• 제목/요약/키워드: tilt-motion

Search Result 200, Processing Time 0.026 seconds

Improvement of Washout Algorithm for Vehicle Driving Simulator Using Vehicle Tilt Data and Its Evaluation (차량 기울기값을 이용한 차량 시a레이터용 워시아웃 알고리즘에 대한 개선 및 평가)

  • Moon, Young-Geun;Kim, Moon-Sik;Kim, Kyung-Dal;Lee, Min-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.8
    • /
    • pp.823-830
    • /
    • 2009
  • For developing automotive parts and telematics devices the real car test often shows limitation because it needs high cost, much time and has the possibility of the accident. Therefore, a Vehicle Driving Simulator (VDS) instead of the real-car test has been used by some automotive manufactures, research centers, and universities. The VDS is a virtual reality device which makes a human being feel as if one drives a vehicle actually. Unlike actual vehicle, the simulator has limited kinematic workspace and bounded dynamic characteristics. So it is difficult to simulate dynamic motions of a multi-body vehicle model fully. In order to overcome these problems, a washout algorithm which restricts workspace of the simulator within the kinematic limits is needed, and analysis of dynamic characteristics is required also. However, a classical washout algorithm contains several problems such as time delay and generation of wrong motion signal caused by characteristics of filters. Specially, the classical washout algorithm has the simulator sickness when driver hardly turns brakes and accelerates the VDS. In this paper, a new washout algorithm is developed to enhance the motion sensitivity and improve the simulator sickness by using the vehicle tilt signal which is generated in the real time vehicle dynamic model.

Real Time Speaker Close-Up System using The Lip Motion Informations (입술 움직임 정보를 이용한 실시간 화자 클로즈업 시스템 구현)

  • 권혁봉;장언동;윤태승;안재형
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.6
    • /
    • pp.510-517
    • /
    • 2001
  • In this paper, we implement a real time speaker close-up system using lip motion information from input images having some people. After detecting a speaker from input moving pictures through one color CCD camera, the other camera closes up the speaker by using lip motion information. The implemented system detects a face and lip area of each person by means of a facial color and a morphological information, and then finds out a speaker by using lip area variation. A PTZ(Pan/Tilt/Zoom) camera is used in order to close up the detected speaker and it is controlled by RS-232C serial port. Consequently, we can exactly detect a speaker in input moving pictures including more than three people.

  • PDF

Kinematic Characteristics during of Gait in Parkinson's Disease Patients (파킨슨 질환 환자의 보행시 운동형상학 특성)

  • You, Jae-Eung;An, Chang-Sik
    • The Journal of Korean Physical Therapy
    • /
    • v.13 no.2
    • /
    • pp.453-458
    • /
    • 2001
  • The aim of this study is to present the basic reference data of age and specific gait parameters for Parkinson's Disease Patients. The basic gait parameters were extracted from 5 patients, 5 men and 65 years of age using VICON 512 Motion Analyzer. The temporal gait parameters and kinematic parameters is data of Parkinson's Disease Patients. The results were as follows; 1. The cadence, velocity, stride length decreased and single limb support period, double limb support period increased than normal adult in the temporal parameters. 2. The mean angles of joint pelvic tilt and hip, knee, ankle joint decreased than normal adult at kinematic characteristics on sagittal plane. 3. The mean angles of joint pelvic tilt and hip, knee joint has no difference than normal adult at kinematic characteristics on coronal plane. 4. The mean angles of joint pelvic tilt, hip joint no difference and internal, external rotation in ankle joint significantly decreased than normal adult at kinematic characteristics on transverse plane.

  • PDF

A Study on the Analysis of 5-DOF Axis of Rotation Error in Low Speed Rotary Stage (저속 회전 스테이지의 5자유도 회전축 오차 분석에 관한 연구)

  • Han, Chang-Soo;Kim, Jin-Ho;Shin, Dong-Ik;Yun, Deok-Won;Lee, Yung-Gi;Lee, Sang-Moo;Nam, Gyung-Tai
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.23-27
    • /
    • 2007
  • Rotary stages in semiconductor, display industry and many other fields require challenging accuracy to perform their functions properly. Especially, Axis of rotation error on rotary system is significant; such as the spindle error motion of the aligner, wire bonder and inspector machine which result in the poor quality products. To evaluate and improve the performance of such precision rotary stage, undesired movements on the other 5 degrees of freedom of the rotary stage must be measured and analyzed. In this paper, we have measured the three translations and two tilt motions of the worm gear type spindle with high precision capacitive sensors. To obtain the radial error motion, we have used Donaldson's reversal technique. And the axial components of the spindle tilt error motion can be obtained accurately from the axial direction outputs of sensors by Estler face motion reversal technique. Further more we have designed and developed the sensor mounting jig with standard cylinder for reversal method.

  • PDF

Development of 3-axis Moving Magnet Type Actuator (가동 자석형 3 축 구동 엑츄에이터 개발)

  • Song, Myeong-Gyu;Hur, Young-Jun;Park, No-Cheol;Yoo, Jeong-Hoon;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.4
    • /
    • pp.191-195
    • /
    • 2007
  • The optical disc drive has used a high NA objective lens and a shorter wavelength laser diode for high recording density. But high NA and shorter wavelength cause several margins to become short. Focusing and tracking servo has to be more accurate and active tilt compensation mechanism is also needed for coma aberration compensation. In this paper, we proposed 3-axis moving magnet type actuator. For 3-DOF motion, moving coil actuator has to be equipped with 6 wires for supplying 3 independent signals. However, moving magnet type actuator doesn't need to change the configuration of wires because coils are in stator. So, we added a tilt mechanism to the 2-axis moving magnet actuator which is designed in previous research. Addition of the tilt mechanism cuts down the focus sensitivity. So, maximization the tilting sensitivity and securing the focusing sensitivity are objectivities of this research. DOE (design of experiments) procedures of electromagnetic circuit are performed for parameter study and the optimization is also performed to maximize the tilt sensitivity. And then the final design is suggested and its performance is verified by FE simulation.

  • PDF

Can Abdominal Drawing-In Maneuver Using a Pressure Biofeedback Unit Change Muscle Recruitment Pattern During Prone Hip Extension?

  • Oh, Jae-Seop;Weon, Jong-Hyuck;Cynn, Heon-Seock;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.13 no.4
    • /
    • pp.56-63
    • /
    • 2006
  • This study examined the effects of the abdominal drawing-in (ADI) maneuver using a pressure biofeedback on muscle recruitment pattern of erector spinae and hip extensors and anterior pelvic tilt during hip extension in the prone position. Fourteen able-bodied volunteers, who had no medical history of lower extremity or lumbar spine disease, were recruited for this study. The muscle onset time of erector spinae, gluteus maximus, and medial hamstring and angle of anterior pelvic tilt during hip extension in prone position were measured in two conditions: ADI maneuver condition and non-ADI maneuver condition. Muscle onset time was measured using a surface electromyography (EMG). Kinematic data for angle of anterior pelvic tilt were measured using a motion analysis system. The muscle onset time and angle of anterior pelvic tilt were compared using a paired t-test. The study showed that in ADI maneuver during hip extension in prone position, the muscle onset time for the erector spinae was delayed significantly by a mean of 43.20 ms (SD 43.12), and the onset time for the gluteus maximus preceded significantly by a mean of -4.83 ms (SD 14.10) compared to non-ADI maneuver condition (p<.05). The angle of anterior pelvic tilt was significantly lower in the ADI maneuver condition by a mean of 7.03 degrees (SD 2.59) compared to non-ADI maneuver condition (15.01 degrees) (p<.05). The findings of this study indicated that prone hip extension with the ADI maneuver was an effective method to recruit the gluteus maximus earlier than erector spinae and to decrease anterior pelvic tilting.

  • PDF

Effect of Pelvic Compression Belt on Abdominal Muscle Activity, Pelvic Rotation and Pelvic Tilt During Active Straight Leg Raise

  • Jo, Eun-young;An, Duk-hyun
    • Physical Therapy Korea
    • /
    • v.26 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Background: Uncontrolled lumbopelvic movement leads to asymmetric symptoms and causes pain in the lumbar and pelvic regions. So many patients have uncontrolled lumbopelvic movement. Passive support devices are used for unstable lumbopelvic patient. So, we need to understand that influence of passive support on lumbopelvic stability. It is important to examine that using the pelvic belt on abdominal muscle activity, pelvic rotation and pelvic tilt. Objects: This study observed abdominal muscle activity, pelvic rotation and tilt angles were compared during active straight leg raise (ASLR) with and without pelvic compression belt. Methods: Sixteen healthy women were participated in this study. ASRL with and without pelvic compression belt was performed for 5 sec, until their leg touched the target bar that was set 20 cm above the base. Surface electromyography was recorded from rectus abdominis (RA), internal oblique abdominis (IO), and external oblique abdominis (EO) bilaterally. And pelvic rotation and tilt angles were measured by motion capture system. Results: There were significantly less activities of left EO (p=.042), right EO (p=.031), left IO (p=.039), right IO (p=.019), left RA (p=.044), and right RA (p=.042) and a greater right pelvic rotation angle (p=.008) and anterior pelvic tilt angle (p<.001) during ASLR with pelvic compression belt. Conclusion: These results showed that abdominal activity was reduced while the right pelvic rotation angle and anterior pelvic tilt angle were increased during ASLR with a pelvic compression belt. In other words, although pelvic compression belt could support abdominal muscle activity, it would be difficult to control pelvic movement. So pelvic belt would not be useful for controlled ASLR.

Active Object Tracking using Image Mosaic Background

  • Jung, Young-Kee;Woo, Dong-Min
    • Journal of information and communication convergence engineering
    • /
    • v.2 no.1
    • /
    • pp.52-57
    • /
    • 2004
  • In this paper, we propose a panorama-based object tracking scheme for wide-view surveillance systems that can detect and track moving objects with a pan-tilt camera. A dynamic mosaic of the background is progressively integrated in a single image using the camera motion information. For the camera motion estimation, we calculate affine motion parameters for each frame sequentially with respect to its previous frame. The camera motion is robustly estimated on the background by discriminating between background and foreground regions. The modified block-based motion estimation is used to separate the background region. Each moving object is segmented by image subtraction from the mosaic background. The proposed tracking system has demonstrated good performance for several test video sequences.

Effect of Vision Coherent Sensory Cue on Roll Tilt Perception and Sensory Weighting (족부 진동 자극 유무에 따른 인체의 운동지각 변화 및 정량화)

  • Lim, Hye-Rim;Park, Su-Kyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.11
    • /
    • pp.1091-1097
    • /
    • 2012
  • Nowadays, some movie theaters provide additional sensory information in 3D movies to enhance visually induced motion perception. However, no studies have investigated how motion perception increases. Thus, in this study, we examined the effect of visual coherent sensory information on visually induced motion perception and quantification of sensory information. A visual stimulus rotated sinusoidally and visual coherent sensory information were applied as vibrations to a subject's foot. We measured the sway of the subject's body by using a force plate and somatosensory bar rotation that represents the subject's perception of the horizon using an encoder. By using this data, we obtained the weight of the sensory information using a Kalman filter. As a result, it was found that subjects rotated the somatosensory bar more when visual coherent vibrations were applied. The weight of vision also increased when visual coherent vibrations were applied. Thus, we can conclude that visual coherent sensory information tends to enhance visually induced motion perception and weight of vision.

Feature-based Object Tracking using an Active Camera (능동카메라를 이용한 특징기반의 물체추적)

  • 정영기;호요성
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.3
    • /
    • pp.694-701
    • /
    • 2004
  • In this paper, we proposed a feature-based tracking system that traces moving objects with a pan-tilt camera after separating the global motion of an active camera and the local motion of moving objects. The tracking system traces only the local motion of the comer features in the foreground objects by finding the block motions between two consecutive frames using a block-based motion estimation and eliminating the global motion from the block motions. For the robust estimation of the camera motion using only the background motion, we suggest a dominant motion extraction to classify the background motions from the block motions. We also propose an efficient clustering algorithm based on the attributes of motion trajectories of corner features to remove the motions of noise objects from the separated local motion. The proposed tracking system has demonstrated good performance for several test video sequences.