• Title/Summary/Keyword: time-switching

Search Result 1,904, Processing Time 0.033 seconds

Characteristics Analysis According to Switching of Switched Reluctance Generator (스위치드 릴럭턴스 발전기의 스위칭에 따른 특성)

  • Oh, Jae-Seok;Oh, Ju-Hwan;Kwon, Byung-Il
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1356-1361
    • /
    • 2008
  • A switched reluctance generator(SRG) has simple magnetic structure, and needs simple power electronic driving circuit. But, a SRG are no windings or permanent magnets on the rotor, and there are concentrated windings placed around each salient pole on the stator. Because of the characteristics of time-sharing excitation, the control of SRG is very flexible. And there are several parameters for controlling SRG, such as switch turn-on angle, switch turn-off angle, and exciting voltage and controlling mode, all these will affect the generation greatly. A SRG has positive torque at increasing inductance region and negative torque at decreasing inductance region. In this paper, we studied characteristics about the switch turn-on and off angles according to switch method for constant output voltage of the fixed speed SRG. It is the acoustic noise and torque ripple characteristics. Characteristics for a switch angle and method are presented by experiment using a 50W SRG with 12/8 poles.

A New PLL Frequency Synthesizer with Fast Switching Time (고속의 주파수 절환시간을 갖는 주파수 신시사이저)

  • 박덕규
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1998.05a
    • /
    • pp.258-264
    • /
    • 1998
  • 본문에서 주파수hopping과 이동통신에서 요구되는 고속 주파수 전환이 가능한 새로운 주파수 신시사이저 (Synthesizer)를 제안한다. 종래의 PLL 주파수 신시사이저는 기준 주파수와 출력의 채널 주파수 간격이 동일하기 때문에 기준 주파수를 낮게 하면 매우 긴 동기 시간이 소요된다. 본 논문에서 제안하는 주파수 신시사이저는 새로운 제어 방법을 이용한 다단 펄스 제거 회로를 사용하여 기준 주파수와 채널 간격 주파수를 독립적으로 설정할 수 있기 때문에 종래의 신시사이저와 동일한 채널 간격의 주파수를 유지시키면서 기준 주파수를 높일 수 있고, 또한 루프(loop)이득을 크게 할 수 있다. 따라서 종래의 주파수 신시사이저보다 주파수 절환시간을 크게 단축할 수 있다. 본 논문에서는 주파수 절환시간을 1/100 정도 단축시킬 수 있음을 보여주고 있다.

  • PDF

Attribute about Mobile Game, Market Current State and Switching to Real-time Versus Game (모바일 게임의 특성 및 시장 현황과 실시간 대전형 게임으로의 전환)

  • Lee, Ji-Ho;Won, Jae-Seob;Jung, Woo-Yong;Choi, Nak-Jung;Koh, Seok-Joo
    • Annual Conference of KIPS
    • /
    • 2014.11a
    • /
    • pp.6-9
    • /
    • 2014
  • 스마트폰의 등장과 함께 한국의 모바일 게임 시장은 급속도로 성장하기 시작했다. 그러나 이러한 성장은 애플리케이션의 표절, 독창성 부족, 미완성 등의 부작용을 가져왔다. 본 논문에서는 모바일 게임의 특성과 모바일 게임 시장의 현황을 알아보고, 현 시장에서 경쟁력을 가질 수 있는 기술로써 실시간으로 상대방의 게임판을 확인하여 상대와 동시에 할 수 있는 기술을 제시하고 실제로 PC 버전으로 모바일 게임을 응용하여 구현하여 보았다.

Development of a Neuro Controller for a Negative Output Elementary Luo Converter

  • Kayalvizhi Ramanujam;Natarajan Sirukarumbur Pandurangan;Palanisamy Padmaloshani
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.140-145
    • /
    • 2007
  • The negative output elementary Luo converter is a newly developed DC-DC converter. Due to the time-varying and switching nature of the above converter, its dynamic behavior becomes highly non-linear. Conventional controllers are incapable of providing good dynamic performance for such a converter and, hence, a neural network is utilized as a controller in this work. The performance of the chosen Luo converter using PI versus neuro controls is compared under load and line disturbances using MATLAB and TMS320F2407 DSP. The results validate the superiority of the developed neuro controller.

A Study on the Comparison of Full-Bridge Dual Converter for Various Fast Charging System (다양한 급속 충전용 풀브리지 듀얼 컨버터의 비교 연구)

  • Ban, Choong Hwan;Lee, Y.J;Kwon, W.S;Han, D.H;Choe, J.M;Choe, Gyu-Ha;Eun, J.M
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.279-280
    • /
    • 2012
  • In this paper, as a part of studying the fast battery charger, designed the charging system by applying dual converter. This dual converter was applied to the charging system for reducing time by dividing high current which prevents the damage of parts from heating of components. In this paper continued the task by switching the topology of the dual converter for fast charging battery into SISO, PISO, and PIPO. The study to derive the optimized system topology by analyzing the efficiency of charging system.

  • PDF

A Study on the Three-Phase Active Power Filter using Predictive Current Control Method (예측전류제어방식을 이용한 3상 능동전력필터에 관한 연구)

  • Kwon, Byung-Gi;Woo, Myung-Ho;Jeong, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.138-140
    • /
    • 1994
  • In this paper, a three-phase active power filter using voltage- source PWM converter is designed to eliminate the harmonics and compensate the reactive power in the ac side. The predictive current control method is adopted, which provides constant switching frequency and low current ripple but has inherently one sampling error between the command and the actual current. Here we propose the algorithm which corrects this delay time. The converter voltage obtained from this current control can be accomplished by the space vector modulation method at a voltage-type converter. All control sequences of active filter is executed by a DSP which is designed to calculate floating points at very hight speed. Finally, the validity of this filter using the predictive current control method is demonstrated through experimental results.

  • PDF

A Study on a Boost-Input Self-Driven Active Clamp ZVS Converter (자기구동 능동 클램프를 이용한 부스트 입력형 ZVS 컨버터에 관한 연구)

  • Jin, Ho-Sang;Kim, Hee-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.781-788
    • /
    • 2011
  • This paper proposes a boost-input self-driven active clamp ZVS converter eliminating the extra dirve circuit for the active clamp switch. The converter used the auxiliary winding of the transformer to drive the active clamp switch and to achieve asymmetrical duty control. This paper presents the operation principle and the analyzed results of dynamic characteristics including steady state characteristics of the converter proposed. The experimental results were used to verify the theoretical predictions. A 300W (15V/20A) prototype converter that only exhibited 2-turn winding number in the auxiliary winding was sufficient to drive the active clamp switch on the input voltage of 80V. Finally, the maximum efficiency of 91.2% was achieved for the prototype converter and the proposed converter had stable closed loop characteristic with phase margin $55^{\circ}$.

A study of excitation system of 500MVA short-circuit generator (500MVA급 단락발전기 여자시스템의 특성개선)

  • Jung, Heung-Soo;Kim, Sun-Koo;Roh, Chang-Il;Kim, Won-Man;Lee, Dong-Jun;Kim, Sun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.989-990
    • /
    • 2007
  • The excitation system of 500 MVA short-circuit generator is very important because of operation of various condition, for example, (over) load switching, short-time withstand current, short-circuit making and breaking current, etc. This paper introduces a feature of excitation system of 500MVA short-circuit generator and the function and construction.

  • PDF

Development of the Surge Measurement System for Low Voltage Power Line of Industrial Plants (산업플랜트용 서지 측정 분석 장치 개발)

  • Kim, Y.J.;Kim, J.H.;Chang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1698-1699
    • /
    • 2007
  • This paper deals with the surge measurement system for low voltage power line of industrial plants. It consists of a capacitive divider, A/D conversion part, signal processing and control part. A FPGA and a DSP board were designed to fast signal processing and control. Also, in order to measure lightning surge and switching surge for a long time, data backup device was applied by using SD memory. A performance of the measurement system was verified through evaluation test using impulse calibration generator.

  • PDF

Study on the Effect of Parallel Ground Conductor at the Single Point Bonding in Underground Transmission System (지중송전 편단접지개소에서의 병행지선 설치효과 검토)

  • Kang, J.W.;Park, H.S.;Yoon, H.H.;Yoon, J.K.;Bae, J.H.;Suk, K.H.;Oh, J.M.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.736-737
    • /
    • 2007
  • The single point bonding in underground transmission system can induce high voltage on the sheath when ground fault, lightning serge and switching serge occurs, at that time underground cable systems cannot offer a return path of fault current. Accordingly if fault current, which cannot return to ground, flows at the single point bonding, high voltage can be induced in SVL and that voltage can cause aging and breakdown of SVL. Therefore this paper study on the effect of parallel ground conductor at the single point bonding when ground fault and lightning serge occurs by using ATPDraw.

  • PDF