• Title/Summary/Keyword: time-recording

Search Result 863, Processing Time 0.024 seconds

Shortening of Nursing Record Time about Real Time Transmission Effect of Blood Pressure, Blood Glucose Value Based on U-Healthcare (유-헬스케어 기반 실시간 혈압, 혈당 측정치 전송의 간호기록 시간 단축)

  • Park, Jeong-Eun;Kim, Hwa-Sun;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.15 no.4
    • /
    • pp.164-172
    • /
    • 2013
  • Purpose: The aim was to measure the real-time trans-mission effect of blood-pressure and blood-glucose value based on u-healthcare for saving the time and effort of nursing recording time. Methods: This study used a u-healthcare system based on the international standards for the exchange of health information. In order to verify the effectiveness of the u-healthcare, a clinical trial for the system regarding blood-pressure and blood-glucose targeting of patients with endocrine disorders at KNUH from February 7 to 9, 2012 was performed. Results: According to the analyzed results, of the 86 times the 11 patients were tested, measuring blood-pressure and blood-glucose using the u-healthcare system, we found the time differences between the real-time transfer recording method and existing hospital records that were used in the hospital. Based on the average time interval, there was a difference of 1,090.45 seconds (18.17 minutes). Conclusion: Therefore, it's cumbersome that nurses in the hospital have to record the numerical values of the measured blood-pressure and blood-glucose manually and input the recorded values directly into the electronic nursing record system. However, it was found in terms of the newly designed system, that it could save time and effort for nurses, since measured information is sent to the hospital information system on a real-time basis.

Case Study on the Time Zero (T0) of Event Data Recorder (사고기록장치의 기록 시점에 대한 사례연구)

  • Jongjin Park;Jeongman Park;Jungwoo Park;Byungdeok In
    • Journal of Auto-vehicle Safety Association
    • /
    • v.15 no.2
    • /
    • pp.35-41
    • /
    • 2023
  • On December 19, 2015, as Article 29-3 (Installation of Accident Recording Devices and Provision of Information) of Motor Vehicle Management Act came into force, In Korea, the EDR (Event Data Recorder) reports are often used for the analysis of various traffic accident cases such as multiple collisions, traffic insurance crimes, and sudden unintended acceleration (SUA), and the others. So many investigators have analyzed the driver's behavior and vehicle situation by comparing the time zero in the EDR report to the actual crash time in dash-cam (or CCTV). Time zero (T0) is defined as the reference time for the record interval or time interval when recording an accident in Article 56-2, Enforcement rule of Performance and Standard for Automobile and Automotive parts. Also in the EDR report, time zero (T0) is defined as whichever of the following occurs first; 1. "wake-up" by an air-bag control system, 2. Continuously running algorithms (by monitoring of longitudinal or lateral delta-V), 3. Deployment of a non-reversible deployment restraint. We have already proposed the "Flowchart & Checklist" to adopt the EDR report for traffic accident investigation and the necessity of specialized institutions or courses to systematically educate or analyze the EDR data. Therefore, in this paper, we report to traffic accident investigators notable points and analysis methods based on some real-world traffic accidents that can be misjudged in specifying time zero (T0).

단결정 태양전지의 시정수

  • Jeong, Yu-Ra;Choe, Yong-Seong;Lee, Gyeong-Seop
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.11-11
    • /
    • 2010
  • Recently, annual usage of energy is dramatically increasing by industrialization is going faster and more electricity is needed due to various electronic devices. This paper present relationships between the Vmax, $V_T$, load and time constant of solar cell charge and discharge curve. Charging and discharging recording where the external resistance will become larger Vmax, $V_T$ is decrease and the time increases and decreases there is a possibility of knowing.

  • PDF

A study of real-time holographic display based on volume hologram (체적 홀로그램을 이용한 실시간 홀로그래픽 디스플레이 연구)

  • 강훈종;안충현;이승현
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.203-206
    • /
    • 2003
  • This study is focused on proposing a creative system that can display 3D hologram on the real-time basis. This method applies 3D display on volume hologram based on CGH. The process of implementing the system consists of two stages of fringe pattern recording for passive component that includes information on hologram, and irradiating object beam. Distinguished from an existing electronic holographic display system, this system is free from the process of a huge calculation that is necessary to compose CGH for a real-time 3D display.

  • PDF

Cows per Man-Hour(CMPH) based on Time and Motion Studies for various Milking Systems (착유시설 형태에 따른 착유 노동생산성에 관한 연구)

  • 정태영;김형화;김동일;이정호;이홍표;김종민;이연섭
    • Journal of Animal Environmental Science
    • /
    • v.3 no.2
    • /
    • pp.87-95
    • /
    • 1997
  • This study was peformed to compare work routine time and performance of milking systems by measuring motion and time in milking procedure. Data were collected from thirteen dairy farms among which milking was done by bucket in two farms, by pipelines in three, by tandem parlors in four including one remodeled side-opening, by herringborn parlors in three and by a parallel milking parlor. Recording time and motion for milking parlor. Recording time and motion for milking procedure was performed by stopwatch and notebook computer. Work routine elements were recorded and calculated into cows milked per-man-hour(CMPH). The results are as follows : Average milking time per cow(MTPC) in bucket and pipeline milking systems usually installed in cow stall were 442.7 and 395.8 seconds, respectively. And average CMPH of bucket and pipeline milking system were 144.5, 303.3, 272.5 and 380.3 seconds, respectively. And CMPH of tandem, herringbone, parallel and modified side-opening systems were 24.9, 11.9, 13.2 and 9.5 heads, respectively. CMPH was the highest in the tandem milking system and the lowest in the bucket milking facilities. CMPH, when milked in a parlor resulted in high value compared with bucket or pipeline milking systems installed in cow stable. They showed considerably low CMPH compared with the results of other countries. The reason why so low CMPH could be derived from type and mechanization of facilities and equipment, operator's ability, number of operator, idle time and milking procedure.

Real time control of the growth of Ge-Sb-Te multi-layer film as an optical recording media using in-situ ellipsometry (In-situ ellipsometry를 사용한 광기록매체용 Ge-Sb-Te 다층박막성장의 실시간 제어)

  • 김종혁;이학철;김상준;김상열;안성혁;원영희
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.3
    • /
    • pp.215-222
    • /
    • 2002
  • Using an in-situ ellipsometer, we monitored the growth curve of optical recording media in real time. For confirmation of the thickness control using in-situ ellipsometry, we analyzed the deposited multi-layer sample made of Ge-Sb-Te alloy film and ZnS-Si0$_2$ dielectric films using an exsitu spectroscopic ellipsometer. The target material in the first sputtering gun is ZnS-SiO$_2$ as the protecting dielectric layer and that in the second gun is Ge$_2$sb$_2$Te$_{5}$ as the receding layer. While depositing ZnS-SiO$_2$, Ge$_2$Sb$_2$Te$_{5}$ and ZnS-SiO$_2$ films on c-Si substrate in sequence, we measured Ψ $\Delta$ in real time. Utilizing the complex refractive indices of Ge$_2$Sb$_2$Te$_{5}$ and ZnS-SiO$_2$ obtained from the analysis of spectroscopic ellipsometry data, the evolution of ellipsometric constants Ψ, $\Delta$ with thickness is calculated. By comparing the calculated evolution curve of ellipsometric constants with the measured one, and by analyzing the effect of density variation of the Ge$_2$Sb$_2$Te$_{5}$ recording layer on ellipsometric constants with thickness, we precisely monitored the growth rate of the Ge-Sb-Te multilayer and controlled the growth process. The deviation of the real thicknesses of Ge-Sb-Te multilayer obtained under the strict monitoring is post confirmed to be less than 1.5% from the target structure of ZnS-SiO$_2$(1400 $\AA$)IGST(200 $\AA$)$\mid$ZnS-SiO$_2$(200$\AA$).(200$\AA$).

Effectiveness of Education Program Using Video Recording and Feedback on Skill Competency for Students of Majors in Health Care: A Meta-Analysis (동영상 촬영과 피드백을 이용한 실습교육이 보건의료전공 대학생의 술기수행능력에 미치는 효과: 메타분석)

  • Shin, Yun Hee;Kim, Sun Kyung;Kim, Hyunjoo
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.25 no.2
    • /
    • pp.120-133
    • /
    • 2018
  • Purpose: A meta-analysis was conducted to evaluate effectiveness of education programs using video recording and feedback in the improvement of competency in clinical skills for health care majors. Methods: Six databases were searched and inclusion criteria were randomized controlled trials (RCTs) or non-randomized controlled trials (NRTs) reporting level of skill competency using numerical measurements. Data analysis and synthesis were performed using Comprehensive Meta-Analysis software and Revman program. Results: Of 1,568 records, 11 studies met inclusion criteria. Statistically significant effectiveness of education programs using video recording and feedback was identified. A low risk of bias was detected among both RCTs and NRTs. Meta-analysis showed that the intervention groups had more effective improvements in skill competency (standardized mean difference [SMD]: 0.74; 95% CI: 0.33~1.16). Results of subgroup analysis showed higher effects when interventions dealt with one skill, used self-reflection with expert feedback, and included instruction from instructor in the education programs. Conclusion: Findings suggest that schools for health care majors should actively adopt video and feedback based skill training allowing educators to design effective programs. Potential is higher for students to achieve higher competency when they train with one skill at a time, use of instruction and receive feedback from experts.

Effects of Class Design using Automatic Recording System on Program Outcomes of Pediatric Nursing (강의자동녹화시스템을 사용한 수업설계가 아동간호학 학습성과에 미치는 영향)

  • Ahn, Sung-Yun
    • Journal of Industrial Convergence
    • /
    • v.17 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • The purpose of this study is to confirm the effects of the contents of the recording lectures through the automatic recording system of the nursing students on the program outcomes of the pediatric nursing. The study was designed using a nonequivalent control group pretest-posttest design. the subject of this study consisted of 104 nursing students(the experimental group of 52 and the control group of 52). Data were analyzed by ${\chi}^2$ test and independent t-test using SPSS 22.0. The effect of the first program outcome(PO1. We can integrate nursing skills based on various the liberal arts and the major knowledge into practice) of the experimental group was not confirmed, but the fifth program outcome(PO5. We can apply critical thinking based nursing processes and implement clinical inferences) was significantly higher than that of the control group. It is significant that this study presented the data to develop the class design method to improve the program outcomes of the nursing student at the present time which is operating the program outcomes based curriculum for nurse with core competency.

Present and Prospect of Ocean Observation Using Pressure-recording Inverted Echo Sounder (PIES) (압력측정 전도음향측심기(PIES)를 활용한 해양관측의 현재와 전망)

  • CHANHYUNG JEON;KANG-NYEONG LEE;HAJIN SONG;JEONG-YEOB CHAE;JAE-HUN PARK
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.28 no.1
    • /
    • pp.51-61
    • /
    • 2023
  • Sound can travel a long distance in the ocean; hence, acoustic instruments have been widely used for ocean observations in various fields such as bathymetric survey, object detection, underwater communication, and current measurements. Herein we introduce a pressure-recording inverted echo sounder (PIES) which is one of the most powerful instruments, moored at seafloor for ocean observation in physical oceanography. The PIES can measure various kinds of oceanic phenomena (currents, mesoscale eddies, internal waves, and sea surface height variabilities) and support acoustic telemetry and pop-up data shuttle (PDS) system for remote data acquisition. In this paper, we review uses of PIES and describe present and prospective system of PIES including remote data acquisition toward (quasi) real-time data recovery.

Methanol Extract of Longanae Arillus Regulates Sleep Architecture and EEG Power Spectra in Restraint-Stressed Rats

  • Ma, Yuan;Eun, Jae-Soon;Lee, Kwang-Seung;Lee, Eun-Sil;Kim, Chung-Soo;Hwang, Bang-Yeon;Oh, Ki-Wan
    • Natural Product Sciences
    • /
    • v.15 no.4
    • /
    • pp.213-221
    • /
    • 2009
  • Longanae Arillus (the rind of fruits of Dimocarpus longan) has been consumed for the treatment of insomnia and anxiety in Asia. To provide further scientific basis to traditional uses of this fruit on insomnia, we evaluated the effects of methanol extract of Longanae Arillus (MELA) on the alteration of sleep architecture and electroencephalogram (EEG) power spectra in acutely and chronically restraint-stressed rats. Following postsurgical recovery, Polygraphic signs of sleep-wake activities were recorded for 24 h after MELA administration in rats. Rats in the acute stress and chronic stress were administered with MELA for 10 days. On the $8^{th},\;9^{th}\;and\;10^{th}$ day of MELA administration, the rats were stressed for 3 h once per day. On the $10^{th}$ day and 1 h after MELA administration, the rats were stressed once for 22 h in the chronic stress group. Acute and chronic stress induced alternations in cortex EEG recordings during non-rapid eye movement (NREM), rapid eye movement (REM) sleep and wakefulness. MELA shortened the total and REM sleep and increased the wakefulness in night time recording without changing daytime recordings. Chronic stress increased wakefulness and REM sleep, decreased total and NREM sleep in the daytime recording, and increased REM and decreased NREM sleep without changing total sleep and wakefulness in night time recording. These findings suggest that MELA ameliorated the alterations in REM and NREM sleep of acutely and chronically stressed rats via modulation of cortical ${\alpha}-$, ${\theta}-$ and ${\delta}-$ wave activity.