HPO_4$ diluted solution for bone substitute, Cork for lung and n-Glucose for soft tissue are very close to effective atomic number of tissue materials. The image data acquisited from the 110 KVp and 130 KVp CT scanner (Siemes, Singo emotions). The electron density was derived from the CT number (H) and adapted to planning system (Xio, CMS) for heterogeneity correction. The heterogeneity tissue phantom used for measurement dose comparison to that of delivered computer planning system. In the results, this investigations showed the CT number is highly affected in photoelectric effect in high Z materials. The electron density in a given energy spectrum showed the relation of first order as a function of H in soft tissue and bone materials, respectively. In our experiments, the ratio of electron density as a function of H was obtained the 0.001026H+1.00 in soft tissue and 0.000304H+1.07 for bone at 130 KVp spectrum and showed 0.000274H+1.10 for bone tissue in low 110 KVp. This experiments of electron density calibrations from CT number used to decide depth and length of photon transportation. The Computed superposition and FFT convolution dose showed very close to measurements within 1.0% discrepancy in homogeneous phantom for 6 and 15 MV X rays, but it showed -5.0% large discrepancy in FFT convolution for bone tissue correction of 6 MV X rays. In this experiments, the evaluated doses showed acceptable discrepancy within -1.2% of average for lung and -2.9% for bone equivalent materials with superposition method in 6 MV X rays. However the FFT convolution method showed more a large discrepancy than superposition in the low electron density medium in 6 and 15 MV X rays. As the CT number depends on energy spectrum of X rays, it should be confirm gradient of function of CT number-electron density regularly.

  • PDF

Ultrastructural and Histochemical Study on the Prostate Gland of a Korean Slug, Incilaria fruhstorferi (한국산 산민달팽이 (Incilaria fruhstorferi) 전립선의 미세구조 및 조직화학적 연구)

  • Chang, Nam-Sub
    • Applied Microscopy
    • /
    • v.27 no.2
    • /
    • pp.155-163
    • /
    • 1997
  • Ultrastructural and histochemical studies were carried out on the prostate gland of a Korean slug (Incilaria fruhstorferi) with light and electron microscopes. The results are as follows. The endothelial tissue of the prostate gland is constituted with tall and narrow ciliated columnar cells, irregularly shaped cells and gland cells in which are included the elongated oval or ellipsoid nucleus those are surrounded by curved membrane. The endothelial tissue of the prostate gland is composed by type-A, B, C and type-D gland cells, and the glanules of type-A, B, and D gland cells are certified to neutral mucopolysaccharide because are related by PAS-alcian blue (pH 2.5) , but the other hand type-C gland cell is only weakly reacted to PAS, but strongly reacted by Million reaction. The glanules of type-A gland cell are small size (about $0.4{\mu}m$) and are seen high electron density, but the glanules of type-B gland cell are large size (about $0.7{\mu}m$) and glanule density is same type-A glanules. Long ellipsoid type-C gland cell contained round nucleus which is well developed beterochromatin in, and that small oval glanules (size, about $0.9{\mu}m$) of moderate high electron density which are formed a group of large glanule together with $4\sim5ea$, but type-D gland cell possessed round small nucleus are seen high electron dense glanules (size, $0.8{\mu}m$).

  • PDF

Effect of Improving Accuracy for Effective Atomic number (EAN) and Relative Electron Density (RED) extracted with Polynomial-based Calibration in Dual-energy CT

  • Daehong Kim;Il-Hoon Cho;Mi-jo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1017-1023
    • /
    • 2023
  • The purpose of this study was to improve the accuracy of effective atomic number (EAN) and relative electron density (RED) using a polynomial-based calibration method using dual-energy CT images. A phantom composed of 11 tissue-equivalent materials was acquired with dual-energy CT to obtain low- and high-energy images. Using the acquired dual-energy images, the ratio of attenuation of low- and high-energy images for EAN was calibrated based on Stoichiometric, Quadratic, Cubic, Quartic polynomials. EAN and RED were extracted using each calibration method. As a result of the experiment, the average error of EAN using Cubic polynomial-based calibration was minimum. Even in the RED image extracted using EAN, the error of the Cubic polynomial-based RED was minimum. Cubic polynomial-based calibration contributes to improving the accuracy of EAN and RED, and would like to contribute to accurate diagnosis of lesions in CT examinations or quantification of various materials in the human body.

The Localization of the Specific Antigenic Protein in the Tissue of Paragonimus westermani Metacercaria (폐흡충 피낭유충 조직에 있어서 특정항원성 단백질의 분포)

  • Kim, Soo-Jin;Roh, Tae-Hoon;Joo, Kyoung-Hwan;Rim, Han-Jong
    • Applied Microscopy
    • /
    • v.27 no.4
    • /
    • pp.403-416
    • /
    • 1997
  • In order to observe the localization of the specific antigenic protein in the tissue of Paragonimus westermani metacercaria, immunogoldlabeling method was applied using IgG of the dog which were infected with Paragonimus westermani metacercaria and IgG of rabbits which were immunized with purified 23 kDa protein from metacercaria of the Paragenimus westermani. The metacercaria worm tissues obtained from Cambaroides similis were embedded in Lowicryl HM20 medium, treated with infected and immunized IgG and protein A gold complex (particle size; 12 nm) and observed by electron microscope. In the tissue antigen of Paragonimus westermani metacercaria, the content of excretory bladder which was highly dense electron density was constituted in the excretory bladder of the parenchymal tissue. In the metacercaria tissues antigen reacted with IgG of infected dog. Labeled gold particles distributed on the interstitial matrix of parenchymal cells, fibrous granules of parenchymal tissue and the content of excretory bladder. High antigenicity was observed on content of excretory bladder. It was found to be specifically distributed at the tissue of Paragonimus westermani metacercaria. In the tissues antigen reacted with IgG of immunized rabbit. Labeled gold particles randomly distributed on the interstitial matrix and fibrous granules of parenchymal tissue but in the content of excretory bladder of Paragonimus westermani metacercaria, gold particles were richly labeled. Therefore, the 23 kDa protein contained with Paragonimus westermani metacercaria was found protein which was specifically constituted at the content of excretory bladder of Paragonimum westermani metacercaria. The 23 kDa protein was commonly contained from of Paragonimus westermani metacercaria to adult and showed strong antigenicity against the immunized and infected IgG.

  • PDF

Mantle Ultrastructure of the Granular Ark, Tegillarca granosa (Bivalvia: Acridae) (꼬막(Tegillarca granosa) 외투막의 미세구조)

  • MA Kyung Hwa;LEE Jung Sick
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.3
    • /
    • pp.270-275
    • /
    • 2003
  • Histochemical characteristic and ultrastructure of the mantle of the granular ark, Tegillarca granosa are described using light and electron microscopy. The mantle of the clam is composed of outer epidermis, connective tissue and inner epidermis. The simple epidermis consists of supporting cells, ciliated cells of the two types and secretory cells of three types. Connective tissue is composed of matrix, collagen fibers, muscular fibers and hemolymph sinus. The columnar supporting cell is covered with microvilli on the free surface. Ciliated cells are distributed in the inner epidermis with numerous cilia, microvilli and tubular mitochondria. Secretory cells could be classified into three types (A, B and C) with morphological features of the secretory granules. Type A secretory cells contains secretory granules with fibrous materials of high electron density Type B secretory cells are more abundant than the other cells, and contains secretory granules of membrane-bounded and high electron density. Secretory granules of the type C cells are divided into fibrous core layer and homogeneous peripheral layer. Type B secretory cells are abundant in the both epidermis of marginal mantle, while large number of type A and C secretory cells are evident in the outer epidermis of the central and umbonal mantle. This result showed that the outer and the inner epidermis of the mantle are related with shell formation and cleaning of the mantle cavity, respectively.

Analysis of the cause of dose delivery errors due to changes in abdominal gas volume during MRgART pancreatic cancer (췌장암 MRgART시 복부가스용적 변화에 의한 선량전달오류 원인 분석)

  • Ha, Min Yong;Son, Sang Jun;Kim, Chan Yong;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.73-83
    • /
    • 2020
  • Purpose: The purpose of this study is to confirm the matching of the electron density between tissue and gas due to variation of abdominal gas volume in MRgART (Magnetic Resonance-guided Adaptive Radiation Therapy) for pancreatic cancer patients, and to confirm the effect on the dose change and treatment time. Materials and Methods: We compared the PTV and OAR doses of the initial plan and the AGC(Abdominal gas correction) plans to one pancreatic cancer patient who treated with MRgART using the ViewRay MRIdian System (Viewray, USA) at this clinic. In the 4fx AGC plans, Beam ON(%) according to the patient's motion error was checked to confirm the effect of abdominal gas volume on treatment time. Results: Comparing the Initial plan with the average value of AGC plan, the dose difference was -7 to 0.1% in OAR and decreased by 0.16% on average, and in PTV, the dose decreased by 4.5% to 5.5% and decreased by 5.1% on average. In Adaptive treatment, as the abdominal gas volume increased, the Beam ON(%) decreased. Conclusion: Abdominal gas volume variation causes dose change due to inaccurate electron density matching between tissue and gas. In addition, if the abdominal gas volume increases, the Beam ON(%) decreases, and the treatment time may increase due to the motion error of the patient. Therefore, in MRgART, it is necessary to check the electron density matching and minimize the variability of the abdominal gas.

Ovarian Structure and Oogenesis of the Spiny Top Shell, Batillus cornutus (Lightfoot, 1786) (Gastropoda: Turbinidae) (소라, Batillus cornutus의 난소구조 및 난자형성과정)

  • Jung, Gui-Kwon;Park, Jung-Jun;Ju, Sun-Mi;Jin, Young-Guk;Lee, Jung-Sick
    • The Korean Journal of Malacology
    • /
    • v.23 no.2
    • /
    • pp.209-216
    • /
    • 2007
  • The ovarian structure and ultrastructural changes in germ cells during oogenesis of the spiny top shell, Batillus cornutus, have been investigated by light and electron microscopic observations. Specimens of the spiny top shell were collected from the subtidal zone of Wando, south coast of Korea. Spiny top shell was dioecious. The ovary was located on the surface of the hepatopancreas in the spiral posterior region. The ovary had greenish color in the gonadal mature season. The ovary comprised many ovarian lobules, and the ovarian lobule consisted of connective mesenchymal tissue and epithelial cells. Oogonium had a large nucleus with nucleolus of high electron density. In previtellogenic oocyte, small yolk granules of low electron density were scattered in the cytoplasm. Oocytes in the initial vitellogenic stage were connected with the ovarian lobule by egg stalk. The result of TEM observations showed that initial vitellogenic oocyte contained well-developed Golgi complex, endoplasmic reticula, tubular mitochondria and numerous yolk granules of various electron densities and sizes. The electron density, size and quantity of yolk granules which were distributed in the active vitellogenic oocyte were increased compared to the previous stage. Thickness of egg envelope in the late active vitellogenic oocyte was approximately 4.4 $[\mu}m$. Cytoplasm of ripe oocyte was filled with proteid yolk globules of high electron density and lipid yolk globules of low electron density. In this stage, the thickness of egg envelope was approximately 6.5 ${\mu}m$.

  • PDF

Effects of Electron Beam Treatment on the Characteristics of Pulping and Papermaking of Hemp Bast Fibers (전자빔 처리가 대마 인피섬유의 펄프화 및 초지 특성에 미치는 영향)

  • Bae, Paek-Hyun;Seo, Jae-Hwan;Jung, Jin-Ho;Lee, Jae-Jung;Paik, Ki-Hyun;Kim, Hyoung-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.4
    • /
    • pp.51-61
    • /
    • 2012
  • The new alkali pulping process combined with electron beam treatment was applied to utilize hemp bast tissues as a new valuable fibrous resource. Hemp bast tissues have some chemical properties with high lignin contents and holocellulose not to be defiberized by alkali pulping only, compared with the bast tissue of paper mulberry. To make up for the weakness of traditional alkali pulping process, electron beams were directly irradiated into the swelled bast tissue of hemp in NaOH solution and distilled water, and then facilitated the defiberization of hemp bast tissues. The papermaking from hemp bast fibers manufactured by the combination pulping process showed good apparent density, formation structure and air permeability, and had some mechanical properties with lower tensile, tear, burst strength and folding endurance. It is finally concluded that the combination pulping process with electron beam treatment could be suggested a new alternative for non-woody fibers.

Dose Distribution According to the Tissue Composition Using Wedge Filter by Radiochromic Film (쐐기필터 사용 시 레디오크로믹 필름을 이용한 조직에 따른 선량분포 연구)

  • Kim, Yon-Lae;Lee, Jeong-Woo;Park, Byung-Moon;Jung, Jae-Yong;Park, Ji-Yeon;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.157-164
    • /
    • 2012
  • The purpose of this study is to analyze the dose distribution when wedge filter is used in the various tissue electron density materials. The dose distribution was assessed that the enhanced dynamic wedge filter and physical wedge filter were used in the solid water phantom, cork phantom, and air cavity. The film dosimetry was suitable simple to measure 2D dose distribution. Therefore, the radiochromic films (Gafchromic EBT2, ISP, NJ, USA) were selected to measure and to analyze the dose distributions. A linear accelerator using 6 MV photon were irradiated to field size of $10{\times}10cm^2$ with 400 MUs. The dose distributions of EBT2 films were analyzed the in-field area and penumbra regions by using dose analysis program. In the dose distributions of wedge field, the dose from a physical wedge was higher than that from a dynamic wedge at the same electron density materials. A dose distributions of wedge type in the solid water phantom and the cork phantom were in agreements with 2%. However, the dose distribution in air cavity showed the large difference with those in the solid water phantom or cork phantom dose distributions. Dose distribution of wedge field in air cavity was not shown the wedge effect. The penumbra width, out of the field of thick and thin, was observed larger from 1 cm to 2 cm at the thick end. The penumbra of physical wedge filter was much larger average 6% than the dynamic wedge filter. If the physical wedge filter is used, the dose was increased to effect the scatter that interacted with photon and physical wedge. In the case of difference in electron like the soft tissue, lung, and air, the transmission, absorption, and scattering were changed in the medium at high energy photon. Therefore, the treatment at the difference electron density should be inhomogeneity correction in treatment planning system.