• Title/Summary/Keyword: time-switching

Search Result 1,904, Processing Time 0.033 seconds

A Novel Routing Algorithm Based on Load Balancing for Multi-Channel Wireless Mesh Networks

  • Liu, Chun-Xiao;Chang, Gui-Ran;Jia, Jie
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.4
    • /
    • pp.651-669
    • /
    • 2013
  • In this paper, we study a novel routing algorithm based on load balancing for multi-channel wireless mesh networks. In order to increase the network capacity and reduce the interference of transmission streams and the communication delay, on the basis of weighted cumulative expected transmission time (WCETT) routing metric this paper proposes an improved routing metric based on load balancing and channel interference (LBI_WCETT), which considers the channel interference, channel diversity, link load and the latency brought by channel switching. Meanwhile, in order to utilize the multi-channel strategy efficiently in wireless mesh networks, a new channel allocation algorithm is proposed. This channel allocation algorithm utilizes the conflict graph model and considers the initial link load estimation and the potential interference of the link to assign a channel for each link in the wireless mesh network. It also utilizes the channel utilization percentage of the virtual link in its interference range as the channel selection standard. Simulation results show that the LBI_WCETT routing metric can help increase the network capacity effectively, reduce the average end to end delay, and improve the network performance.

Switch to Olanzapine from Clozapine or Risperidone and 12-months Follow Up (Clozapine과 Risperidone에서 Olanzapine으로 교체 연구 : 12개월 추적연구)

  • Cho, Bang Hyun;Jung, In Kwa;Paik, Jong Woo
    • Korean Journal of Biological Psychiatry
    • /
    • v.8 no.1
    • /
    • pp.140-146
    • /
    • 2001
  • In clinical setting, treatment-refractoriness, medication induced tardive dyskinesia and amenorrhea in chronic schizophrenia are frequently problematic. However, there are few guideline solving these problem available to clinicians. The goal of this study was collecting clinical data on clinical effectiveness and predictors of response of switching to olanzapine. We attempted to switch to olanzapine from risperidone and clozapine in chronic 31(risperidone 17, clozapine 14) schizophrenia and schizoaffective disorder patients suffering from sustained symptoms, weekly blood monitoring, medication induced tardive dyskinesia and amenorrhea. Previous antipsychotics dosage was gradually decreased for 2 or 3weeks, at the same time olanzapine dosage was gradually increased. At baseline, after 1 week, after 2 weeks and after 4 weeks we checked Brief Psychiatric Rating Scale, Clinical Global Impression Scale, Sympson-Angus Rating Scale, Barnes Akathisia Rating Scale and followed up after 12 months. Successful switch after 4 weeks was achieved in 25 patients(clozapine 9(64.2%), risperidone 16(94.1%)). Overall, mean BPRS and CGI scores increased significantly. Successful maintenance after 12 months was achieved in 17 patients(clozapine 5(35.7%), risperidone 12(70.5%)). Overall, mean BPRS and CGI scores increased significantly too. Switching to olanzapine from other atypical antipsychotics is recommendable in chronic schizophrenia with treatment refractoriness and drug induced side effect.

  • PDF

A New Zero-Current-Transition Buck Converter (새로운 영전류 천이형 벅 컨버터)

  • 최현칠
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.556-563
    • /
    • 2001
  • In this paper a new zero current transition pulse width modulation (ZCT-PWM) buck converter is proposed to combine the desirable feature of both the conventional buck converter and resonant converters. In this proposed scheme an auxiliary circuit is added to the conventional buck converter and used to achieve soft-switching for both the main switch and the freewheeling diode while not incurring any additional losses due to auxiliary circuit And this converter operates exactly like the conventional PWM converter except for a short particular time interval. The operation of the proposed converter is explained and analyzed. and design guidelines are presented. To validate the feasibility of the proposed converter, a 100KHz 180-W prototype is built and tested.

  • PDF

Parameter Identification of a Synchronous Reluctance Motor by using a Synchronous PI Current Regulator at a Standstill

  • Hwang, Seon-Hwan;Kim, Jang-Mok;Khang, Huynh Van;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.491-497
    • /
    • 2010
  • This paper proposes an estimation algorithm for the electrical parameters of synchronous reluctance motors (SynRMs) by using a synchronous PI current regulator at standstill. In reality, the electrical parameters are only measured or estimated in limited conditions without fully considering the effects of the switching devices, connecting wires, and magnetic saturation. As a result, the acquired electrical parameters are different from the real parameters of the motor drive system. In this paper, the effects of switching devices, connecting wires, and the magnetic saturation are considered by simultaneously using the short pulse and closed loop equations of resistance and synchronous inductances. Therefore, the proposed algorithm can be easily and safely implemented with a reduced measuring time. In addition, it does not need any external or additional measurement equipment, information on the motor's dimensions, and material characteristics as in the case of FEM. Several experimental results verify the effectiveness of the proposed algorithm.

Model Predictive Control for Shunt Active Power Filter in Synchronous Reference Frame

  • Al-Othman, A.K.;AlSharidah, M.E.;Ahmed, Nabil A.;Alajmi, Bader. N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.405-415
    • /
    • 2016
  • This paper presents a model predictive control for shunt active power filters in synchronous reference frame using space vector pulse-width modulation (SVPWM). The three phase load currents are transformed into synchronous rotating reference frame in order to reduce the order of the control system. The proposed current controller calculates reference current command for harmonic current components in synchronous frame. The fundamental load current components are transformed into dc components revealing only the harmonics. The predictive current controller will add robustness and fast compensation to generate commands to the SVPWM which minimizes switching frequency while maintaining fast harmonic compensation. By using the model predictive control, the optimal switching state to be applied to the next sampling time is selected. The filter current contains only the harmonic components, which are the reference compensating currents. In this method the supply current will be equal to the fundamental component of load current and a part of the current at fundamental frequency for losses of the inverter. Mathematical analysis and the feasibility of the suggested approach are verified through simulation results under steady state and transient conditions for non-linear load. The effectiveness of the proposed controller is confirmed through experimental validation.

A Branch-and-price Approach to the ATM Switching Node Location Problem

  • Kim, Deokseong;Park, Sunsoo;Lee, Kyungsik;Park, Kyungchul
    • Industrial Engineering and Management Systems
    • /
    • v.3 no.2
    • /
    • pp.92-99
    • /
    • 2004
  • We consider the ATM switching node location problem (ANLP). In this problem, there are two kinds of facilities, hub facilities and remote facilities, with different capacities and installation costs. We are given a set of customers with each demand requirements, a set of candidate installation sites of facilities, and connection costs between facilities. We need to determine the locations to place facilities, the number of facilities for each selected location, the set of customers who are connected to each installed hub via installed remote facilities with minimum cost, while satisfying demand requirements of each customer. We formulate this problem as a general integer programming problem and solve it to optimality. In this paper, we present a preprocessing procedure to tighten the formulation and develop a branch-and-price algorithm. In the algorithm, we consider the integer knapsack problem as the column generation problem. Computational experiments show that the algorithm gives optimal solutions in a reasonable time.

Simulation of Capacitively Graded Bushing for Very Fast Transients Generated in a GIS during Switching Operations

  • Rao, M.Mohana;Rao, T. Prasad;Ram, S.S. Tulasi;Singh, B.P.
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.36-42
    • /
    • 2008
  • In a gas insulated substation (GIS), Very Fast Transient Over-voltages (VFTOs) are generated due to switching operations and ground faults. These fast transients are associated with high frequency components of the order of a few hundreds of MHz. These transients may cause internal faults i.e., layer-to-layer faults or minor faults in a capacitively graded bushing, which is one of the important pieces of terminal equipment for GIS. In the present study, the PSPICE model has been developed to calculate the voltage distribution across the layers of 420kV graded bushing for high frequency pulses of rise time 1 to 50ns, which simulate the VFTO. For this simulation, an equivalent electrical network of bushing with different equivalent layers has been considered. The effect of different equivalent layers modeling circuits on the non-uniform voltage factor has been analysed. The influence of copper strip inductance on voltage distribution across layers has also been analysed for various rise times of high frequency transients. Finally, the leakage current of the bushing is calculated for evaluating the bushing condition under these transients.

Enhancing Medical Images by New Fuzzy Membership Function Median Based Noise Detection and Filtering Technique

  • Elaiyaraja, G.;Kumaratharan, N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2197-2204
    • /
    • 2015
  • In recent years, medical image diagnosis has growing significant momentous in the medicinal field. Brain and lung image of patient are distorted with salt and pepper noise is caused by moving the head and chest during scanning process of patients. Reconstruction of these images is a most significant field of diagnostic evaluation and is produced clearly through techniques such as linear or non-linear filtering. However, restored images are produced with smaller amount of noise reduction in the presence of huge magnitude of salt and pepper noises. To eliminate the high density of salt and pepper noises from the reproduction of images, a new efficient fuzzy based median filtering algorithm with a moderate elapsed time is proposed in this paper. Reproduction image results show enhanced performance for the proposed algorithm over other available noise reduction filtering techniques in terms of peak signal -to -noise ratio (PSNR), mean square error (MSE), root mean square error (RMSE), mean absolute error (MAE), image enhancement factor (IMF) and structural similarity (SSIM) value when tested on different medical images like magnetic resonance imaging (MRI) and computer tomography (CT) scan brain image and CT scan lung image. The introduced algorithm is switching filter that recognize the noise pixels and then corrects them by using median filter with fuzzy two-sided π- membership function for extracting the local information.

A Study on SFCL with IGBT Based DC Circuit Breaker in Electric Power Grid

  • Bae, SunHo;Kim, Hongrae;Park, Jung-Wook;Lee, Soo Hyoung
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1805-1811
    • /
    • 2017
  • Recently, DC systems are considered as efficient electric power systems for renewable energy based clean power generators. This discloses several critical issues that are required to be considered before the installation of the DC systems. First of all, voltage/current switching stress, which is aggravated by large fault current, might damage DC circuit breakers. This problem can be simply solved by applying a superconducting fault current limiter (SFCL) as proposed in this study. It allows a simple use of insulated-gate bipolar transistors (IGBTs) as a DC circuit breaker. To evaluate the proposed resistive type SFCL application to the DC circuit breaker, a DC distribution system is composed of the practical line impedances from the real distribution system in Do-gok area, Korea. Also, to reflect the distributed generation (DG) effects, several DC-to-DC converters are applied. The locations and sizes of the DGs are optimally selected according to the results of previous studies on DG optimization. The performance of the resistive type SFCL applied DC circuit breaker is verified by a time-domain simulation based case study using the power systems computer aided design/electromagnetic transients including DC (PSCAD/ EMTDC(R)).

Performance Evaluation of Buffer Management Schemes for Implementing ATM Cell Reassembly Mechanism

  • Park, Gwang-Man;Kang, Sung-Yeol;Lie, Chang-Hoon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.22 no.2
    • /
    • pp.139-151
    • /
    • 1997
  • An ATM switching system may be designed so that communications between processors of its control part can be performed via its switching network rather than a separate inter-processor communications (IPC) network. In such a system, there should be interfaces to convent IPC traffic from message format to cell format and vice versa, that is, mechanisms to perform the SAR (Segmentation And Reassembly) sublayer functions. In this paper, we concern the cell reassembly mechanism among them, mainly focussed on buffer management schemes. We consider a few alternatives to implement cell reassembly function block, namely, separated buffering, reserved buffering and shared buffering in this paper. In case of separated and reserved buffering, we employ a continuous time Markov chain for the performance evaluation of cell reassembly mechanism, judicially defining the states of the mechanism. Performance measures such as measage loss probability, mean number of message queued in buffer and average reassembly delay are obtianed in closed forms. In case of shared buffering, we compare the alternatives for implementing cell reassembly function block using simulation because it is almost impossible to analyze the mechanism of shared buffering by analytical modeling. Some illustrations are given for the performance analysis of the alternatives to implement cell reassembly function block.

  • PDF