3개의 양방향 벅-부스트 컨버터를 이용한 3상 인버터 시스템 (Three Phase Inverter System Utilizing Three Bi-directional Buck-Boost Converter)

  • 김성영;남광희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.551-554
    • /
    • 2006
  • An inverter system which consists of three bi-directional buck-boost converters, is proposed for motor driving. Three phase sinusoidal output voltages can be generated by utilizing three buck-boost converters. The advantage of this scheme is that it does not require a separate DC-DC converter for motor driving, i.e. inverter function is combined into the three DC-DC converters. This topology is suitable for inverters for hybrid or fuel cell vehicles where DC link voltage is subject to change depending upon charging status or output power. So the proposed system is capable of driving motor at high speed. The converter system is controlled by PI controller and simulation results done by MATLAB SIMULINK are provided.Ҙ?⨀ሉȀ̀㘰々K䍄乍?ጊ츀Ѐ㔹〻Ԁ䭃䑎䴀

  • PDF

Simplified Control Scheme of Unified Power Quality Conditioner based on Three-phase Three-level (NPC) inverter to Mitigate Current Source Harmonics and Compensate All Voltage Disturbances

  • Salim, Chennai;Toufik, Benchouia Mohamed
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.544-558
    • /
    • 2013
  • This paper proposes a simplified and efficient control scheme for Unified Power Quality Conditioner (UPQC) based on three-level (NPC) inverter capable to mitigate source current harmonics and compensate all voltage disturbances perturbations such us, voltage sags, swells, unbalances and harmonics. The UPQC is designed by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The dc voltage is maintained constant using proportional integral voltage controller. The shunt and series AF are designed using a three-phase three-level (NPC) inverter. The synchronous reference frame (SRF) theory is used to get the reference signals for shunt and the power reactive theory (PQ) for a series APFs. The reference signals for the shunt and series APF are derived from the control algorithm and sensed signals are injected in tow controllers to generate switching signals for series and shunt APFs. The performance of proposed UPQC system is evaluated in terms of power factor correction and mitigation of voltage, current harmonics and all voltage disturbances compensation in three-phase, three-wire power system using MATLAB-Simulink software and SimPowerSystem Toolbox. The simulation results demonstrate that the proposed UPQC system can improve the power quality at the common connection point of the non-linear load.

2-레그 3상 PWM 인버터의 출력전압에서 직류링크 리플전압의 영향 보상 (Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-Leg Three-Phase PWM Inverters)

  • 김영신;이동춘;석줄기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, a simple scheme compensating for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, where single-phase half-bridge PWM convertor and two-leg inverter are used. The voltage at neutral point of the dc-link is controlled so that the upper-half of do-link voltage is equal to the lower-half voltage in average concept. However, the effect of the do-link ripple voltage results in the inverter output voltage and current distortion. This effect can be eliminated by introducing a compensation voltage in switching time calculation. Also, the inverter dead time should be compensated for sinusoidal output waveform. The proposed scheme has been verified by experimental results which were obtained from the V/F constant operation of the induction motor fed by two-leg inverter.

비용절감형 단상-삼상 전력변환기 구조의 해석 및 제어 (Analysis and Control of Cost-Effective Topologies for Single Phase to Three Phase Power Converter)

  • 이해춘;박태열;김기택
    • 산업기술연구
    • /
    • 제19권
    • /
    • pp.217-226
    • /
    • 1999
  • A single phase to three phase power converter with cost effective and simple structure is proposed. The converter consists of rectifier and inverter. The rectifier is composed of a half wave rectifier, a dc link capacitor, and a current limiting inductor, and the inverter is of only two switches with PWM control. For negative sequence operation the inverter output voltage leads the line input by $60^{\circ}$, and for positive sequence operation the inverter output voltage leads by $60^{\circ}$. We can see that positive sequence operation shows higher output voltage, slight harmonic distortion(2%), and better performances such as high efficiency and high power factor. A mathematical model for system analysis is provided, and specifications for selection and control scheme both for start-up and for steady state are analyzed. comparison and operational limits of positive and negative sequence operation are performed, and simulations and experiments are executed to verify the proposed.

  • PDF

태양광 발전시스템의 현장 운전특성 및 문제점 (A filed operation characteristics and the controversial point of Photovoltaic power generation system)

  • 고강훈;서기영;이현우;홍두성;강영철;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.381-383
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper presents a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL control system and the phase detector of interactive voltage by using da transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor. The results of the operated from January to October show the system characteristics.

  • PDF

Feasible Power Loss Analysis and Estimation of Auxiliary Resonant DC Link Assisted Soft-Switching Inverter with New Zero Vector Generation Method

  • Manabu Kurokawa;Claudio Y. Inaba;M. Rukonuzzaman;Eiji Hiraki;Yoshihiro Konishi;Mutsuo Nakaoka
    • Journal of Power Electronics
    • /
    • 제2권2호
    • /
    • pp.77-87
    • /
    • 2002
  • The purpose of this paper is to improve power conversion efficiency of three-phase soft-switching voltage-source inverter with an auxiliary resonant dc link (ARDCL) snubber circuit. Firstly, the operation principle of ARDCL snubber circuit is described. Secondly, this paper proposes an effictive generation method of zero voltage vector for three-phase voltage-source soft-switching inverter in power losses in which power losses in the ARDCL snubber circuit can be reduced. In particular, zero voltage holding interval in the inverter DC busline can be controlled due to the new generation scheme of zero voltage vector. Thirdly, a simulator for power loss analysis for power loss characteristics based on actual system, is developed. the validity of developed. The validity of developed simulator of proved with experimental results. Finally, power efficency of three-phase inverter is estimated according to high carrier frequency by using the simulatior.

Transformer-Less Single-Phase Four-Level Inverter for PV System Applications

  • Yousofi-Darmian, Saeed;Barakati, Seyed Masoud
    • Journal of Power Electronics
    • /
    • 제14권6호
    • /
    • pp.1233-1242
    • /
    • 2014
  • A new inverter topology for single-phase photovoltaic (PV) systems is proposed in this study. The proposed inverter offers a four-level voltage in its output terminals. This feature results in easier filtering in comparison with other conventional two-level or three-level inverters. In addition, the proposed four-level inverter (PFLI) has a transformer-less topology, which decreases the size, weight, and cost of the entire system and increases the overall efficiency of the system. Although the inverter is transformer-less, it produces a negligible leakage ground current (LGC), which makes this inverter suitable for PV grid-connected applications. The performance of the proposed inverter is compared with that of a four-level neutral point clamped inverter (FLNPCI). Theoretical analysis and computer simulations verify that the PFLI topology is superior to FLNPCI in terms of efficiency and suitability for use in PV transformer-less systems.

Design and Stability Analysis of a Fuzzy Adaptive SMC System for Three-Phase UPS Inverter

  • Naheem, Khawar;Choi, Young-Sik;Mwasilu, Francis;Choi, Han Ho;Jung, Jin-Woo
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.704-711
    • /
    • 2014
  • This paper proposes a combined fuzzy adaptive sliding-mode voltage controller (FASVC) for a three-phase UPS inverter. The proposed FASVC encapsulates two control terms: a fuzzy adaptive compensation control term, which solves the problem of parameter uncertainties, and a sliding-mode feedback control term, which stabilizes the error dynamics of the system. To extract precise load current information, the proposed method uses a conventional load current observer instead of current sensors. In addition, the stability of the proposed control scheme is fully guaranteed by using the Lyapunov stability theory. It is shown that the proposed FASVC can attain excellent voltage regulation features such as a fast dynamic response, low total harmonic distortion (THD), and a small steady-state error under sudden load disturbances, nonlinear loads, and unbalanced loads in the existence of the parameter uncertainties. Finally, experimental results are obtained from a prototype 1 kVA three-phase UPS inverter system via a TMS320F28335 DSP. A comparison of these results with those obtained from a conventional sliding-mode controller (SMC) confirms the superior transient and steady-state performances of the proposed control technique.

DC 오프셋 전류 주입에 의한 4-Switch 3-Phase Inverter의 커패시터 전압 불평형 보상 (Compensation of Unbalanced Capacitor Voltage for Four-switch Three-phase Inverter Using DC Offset Current Injection)

  • 박영주;손상훈;최익
    • 한국전자통신학회논문지
    • /
    • 제10권3호
    • /
    • pp.365-373
    • /
    • 2015
  • 기존 6스위치 3상 인버터(SSTPI)의 한 상을 스위치 대신 커패시터로 대체한 4스위치 3상 인버터(FSTPI)에서 양 커패시터 전압의 불평형에 의한 출력전압의 오차를 보상하는 것은 FSTPI의 성능을 결정하는 중요한 요소이다. 본 논문에서는 DC 오프셋 전류 주입에 의하여 FSTPI의 커패시터 전압 불평형을 보상하는 새로운 방법과 FSTPI에 적용할 수 있는 간략화된 SVPWM 방법을 제안한다. 제안된 방법은 컴퓨터 시뮬레이션을 통해 타당성을 검증하였다.

간략화 된 SVPWM을 적용한 4-Switch 3-Phase Inverter의 제어 방법 (Four-switch Three-phase Inverter control method applied by simplified Space Vector PWM)

  • 손상훈;박영주;최익
    • 한국전자통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.283-292
    • /
    • 2016
  • 6스위치 3상 인버터(SSTPI)의 한 상을 스위치 대신 커패시터로 대체한 4스위치 3상 인버터(FSTPI)에서 커패시터 전압의 불평형으로 인한 출력 전압의 오차를 보상하는 방법과 전압 제어 방법은 FSTPI의 성능을 결정짓는 중요한 요소이다. 본 논문에서는 DC 오프셋 전류 주입 통한 FSTPI의 커패시터 전압의 불평형을 보상하는 새로운 방법과 FSTPI의 새로운 전압 제어 방법인 간략화 된 SVPWM을 제안한다. 제안된 방법은 FSTPI로 SPMSM를 구동하는 시뮬레이션과 실험을 통해 그 타당성을 검증하였다.