• 제목/요약/키워드: three-phase inverter

검색결과 643건 처리시간 0.046초

A Study on Nonlinear Control Strategy for Three-phase Voltage Source PWM DC/AC Inverter based on the PCH Model

  • Mu, Xiaobin;Wang, Jiuhe;Bao, Xueyu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.53-57
    • /
    • 2012
  • The mathematical model of a three-phase voltage source pulse-width modulation (PWM) DC/AC inverter is non-linear, and in view of the traditional linear control strategy it can not meet the requirements of designing a high-performance inverter. What's more, when the loads are not pure resistive loads, the inverter further requires that the controller possess high-performance. This paper proposes a nonlinear control strategy for the inverter called Passivity-based Control. We can alter the inverter model in three-phase abc coordinate to two-phase synchronous rotating dq coordinate for establishing the port-control Hamiltonian (PCH) model for this system. We can control the distribution of energy in the system to achieve the control aim. Simulation results show that the passivity-based control method can make this system possess a level of high-performance that is both robust and dynamic.

단상 인버터로 구성된 3상 구형파 인버터의 고조파 저감기법에 관한 연구 (A Study on the Harmonic Reduction Technique in Three-Phase Square-Wave Inverters Formed by Single-Phase Inverters)

  • 조승연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.355-359
    • /
    • 2000
  • This paper deal with the harmonic reduction technique in three-phase square-wave inverter system formed by single-phase inverter. To reduce the harmonics six single-phase inverters are used for forming multi-phase inverter and zig-zag connected output transformer for eliminating the harmonic 6(2k-1)$\pm$1 orders. And an ac filter is furnished at output side. Computer simulations show that the THD of the output voltage can be reduced immensely.

  • PDF

계통연계 인버터의 주요 부하 불평형 시 상전류 제어를 통한 부하 상전압 평형 제어 (An Output Voltage Balance Control of Grid Connected Inverter by Phase Current Control at Critical Load Unbalanced Condition)

  • 박태현;김학원;조관열;민준기;최원일
    • 전력전자학회논문지
    • /
    • 제28권1호
    • /
    • pp.22-29
    • /
    • 2023
  • A grid-connected inverter can be used in grid-connected or stand-alone modes. Generally, a grid-connected inverter operates in a grid-connected mode, but the inverter operates in stand-alone mode if grid faults occur. In the stand-alone mode, the grid-connected inverter must supply electric power to a critical load that needs to receive stable power even though grid faults occur. Generally, three-phase loads are used as critical loads, but a single phase is configured in some cases. In these conditions, the critical load is required to unbalance the load power consumption, which makes the three-phase load voltage unbalancd. This unbalanced voltage problem can cause fatal problems to the three-phase critical loads, and thus must be addressed. Hence, this paper proposes an algorithm to solve this unbalanced voltage problem by the individual phase current control. The proposed method is verified using Psim simulation and experiments.

3상 계통연계 태양광발전시스템의 운전특성 (Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System)

  • 김영철;정명웅;서기영;이현우;우준인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권8호
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

2상 유도전동기 구동을 위한 2상 인버터 토폴로지의 비교 분석 (The Comparative Analysis of 2-Phase Inverter Topologies for 2-Phase Induction Motor)

  • 김동기;윤덕용
    • 전기학회논문지
    • /
    • 제65권6호
    • /
    • pp.1013-1018
    • /
    • 2016
  • In this paper, three kinds of the inverter topologies for the variable speed drive of 2-phase induction motor are compared and analyzed. The 2-phase inverters are classified into 2-leg, 3-leg, and 4-leg types depending on the number of power switching devices. And they use the output voltage vectors of the different forms according to the inverter topologies. Based on the comparative analyzed results, the effective values of output voltage have been defined by the linear modulation range. Therefore, the motor design guideline is proposed in order to decide a rated voltage of 2-phase induction motor according to the inverter topologies. Also, the computer simulations are carried out to verify the output voltage and current characteristics of each inverter topology.

Three Phase Voltage Source Soft Switching Inverter with High Frequency Pulse Current Transformers

  • Inaba, Claudio Y.;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제2권4호
    • /
    • pp.288-296
    • /
    • 2002
  • In this paper, a high frequency transformer - assisted auxiliary active resonant commutated snubber (HFTA-ARCS) for voltage source soft switching pulse width modulated power conversion circuits is presented. A three phase voltage source type soft switching inverter incorporating HFTA-ARCS circuits in its three bridge legs can reduce current rating of auxiliary active power switches and has sensorless simplified control scheme which any specified boost current management is not required for soft switching. Its operation principle and digital control scheme are described and a practical design method of circuit parameters on this HFTA-ARCS circuit is also introduced on the basis of computer simulation. Moreover, this space voltage vector modulated soft switching inverter system with DSP-based digital control scheme Is discussed and its effectiveness is proved on the basis of performance evaluations. The operating performances of this inverter system are also compared with those of conventional three-phase hard switching inverter under practical conditions of specified parameters.

정류방식에 따른 장치의 정확도와 출력 파형의 비교 (Comparison of Accuracy and Output Waveform of Devices According to Rectification Method)

  • 이인자
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

Design of a Hybrid Controller for the Three-phase Four-leg Voltage-source Inverter with Unbalanced Load

  • Doan, Van-Tuan;Kim, Ki-Young;Choi, Woojin;Kim, Dae-Wook
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.181-189
    • /
    • 2017
  • The three-phase four-leg voltage-source inverter topology is an interesting option for the three-phase four-wire system. With an additional leg, this topology can achieve superior performance under unbalanced and nonlinear load conditions. However, because of the low bandwidth of conventional controllers in high-power inverter applications, the system cannot guarantee a balanced output voltage under the unbalanced load condition. Most of the methods proposed to solve this problem mainly use the multiple synchronous frame method, which requires several controllers and a large amount of computation because of frame transformation. This study proposes a simple hybrid controller that combines proportional-integral (PI) and resonant controllers in the synchronous frame synchronized with the positive-sequence component of the output voltage of the three-phase four-leg inverter. The design procedure for the controller and the theoretical analysis are presented. The performance of the proposed method is verified by the experimental results and compared with that of the conventional PI controller.

전력용 MOSFET을 이용 삼상 정현파 PWM인버터의 변조신호에 관한 연구 (A study on Modulating signal for Three-phase sinusodial PWM Inverter using Power MOSFET)

  • 전희종;엄상오;문학룡;강범구
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1991년도 추계학술발표회논문집
    • /
    • pp.75-79
    • /
    • 1991
  • In this study, a new sinusoidal PWM inverter suitable for use with power MOSFETs is described. The output waveforms in the proposed OWM inverter are investigated both theoretically and experimentally. A modulating signal for the three-phase PWM inverter is obtained by adding 3nth harmonics to the conventional three-phase sine wave. By using the new modulating signal, the amplitude of the fundamental component is increased about 15 percent more than that of a conventional sine wave inverter and the commutation number of the inverter is decreased to two-thirds of a conventional one.

  • PDF

에너지 회생 방식 스너버 회로를 각는 3상 GTO PWM 인버터 (Three Phase GTO PWM Inverter Using the Energy Recovery Snubber Circuit)

  • 신병철;강경호;차재현;차득근;김명현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.255-259
    • /
    • 1998
  • This paper is proposed three phase GTO PWM Inverter with energy recovery snubber circuit. The proposed energy recovery snubber circuit effective in reduction of the power loss in the Inverter system than asymmetry GTO snubber circuit.

  • PDF