• Title/Summary/Keyword: three-electrode system

Search Result 194, Processing Time 0.107 seconds

경정맥(經靜脈) 내적(內的) Pacemaker 이식후(移植後) 발생(發生)한 복잡한 감염합병증(感染合?症)의 1치험례(治驗例) (Complicated Wound Infection Following Transvenous Endocardial Pacemaker)

  • 이두연;윤여준;조범구;홍승록
    • Journal of Chest Surgery
    • /
    • 제9권2호
    • /
    • pp.265-270
    • /
    • 1976
  • Implantation of a permanent pacemaker is a widely accepted procedure for the patient with complete heart block.As a result of these device, the prognosis for patients with Adams-Stokes syndrome caused by complete A-V block and other cardiac arrhythmia have become much more optimistic. Permanent pacemaker implantation by means of a transvenous approach has made the operative risk much less and the procedure simpler. However, a number of complications have been reported in the literature regarding transvenous endocardial pacemaker implantation during the last a decade. The patient presented in this paper is a 26-year old girl who was implanted with a permanent pacemaker at 14 years of age because of a congenital A-V block. Following first exchange of pulse generator, the electrode (lead) was fractured, so that by the pulse generator, a change to the transvenous technique of implantation was made, After this, there were episodes of recurrent wound infection on three occasions, even though the site of pulse generator implantation was exchanged to the contralateral side of chest wall, massive doses of antibiotics were administered and sensitivity tests for coagulase positive staphylococcal infection were performed. Though there was no definite evidence of blood stream infection by blood culture, we decided not to use the transvenous technique and not to implant the pulse generator in the chest wall because the venous system and the entire anterior chest wall appeared to be diseased or contaminated by virulent pyogenic organisms. Finally this intractable systemic and local wound infection was successfully controlled by myocardial lead implantation via a subxiphoid approach and implantation of the pulse generator far down in the abdominal wall. The causes and routes of recurrent wound infection and possible blood born infection in this particular patient are still obscure. We strongly believe that myocardial pacemaker implantation is much safer than transvenous endocardial pacemaker implantation & myocardial pacemaker implantation is a definite method for controlling such an intractable wound infection. following transvenous pacemaker implantation.

  • PDF

Sphingomyelin과 Polyamic Acid의 농도 변화에 대한 단분자 LB막의 전기화학적 특성에 관한 연구 (A Study on the Electrochemical Properties of Langmuir-Blodgett Monolayer Film for the Changes of Concentration with Polyamic Acid and Sphingomyelin Mixture)

  • 박근호
    • 한국응용과학기술학회지
    • /
    • 제30권4호
    • /
    • pp.754-760
    • /
    • 2013
  • 순환전압전류법에 의한 인지질(sphingomyelin, SP)과 polyamic acid(PAA) 혼합물의 농도(몰비 1:1, 2:1 및 3:1)를 변화시켜 혼합단분자 LB막에 대한 전기화학적 특성을 조사하였다. SP과 PAA 혼합물의 단분자 LB막은 ITO glass에 LB법을 사용하여 제막하였다. 전기화학적 특성은 $KClO_4$ 용액에서 3 전극 시스템으로 측정하였다. 측정 범위는 연속적으로 1650 mV로 산화시키고, 초기 전위인 -1350 mV로 환원시켰다. 주사속도는 각각 50~250 mV/s로 설정하였다. 그 결과 SP와 PAA 혼합물의 LB막은 순환전압전류도표로부터 환원전류로 인한 비가역공정으로 나타났다. 혼합물 LB막의 혼합(SP:PAA) 몰비가 1:1, 2:1 및 3:1에서 확산계수(D)는 각각 $2.670{\times}10^{-5}$, $3.562{\times}10^{-5}$$1.005{\times}10^{-5}cm^2s^{-1}$을 얻었다.

페이퍼 에레크트로포레시스에 關한 硏究 (제1보) 계란단백의 移動度에 關하여 (Studies on the Paper Electrophoresis, I On the Mobility of Egg Albumin(Ovalbumin))

  • 장세헌;김시중
    • 대한화학회지
    • /
    • 제4권1호
    • /
    • pp.1-6
    • /
    • 1957
  • The mobilities and the electrophoretic phenomena of human serum albumin, and of horse serum albumin, etc., on paper were reported, but there is no information about the mobility and the electrophoretic phenomena of ovalbumin. In this study they are determined and considered at various time durations. The mean value of this mobility is compared with the value determined by the electrophoresis in solution. Also, the mobilities of the electroendosmotic flow, which affect on the mobility seriously, are determined at various time durations. Apparatus and method used, are a closed system type and a method with electrode vessels. It is concluded that: 1) The mobilities of ovalbumin have the nearly constant mobilities at six and eight hours of time durations, but it decreases at ten hours of long time duration. Their mean value is (0.243 ${\pm}$ 0.003)cm./hr./v./cm. toward anode at pH 8.0. 2) Under these experimental conditions, ovalbumin cannot be separated into three fractions (A1, A2, A3) on paper. 3) Most of the factors, which affect on the mobility, are fixed by the initial experimental conditions, but the electroendosmotic flow due to the characteristic capillarity of paper is measured. Then, the mean value of its mobilities shows the good constancy, and the value is (0.073 ${\pm}$ 0.0003)cm/hr./v./cm. toward cathode at pH 8.0. 4) By the above facts, if the same paper and the same experimental conditions are chosen, it may be preferred to determine the mobility of the electroendosmotic flow once time, even when many observations are required.

  • PDF

중준위 조사선량율 측정용 전리함의 설계 및 특성 (A Fabrication and Properties of Ionization Chamber Using Madium Exposure Rate)

  • 우홍;김성환;강희동
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.29-40
    • /
    • 1996
  • 조사선량율 5mR/h 이상에서 동작하는 원통형 전리함을 설계ㆍ제작하고 상용의 전류계를 이용하여 전하수집 특성을 조사하였다. 전리함은 전체 길이 15.5cm, 직경 5.22cm인 원통형이고 활성체적은 190.4㎤이다. 전리함의 전극은 벽면, 중심축 및 보호전극으로 구성하고, 이들을 동심축상에 배치하여 바탕전류가 8.39$\times$$10^{-14}$ $\pm$1.5$\times$$10^{-15}$ A이 되게 하였다. 전리함에 인가된 전입이 400V일 때 Cs$^{137}$에 대하여 99.7%의 수집효율을 보였으며, 상용의 선량계와 비교한 결과 교정정수 4.531$\times$19$^{7}$ R/C를 구하였다. 에너지 응답특성은 Cs$^{137}$ 을 1로 하였을 때 Am$^{241}$과 Co$^{60}$ 는 각각 1.30, 1.05로 나타났다. 방사선이 전리함의 측면으로 입사할 경우 입사방향에 따른 응답특성의 차이는 무시할 수 있었다.

  • PDF

Fuel Cell End Plates: A review

  • Kim, Ji-Seok;Park, Jeong-Bin;Kim, Yun-Mi;Ahn, Sung-Hoon;Sun, Hee-Young;Kim, Kyung-Hoon;Song, Tae-Won
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권1호
    • /
    • pp.39-46
    • /
    • 2008
  • The end plates of fuel cell assemblies are used to fasten the inner stacks, reduce the contact pressure, and provide a seal between Membrane-Electrode Assemblies (MEAs). They therefore require sufficient mechanical strength to withstand the tightening pressure, light weight to obtain high energy densities, and stable chemical/electrochemical properties, as well as provide electrical insulation. The design criteria for end plates can be divided into three parts: the material, connecting method, and shape. In the past, end plates were made from metals such as aluminum, titanium, and stainless steel alloys, but due to corrosion problems, thermal losses, and their excessive weight, alternative materials such as plastics have been considered. Composite materials consisting of combinations of two or more materials have also been proposed for end plates to enhance their mechanical strength. Tie-rods have been traditionally used to connect end plates, but since the number of connecting parts has increased, resulting in assembly difficulties, new types of connectors have been contemplated. Ideas such as adding reinforcement or flat plates, or using bands or boxes to replace tie-rods have been proposed. Typical end plates are rectangular or cylindrical solid plates. To minimize the weight and provide a uniform pressure distribution, new concepts such as ribbed-, bomb-, or bow-shaped plates have been considered. Even though end plates were not an issue in fuel cell system designs in the past, they now provide a great challenge for designers. Changes in the materials, connecting methods, and shapes of an end plate allow us to achieve lighter, stronger end plates, resulting in more efficient fuel cell systems.

셀프 피트니스 의류 개발을 위한 근전도 센싱 위치 연구 (A Study of Sensing Locations for Self-fitness Clothing base on EMG Measurement)

  • 조하경;조상우
    • 한국의류산업학회지
    • /
    • 제18권6호
    • /
    • pp.755-765
    • /
    • 2016
  • Recently, interest in monitoring health and sports is growing because of the emphasis on wellness, which is accelerating the development and commercialization of smart clothing for biosignal monitoring. In addition to exerciseeffect monitoring clothing that tracks heart rate and respiration, recently developed clothing makes it possible to monitor muscle balance using electromyogram (EMG). The electrode for EMG have to attached to an accurate location in order to obtain high-quality signals in surface EMG measurement. Therefore, this study develops monitoring clothing suitable for different types of human bodies and aims to extract suitable range of EMG according to movements in order to develop self-fitness monitoring clothing based on EMG measurement. This study identified and attached electrodes on six upper muscles and two lower muscles of ten males in their 20s. After selecting six main motions that create a load on muscles, the 8-ch wireless EMG system was used to measure amplitude value, noise, SNR and SNR (dB) in each part and statistical analysis was conducted using SPSS 20.0. As a result, the suitable range for EMG measurement to apply to clothing was identified as four parts in musculus pectoralis major; three parts in muscle rectus abdominis, two parts each in shoulder muscles, backbone erector, biceps brachii, triceps brachii, and musculus biceps femoris; and four part in quadriceps muscle of thigh. This was depicted diagrammatically on clothing, and the EMG-monitoring sensing locations were presented for development of self-fitness monitoring.

스테아르산과 인지질 혼합물의 농도변화에 대한 유기초박막의 안정성에 관한 연구 (A Study on the Stability of Ultra-Thin Film Mixed with Stearic Acid and Phospholipid)

  • 박근호
    • 한국응용과학기술학회지
    • /
    • 제32권4호
    • /
    • pp.789-794
    • /
    • 2015
  • 스테아르산과 인지질혼합물의 농도변화에 띠르는 유기초박막에 대한 안정성을 조사하였다. 스테아르산과 인지질 혼합물 유기초박막은 ITO glass에 LB법을 사용하여 제막하였다. 전기화학적 특성은 $NaClO_4$ 용액에서 3 전극 시스템으로 순환전압전류법을 사용하여 초기 1650 mV에서 최종 퍼텐셜 -1350 mV 까지 측정하였다. 그 결과 스테아르산과 인지질의 혼합물 유기초막은 순환전압전류도표로부터 산화전류로 인한 비가역공정으로 나타났다. 스테아르산과 인지질혼합물 LB막(몰비 1:1, 1:2, 1:3)에서 확산계수(D)는 $0.01N\;NaClO_4$에서 각각 $1.4{\times}10^{-3}$, $1.7{\times}10^{-3}$$1.6{\times}10^{-3}(cm^2/s)$로 산출되었다.

인지질(Sphingomyelin)과 Polyamic Acid 혼합물의 단분자 LB막의 전기화학적 특성에 관한 연구 (A Study on the Electrochemical Properties of Langmuir-Blodgett Monolayer Film Mixed with Polyamic Acid and Sphingomyelin)

  • 박근호
    • 한국응용과학기술학회지
    • /
    • 제30권1호
    • /
    • pp.64-70
    • /
    • 2013
  • 우리는 순환전압전류법에 의한 인지질(sphingomyelin)과 polyamic acid 혼합물의 단분자 LB막에 대한 전기화학적 특성을 조사하였다. Sphingomyelin과 polyamic acid 혼합물의 단분자 LB막은 ITO glass에 LB법을 사용하여 제막하였다. 전기화학적 특성은 $KClO_4$ 용액에서 3 전극 시스템으로 측정하였다. 측정 범위는 연속적으로 1650 mV로 산화시키고, 초기 전위인 -1350 mV로 환원시켰다. 주사속도는 각각 50, 100, 150, 200 및 250 mV/s로 설정하였다. 그 결과 sphingomyelin과 polyamic acid 혼합물의 LB막은 순환전압전류도표로부터 환원전류로 인한 비가역공정으로 나타났다. Sphingomyelin과 polyamic acid 혼합물 LB막에서 전해질농도가 0.1N과 0.2N에서 확산계수(D)는 각각 $2.67cm^2s^{-1}{\times}10^5$$5.23cm^2s^{-1}{\times}10^6$을 얻었다.

입자의 크기가 다른 아연공기전지용 아연음극의 부식에 관한 전기화학적 특성 연구 (Electrochemical Properties for the Corrosion of Zinc Anode with Different Particle Size and Shape in Zinc/air Batteries)

  • 양원근;홍정의;오례경;오지우;공영민;류광선
    • 한국분말재료학회지
    • /
    • 제20권3호
    • /
    • pp.186-190
    • /
    • 2013
  • The electrochemical performance for the corrosion of zinc anodes according to particle size and shape as anode in Zn/air batteries was study. We prepared five samples of Zn powder with different particle size and morphology. For analysis the particle size of theme, we measured particle size analysis (PSA). As the result, sample (e) had smaller particle size with $10.334{\mu}m$ than others. For measuring the electrochemical performance of them, we measured the cyclic voltammetry and linear polarization in three electrode system (half-cell). For measuring the morphology change of them before and after cyclic voltammetry, we measured Field Emission Scanning Electron Microscope (FE-SEM). From the cyclic voltammetry, as the zinc powder had small size, we knew that it had large diffusion coefficient. From the linear polarization, as the zinc powder had small size, it was a good state with high polarization resistance as anode in Zn/air batteries. From the SEM images, the particle size had increased due to the dendrite formation after cyclic voltammetry. Therefore, the sample (e) with small size would have the best electrochemical performance between these samples.

RF/DC 마그네트론 스퍼터로 제조한 NiInZnO/Ag/NiInZnO 다층박막의 Ag 금속 삽입층 두께 변화에 따른 특성 연구 (A Study on the Characteristics of NiInZnO/Ag/NiInZnO Multilayer Thin Films Deposited by RF/DC Magnetron Sputter According to the Thickness of Ag Insertion Layer)

  • 김남호;김은미;허기석;여인선
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2014-2018
    • /
    • 2016
  • Transparent, conductive electrode films, showing the particular characteristics of good conductivity and high transparency, are of considerable research interest because of their potential for use in opto-electronic applications, such as smart window, photovoltaic cells and flat panel displays. Multilayer transparent electrodes, having a much lower electrical resistance than widely-used transparent conducting oxide electrodes, were prepared by using RF/DC magnetron sputtering system. The multilayer structure consisted of three layers, [NiInZnO(NIZO)/Ag/NIZO]. The optical and electrical properties of the multilayered NIZO/Ag/NIZO structure were investigated in relation to the thickness of each layer. The optical and electrical characteristics of multilayer structures have been investigated as a function of the Ag and NIZO film thickness. High-quality transparent conductive films have been obtained, with sheet resistance of $9.8{\Omega}/sq$ for Ag film thickness of 8 nm. Also the multilayer films of inserted Ag 8 nm thickness showed a high optical transmittance above 93% in the visible range. The electrical and optical properties of the new multilayer films were mainly dependent on the thickness of Ag insertion layer.