• Title/Summary/Keyword: time-switching

Search Result 1,904, Processing Time 0.034 seconds

Plugboard type air-conditioner source system with power factor correction circuit (역률 개선회로를 갖는 배전반용 에어컨 시스템)

  • 문상필;서기영;이현우;권순걸;김영문
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.241-244
    • /
    • 2001
  • This paper proposes a nonlinear impedance circuit composed by diodes and inductors or capacitors. This circuit needs no control circuits and switches, and the impedance value is changed by the polarity of current or voltage, This paper presents one of these applications to improve the input current of capacitor input diode rectifiers. The rectifier using the nonlinear impedance circuit id constructed with four diodes and four capacitors in addition to the conventional rectifiers, that is it has eight diodes and five capacitors, including a DC link capacitor. It makes harmonic components of the input current reduce and the power factor improve. A circuit design method is shown by experimentation and confirmed simulation. It explained that compared conventional pulse-width modulated (PWM)inverter with half pulse-width modulated (HPWM) inverter. Proposed HPWM inverter eliminated dead-time by lowering switching loss and holding over-shooting.

  • PDF

Development of Data-Flow Control Algorithm of Wireless Network for Sewage Disposal Facility

  • Jung, Soonho;Shin, Jaekwon;Kang, Jeongjin;Lee, Seungyoun;Lee, Junghoon
    • International journal of advanced smart convergence
    • /
    • v.4 no.2
    • /
    • pp.14-19
    • /
    • 2015
  • Recently, water sewage disposal facilities are able to manage real-time data collection and record management through compact broadband modem LAN switching technology. Therefore, it needs more stable and efficient facility management. So, we required practical use of environmental facilities convergence based on broadband integrated modem. In this paper, we proposed short distance wireless communication network of compact broadband modem for sewage disposal facilities. And it received data inside of water treatment facility using the two communication methods (IEEE802.11x and IEEE802.15.4x). Then, our proposed an data-flow control algorithm of wireless network technology will prioritize processing data when emergency happen through collecting data, analysis data and processing. Lastly, we proved usefulness by experiment and simulation analysis.

The Design of a Fault Tolerant Store Management System

  • Lee, Dongho;Park, Hansol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.10
    • /
    • pp.1-5
    • /
    • 2015
  • Based on the dual hardware and software with distributed recovery blocks, the centralized type fault tolerant store management system(SMS) was proposed. As a result of trade off study related to mutiplex hardware system design, dual single board computer(SBC) was adapted. To verify redundancy function of the proposed structure, the prototype SMS and weapon simulator were used. The proposed SMS operated normally without being affected by a primary SBC failure. The switching time from primary SBC to shadow SBC was within 200 ms. The reliability of the proposed SMS was predicted and compared with the non fault tolerant SMS, thereby it was proved that the proposed SMS has a higher reliability than the non fault tolerant system within effective range.

A Study on the Deterioration Progress of Railway Arresters (철도용 피뢰기의 열화진전에 관한 연구)

  • 길경석;한주섭;한문섭
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.307-311
    • /
    • 2004
  • Arresters are the best protective device on electrical power systems against transient overvoltages generated by lightning and/or switching operation. Nonetheless, arresters are deteriorated by absorption of moisture in the environments of its use, repetition in the protective operation to overvoltages, and some defects at manufacturing. It is therefore important to estimate the electrical characteristic changes of ZnO blocks. In this paper, an accelerated ageing test by a standard lightning impulse current was carried out to extract parameters needed for arrester diagnosis, and leakage current components were measured. Total energy applied to the ZnO blocks at each time is about 1,050[J] in 8/20[${\mu}\textrm{s}$] impulse current. From the experimental results, we proposed electrical parameters and leakage current level to diagnose arrester soundness.

Stability Analysis ant Static Output Feedback Control for switched system (스위칭 시스템을 위한 안정도 분석 및 출력 궤환 제어)

  • Kim, Joo-Won;Park, Jin-Bae;Joo, Young-Hoon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2002.12a
    • /
    • pp.122-125
    • /
    • 2002
  • This paper proposes a stability condition in switched system and then, introduce design method of fuzzy-model-based controller which guarantees the stability. Takagi-Sugeno(75) fuzzy model is employed to design a switching-type fuzzy-model-based ,controller. Furthermore, it is proposed that the design method stabilizing continuous and discrete-time 75 fuzzy model respectively. Each controller in each subspace stabilize the subsystem respectively. In order to guarantee the stability of the global system, it is required to guarantee the stability condition in boundaries with subsystems. The condition which guarantees the stability in boundaries is presented in this paper. Inverted Pendulum system is employed to execute computer simulations. In this computer simulation, the performance of the proposed controller is verified by the control result.

A Study on Tuning of Current Controller for Grid-connected Inverter Using Particle Swarm Optimization (PSO를 이용한 계통연계형 인버터 전류제어기의 자동조정에 관한 연구)

  • Ahn Jong-Bo;Kim Won-gon;Hwang Ki-Hyun;Park Jun-H
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.11
    • /
    • pp.671-679
    • /
    • 2004
  • This paper presents the on-line current controller tuning method of grid-connected inverter using PSO(particle swarm optimization) technique for minimizing the harmonic current. Synchronous frame PI current regulator is commonly used in most distributed generation. However, due to the source voltage distortion, specially in weak AC power system, current may contain large harmonic components, which increase THD(total harmonic distortion) and deteriorates power quality. Therefore, some tuning method is necessary to improve response of current controller. This paper used the PSO technique to tune the current regulator and through simulation and experiments, usefulness of the tuning method has been verified. Especially in simulating the tuning process, ASM(average switching model) of inverter is used to shorten execution time.

Design of High-Response Speed Control System for AC Servomotor Drive (유도형 교류 서보전동기의 고응답 구동회로 설계에 관한 연구)

  • 성영권;조철제
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.5
    • /
    • pp.474-482
    • /
    • 1992
  • This paper describes the speed control system of an induction type ac servomotor drive on the vector control basis of slip frequency and constant secondary flux control for a quick torque response. The system is composed of a digital controller using a SCB-V50 microprocessor and a PWM inverter with power MOSFETs for high speed switching. And, for the measurement of actual instantaneous currents, MDCS A070-051 hall sensors are employed. The rising time of step responce by this system through the test of a 600[W] ac servomotor is 30[ms]. Overall experimental result shows that the drive performance of the system is similar to that of a separately excited armature current control of a dc motior.

  • PDF

The modified HSINFET using the trenched hybrid injector (트렌치 구조의 Hybrid Schottky 인젝터를 갖는 SINFET)

  • 김재형;김한수;한민구;최연익
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.230-234
    • /
    • 1996
  • A new trenched Hybrid Schottky INjection Field Effect Transistor (HSINFET) is proposed and verified by 2-D semiconductor device simulation. The feature of the proposed structure is that the hybrid Schottky injector is implemented at the trench sidewall and p-n junction injector at the upper sidewall and bottom of a trench. Two-dimensional simulation has been performed to compare the new HSINFET with the SINFET, conventional HSINFET and lateral insulated gate bipolar transistor(LIGBT). The numerical results shows that the current handling capability of the proposed HSINFET is significantly increased without sacrificing turn-off characteristics. The proposed HSINFET exhibits higher latch-up current density and much faster switching speed than the lateral IGBT. The forward voltage drop of the proposed HSINFET is 0.4 V lower than that of the conventional HSINFET and the turn-off time of the trenched HSINFET is much smaller than that of LIGBT.

  • PDF

Air-conditioner Power Conversion Equipment with Power Factor Correction Circuit (역률개선회로를 갖는 에어컨용 전력변환장치)

  • Mun, Sang-Pil;Seo, Gi-Yeong;Lee, Hyeon-U;Kim, Yeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.5
    • /
    • pp.345-351
    • /
    • 2000
  • To improve the current waveform of diode rectifiers, we propose a new operating principle of the voltage diode rectifiers. In the conventional voltage rectifier circuit, relatively large capacitors are used to boost the output voltage, while the proposed circuit uses ones and a small reactor not boost the output voltage but improve the input current waveform. A circuit design method is shown and confirmed simulation. It explained that compared conventional PWM(Pulse-width modulated)inverter with HPWM(Half Pulse-width modulated)inverter. Proposed HPWM inverter eliminated dead-time by lowering switching loss and holding over-shooting. Output voltage and current of this paper were applied for real air-conditioner.

  • PDF

Service Restoration Considering Load Balancing In Distribution Networks (부하균등화를 고려한 배전계통의 정전복구)

  • 최상열;김종형;신명철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.9
    • /
    • pp.513-520
    • /
    • 2003
  • Service restoration is an emergency control in distribution constrol centers to restore out-of-service area as soon as possible when a fault occurs in distribution networks. therefore, it requires fast computation time and high quality solutions for load balancing. In this paper. a load balance index and heuristic guided best-first search are proposed for these problem. The proposed algorithm consists of two parts. One is to set up a decision tree to represent the various switching operations available. Another is to identify the most effective the set of switches using proposed search technique and a load balance index. Test results on the KEPCO's 108 bus distribution system show that the performance is efficient and robust.