• Title/Summary/Keyword: time-switching

Search Result 1,904, Processing Time 0.029 seconds

Traffic Management Scheme for Supporting QoS of VBR/ABR Services in ATM Switching Systems (ATM 스위칭 시스템의 VBR/ABR 서비스 품질 지원을 위한 트랙픽 관리 기법)

  • 유인태
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.8A
    • /
    • pp.1160-1168
    • /
    • 2000
  • This paper presents a real-time integrated traffic management (RITM) scheme that can effectively manage variable bit rate (VBR) and available bit rate (ABR) traffics having unpredictable characteristics in asynchronous transfer mode (ATM) networks. An unique feature of this scheme is that it has a special ATM cell control block which makes it possible to monitor bursty traffics in real-time so that the delay incurred to measure cell arrival rate is minimized. Additionally, the proposed scheme intends to dynamically reassign the leftover network resources to VBR/ABR connections without any deterioration in quality of service (QoS) of the existing connections. The RITM scheme has been verified to reliably monitor incoming traffics and to efficiently manage network resources by computer simulations. The capability of managing the incoming ATM traffics in real-time helps determine an optimal acceptable number of user connections for a given network condition. We can use this value as a threshold to protect the network from being congested and to find out a cost-effective buffer design method.

  • PDF

Terahertz Time Domain Spectroscopy, T-Ray Imaging and Wireless Data Transfer Technologies

  • Paek, Mun-Cheol;Kwak, Min-Hwan;Kang, Seung-Beom;Kim, Sung-Il;Ryu, Han-Cheol;Choi, Sang-Kuk;Jeong, Se-Young;Kang, Dae-Won;Jun, Dong-Suk;Kang, Kwang-Yong
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.3
    • /
    • pp.158-165
    • /
    • 2010
  • This study reviewed terahertz technologies of time domain spectroscopy, T-ray imaging, and high rate wireless data transfer. The main topics of the terahertz research area were investigation of materials and package modules for terahertz wave generation and detection, and setup of the terahertz system for time domain spectroscopy(TDS), T-ray imaging and sub-THz wireless communication. In addition to Poly-GaAs film as a photoconductive switching antenna material, a table-top scale for the THz-TDS/imaging system and terahertz continuous wave(CW) generation systems for sub-THz data transfer and narrow band T-ray imaging were designed. Dielectric properties of ferroelectric BSTO($Ba_xSr_{1-x}TiO_3$) films and chalcogenide glass systems were characterized with the THz-TDS system at the THz frequency range. Package modules for terahertz wave transmitter/receiver(Tx/Rx) photoconductive antenna were developed.

Improvement to Video Display Time Delay when TV Channel switching in Variable Bit Rate Mode of Terrestrial MMS (지상파 MMS 가변 비트율 모드 방송에서 TV 채널 전환 시 발생하는 영상 표출 시간 지연의 개선)

  • Park, Sung-hwan;Chang, Hae-rang;Jeon, Hyoung-joon;Kwon, Soon-chul;Lee, Seung-hyun
    • Journal of Digital Contents Society
    • /
    • v.16 no.5
    • /
    • pp.775-781
    • /
    • 2015
  • EBS started 2HD MMS experimental broadcasting for the first time in Korea on Feb. 11, 2015. It uses the picture compression technique based on MPEG-2 CODEC, and applies the result of the experiment about variable bit rates and changes according to the scanning types, 1080i and 720p. But when changing channels, the delay in displaying picture occurs because of the operation of the variable GOP on MMS broadcasting, which optimizes image quality by application variable bit rates. In this study, verified the relationship between the decoding time of I frames and the GOP set in the encoding step by experimenting and analyzing ON-AIR TS. By using the verification data and adjusts the Encoder GOP parameters, improved the different video display time delays according to the scanning mode 1080i and 720p.

Low-Power Sigma-Delta ADC for Sensor System (센서 시스템을 위한 저전력 시그마-델타 ADC)

  • Shin, Seung-Woo;Kwon, Ki-Baek;Park, Sang-Soon;Choi, Joogho
    • Journal of IKEEE
    • /
    • v.26 no.2
    • /
    • pp.299-305
    • /
    • 2022
  • Analog-digital converter (ADC) should be one of the most important blocks that convert various physical signals to digital ones for signal processing in the digital signal domain. As most operations of the analog circuit for sensor signal processing have been replaced by digital circuits, high-resolution performance is required for ADC. In addition, low-power must be the critical issue in order to extend the battery time of mobile system. The existing integrating sigma-delta ADCs has a characteristic of high resolution, but due to its low supply voltage condition and advanced technology, circuit error and corresponding resolution degradation of ADC result from the finite gain of the operational amplifier in the integrator. Buffer compensation technique can be applied to minimize gain errors, but there is a disadvantage of additional power dissipation due to the added buffer. In this paper, incremental signal-delta ADC is proposed with buffer switching scheme to minimize current and igh-pass bias circuit to improve the settling time.

Fast Join Mechanism that considers the switching of the tree in Overlay Multicast (오버레이 멀티캐스팅에서 트리의 스위칭을 고려한 빠른 멤버 가입 방안에 관한 연구)

  • Cho, Sung-Yean;Rho, Kyung-Taeg;Park, Myong-Soon
    • The KIPS Transactions:PartC
    • /
    • v.10C no.5
    • /
    • pp.625-634
    • /
    • 2003
  • More than a decade after its initial proposal, deployment of IP Multicast has been limited due to the problem of traffic control in multicast routing, multicast address allocation in global internet, reliable multicast transport techniques etc. Lately, according to increase of multicast application service such as internet broadcast, real time security information service etc., overlay multicast is developed as a new internet multicast technology. In this paper, we describe an overlay multicast protocol and propose fast join mechanism that considers switching of the tree. To find a potential parent, an existing search algorithm descends the tree from the root by one level at a time, and it causes long joining latency. Also, it is try to select the nearest node as a potential parent. However, it can't select the nearest node by the degree limit of the node. As a result, the generated tree has low efficiency. To reduce long joining latency and improve the efficiency of the tree, we propose searching two levels of the tree at a time. This method forwards joining request message to own children node. So, at ordinary times, there is no overhead to keep the tree. But the joining request came, the increasing number of searching messages will reduce a long joining latency. Also searching more nodes will be helpful to construct more efficient trees. In order to evaluate the performance of our fast join mechanism, we measure the metrics such as the search latency and the number of searched node and the number of switching by the number of members and degree limit. The simulation results show that the performance of our mechanism is superior to that of the existing mechanism.

Development of HPLC Determination Method for Trace Levels of 1-, 2-Nitropyrenes and 2-Nitrofluoranthene in Airborne Particulates and Its Application to Samples Collected at Noto Peninsula

  • Hayakawa, Kazuichi;Tang, Ning;Sato, Kosuke;Izaki, Akihiko;Tatematsu, Michiya;Hama, Hirotaka;Li, Ying;Kameda, Takayuki;Toriba, Akira
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.3
    • /
    • pp.146-151
    • /
    • 2011
  • 1-Nitropyrene (1-NP), 2-NP and 2-nitrofluoranthene (2-NFR) are useful markers for studying the atmospheric behaviors of polycyclic aromatic hydrocarbons (PAHs) and nitropolycyclic aromatic hydrocarbons (NPAHs). However, present methods for measuring trace levels of these compounds are lesssensitive and laborious. Here we describe several improvements to a previously reported high-performance liquid chromatography-chemiluminescence detection system that allows it to determine trace levels of 1-, 2-NPs and 2-NFR. The proposed system was equipped with a reducer column packed with Pt/Rh instead of zinc whose life-time was limited. The combination of Cosmosil MS-II (monomeric ODS) and AR-II (polymeric ODS) columns was used instead of polymeric ODS columns as the separator column to improve the separation. An ethanol mixture with acetate buffer (pH 5.5) was used in place of an acetonitrile mixture with the same buffer to activate the reducer column. The same ethanol mixture was used as the mobile phase for the clean-up column. The switching time of the column switching valve was optimized to concentrate the amino-derivatives of above NPAHs quantitatively on the concentrator column. The concentrations of bis(2,4,6-trichlorophenly) oxalate and hydrogen peroxide in the chemiluminescence reagent solution were optimized to 0.4 mM and 30 mM, respectively, to increase the sensitivity. Under the above conditions, the detection limits (S/N=3) of 1-, 2-NPs and 2-NFR were 1 fmol (0.25 pg), 10 fmol (2.5 pg) and 4 fmol (1 pg), respectively. The proposed system was effectively used to determine trace levels of 1-, 2-NPs and 2-NFR in airborne particulates collected at Noto Peninsula. The atmospheric concentrations of 1-, 2-NPs and 2-NFR were not more than sub pg $m^{-3}$ levels. They were higher in winter (January) than in summer (July). In both seasons, the concentrations were in decreasing order, [2-NFR]>[1-NP]>[2-NP].

Tissue Distribution and Toxicokinetics of 4-Tert-Octylphenol in Rats (4-Tert-Octylphenol의 랫드에서의 조직분포 및 독성동태에 관한 연구)

  • Kang Mi Kyung;Ahn Mee Ryung;Chung Hye Joo;Choi Sun Ok;Choi Hong Serk;Yang Ji Sun;Lee Yong Bok;Yoo Tae Moo;Sohn Soo Jung
    • Toxicological Research
    • /
    • v.20 no.3
    • /
    • pp.195-203
    • /
    • 2004
  • 4-Tert-Octylphenol (OP) is a surfactant additive widely used in the manufacture of a variety of detergents and plastic products. OP can disrupt endocrine function in humans and animals. This study was carried out to obtain toxicokinetic parameters of OP in male Sprague-Dawley (SD) rats. Male rats were administered with OP by single oral application of 200 mg/kg body weight. Blood, urine and tissues samples were taken at several time intervals after administration. Analysis of samples for OP was performed by column-switching high performance liquid chromatography (HPLC). In addition, we exam-ined tissue distribution and accumulation of OP after single oral application of 50, 100, and 200 mg/kg, single intravenous injection of 1, 5 and 10 mg/kg or daily application of 50 mg/kg for 14 consecutive days. After single oral administration of 200 mg/kg, Cmax of 213 $\pm$ 123 ng/ml was reached within the first 1.3 hr (Tmax) in the plasma. AUC was calculated for 1,333$\pm$484 ngㆍhr/ml. The final elimination half-life of plasma was longer than that of urine, but urinary clearance was lower than oral. A very small fraction of OP (Fe < 0.0017%) was excreted in urine within 24 hr. These results indicated that the major excretion route of OP was not urine. The mean maximal tissue distribution of OP was obserbed at 6 hr after treatment and slowly decreased time-dependently. High OP concentrations were detected in fat at 24 hr. The OP in fat was slowly released with longer elimination half-life and lower clearance than that of other tissues. OP was not accumulated in the liver following single oral application but 14-day oral treatments resulted in two-fold accumulation. It was probably due to the saturation of detoxification pathways. On the other hand, the mRNA expression of cytochrome P450 isoforms except CYP2C11 was not affected by OP at any dose. The expression of CYP2C11 mRNA decreased in a dose-dependent manner. This result suggests that OP changes expression of the male-specific cytochrome P450 isoforms in rat liver, and these changes are closely related to the toxic and estrogenic effect of OP.

Cardiac Magnetic Resonance Imaging Using Multi-physiological Intelligent Trigger System (멀티 생체신호 동기 시스템을 이용한 심장자기공명영상)

  • Park, Jinho;Yoon, Jong-Hyun;Yang, Young-Joong;Ahn, Chang-Beom
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.244-252
    • /
    • 2014
  • Purpose : We proposed a multi-physiological signals based real-time intelligent triggering system(MITS) for Cardiac MRI. Induced noise of the system was analyzed. Materials and Methods: MITS makes cardiac MR imaging sequence synchronize to the cardiac motion using ECG, respiratory signal and second order derivative of $SPO_2$signal. Abnormal peaks due to arrhythmia or subject's motion are rejected using the average R-R intervals and R-peak values. Induced eddy currents by gradients switching in cardiac MR imaging are analyzed. The induced eddy currents were removed by hardware and software filters. Results: Cardiac MR images that synchronized to the cardiac and respiratory motion are acquired using MITS successfully without artifacts caused by induced eddy currents of gradient switching or subject's motion or arrhythmia. We showed that the second order derivative of the $SPO_2$ signal can be used as a complement to the ECG signals. Conclusion: The proposed system performs cardiac and respiratory gating with multi-physiological signals in real time. During the cardiac gating, induced noise caused by eddy currents is removed. False triggers due to subject's motion or arrhythmia are rejected. The cardiac MR imaging with free breathing is obtained using MITS.

ARC Discharge Sound Source in Underwater (수중 아-크 방전음원에 관한 연구)

  • Chang, Jea-Hwan;Chang, Jee-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.1
    • /
    • pp.12-18
    • /
    • 1985
  • In general the impulse sound sources of underwater generated by electric arc discharge had used static energy of the charged capacitors. The author proposed an underwater arc discharge sound source using secondary voltage of high voltage transformer without capacitors. The arc discharge device was composed of a high voltage transformer and a switching system. The impulse current in the primary turn of the high voltage transformer is controlled by the switching system and inductive current of the secondary turn in the high voltage transformer is used in making impulsive arc discharge. A series of experiment have been carried out to observe the acoustic characteristics of the impulse sound source generated by the arc discharge. The results obtained were as follows: 1. Secondary current at the time of arc discharge keeps after ohm's law in the beginning and the maximum current flows out as soon as arc discharge breaks out. 2. A time difference between a start of applied current and a generation of arc discharge sound is the 3msec and it is generated arc sound when breaking down electric insulation at maximum voltage. 3. The sharper the end of electrodes and the higher the secondary voltage, the higher the sound pressure level. 4. Arc discharge sound was generated even at the distance of 100cm between electrodes and was stably reproductive at the gap of 1cm to 100cm. 5. Electric arc discharge sound wave is a shock wave of pulse-width of 0.15msec and spectral distribution of it is plenty of low frequency components less than 10 KHz.

  • PDF

Bioequivalence Test of Triflusal Capsules (트리플루살 캅셀의 생물학적 동등성 평가)

  • 박정숙;이미경;박경미;김진기;임수정;최성희;민경아;김종국
    • Biomolecules & Therapeutics
    • /
    • v.9 no.4
    • /
    • pp.291-297
    • /
    • 2001
  • The bioequivalence of two triflusal products was evaluated with 20 healthy volunteers following single oral dose according to the guidelines of Korea Food and Drug Administration (KFDA). Trisa $l^{R}$ capsule (Whanin Pharm. Corp., Korea) and Disgre $n^{R}$ capsule (Myung-In Pharm. Corp., Korea) were used as test product and reference product, respectively. Both products contain 300 mg of trifusal. One capsule of test product or reference product was orally administered to the volunteers, respectively, by randomized two period crossover study (2$\times$2 Latin square method). Blood samples were taken at predetermined time intervals for 4 hours and the determination of trifusal was accomplished using semi-microbore HPLC equipped with automated column switching system. The analytical method with HPLC was validated according to the Bioanalytic Method Validation guideline by F7A prior to determining the plasma samples. The pharmacokinetic parameters (AU $C_{0-4h}$ $C_{max}$ and $T_{max}$) were calculated and ANOVA test was utilized for statistical analysis of parameters. As a result of the assay validation, the limit of quantification of trifusal in human plasma by current assay procedure was 50 ng/ml using 500 $\mu$l of plasma. The accuracy of the assay was from 97.76% to 116.51% while the intra-day and inter-day coefficient of variation of the same concentration range was less than 15%. Average drug concentration at the designated time intervals and pharmacokinetic parameters calculated were not significantly different between two products (p>0.05). The difference of mean AU $C_{olongrightarrow4hr}$, $C_{max}$, and $T_{max}$ between the two products (2.92, 4.39, and -2.44%, respectively) were less than 20%. The power (1-$\beta$) and treatment difference ($\Delta$) for AU $C_{olongrightarrow4hr}$ and $C_{max}$ were more than 0.8 and less than 0.2, respectively. Although the power for $T_{max}$ was under 0.8, $T_{max}$ of the two products was not significantly different from each other (p>0.05). These results satisfied the criteria of KFDA guideline for bioequivalence, indicating the two products of triflusal were bioequivalent.quivalent.ent.ent.

  • PDF