• Title/Summary/Keyword: time-switching

Search Result 1,904, Processing Time 0.036 seconds

Analysis of the electrical characteristics of the novel IGBT with additional nMOS (새로운 구조의 nMOS 삽입형 IGBT의 전기적 특성 분석)

  • Shin, Samuell;Son, Jung-Man;Park, Tea-Ryoung;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.12 no.4
    • /
    • pp.255-262
    • /
    • 2008
  • In this paper, we proposed the novel IGBT with an additional n-type MOS structure to achieve the improved trade-off between turn-off and on-state voltage drop(Vce(sat)). These low on-resistance and the fast switching characteristics of the proposed IGBT are caused by an enhanced electron current injection efficiency which is caused by additional n-type MOS structure. In the simulation result, the proposed IGBT has the lower on state voltage of 2.65V and the shorter turn-off time of 4.5us than those of the conventional IGBT(3.33V, 5us).

  • PDF

A Seamless Adaptive Streaming Scheme for Interactive Multimedia Service in HTTP Adaptive Streaming (HTTP 적응적 스트리밍에서 끊김 없는 대화형 멀티미디어 스트리밍을 위한 전송 기법)

  • Kim, Heekwang;Chung, Kwangsue
    • Journal of KIISE
    • /
    • v.44 no.5
    • /
    • pp.545-552
    • /
    • 2017
  • Because of the explosive growth of mobile devices and development of network technologies, HTTP (Hypertext Transfer Protocol) adaptive streaming has become a new trend in video delivery to provide efficient multimedia streaming services. As interest in personalized broadcasting grows, the study of interactive multimedia has been actively pursued. The interactive multimedia service is a method of playing media according to a scenario selected by the user. Providing the interactive multimedia service with the existing HTTP adaptive streaming causes switching delay and buffer underflow according to the point in time when the user selects the scenario while the client streams the interactive multimedia and therefore decreases the user QoE (Quality of Experience). In this paper, we propose an adaptive streaming scheme for interactive multimedia service in HTTP adaptive streaming to provide seamless playback. We design the architecture and prefetching scheme for interactive multimedia streaming.

New Challenges for Low Cost and High Speed RF ATE System (새로운 저가형 고속 RF 자동화 테스트 시스템)

  • Song, Ki-Jae;Lee, Ki-Soo;Park, Jongsoo;Lee, Jong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.8
    • /
    • pp.744-751
    • /
    • 2004
  • This paper presents the implementation of the low cost and high speed RF ATE(Automatic Test Equipment) system, which can be a reasonable solution for reducing the test cost of RF devices. This paper suggests high speed and precise measurement capabilities which are realized by the 16 independent RF ports with high speed switching time and high accuracy digitizer using the industry standard Versus module eXtensions for Instrument(VXI) General Purpose Interface Bus(GPIB) interfaces. Also, the system has the capabilities of quad-site test which can dramatically increase the device throughput. This paper concludes with the demonstration of the implemented ATE system through the setup of RF Power Amplifier Module(PAM), which is under the most competitive market situation.

Blast Design for Improvement of Limestone Fragmentation (석회석 파쇄도 향상을 위한 발파 설계)

  • Piyush, Rai;Yang, Hyung-Sik
    • Explosives and Blasting
    • /
    • v.28 no.1
    • /
    • pp.19-26
    • /
    • 2010
  • The paper presents a case study of a limestone quarry of the Philippines, where major problems in terms of improper fragmentation, poor wall control, and poor heave of the muck pile were witnessed. The paper highlights the significant role of switching over from diagonal firing pattern to V-type firing pattern, and also of making suitable adjustments in the stemming column length for improved confinement and gas retention. The study revealed that by making aforesaid design modifications in the blast round, marked improvement in blasting results was registered. Looking at the results, it was further contemplated to expand the mesh area in the subsequent blast rounds. The mesh area was incremented from the existing $8.96m^2$ to $12m^2$. The results were meticulously registered in the field, and clearly depicted definite improvements in the blast results in terms of increased P.F., reduced boulder count, reduced FEL cycle time, reduced dozing hours and improved heave.

Control of dissolved Oxygen Concentration and Specific Growth Rate in Fed-batch Fermentation (유가식 생물반응기에서의 용존산소농도 및 비성장속도의 제어)

  • Kim, Chang-Gyeom;Lee, Tae-Ho;Lee, Seung-Cheol;Chang, Yong-Keun;Chang, Ho-Nam
    • Microbiology and Biotechnology Letters
    • /
    • v.21 no.4
    • /
    • pp.354-365
    • /
    • 1993
  • A novel control method with automatic tuning of PID controller parameters has been developed for efficient regulation of dissolved oxygen concentration in fed-batch fermentations of Escherichia coli. Agitation speed and oxygen partial pressure in the inlet gas stream were chosen to be the manipulated variables. A heuristic reasoning allowed improved tuning decisions from the supervision of control performance indices and it coule obviate the needs for process assumptions or disturbance patterns. The control input consisted of feedback and feedforword parts. The feedback part was determined by PID control and the feedforward part is determined from the feed rate. The proportional gain was updated on-line by a set of heuristics rules based on the supervision of three performance indices. These indices were output error covariance, the average value of output error, and input covariance, which were calculated on-line using a moving window. The integral and derivative time constants were determined from the period of output response. The specific growth rate was maintained at a low level to avoid acetic acid accumulation and thus to achieve a high cell density. The specific growthe rate was estimated from the carbon dioxide evolution rate. In fed-batch fermentation, the simutaneous control of dissolved oxygen concentration (at 0.2; fraction of saturated value) and specific growth rate (at 0.25$hr^{-1}$) was satisfactory for the entire culture period in spite of the changes in the feed rate and the switching of control input.

  • PDF

Electrochromic Property of a Conductive Polymer Film Fabricated with Vapor Phase Polymerization (증기중합으로 제조된 전도성 고분자 박막의 전기 변색 특성)

  • Lee, Ji-Yea;Kim, Yu-Na;Kim, Eun-Kyoung
    • Membrane Journal
    • /
    • v.20 no.1
    • /
    • pp.8-12
    • /
    • 2010
  • Poly(3,4-ethylenedioxythiophene) (PEDOT), which has the highest stability in conducting polymer was employed to electrochromic (EC) film and studied about electrochromic properties according to the film fabrication method. PEDOT films were coated by two different methods, electropolymerization (EP) and vapor phase polymerization (VPP). Both of PEDOT films showed dark blue color at dedoped neutral state. Spectroelectrochemistry, switching ability and stability of the devices were investigated by UV-Vis Spectrophotometer and Cyclic voltammetry. Surface morphologies of the PEDOT VPP film at oxidized and reduced state were obtained by AFM. The average surface roughness of the PEDOT-VPP film was 50 nm and more homogeneous than that of the PEDOT-EP. The EC property from the PEDOT-VPP film was improved compared to that of the PEDOT-EP film, to show a response time of 1.5 sec, transmittancechange of 49%, and coloration efficiency of 402.

Performance Investigation of Semi-Active Control Logic to Minimize a Pointing Performance Degradation of On-Board Payload by Chattering Effects (Chattering에 의한 위성 탑재체 지향성능저하 최소화를 위한 반능동제어기법 성능분석)

  • Oh, Hyun-Ung;Choi, Young-Jun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.9
    • /
    • pp.882-889
    • /
    • 2010
  • Semi-active vibration control is one of the attractive control methods for space application due to its robustness as passive damping system and much higher damping performance than passive system. However, a chattering induced by the sudden variation of damping force at the time of On-Off switching of semi-active control device degrades pointing performance of the on-board payload. In this paper, to enhance the pointing performance of the on-board payload, we proposed a semi-active vibration isolation with a strategy for attenuating chattering effect. Numerical simulation results using simplified analysis model indicated that the proposed semi-active control strategy produced much better isolation performance than the conventional Bang-Bang control semi-active control laws derived from skyhook and LQ theories.

Electrical Characteristic of Power MOSFET with Zener Diode for Battery Protection IC

  • Kim, Ju-Yeon;Park, Seung-Uk;Kim, Nam-Soo;Park, Jung-Woong;Lee, Kie-Yong;Lee, Hyung-Gyoo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.1
    • /
    • pp.47-51
    • /
    • 2013
  • A high power MOSFET switch based on a 0.35 ${\mu}m$ CMOS process has been developed for the protection IC of a rechargeable battery. In this process, a vertical double diffused MOS (VDMOS) using 3 ${\mu}m$-thick epi-taxy layer is integrated with a Zener diode. The p-n+Zener diode is fabricated on top of the VDMOS and used to protect the VDMOS from high voltage switching and electrostatic discharge voltage. A fully integrated digital circuit with power devices has also been developed for a rechargeable battery. The experiment indicates that both breakdown voltage and leakage current depend on the doping concentration of the Zener diode. The dependency of the breakdown voltage on doping concentration is in a trade-off relationship with that of the leakage current. The breakdown voltage is obtained to exceed 14 V and the leakage current is controlled under 0.5 ${\mu}A$. The proposed integrated module with the application of the power MOSFET indicates the high performance of the protection IC, where the overcharge delay time and detection voltage are controlled within 1.1 s and 4.2 V, respectively.

A Study on Harmonic Resonance in a DFIG Wind Turbine-generator Connected to a Distribution Power Line (DFIG 풍력발전기가 연계된 배전선로의 고조파 공진 특성에 관한 연구)

  • Choi, Hyung-Joo;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1383-1389
    • /
    • 2013
  • There were telecommunication noise and malfunctions of the electronic devices occurred over a wide area due to the high harmonic voltage and/or current levels of the Back-to-back converter in the DFIG wind power system even though the magnitude of all harmonics is within the international standards. The triangular carrier signals of the PWM used in the power converter system is related to the telecommunication noise because they are in the range of audible frequencies and amplified by a variety of the standing waves that were excited by harmonic voltage sources in the weak grid system such as a long distance distribution transmission lines. This paper describes the characteristics of the harmonics in the wind turbine-generator, numerical analysis and simulation of the harmonics resonance phenomena in the distribution lines as well as measuring induced voltage of the telecommunication lines in parallel with power lines in order to verify the root cause of the telecommunication noise. These noise problems can occur in a wind turbine power system with a non-linear converter at any time, as well as photovoltaic power system. So, the preliminary review of suitable filter devices and switching frequencies of the PWM have to be required by considering the stability of the controller at the design stage but as part of the measures the effect of the telecommunication cable shields was analyzed by comparing the measured data between multi-conductor with/without shields so as to attenuate the sources of the harmonics voltage induced into the telecommunication lines and to apply the most cost-effective measures in the field.

Service Restoration In Distribution Networks Using Cyclic Best-First Search (순환적 최적우선탐색을 이용한 배전계통의 정전복구)

  • Choi, Sang-Yule
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.162-168
    • /
    • 2004
  • Service restoration is an emergency control in distribution control centers to restore out-of-service area as soon as possible when a fault occurs in distribution networks. Therefore, it requires fast computation time and high quality solutions for load balancing. In this paper, a load balance index and heuristic guided best-first search are proposed for these problem. The proposed algorithm consists of two parts. One is to set up a decision tree to represent the various switching operations available. Another is to identify the most effective the set of switches using proposed search technique and a feeder load balance index. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.