• Title/Summary/Keyword: three-phase inverter

Search Result 643, Processing Time 0.031 seconds

A Harmonic Elimination Method of PWM Inverter Using Walsh-Fourier Transform (Walsh-Fourier 변환을 사용한 PWM 인버어터의 고조파 제거 방법)

  • Ahn, Doo-Soo;Won, Chung-Yuen;Lee, Hae-Ki;Kim, Tae-Hoon;Kim, Hack-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.296-300
    • /
    • 1989
  • The paper proposes a method to eliminate harmonics of PWM inverter fed induction motor system using Walsh series. In other words, this paper presents technique of the selective harmonics elimination(SHE) by W-FT series in three phase PWM inverter output waveform. A microprocessor(8086 CPU) - controlled three phase induction motor system in order to verify this algorithm is present. It is designed for a three output voltage in the 1$\sim$60 Hz inverter with the 5th and 7th harmonics, 5th, 7th, 11th, and 13th, harmonics eliminated, and with the fundamental wave amplitude proportional to the output frequency. In the PWM inverter, dead time circuit is inserted in the switching si gnats to prevent the de link shortage. This paper is deals with quantative prediction of dead-time effect and its compensation in PWM inverters. The performance of the compensation circuits is confirmed by the experiment.

  • PDF

A Fault Tolerant Structure and Control Strategy for Electromagnetic Stirring Supplies

  • Li, Yan;Luo, An;Xiang, Xinxing;Chen, Yandong;He, Zhixing;Zhou, Fayun;Chen, Zhiyong
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1256-1267
    • /
    • 2017
  • A fault tolerant structure and its corresponding control strategy for electromagnetic stirring power supplies are proposed in this paper. The topology structure of the electromagnetic stirring power supply contains two-stages. The fore-stage is the PWM rectifier. The back-stage is the fault tolerant inverter, which is a two-phase three-bridge orthogonal inverter circuit while operating normally. When the power switch devices in the inverter are faulty, the structure of the inverter is reconfigured. The two-phase half bridge inverter circuit is constructed with the remaining power switch devices and DC-link capacitors to keep the system operating after cutting the faulty power switch devices from the system. The corresponding control strategy is proposed to let the system work under both normal and fault conditions. The reliability of the system is improved and the requirement of the electromagnetic stirring process is met. Finally, simulation and experimental results verify the feasibility of the proposed fault tolerant structure and corresponding control strategy.

Controller Design of Utility-connected Single-phase Inverter using d-q Theory (d-q이론을 이용한 개통 연계형 단상 인버터 제어기 설계기법)

  • Park, Chang-Joo;Kim, Chang-Hyun;Kim, Myung-Chul;Choi, Jae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1247-1249
    • /
    • 2003
  • Despite many advantages, d-q theory was available only for three phase system. But recently, some papers proposed the application methods of d-a theory or similar theories for single phase systems. This paper presents the control method of the utility-connected single-phase inverter using d-q theory. The suggested method gives single-phase system instantaneous controllability and also makes the realization of APF(Active Power Filter) without DFT operation and PFC(Power Factor Controller) possible. This paper deals with utility-connected single phase inverter with PFC function. The controller was verified by simulation tool.

  • PDF

DC-Link Voltage Unbalancing Compensation of Four-Switch Inverter for Three-Phase BLDC Motor Drive (3상 BLDC 전동기 구동을 위한 4-스위치 인버터의 DC-Link 전압 불평형 보상)

  • Park, Sang-Hoon;Yoon, Yong-Ho;Lee, Byoung-Kuk;Lee, Su-Won;Won, Chung-Yuen
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.391-396
    • /
    • 2009
  • In this paper, a control algorithm for DC-Link voltage unbalancing compensation of a four-switch inverter for a three-phase BLDC motor drive is proposed. Compared with a conventional six-switch inverter, the split source of the four-switch inverter can be obtained by splitting DC-link capacitor into two capacitors to drive the three phase BLDC motor. The voltages across each of two capacitors are not always equal in steady state because of the unbalance in the impedance of the DC-link capacitors $C_1$ and $C_2$ or the variable current flowed into the capacitor's neutral point in motor control. Despite the unbalance, if the BLDC motor may be run for a long time the voltage across one of the capacitors is more increased. So the unbalance in the capacitors voltages will be accelerated. As a result, The current ripple and torque ripple is increased due to the fluctuation of input current which flows into 3-phase BLDC motor. According to that, the vibration of motor will be increased and the whole system will be instable. This paper presents a control algorithm for DC-Link voltage unbalancing compensation. The sampling from the voltages across each of two capacitors is used to perform the voltage control of DC-Link by using the feedforward controller.

Simulation of Phase Unbalance and Power Factor Correction System (비상용발전기의 상불평형 및 역율보상기 시뮬레이션)

  • Shin, B.C.;Song, E.H.;Jeong, C.Y.;Kan, Y.;Cho, J.G.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.419-421
    • /
    • 1997
  • Three-phase system has many problems because of the unbalance load. So we propose two control algorithms using active power filter to dissolve these problems. One is three-leg inverter topology in which ac neutral line is connected directly to the midpoint of two series dc capacitors. The other is four-leg inverter topology in which ac neutral line is provided through a fourth leg. The three-phase unbalance is considered by connecting the load to one-phase. It is show that the proposed control algorithms give good performances.

  • PDF

A Study on the Three Phase Multi-PAM Inverter using the one-chip Microcomputer for UPS. (원칩 마이크로 컴퓨터를 이용한 UPS용 3상 다중 PAM 인버터에 관한 연구)

  • 김성백;이종규
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.2
    • /
    • pp.63-68
    • /
    • 1989
  • This paper discussed the Multi-PAM inverter for static power supply design. The controller part composed of one-chip microcomputer obtained control pattern simply. The configuration of termination part was composed of double bridge inverter and three-phase, three-winding transformer. The output waveforms using a controller and transformers synthesized the multi-PAM wave form by a voltage level of 22 steps per one-cycle. The output waveforms using the Low Pass Filter approximated to the sine wave.

  • PDF

High Performance Adjustable-Speed Induction Motor Drive System Incorporating Sensorless Vector Controlled PWM Inverter with Auto-Tuning Machine-Operated Parameter Estimation Schemes

  • Soshin, Koji;Okamura, Yukiniko;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.99-114
    • /
    • 2003
  • This paper presents a feasible development on a highly accurate quick response adjustable speed drive implementation fur general purpose induction motor which operates on the basis of sensorless slip frequency type vector controlled sine-wave PWM inverter with an automatic tuning machine parameter estimation schemes. In the first place, the sensorless vector control theory on the three-phase voltage source-fed inverter induction motor drive system is developed in slip frequency based vector control principle. In particular, the essential procedure and considerations to measure and estimate the exact stator and rotor circuit parameters of general purpose induction motor are discussed under its operating conditions. The speed regulation characteristics of induction motor operated by the three-phase voltage-fed type current controlled PWM inverter using IGBT's is illustrated and evaluated fur machine parameter variations under the actual conditions of low frequency and high frequency operations for the load torque. In the second place, the variable speed induction motor drive system, employing sensorless vector control scheme which is based on three -phase high frequency carrier PWM inverter with automatic toning estimation schemes of the temperature -dependent and -independent machine circuit parameters, is practically implemented using DSP-based controller. Finally, the dynamic speed response performances for largely changed load torque disturbances as well as steady state speed vs. torque characteristics of this induction motor control implementation are illustrated and discussed from an experimental point of view.

A Study on the Multi-level PV-PCS Using Cascade 3-Phase Transformer (직렬형 3상 변압기를 이용한 다중레벨 PV-PCS)

  • Kim, Ki-Seon;Song, Sung-Geun;Cho, Su-Eog;Choi, Joon-Ho;Kim, Kwang-Heon;Park, Sung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2359-2369
    • /
    • 2009
  • The study on the multi-level inverter has been increasingly progressing to reduce the switching loss and improve the THD of output current in photovoltaic inverter. Recently, the main topics of multi-level inverter are to reduce the number of devices maintaining the power quality. Therefore, the novel topology was proposed for these problem which is composed of the isolated H-bridge multi-level inverter using the three phase low frequency transformer. The proposed multi-level inverter may not be need for a independent DC power, diode and capacitor. Specially, It has a advantage in generating high voltage source. The proposed approach is verified through simulation and experiment.

Two-Switch Auxiliary Resonant DC Link Snubber-Assisted Three-Phase Soft Switching PWM Sinewave Power Conversion System with Minimized Commutation Power Losses

  • Nagai, Shinichiro;Sato, Shinji;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • This paper presents a high-efficient and cost effective three-phase AC/DC-DC/AC power conversion system with a single two-switch type active Auxiliary Resonant DC Link (ARDCL) snubber circuit, which can minimize the total power dissipation. The active ARDCL snubber circuit is proposed in this paper and its unique features are described. Its operation principle in steady-state is discussed for the three phase AC/DC-DC/AC converter, which is composed of PWM rectifier as power factor correction (PFC) converter, sinewave PWM inverter. In the presented power converter system not only three-phase AC/DC PWM rectifier but also three-phase DC/AC inverter can achieve the stable ZVS commutation for all the power semiconductor devices. It is proved that the proposed three-phase AC/DC-DC/AC converter system is more effective and acceptable than the previous from the cost viewpoint and high efficient consideration. In addition, the proposed two-switch type active auxiliary ARDCL snubber circuit can reduce the peak value of the resonant inductor injection current in order to maximize total system actual efficiency by using the improved DSP based control scheme. Moreover the proposed active auxiliary two-switch ARDCL snubber circuit has the merit so that there is no need to use any sensing devices to detect the voltage and current in the ARDCL sunbber circuit for realizing soft-switching operation. This three-phase AC/DC-DC/AC converter system developed for UPS can achieve the 1.8% higher efficiency and 20dB lower conduction noise than those of the conventional three-phase hard-switching PWM AC/DC-DC/AC converter system. It is proved that actual efficiency of the proposed three-phase AC/DC-DC/AC converter system operating under a condition of soft switching is 88.7% under 10kw output power.

Implementation of a High Efficiency Grid-Tied Multi-Level Photovoltaic Power Conditioning System Using Phase Shifted H-Bridge Modules

  • Lee, Jong-Pil;Min, Byung-Duk;Yoo, Dong-Wook
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.296-303
    • /
    • 2013
  • This paper proposes a high efficiency three-phase cascaded phase shifted H-bridge multi-level inverter without DC/DC converters for grid-tied multi string photovoltaic (PV) applications. The cascaded H-bridge topology is suitable for PV applications since each PV module can act as a separate DC source for each cascaded H-bridge module. The proposed phase shifted H-bridge multi-level topology offers advantages such as operation at a lower switching frequency and a lower current ripple when compared to conventional two level topologies. It is also shown that low ripple sinusoidal current waveforms are generated with a unity power factor. The control algorithm permits the independent control of each DC link voltage with a maximum power point for each string of PV modules. The use of the controller area network (CAN) communication protocol for H-bridge multi-level inverters, along with localized PWM generation and PV voltage regulation are implemented. It is also shown that the expansion and modularization capabilities of the H-bridge modules are improved since the individual inverter modules operate more independently. The proposed topology is implemented for a three phase 240kW multi-level PV power conditioning system (PCS) which has 40kW H-bridge modules. The experimental results show that the proposed topology has good performance.