• Title/Summary/Keyword: time reversible

Search Result 220, Processing Time 0.029 seconds

MCMC Particle Filter based Multiple Preceeding Vehicle Tracking System for Intelligent Vehicle (MCMC 기반 파티클 필터를 이용한 지능형 자동차의 다수 전방 차량 추적 시스템)

  • Choi, Baehoon;An, Jhonghyun;Cho, Minho;Kim, Euntai
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.2
    • /
    • pp.186-190
    • /
    • 2015
  • Intelligent vehicle plans motion and navigate itself based on the surrounding environment perception. Hence, the precise environment recognition is an essential part of self-driving vehicle. There exist many vulnerable road users (e.g. vehicle, pedestrians) on vehicular driving environment, the vehicle must percept all the dynamic obstacles accurately for safety. In this paper, we propose an multiple vehicle tracking algorithm using microwave radar. Our proposed system includes various special features. First, exceptional radar measurement model for vehicle, concentrated on the corner, is described by mixture density network (MDN), and applied to particle filter weighting. Also, to conquer the curse of dimensionality of particle filter and estimate the time-varying number of multi-target states, reversible jump markov chain monte carlo (RJMCMC) is used to sampling step of the proposed algorithm. The robustness of the proposed algorithm is demonstrated through several computer simulations.

Electrochemical Studies of Immobilized Laccases on the Modified-Gold Electrodes

  • Yoon Chang-Jung;Kim Hyug-Han
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.1
    • /
    • pp.26-31
    • /
    • 2004
  • The direct electrochemical studies of four laccases (plant and fungal laccases) have been investigated on a gold electrode functionalized with a new tether of 2.2'-dithiosalicylic aldehyde. Results from these studies indicate that the redox potential of the active site of plant laccase from Rhus vernificera is shifted to a more negative value(255 mV versus SCE) than that of fungal laccase from Pyricularia oryzae (480 mV versus SCE). Mechanistic studies indicate that the reduction of type-1 Cu precedes the reduction of type-2 and type-3 Cu ions when the electrode is poised initially at different potentials. Also a new tether, 2.2'-dithiosalicylic aldehyde, has been used to study the redox properties of two laccases (LCCI and Lccla) covalently attached to a gold electrode. An irreversible peak at 0.47V vs. SCE is observed in the cyclic voltammorams of LCCI. In contrast, the cyclic voltammograms of LCCIa contain a quasi-reversible peak at 0.18V vs. SCE and an irreversible peak at 0.50V vs. SCE. We find that the replacement of the eleven amino acids a the C-terminus with a single cysteine residue $(i.e., \;LCCI{\rightarrow}LCCIa)$ influences the rate of heterogeneous electron transfer between an electrode and the copper containing active sites $(K_{het}\;for\;LCCI=1.0\times10^{-2}\;s^{-1}\;and\;K_{het}\;for\;LCCI_a= 1.0\;times10^{-1}\;s^{-1}\'at\;0.18V\;versus\;SCE\;and\;4.0\times10^{-2}\;s^{-1}\;at\;0.50V\; versus\;SCE)$. These results show for the first time that the change of the primary structure of a protein via site-directed mutagenesis influences both the redox potentials of the copper ions in the active site and the rate of heterogeneous electron transfer.

Porous silicon-based chemical and biosensors (다공질 실리콘 구조를 이용한 화학 및 바이오 센서)

  • Kim, Yun-Ho;Park, Eun-Jin;Choi, Woo-Seok;Hong, Suk-In;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2410-2412
    • /
    • 2005
  • In this study, two types of PS substrate were fabricated for sensing of chemical and biological substances. For sensing of the humidity and chemical analyzes such as $CH_3OH$ or $C_2H_5OH$, PS layers are prepared by photoelectrochemical etching of silicon wafer in aqueous hydrofluoric acid solution. To evaluate their sensitivity, we measured the resistance variation of the PS diaphragm. As the amplitude of applied voltage increases from 2 to 6Vpp at constant frequency of 5kHz, the resistance variation for humidity sensor rises from 376.3 to $784.8{\Omega}$/%RH. And the sensitivities for $CH_3OH$ and $C_2H_5OH$ were 0.068 uA/% and 0.212 uA/%, respectively. For biological sensing application, amperometric urea sensors were fabricated based on porous silicon(PS), and planar silicon(PLS) electrode substrates by the electrochemical methods. Pt thin film was sputtered on these substrates which were previously formed by electrochemical anodization. Poly (3-methylthiophene) (P3MT) were used for electron transfer matrix between urease(Urs) and the electrode phase, and Urs also was by electrochemically immobilized. Effective working area of these electrodes was determined for the first time by using $Fe(CN)_6^{3-}/Fe(CN)_6^{4-}$ redox couple in which nearly reversible cyclic voltammograms were obtained. The $i_p$ vs $v^{1/2}$ plots show that effective working electrode area of the PS-based Pt thin film electrode was 1.6 times larger than the PLS-based one and we can readily expect the enlarged surface area of PS electrode would result in increased sensitivity by ca. 1.6 times. Actually, amperometric sensitivity of the Urs/P3MT/Pt/PS electrode was ca 0.91uA/$mM{\cdot}cm^2$, and that of the Urs/P3MT/Pt/PLS electrode was ca. 0.91uA/$mM{\cdot}cm^2$ in a linear range of 1mmol/L to 100mmol/L urea concentrations

  • PDF

Effect of $Na^+$ Removal on the Action of Ethanol in Cat Ileal Longitudinal Muscle (장관 평활근에서 Na-free용액이 Ethanol의 효과에 미치는 영향)

  • Suh, Duk-Jun;Kim, So-Sun;Woo, Jae-Suk;Kim, Young-Keun
    • The Korean Journal of Physiology
    • /
    • v.20 no.1
    • /
    • pp.125-133
    • /
    • 1986
  • The effect of ethanol on the contraction of intestinal smooth muscle in Na-free solution was studied using cat ileal longitudinal muscle strips. Ethanol $(0.5{\pm}4%)$ inhibited both the spontaneous mechanical activity and base-line tension in normal physiological salt solution. However, in Na-free solution it induced a reversible contraction. The excitatory effect by ethanol in Na-free solution was increased with increasing the concentrations of ethanol and the time incubated in Na-free solution. The excitatory response by ethanol was reduced by increasing the concentrations of Na in incubated medium . Ethanol-induced contractile response was not affected by $Ca^{2+}$ removal in bathing medium. In Na-free solution, the contraction by ethanol was inhibited by Las. but was not affected by verapamil. The contraction induced by Na removal in solution was inhibited by the pretreatment of ethanol. These results suggest that ethanol may induce the contraction by increasing the release of superficially membrane-bound $Ca^{2+}$ and/or intracellular $Ca^{2+}$ in Na-free physiological salt solution.

  • PDF

Motility and Absorptive Capacity of the Ileum in Acute Hemorrhage (급성실혈시의 회장운동과 흡수기능)

  • Hwang, Jeong-Woon
    • The Korean Journal of Physiology
    • /
    • v.7 no.2
    • /
    • pp.39-47
    • /
    • 1973
  • The influences of the acute hemorrhage on the intestinal functions were studied in the rabbits subjected to acute bleeding, amounting 1.5-2% of the body weight. The motility and the absorptive capacity of the ileum were compared before and after the bleeding. Transfusion of shed blood was also performed in order to see whether the deteriorations were reversible or not. The tension developed in the direction of the longitudinal axis of the ileum was recorded through an appropriate transducer, and the frequency of the rhythmic contraction was counted throughout the procedure. Test solution, 10ml in amount, was placed in the loop of the ileum, and the samples were drawn at zero time and at 20 minutes. Triplicated procedures were repeated on the same loop;namely, before and after bleeding and after transfusion. The test solution was composed of 200 mg% urea, 218 mEq/l of NaCl and 150 mg% of polyethylene glycol (PEG) No. 4,000 in distilled water. The latter substance was used as a marker substance for the volume change of the loop. The results obtained were as follows; 1. The motility of the ileum suffered little effects by acute hemorrhage. However, minor fluctuations were seen in the frequency of the rhythm, showing a slight tendency of decreasing rhythmicity, and it was reversed by transfusion. 2. Diminution of absorptive capacity of urea was noticed in acute hemorrhage and it was interpreted as the consequence of the secondary effect of the retardation of the active transport mechanism governing the sodium transport 3. Absorption rate of the sodium ion was dropped in the hemorrhage, suggesting the indispensable need of the blood supply. 4. Osmolarity of the luminal fluid remained higher in the case of acute hemorrhage. 5. There was a tendency of retaining more fluid in the intestinal lumen in acute hemorrhage, comparing with that observed prior to the bleeding. 6. The deteriorations in the absorptive capacity were restored by transfusion of shed blood.

  • PDF

Sensitivity of BOD Sensor with Heavy Metal Tolerant Serratia marcescens LSY4 (Serratia marcescens LSY4 중금속 내성주를 이용한 BOD센서의 감응도)

  • Kim Mal-Nam;Lee Sun-Young
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.394-399
    • /
    • 2004
  • A BOD sensor was prepared with S. marcescens LSY4 and was applied for measurement of BOD values of a solution containing the standard organic pollutants. The sensor sensitivity was nearly independent of the culture time in the range of 9-16 hours. It was also affected little by the cell mass in the range of 0.22-0.75 mg $cm^{-2}$. A cyclic change in the solution pH in the range of 4-9 was accompanied by a reversible variation in the sensor sensitivity. However, the reversibility was lost when the solution pH became more acidic or more basic. Heavy metal ions lowered the sensor sensitivity, which took place more precipitously in the presence of $Cu^{2+}$ and $Ag^+$ rather than in the presence of $Zn^{2+}$ and $Cd^{2+}$. The reduction of the sensor sensitivity was significantly attenuated by loading heavy metal ion tolerance induced strain. The $Cu^{2+}$tolerance induced strain was more efficient for the attenuation than $Zn^{2+}$ and $Cd^{2+}$ tolerance induced strain.

Changes of Afferent Transmission to the SI Cortex by Transient Co-Stimulation of Receptive Field Center and Outside in Anesthetized Rats

  • Yang, Yu-Mi;Lim, Sa-Bina;Won, Chung-Kil;Shin, Hyung-Cheul
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.5 no.1
    • /
    • pp.27-32
    • /
    • 2001
  • We have characterized the aftereffects of impulse activities on the transmission of afferent sensory to the primary somatosensory (SI) cortex of the anesthetized rats (n=22). Following conditioning stimulation (CS, 10 sec, either 5 Hz or 200 Hz) to the receptive field (RF), quantitative determination of the changes of afferent sensory transmission was done by generating post-stimulus time histogram of unit response to the testing stimulation (TS, at 0.5 Hz) to the RF center (RFC) for 60 min. In one group of experiments, CS was delivered to the RF center (RFC). In another group of experiments, CSs were simultaneously given to both RFC and RF outside (RFO, either forepaw or hindpaw). CS of 5 Hz to RFC exerted irreversible facilitation of sensory transmissions evoked by TS. Simultaneous CSs of 5 Hz to RFC and hindpaw RFO exerted reversible suppression of afferent transmission. However, CSs of 5 Hz to RFC and forepaw RFO did not significantly altered afferent sensory transmission to SI cortex neurons. CS of 200 Hz to RFC exerted irreversible suppression of sensory transmissions up to 60 min of experimental period. Simultaneous CSs of 200 Hz to RFC and RFO did not significantly altered afferent sensory transmission to SI cortex neurons. The profiles of CS-induced modulation of afferent sensory transmission were significantly different between two CS conditions. Thus, this study suggests that activity-dependent modulation of afferent transmission from a RF center to the SI cortex may be significantly altered when remote body part was simultaneously activated.

  • PDF

Effect of pH on the Stability of Green tea Catechins (녹차 카테킨류의 pH에 대한 안정성 연구)

  • 박영현;원은경;손동주
    • Journal of Food Hygiene and Safety
    • /
    • v.17 no.3
    • /
    • pp.117-123
    • /
    • 2002
  • The five main green tea catechin components such as (+)-catechin, (-)-epicatechin, (-)-epigallocatechin, (-)-epicatechin gallate, and (-)-epigallocatechin gallate were analyzed quantitatively from commercial green tea by HPLC. Amounts of catechins decreased in the following order : (+)-catechin > (-)-epigallocatechin gallate >(-)-epigallocatechin >(-)-epicatechin >(-)-epicatechin gallate. In this study, the stability of the following green tea catechins to pH in the range from 3 to 11 was studied using of ultraviolet spectroscopy : (+)-catechin, (-)-epicatechin, (-)-epicatechin gallate, and (-)-epigallocatechin gallate. This study demonstrated that green tea catechins were not stable at high pH and that the pH-, and time-dependent spectral alternatives were not reversible In conclusion, low pH is important to maintain the efficient utilization of green tea catechins.

A Study on the Reversible SCR Servo Amplifier (정역전이 가능한 SCR 서보증폭기에 관한 연구)

  • Ahn, B. W.;Park, S. K.
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.2
    • /
    • pp.190-198
    • /
    • 1995
  • Many industrial servo amplifiers employ power transister as output device. Thyristor converters are not adopted to drive servo motor, although thyristor is superior to power TR in power rating, noise immunity, price, and size. The reason is, thyristor has no ability of self turn - off. Here in this paper line commutation, in which thyristor is turned off naturally since cathode voltage is higher than anode as time goes by, is employed to turn on thyristor with a delicate sequence. We developed thyristor servo amplifier which does not cause any damage on thyristor because it is designed to prevent triggering the two SCRs in the same arm simultaneously. And it was made clearly how to trigger SCR without any power line shorting and also harmonic analysis is carried out with the aid of FFT analyzer and proved that it can be used even severe reactive load. The designed circuit operated as a good DC amplifier in conventinal servomotor and the results can be use as a position control system application.

  • PDF

THE EFFECT OF CARBAMIDE PEROXIDE BLEACHING GEL ON DENTAL PULP AND PERIODONTAL TISSUE IN RATS (백서에서 Carbamide peroxide bleaching gel이 치수 및 치주조직에 미치는 영향)

  • Kim, Sun-Ho;Hwang, In-Nam;Kim, Min-Seok;Kim, Sun-Hun;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.2
    • /
    • pp.289-298
    • /
    • 2000
  • Carbamide peroxide is usually used for vital teeth bleaching at home. Complications such as tooth hypersensitivity and/or gingival irritation are frequently reported. Therefore, this study was performed to evaluate any possible histological changes in pulp and periodontal tissue by carbamide peroxide bleaching gel in rats. 10% and 15% carbamide peroxide containing nightguard for upper molar were worn for 4 hours a day. The rats were sacrificed after 1 day, 2 days, 3 days, 4 days and 6 days application of carbamide peroxide respectively. The results were as follows : Mild infiltration of inflammatory changes below the junctional epithelium and hyperplasia of epithelium were observed in both 10% and 15% carbamide peroxide treated groups. In all experimental groups, odontoblasts were changed from columnar to cuboidal shape and/or obliterated and the focal loss of predentin was observed in pulp horn. With increasing time of application, these changes were more remarkable, but limited in pulp horn. Inflammatory reactions, vacuolar changes and hyaline degenerations of the pup tissue were also observed in some cases. These results suggested that carbamide peroxide gel used in home bleaching could cause reversible pulpal irritation.

  • PDF