• 제목/요약/키워드: time-switching

Search Result 1,904, Processing Time 0.03 seconds

A New Switching Method for 3-level GTO Inverter Considering DC-link Voltage Balancing and Minimum on/off time (DC-링크 전압균형과 최소 온-오프 시간을 고려한 새로운 3-레벨 GTO 인버터 제어기법)

  • Lee, Yo-Han;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.373-375
    • /
    • 1994
  • In realizing a three-level GTO inverter, we should keep the voltage balancing of DC-link capacitors and consider minimum on/off time of GTO thyristors in order to make the same blocking voltage across each device and to minimize the harmonic components of the output voltage and current. In this raper, a new PWM scheme based on space voltage vectors, by which it is possible to keep neutral-point voltage and avoid narrow pulse, is presented. Experimental results verify that the proposed PWM control scheme is suitable fur hish power and high voltage three-level GTO inverters applied to induction motor drives.

  • PDF

The study on effective operation of ToP (Timing over Packet) (ToP (Timing over Packet)의 효과적인 운용 방안)

  • Kim, Jung-Hun;Shin, Jun-Hyo;Hong, Jin-Pyo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.136-141
    • /
    • 2007
  • The frequency accuracy and phase alignment is necessary for ensuring the quality of service (QoS) for applications such as voice, real-time video, wireless hand-off, and data over a converged access medium at the telecom network. As telecom networks evolve from circuit to packet switching, proper synchronization algorithm should be meditated for IP networks to achieve performance quality comparable to that of legacy circuit-switched networks. The Time of Packet (ToP) specified in IEEE 1588 is able to synchronize distributed clocks with an accuracy of less than one microsecond in packet networks. But, The ToP can be affected by impairments of a network such as packet delay variation. This paper proposes the efficient method to minimize the expectable delay variation when ToP synchronizes the distributed clocks. The simulation results are presented to demonstrate the improved performance case when the efficient ToP transmit algorithm is applied.

  • PDF

Real-Time Implementation of Variable-Frequency Sinusoidal PWM with Harmonics Suppressing Characteristics. (고조파를 억제하는 가변 주파수 정현파 PWM의 실시간 구현)

  • Cho, Bon-Gu;Jin, Myung-Chul;Lee, Kwang-Won
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1071-1073
    • /
    • 1992
  • PWM technique is widely applied to the control of AC machines. In this paper a new PWM technique for real-time implementation of variable-frequency sinusoidal PWM is introduced. In the proposed algorithm, a low pass filter is used and the switching state is so determined as to minimize the difference between the reference wave and the output of the filter.

  • PDF

Development of Ultrasound Sector B-Scanner(II)-Digital Scan Converter- (초음파 섹터 B-스캐너의 개발(II)-디지탈 스캔 컨버터-)

  • 김주한;김영모
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.133-138
    • /
    • 1986
  • Abstract In a conventional digital sector scan system in the ultrasound medical imaging, the sampling space is in the polar coordinates while the display space is in the cartesian coordinates, which necessitates a coordinate transformation process resultion process resulting the overall system very complex and bulky. In this paper we propose a new architecture of the Digital-Scan-Converter (DSC) for the ultrasound sector scan system in which sampling space is the same as the display space, so the data are displayed as they are acquired without any interpola- tion process required. To implement the above real time DSC. two frequency synthesizes with very high switching time and a low-pass filter are required. The former determines the precise location of the data points and the latter fills the gap betw- een pixels in the horizontal direction.

  • PDF

On The Performance of A Suboptimal Assignment Policy in N-Queue m-Server System

  • Ko Soon-Ju
    • Journal of the military operations research society of Korea
    • /
    • v.17 no.1
    • /
    • pp.43-60
    • /
    • 1991
  • Consider N queues without arrivals and with m identical servers. All jobs are independent and service requirements of jobs in a queue are i.i.d. random variables. At any time only one server may be assigned to a queue and switching between queues are allowed. A unit cost is imposed per job per unit time. The objective is to minimized the expected total cost. An flow approximation model is considered and an upperbound for the percentage error of best nonswitching policies to an optimal policy is found. It is shown that the best nonswitching policy is not worse than $11\%$ of an optimal policy For the stochastic model, we consider the case in which the service requirements of all jobs are i.i.d. with an exponential distribution. A longest first policy is shown to be optimal and a worst case analysis shows that the nonswitching policy which starts with the longest queues is not worse than $11\%$ of the optimal policy.

  • PDF

Variable Structure Control Design for Time-Delay Systems (시간 지연 시스템을 위한 가변 구조 제어기 설계)

  • Choi, Han-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.12
    • /
    • pp.1208-1211
    • /
    • 2010
  • We propose a variable structure control design method for a class of multivariable uncertain state-delayed systems which can be represented by polytopic models. In terms of LMIs, we derive a sufficient condition for the existence of a linear sliding surface guaranteeing the asymptotic stability of the sliding mode dynamics. We parameterize the sliding surface by using the solution of the LMI existence condition. We also give a switching feedback control strategy guaranteeing stable sliding mode. By using a numerical example, we show that our method supplements the existing results and it can be better than the existing results.

Fast ECU Software Update Algorithm using by Extending AUTOSAR CAN Interface (AUTOSAR CAN Interface 확장을 이용한 ECU의 소프트웨어 업데이트 방법)

  • Kim, Jong-Uk;Baek, Jang-Woon;Kwon, Kee-Koo;Lee, Suk-Gyu
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.3
    • /
    • pp.163-169
    • /
    • 2013
  • This paper proposes a novel ECU (Electronic Control Units) update algorithm for AUTOSAR based automotive embedded system. The proposed algorithm provides fast and easy ECU update by extending AUTOSAR CAN Interface. The proposed system removes the update sequences from PDUR to RTE (ECU update program), and it stops other ISRs and operating system in order to reduce unnecessary context switching time. In experimental results, we can see that the proposed algorithm reduces update time.

A Study on the Color Performance of FFS Mode Using the Various Analysis Methods

  • Park, Se-Hong;Park, Eun-Jung;Han, Sang-Hun;Park, Jong-Gyun;Park, In-Cheol;Lee, Kyung-Ha;Lee, Jung-Yeal
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.691-694
    • /
    • 2006
  • So far, we have done much research improving quality of LCD TV. Recently, we have developed 26" WXGA LCD TV by advance fringe field switching (AFFS) technology with smooth and every scene realistic in color image that obtained from the amazing authentic color delivery, optical characteristic and fast response time. Our upgrade device has shown the brightness over 600nits (Color shift <0.015 and Transmittance ratio > 5.5%), gray to gray response time under 6ms, contrast ratio over 1200:1 and viewing angle over 178/178, respectively. And also, motion artifacts improved by fast response of LC with low viscosity, cell gap and dielectric constant.

  • PDF

Low Voltage Active-Clamp Forward Converter with MOSFET Synchronous Rectification (MOSFET 동기정류를 이용한 저전압 능동 클램프 Forward 컨버터에 관한 연구)

  • Kim, Hee-Jun;Ji, Ho-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.110-113
    • /
    • 1993
  • The MOSFET synchronous rectification in the Active-Clamp Forward converter is presented. The Active-Clamp Forward converter has little dead time during the off time of the main switch and it is suitable for the MOSFET synchronous rectification comparing to the other Forward converter topologics. Using the MOSFET synchronous rectification on the Active-Clamp Forward converter with 3.3[V] output and 500[kHz] switching frequency, the improvement of efficiency is achieved comparing with the conventional Schottky barrier diode rectification.

  • PDF

Implementation of Voltage Sag/Swell Compensator using Direct Power Conversion (직접전력변환 방식을 이용한 전압 강하/상승 보상기의 구현)

  • Lee, Sang-Hoey;Cha, Han-Ju;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1544-1550
    • /
    • 2009
  • In this paper, a new single phase voltage sag/swell compensator using direct power conversion is proposed. A new compensator consists of input/output filter, series transformer and direct ac-ac converter, which is a single-phase back-to-back PWM converter without dc-link capacitors. Advantages of the proposed compensator include: simple power circuit by eliminating dc link electrolytic capacitors and thereby, improved reliability and increased life time of the entire compensator; simple PWM strategy or compensating voltage sag/swell at the same time and reduced switching losses in the ac-ac converter. Further, the proposed scheme is able to adopt simple switch commutation method without requiring complex four-step commutation method that is commonly employed in the direct power conversion. Simulation and experimental results are shown to demonstrate the advantages of the new compensator and PWM strategy. A 220V, 3kVA single-phase compensator based on the digital signal processor controller is built and tested.