• Title/Summary/Keyword: thyroid imaging

Search Result 159, Processing Time 0.028 seconds

The Evaluation of Scattering Effects for Various Source Locations within a Phantom in Gamma Camera (감마카메라에서의 팬텀 내 선원 위치 변화에 따른 산란 영향 평가)

  • Yu, A-Ram;Lee, Young-Sub;Kim, Jin-Su;Kim, Kyeong-Min;Cheon, Gi-Jeong;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.216-224
    • /
    • 2009
  • $^{131}I$ is a radiological isotope being used widely for treatment of cancer as emitting gamma-ray and it is also applied to estimate the function of thyroid for its accumulation in thyroid. However, $^{131}I$ is more difficult to quantitate comapred to $^{99m}Tc$, because $^{131}I$ has multiple energy gamma-ray emissions compared to $^{99m}Tc$ which is a mono energetic gamma-ray source. Especially, scattered ray and septal penetration resulted by high energy gamma ray have a bad influence upon nuclear medicine image. The purpose of this study was to estimate scatter components depending on the different source locations within a phantom using Monte Carlo simulation (GATE). The simulation results were validated by comparing with the results of real experiments. Dual-head gamma camera (ECAM, Chicago, Illinois Siemens) with high energy, general-purpose, and parallel hole collimators (hole radius: 0.17 cm, septal thickness: 0.2 cm, length: 5.08 cm) was used in this experiment. The NaI crystal is $44.5{\times}59.1\;cm$ in height and width and 0.95 cm in thickness. The diameter and height of PMMA phantom were 16 cm and 15 cm, respectively. The images were acquired at 5 different locations of $^{131}I$ point source within the phantom and the images of $^{99m}Tc$ were also acquired for comparison purpose with low energy source. The simulation results indicated that the scattering was influenced by the location of source within a phantom. The scattering effects showed the same tendency in both simulation and actual experiment, and the results showed that the simulation was very adequate for further studies. The results supported that the simulation techniques may be used to generalize the scattering effects as a function of a point source location within a phantom.

  • PDF

Parathyroid Carcinoma (부갑상선암)

  • Cho Eun-Chol;Sub Jin-Hak;Chung Woong-Yun;Kim Ho-Geun;Park Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.17 no.2
    • /
    • pp.205-209
    • /
    • 2001
  • Purpose: Most cases of primary hyperparathyroidism are due to parathyroid adenoma or parathyroid hyperplasia. Parathyroid carcinoma is a very rare cause of hyperparathyroidism. Although the diagnosis of parathyroid carcinoma is usually established by pathologic criteria especially of vascular or capsular invasion, some clinical and biochemical features differentiate it from benign forms of hyperparathyroidism. We under-took a retrospective study in 6 patients with parathyroid carcinoma, with the aim of conveying experience from management for this rare cause of hyperparathyroidism. Methods: Clinical symptoms, biochemical laboratory, radiologic, and intraoperative findings, local recurrence and distant metastasis were analyzed in 6 patients diagnosed pathologically as a parathyroid carcinoma after operation from 1992 to 2001. Results: Mean age was 50.2 years (33.0-60.0 years) and male to female ratio was 1:1. Neck mass was found in 5 patients, multiple bone pain in 3 patients and renal stone in 1 patient. One case has suffered from chronic renal failure for 19 years. Although preoperative laboratory evaluations showed the aspects of hyperparathyroidism in all cases, mean serum calcium level was 11.2mg/dl(10.5-12.1mg/dl), slightly elevated. Laboratory values after surgery were within the normal range in 5 cases. However, in one case with chronic renal failure, serum PTH levels, serially checked, were above the normal range. Any of imaging methods failed to suggest a parathyroid carcinoma preoperatively. Parathyroid adenoma was suspected in 3 cases, thyroid cancer in the other cases before surgery. The extent of resection was radical resection of parathyroid lesion with more than unilateral thyroid lobectomy and central compartment neck node dissection and in 2 cases, the resection of recurrent laryngeal nerve or strap muscles was added. During follow-up period, any local or systemic recurrence were not evident in all the cases. Conclusion: Although parathyroid carcinoma is a rare disease and its preoperative diagnosis, in our experience, could not easily be made, the understanding of characteristic clinical and biochemical feature could help diagnosis at first surgery. Radical resection without remaining residual tumor is most important for the management of the parathyroid cancer.

  • PDF

Detection of Spinal Metastases: Comparison of Bone Scan and MR Imaging (전이성 척추 악성 종양의 진단 : 골스캔과 자기공명영상의 비교)

  • Kim, Ki-Jun;Sohn, Hyung-Sun;Park, Jeong-Mi;Chung, Soo-Kyo;Lee, Jae-Moon;Kim, Choon-Yul;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.384-390
    • /
    • 1994
  • Authors retrospectively compared the 99mTc MDP bone scans and corresponding MR imagings in 20 patients with histologically proven malignancy, Mean interval of the two studies was 16.6 days, Cancer diagnosis Included 8 lung, 2 each of colon, breast, stomach, 1 each of prostate, thyroid, malignant lymphoma and 3 adenocarcinoma of unknown primary site. Of the 105 regions compared, :t6 regions were positive for metastases in bone scans or MR imagings. 30 regions(65.2%) were positive by bone scan and 44 regions(95.7%) by MR imaging. 87 regions(82.9%) were concordantly positive or negative by bone scan and MR imaging, but 18 regions(17.1%) were discordant. In the discordant regions, 16 regions positive in MR imaging were negative in bone scan. The greatest number of discordant findings occured in the cervical region and in the patient with stomach cancer. Our results suggest that the sensitivity of MR Imaging is greater than that of bone scan in detecting spinal metastases. And bone scan is useful screening test of metastasis for evaluating entire skeleton including spine.

  • PDF

Absorbed and effective dose from spiral and computed tomography for the dental implant planning (치과 임프란트 치료 계획을 위한 나선형 일반 단층촬영과 전산화 단층촬영시 흡수선량 및 유효선량 평가)

  • Hong Beong-Hee;Han Won-Jeong;Kim Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.31 no.3
    • /
    • pp.165-173
    • /
    • 2001
  • Objectives : To evaluate the absorbed and effective doses of spiral and computed tomography for the dental implant planning. Materials and Methods: For radiographic projection, TLD chips were placed in 22 sites of humanoid phantom to record the exposure to skin and the mean absorbed dose to bone marrow, thyroid, pituitary, parotid and submandibular glands and nesophagus. Effective dose was calculated, using the method suggested by Frederiksen et al.. Patient situations of a single tooth gap in upper and lower midline region, edentulous maxilla and mandible were simulated for spiral tomography. 35 axial slices (maxilla) and 40 axial slices (mandible) with low and standard dose setting were used for computed tomography. All the radiographic procedures were repeated three times. Results: The mean effective dose in case of maxilla was 0.865 mSv, 0.452 mSv, 0.136 mSv and 0.025 mSv, in spiral tomography of complete edentulous maxilla, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). That in case of mandible was 0.614 mSv, 0.448 mSv, 0.137 mSv and 0.036 mSv, in spiral tomography of complete edentulous mandible, computed tomography with standard mAs, computed tomography with low mAs and spiral tomography of a single tooth gap (p<0.05). Conclusions: Based on these results, it can be concluded that low mAs computed tomography is recommended instead of spiral tomography for the complete edentulous maxilla and mandible dental implant treatment planning.

  • PDF

Attitude of the Korean dentists towards radiation safety and selection criteria

  • Lee, Byung-Do;Ludlow, John B.
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.179-184
    • /
    • 2013
  • Purpose: X-ray exposure should be clinically justified and each exposure should be expected to give patients benefits. Since dental radiographic examination is one of the most frequent radiological procedures, radiation hazard becomes an important public health concern. The purpose of this study was to investigate the attitude of Korean dentists about radiation safety and use of criteria for selecting the frequency and type of radiographic examinations. Materials and Methods: The study included 267 Korean dentists. Five questions related to radiation safety were asked of each of them. These questions were about factors associated with radiation protection of patients and operators including the use of radiographic selection criteria for intraoral radiographic procedures. Results: The frequency of prescription of routine radiographic examination (an example is a panoramic radiograph for screening process for occult disease) was 34.1%, while that of selective radiography was 64.0%. Dentists' discussion of radiation risk and benefit with patients was infrequent. More than half of the operators held the image receptor by themselves during intraoral radiographic examinations. Lead apron/thyroid collars for patient protection were used by fewer than 22% of dental offices. Rectangular collimation was utilized by fewer than 15% of dental offices. Conclusion: The majority of Korean dentists in the study did not practice radiation protection procedures which would be required to minimize exposure to unnecessary radiation for patients and dental professionals. Mandatory continuing professional education in radiation safety and development of Korean radiographic selection criteria is recommended.

Therapeutic Feasibility Study and Clinical Trial of Intrahepatic $I^{-131}-Lipiodol$ on Patients with Hepatocellular Carcinoma ($Lipiodol-I^{-131}$의 경간동맥 주입에 의한 간암치료의 가능성에 관한 연구)

  • Yoo, Hyung-Sik;Suh, Jung-Ho;Lee, Jong-Tae;Kim, Dong-Ik;Park, Chang-Yun;Kim, Byung-Soo;Park, Chan-H.;Thakur, M.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.2
    • /
    • pp.61-71
    • /
    • 1986
  • An iodized oil such as Ethiodol or Lipiodol was selectively retained in the tumor vessels of the large hepatomas as well as in the small daughter hepatomas for long periods following the intra-arterial hepatic injection of such contrast material. The specific aim of the study is to deliver a high internal radiation dose to hepatocellular carcinoma (HCC) in an attempt to control the disease. We were able to replace a small fraction of the stable iodine (I-127) of the 37% iodine in Lipiodol by the $I^{-131}$ with 100% exchange efficiency. $I^{-131}$ labeled Lipiodol was injected through the super-selected tumor feeding artery under superselection or into the proper hepatic arterial level of patients who have malignant hepatomas confirmed by aspiration cytology serum AFP and various imaging modalities. Clinical traial was performed on 43 cases during recent 6 months and follow-up observation was carried out. No severe complications or other adverse reactions were encountered until nowdays. $I^{-131}-Lipiodol$ was stable in vivo and no significant activity was noted in the thyroid, stomach, blood and urine after the injection. Only small fraction of radioisotope activity was noticed in the both side of lungs. Tumor to normal liver radio was very high. Therefore, $I^{-131}-Lipiodol$ (or P-32-Lipiodol) will be effective delivering high internal radiation dose to the tumor while delivering small radiation doses to normal tissues. Labeling, tumor dose calculation and preliminary findings will be presented.

  • PDF

Optimization of Inpatient Management of Radioiodine Treatment in Korea (우리나라에서 방사성옥소입원치료 관리 최적화)

  • Park, Min-Jae;Kim, Jung-Hyun;Jang, Jung-Chan;Kim, Chang-Ho;Jeong, Jae-Min;Lee, Dong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.261-266
    • /
    • 2008
  • We established a model to calculate radioactive waste from sewage disposal tank of hospitals to optimize the number of patients receiving inpatient radioiodine therapy within the safety guideline in our country. According to this model and calculation of radioactivity concentration using the number of patients per week, the treatment dose of radioiodine, the capacity and the number of sewage tanks and the daily amount of water waste per patient, estimated concentration of radioactivity in sewage waste upon disposal from disposal tanks after longterm retention were within the safety guideline (30 Bq/L) in all the hospitals examined. In addition to the fact that we could increase the number of patients in two thirds of hospitals, we found that the daily amount of waste water was the most important variable to allow the increase of the number of patients within the safety margin of disposed radioactivity. We propose that saving the water amount be led to increase the number of patients and they allow two patients in an already furnished hospital inpatient room to meet the increasing need of inpatient radioiodine treatment for thyroid cancer.

A Study on the Comparative Analysis of Images and Doses According to Tube Orientation During Anterior-Posterior Axial Projection Examination of the Skull (머리뼈 전-후 축 방향검사 시 Tube 방향설정에 따른 표면선량과 영상분석에 관한 연구)

  • Jeong, Sung-Hun;Yoo, Je-hyeon;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.301-306
    • /
    • 2021
  • The skull has peripheral organs such as the crystalline lens and thyroid gland, which are highly radiosensitive, but the examination is performed without considering the uneven dose distribution due to the heel effect at the time of the current Skull Town's examination. However, no studies have been conducted on the exposure dose of surrounding organ tissues due to the difference in image density due to the heel effect and the non-uniformity of the dose. Using the cathode (-) and anode (+) set on the Tube to measure the scattered radiation along the Tube direction as a guide, change 30° and 37° in the cathode direction and 30° and 37° in the anode direction. It was given and investigated 5 times to obtain scattered radiation. image measurements were SNR, PSNR, RMSE, and MAE. Measurement results Measurement results of surrounding organ doses when the Tube direction was 30° and 37° The dose was low when the direction was cathodic in all organs (p<0.000). Both cathodes were higher in the image measurements(p<0.04). Continuous research may be needed for diagnostically valuable imaging and minimization of patient exposure dose.

A Study on Radiation Dose and Image Quality according to CT Table Height in Brain CT (두부 CT 검사 시 테이블 높이에 따른 선량과 화질에 관한 연구)

  • Ki-Won Kim;Joo-Young Oh;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Kyung-Hwan Lim;Yun Yi
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.99-106
    • /
    • 2023
  • The height of the table should be considered important during computed tomography (CT) examination, but according to previous studies, not all radiology technologists set the table at the patient's center at the examination, which affects the exposure dose and image quality received by the patient. Therefore, this study intends to study the image quality exposure dose according to the height of the table to realize the optimal image quality and dose during the brain CT scan. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. For the exposure dose measurement, optically stimulated luminescence dosimeter (OSLD) was attached to the front, side, eye, and thyroid gland of the head phantom. In the signal to noise ratio (SNR) measurement result, The SNR values for each table height were all lower than 915 mm. As a result of exposure dose, the exposure dose on each area increased as the table height decreased. The height of the table has a close relationship with the patient's radiation exposure dose in the CT scan.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF