• Title/Summary/Keyword: tilting motion

Search Result 132, Processing Time 0.02 seconds

Development of a Ultrasound Probe for 3-D Ultrasonic Imaging (3차원 의료기기용 초음파진단기 프로브 개발)

  • Park, Jong-Soo;Kim, Seong-Rae;Nam, Yoon-Su
    • Journal of Industrial Technology
    • /
    • v.25 no.A
    • /
    • pp.87-93
    • /
    • 2005
  • Three-dimensional ultrasonic probes being applied to the medical imaging can be grouped into three depending on the scanning methods, which are a mechanical type system, a free-hand system, and 2D phased arrays system. A mechanical type scanner uses a mechanically driven transducer to acquire series of 2D plane images. By integrating these images, a 3-D medical image can be constructed. A motor driving mechanism is a conventional choice for mechanically driving a transducer assembly which picks the raw ultrasonic images up. In this paper we attempt to design a 3D ultrasonic probe which has a operating mechanism of s tilting 3-D scanning. The motion of a transducer assembly of the ultrasonic probe is analytically modelled. We propose a selection procedure for the diameter of a wire rope driving the transducer assembly and the size of torsional spring which gives an initial tension to wire ropes.

  • PDF

A Kinematic Analysis on Piston Rod Mechanism in Swashplate Type Hydraulic Axial Piston Motor/Pump Using Constant Velocity Joint (등속조인트를 적용한 사판식 유압 모터/점프의 로드형 피스톤에 대한 운동해석)

  • Kim K.H.;Kim S.D.;Ham Y.B.;Lee J.C.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Recently, swash plate type hydraulic axial piston motors/pumps are being extensively used in the world, because of simple design, light weight and effective cost. Structural problem of the swash plate type motor/pump is that tilting angle of swash plate should be limited to relatively small value and lateral farce on pistons has an undesirable effect in reciprocating motion. To solve these problems, piston rod mechanism, which is commonly used in bent axis type motor/pump, is considered to be applied to the swash plate type motor/pump. In this paper, kinematic analysis was done on the piston rod mechanism. A series of formula were derived and numerical calculations were done for a set of motor parameters.

  • PDF

Numerical Study of Tunnel Hood to Reduce Micro-Pressure Wave on Conventional Railways (기존선 터널 출구 미기압파 저감을 위한 터널 후드의 수치 해석적 연구)

  • Kim Byeong-Yeol;Kwon Hyeok-Bin;Yun Su-Hwan;Ku Yo-Cheon;Ko Tae-Hwan;Lee Dong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.6 s.31
    • /
    • pp.513-519
    • /
    • 2005
  • The Korean Tilting Train eXpress may produced a strong micro-pressure wave in tunnel exit because of large train/tunnel area ration of conventional railways. This micro-pressure wave causes an impulsive noise which is a serious environmental noise pollution near tunnel exit. Tunnel hood can be the method of reducing the micro-pressure wave in tunnel exit. Therefore, parametric studies for tunnel hood are performed with respect to the hood length and size to investigate the effects of the tunnel hood. Also, axi-symmetric unsteady compressible flow solver was used to analyze train-tunnel relative motion. According to the result of numerical analysis, the maximum micro-pressure wave in tunnel exit is reduced by 56% throughout the hood establishment on conventional railways.

PS-LAP : Piston Skirt Lubrication Analysis Program (PS-LAP : 피스톤 통합 해석 프로그램)

  • 김지영;김지운;조명래;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.253-257
    • /
    • 2000
  • This paper reports on the development of the analysis program of the piston skirt system, PS-LAP. It is essential to verify the stability of the design and to improve the performance of the system. In order to do that efficiently, it is required that integrated and interactive simulation analysis program. PS-LAP is developed in the base of the object-oriented, capsulation, modulization, OLE(objected linking and embedding) and variational design theory. So it contain the expandability and flexibility of the structure. In addition to that, it is programed to make the convenient user interface by using the visualization programming. It can support the modification of the piston skirt shape, lubrication condition and so on. It is expected to reduce the money and effort for design the piston skirt system.

  • PDF

Micromachined Mercury Drop Tilt Sensor (MEMS 기술을 이용한 수은방울경사각센서 개발)

  • Oh, Jong-Hyun;Oh, Dong-Young;Lee, Seung S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.8
    • /
    • pp.120-125
    • /
    • 2000
  • This paper proposes a tilt sensor made by MEMS technology. The sensor consists of an electrode glass a small mercury drop a circular channel and a cover glass. The mercury drop is used as medium of a current flow and in contact with two circular chromel electrodes used as an angular-motion resistance When this sensor inclines the mercury drop inside the circular channel moves into the bottom under the influence of gravity. A tilt angle can be measured by changed resistance as tilting this sensor, This sensor has a linear section between +50.$^{\circ}$ and -50.$^{\circ}$ with the accuracy of 2.$^{\circ}$. We are also studying about the enlargement of the linear section and the effect of the size of the mercury drop.

  • PDF

A Study of Dynamic Balance Control between Golfer and Non-golfer (골프 선수와 일반 성인의 동적 균형 제어에 대한 연구)

  • Park, Jun-Sung;Lim, Young-Tae;Lee, Jae-Woo;Kwon, Moon-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.2
    • /
    • pp.119-125
    • /
    • 2021
  • Objective: The purpose of this study was to identify the effect of dynamic postural balance control against tilting platform between golfers and non-golfers. Method: 24 golfers and 26 non-golfers were participated. Eight motion capture cameras, two force plates, and one dynamic balance control platform were used for sensory perception test. It was performed two-way repeated ANOVA with a Bonferroni adjustment at a significant level of a 0.05. Results: Golfers' perception ability was higher than non-golfer according to slope. the CoP, time, angle variables were indicated main effect and interaction effect between golfer and non-golfer. Conclusion: It was known that golfer's proprioception perception ability was higher than non-golfers. Repeated practice such as shots and putting on the uneven ground might improve their balance control.

A Numerical Study on Hydrodynamic Interactions between Dynamic Positioning Thrusters (동적위치제어용 스러스터 사이의 유체역학적 상호작용에 대한 수치해석 연구)

  • Jin, Doo Hwa;Lee, Sang Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.6
    • /
    • pp.373-380
    • /
    • 2017
  • In this study, we conducted computational fluid dynamics (CFD) simulations for the unsteady hydrodynamic interaction of multiple thrusters by solving Reynolds averaged Navier-Stokes equations. A commercial CFD software, STAR-CCM+ was used for all simulations by employing a ducted thruster model with combination of a propeller and No. 19a duct. A sliding mesh technique was used to treat dynamic motion of propeller rotation and non-conformal hexahedral grid system was considered. Four different combinations in tilting and azimuth angles of the thrusters were considered to investigate the effects on the propulsion performance. We could find that thruster-hull and thruster-thruster interactions has significant effect on propulsion performance and further study will be required for the optimal configurations with the best tilting and relative azimuth angle between thrusters.

Development and Tree-Dimensional Kinematic Analysis of the Dual Chamber-based Drinking Aid for Stroke Patients: A Prospective Pilot Study (이중 체임버 구조가 내장된 뇌졸중 환자용 컵의 개발과 3차원 동작분석을 통한 운동 형상학적 유용성 검증: 전향적 예비연구)

  • Heo, Seo Yoon;Kim, Kyeong-Mi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.180-190
    • /
    • 2016
  • This prospective pilot clinical trial mainly focuses on developing dual chamber-based assistive cups which are suitable for stroke patients who have struggled with using there affected arms. It is unable to provide motor and sensory enhancement during drinking activities and to examine the feasibility of the devices for acute phase, even for chronic stroke survivors. The stroke patients(n=16; male=8, female=8), in this trial, were provided informed consent to the investigation. All the individuals participated in 1 weeks of training for using cups, randomized over dedicated dual chamber based assistive cups(DC) or placebo-cups(PC) training. All the participants were assessed within 1 week before and after the intervention period. 3-dimensional motion analysis, sEMG(surface electromyography) and 3-dimensional trunk movement were assessed. The result presents DC data group compared with PC showed, they needed lesser ROM(range of motion) at the phase of drinking in shoulder movements and lesser muscle activities on upper trapezius, deltoid middle fiber and triceps brachii muscles, lesser tilting movement on front and back side in drinking phase, the differences were statistically significant(p<.05). Dual chamber-based assistive cup could be one of efficient way to complete ADLs(activities of daily living), especially drinking tasks, and these evidence data may contribute to determine certain rehabilitation policies related to assistive devise usage.

Conical Path Generation Technique for Ball Bar Measurement Using Simultaneous 5-Axis Motion Control (5 축 동시 구동을 통한 볼바 측정용 원추형 경로 생성 방법)

  • Lee, Dong-Mok;Lee, Jae-Chang;Yang, Seung-Han
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.1
    • /
    • pp.97-103
    • /
    • 2013
  • This study proposes a path generation technique for simultaneous five-axis driving for ball bar measurement, which is equivalent to cone frustum machining as mentioned in the NAS979 standard. The technique is generalized for a 3D circular path, and it is applicable to all machine tools regardless of their structural configurations. A mathematical machine input model that consists of a five-axis machine tool, ball-bar measurement and conical path information as inputs is presented for easy NC code generation, simulation for various test conditions, and a measurement test. The movement range of rotary axes, which depends on various conditions, is mathematically analyzed based on the proposed conical path model. Moreover, the effect of the movement range on various conditions (apex angle and inclination angle, ball bar tilting acceptance angle, offset position of workpiece ball, etc.) is analyzed.

Effects of Therapeutic Exercise on Hip Joint Range of Motion, Manual Muscle Test, Functional Movement Screen and Radiological Evaluation in a Youth Football Player with Football-specific Anterior Pelvic Tilt: A Case Report (치료적 운동이 축구 특이적 골반 앞 기울임을 가진 유소년 축구선수 엉덩관절의 관절가동범위, 도수근력, 기능적 움직임 및 방사선학적 평가에 미치는 영향: 증례보고)

  • Yu, Dong-Hun;Seo, Sang-Won;Lee, Ho-Seong
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.4
    • /
    • pp.85-94
    • /
    • 2018
  • PURPOSE: This study was conducted to determine the effects of therapeutic exercise on range of motion (ROM), the manual muscle test (MMT), functional movement screen (FMS) and radiological evaluation in a youth football player with football-specific anterior pelvic tilt (APT). METHODS: The subject of this case report was a 12-year-old youth football player, who presented with football-specific APT. Therapeutic exercise consisted of hamstring stretch, prone hip extension, abdominal crunch, bridging with isometric hip abduction, plank exercise with posterior tilt and posterior pelvic tilting exercise using a swiss-ball for 40 min/day, twice a week for 8-weeks. ROM, MMT, FMS (deep squat, hurdle step, inline lunge, shoulder mobility, active straight-leg raise, rotary stability and trunk stability push-up) and radiographs (lumbar lordotic and sacral horizontal angle) were analyzed before and after week 8 of therapeutic exercise. RESULTS: The ROM, MMT, and FMS increased and the lumbar lordotic angle and sacral horizontal angle improved after 8-weeks of therapeutic exercise. CONCLUSION: The results of this case report suggest that therapeutic exercise improves ROM, MMT and radiography associated parameters in youth football players with football-specific APT. These findings have clinical implications for therapeutic exercise in youth football players with football-specific APT.