• Title/Summary/Keyword: time-interval signal

Search Result 302, Processing Time 0.029 seconds

Power Spectral Density of Antipodal Ultra Wideband Signal (Antipodal 초광대역(UWB) 신호의 전력 스펙트럼 밀도 분석)

  • Kim, Jong Han;Lee, Jung Suk;Kim, Yoo Chang;Kim, Won Hoo;Kim, Jung Sun
    • Journal of Advanced Navigation Technology
    • /
    • v.5 no.1
    • /
    • pp.54-61
    • /
    • 2001
  • In conventional Ultra Wide Band(UWB) system, it uses Pulse Positioning Modulation Method to modulate data signal. In this paper, however, we derive power spectral density characteristic of time hopped antipodal signal using stochastic process. UWB signal employes Gaussian monopulse and Rayleigh monopulse which pulse width is 0.5 nsec and interval is 5 nsec. But comb line which produces unintentionally could be evidently reduced by the time hopped code, so this code be used to channelize for multiple access and minimize to different communication system.

  • PDF

A Study on the Cutting Tool Wear by Time Series Approach (시계열분석 방법 에 의한 절삭공구 의 마멸 에 관한 연구)

  • 김광준;황홍연
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.8 no.5
    • /
    • pp.450-461
    • /
    • 1984
  • A new indirect tool wear sensing technique is proposed using time series analysis. The acceleration measured on the tool post in the vertical direction during turning is sampled with uniform interval, and fitted following the ARMA modeling procedures. Various signal characteristics are observed in respect with the progress of flank wear. From those observations it is believed that; *The variance of the signal is approximately proportional to the increase of flank wear. *The absolute power of a dynamic mode decreases in the beginning of cutting until the maximum flank wear increases up to 0.4-0.5mm, and then increases. *The other characteristics are not so much related to the tool wear as the signal variance and the absolute power of a dynamic mode. Hence, the absolute power of a dynamic mode seems to be a good factor for the indication of tool-change time regardless of tool material or cutting conditions.

Direct blast detection algorithm for asynchronous bistatic sonar systems (비동기 양상태 소나 시스템을 위한 직접파 탐지 기법)

  • Jeong, Euicheol;Ahn, Jae-Kyun;Kim, Juho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.3
    • /
    • pp.139-146
    • /
    • 2018
  • Monostatic sonar systems localize targets using the time information of pulse transmission and receipt. Whereas, in asynchronous bistatic sonar systems, receivers need to detect direct blast to localize targets, since a source doesn't share pulse information with receivers. In this paper, we propose a direct blast detection algorithm, which estimates PRI (Pulse Repetition Interval) of direct blast and adaptive thresholds. Experimental results show the proposed algorithm has robust direct blast detection performance in the environment where strong background noise and target signal exist.

A Study in Seismic Signal Analysis for the First Arrival Picking (초동발췌를 위한 탄성파 신호분석연구)

  • Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.2
    • /
    • pp.131-137
    • /
    • 2007
  • With consideration of the first arrival picking methodology and inherent errors in picking process, I propose, from the computerization point of view, a practical algorithm for picking and error computation. The proposed picking procedure consists of 2-step; 1) picking the first coherent peak or trough events, 2) derive a line which approximates the record in the interval prior to the pick, and set the intercept time of the line as the first break. The length of fitting interval used in experiment, is few samples less than 1/4 width of the arriving wavelet. A quantitative measure of the error involved in first arrival picking is defined as the time length that needed to determine if an event is the first arrival or not. The time length is expressed as a function of frequency bandwidth of the signal and the S/N ratio. For 3 sets of cross-well seismic data, first breaks are picked twice, by manually, and by the proposed method. And at the same time, the error bound for each trace is computed. Experiment results show that good performance of the proposed picking method, and the usefulness of the quantitative error measure in pick-quality evaluation.

The decision of position of a partial discharge in power transformer by measurement of ultra sonic signal (초음파 신호측정에 의한 변압기내의 부분방전위치측정)

  • 문영재
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1992.06a
    • /
    • pp.87-90
    • /
    • 1992
  • Detecting acoustic emission (AE) provides an appropriate method to diagonize on-line transformers, since acoustic signal is not influenced by strong electric field. Then AE versus AE signal processing method is investigated. But this processing is difficult that decision of starting point of AE wave with acoustic noise. This problem is sloved by correlation which calculate time interval between two signals eactly. This paper presents a technique locating the eact position of the partial discharge (PD) in a power transformer by the correlation of the AE signals from two ultrasonic sensors. And PD position is displayed on monitor. Laboratory tests confirmed that the proposed method can be used for locating the PD in power transformer.

  • PDF

High Repetitive Pulsed Power Supply Based on Semi-Conductor Switches (반도체 스위치 기반 고반복 펄스전원)

  • Jang, S.R.;Ahn, S.H.;Ryoo, H.J.;Kim, J.S.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1023_1024
    • /
    • 2009
  • In this paper, a novel 10kV, 50A, 50kHz pulsed power supply based on IGBT stacks is proposed. Proposed scheme consists of series connected 12 IGBT to generate maximum 10kV output pulse and 10kW full bridge phase-shifted zero voltage switching converter to charge DC capacitor voltage. Each IGBTs are sustain the 830V of capacitor voltage at turn off interval. By turn on the each IGBT for the same time it gives the path for the series connection of charged capacitor. From above turn on and off procedure, high voltage repetitive pulse is applied to the load. The synchronization of gating signal is important of series operation of IGBTs. For gating signal synchronization, specially designed gate power circuit using full bridge inverter and pulse transformer is developed to generate IGBT gating signal.

  • PDF

A Study on the Quantitative Regularity Measures That Are Suitable for Biological Signal Analysis - Standard Data and 24 Hour R-R interval Analysis

  • Nam, Y.H.;Lee, J.M.;Han, J.M.;Park, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.197-198
    • /
    • 1998
  • We tested the capability of Pointwise Correlation Dimension(PD2), Approximate Entropy (ApEn) and LZ complexity, as alternative measures of a biological signal. For this purpose, we analyzed standard data and a healthy child's 24-hour heart rate variability. Our conclusion is as follows. First, PD2, ApEn and LZ complexity can be used for discerning chaotic attractor, white noise, and periodic signal. Second, these measures show different characteristics on day and night. Third, these measures can be used for detecting time-varying characteristics of biological signals.

  • PDF

An Analysis of Highlight Distribution Modeling for High Frequency CW Pulse Signal Reflection on Underwater Target (수중표적의 고주파수 CW 펄스신호 반사를 위한 하이라이트 분포 모델링 해석)

  • 김부일;이형욱;박명호;권우현
    • Journal of the Korea Society for Simulation
    • /
    • v.9 no.3
    • /
    • pp.1-11
    • /
    • 2000
  • This paper proposes the practical echo-signal synthesis models - UTAHID (Underwater TArget by Highlight Distribution) & M-UTAHID(Modified UTAHID) - of underwater target for active sonar engineering At high frequencies all the echo components that are the specular reflected waves and various elastic scattering wave scan be regarded the summation of individual echo from some equivalent scattering centers, so the underwater target is characterized by highlights distributed in spatial target structure. Proposed models are compared with characteristics of random distributed model & equivalent interval highlight model, and analyzed target strength, echo-elongation effect, target time spread loss and so on. Thus these can be efficiently used in various real systems related to underwater target echo-signal synthesis on active sonar and acoustic countermeasure.

  • PDF

Comparison of Small Signal Stability Analysis Methods in Complex Systems with Switching Elements

  • Kim, Deok Young;Meliiopoulos, A.P.Sakis
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.2
    • /
    • pp.79-83
    • /
    • 2004
  • A new small signal stability analysis method for eigenvalue analysis is presented. This method utilizes the Resistive Companion Form (RCF) for the computation of the transition matrix over a specified time interval, which corresponds to a single cycle operation of the system. This method is applicable to any system, with or without switching element. An illustrative example of the method is presented and the eigenvalues are compared with those of the conventional state space method (analog) in order to demonstrate the accuracy of the proposed eigenvalue analysis method. Also, the variations of oscillation modes that are caused by the switching operation can be precisely analyzed using this method.

Performance Improvement on the Combined Convolutional Coding and Binary CPFSK Modulation (Convolutional Code/Binary CPFSK 복합 전송시스템의 성능개선에 관한 연구)

  • Choi, Yang Ho;Baek, Je In;Kim, Jae Kyoon
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.5
    • /
    • pp.591-596
    • /
    • 1986
  • A binary continuous phase frequency shift keying (CPFSK), whose phase is a continuous function of time and instantaneous frequency is constant, is a bandwidth efficient constant envelope signalling scheme. A transmitting signal is formed by combined coding of a convolutional encoder and a binary CPFSK modulator. The signal is transmitted throuth additive white Gaussian noise(AWGN) channel. If the received signal is detected by a coherent maximum likelihood(ML) receiver, error probability can be expressed approximately in terms of minimum Euclidean distance. We propose rate 2/4 codes for the improvement of error performance without increating the data rate per bandwidth and the receiver complexity. Its minimum Euclidean distances are compared with those of rate \ulcornercodes as a function of modulation index and observation interval.

  • PDF