• Title/Summary/Keyword: three phase ratio

Search Result 497, Processing Time 0.029 seconds

Intermittent Atomization Characteristics of Multi-Hole and Single-Hole Diesel Nozzle

  • Lee, Jeekuen;Kang, Shin-Jae;Park, Byungjoon
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.12
    • /
    • pp.1693-1701
    • /
    • 2002
  • The intermittent spray characteristics of a multi-hole and a single-hole diesel nozzle were experimentally investigated. The hole number of the multi-hole nozzle was 5, and the hole diameter of the 5-hole and the single-hole nozzle was the same as d$\_$n/=0.32 ㎜ with the constant hole length to diameter ratio(l$\_$n//d$\_$n/=2.81). The droplet diameters of the spray, including the time-resolved droplet diameter, SMD (Sauter mean diameter) and AMD (arithmetic mean diameter) , injected intermittently from the two nozzles into the still ambient were measured by using a 2-D PDPA (phase Doppler particle analyzer). Through the time-resolved evolutions of the droplet diameter, it was found that the structure of the multi-hole and the single-hole nozzle spray consisted of the three main parts : (a) the leading edge affected by surrounding air. and composed of small droplets; (b) the central part surrounded by the leading edge and mixing flow region and scarcely affected by the resistance of air, (c) the trailing edge formed by the passage of the central part. The SMD decreases gradually with the increase in the radial distance, and the constant value is obtained at the outer region of the radial distance (normalized by hole diameter) of 7-8 and 6 for the 5-hole and single-hole nozzle, respectively. The SMD along the centerline of the spray decrease shapely with the increase in the axial distance after showing the maximum value near the nozzle tip. The SMD remains the constant value near the axial distance(normalized by hole diameter) of 150 and 180 for the 5-hole and the single-hole nozzle, respectively.

Implementation and Performance Analysis of PLC Scheme based on SISO/MIMO-OFDM using MRC (최대비 합성법을 이용한 SISO/MIMO-OFDM 기반 전력선 통신 방식 구현 및 성능분석)

  • Yoo, Jeong-Hwa;Choe, Sang-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.2B
    • /
    • pp.176-183
    • /
    • 2011
  • In this paper, we propose the implementation and performance analysis of power line communication based on SISO/MIMO-OFDM which focuses on high speed data transmission in smart grid and future power line grid. We employ Zimmermann frequency model and Middleton Class A model as the multipath power line fading channel and impulse noise channel, respectively. In this paper, in order to improve the three-phase or single-phase PLC performance, we introduce a new MRC (called a&f-MRC) which effectively sums up multiple antenna diversity gain and multipath fading diversity gain. Via simulation, we prove the performance advantage over existing SISO/MIMO systems. In addition, we offer the tradeoff on system design through comparing with MRC, EGC and SC.

Sanitary Characterization of Commercial Boiled-dried Pacific Herring Clupea pallasi and Boiled-dried Anchovy Engraulis japonicus and Proposal of Quality Standards (시판 마른청어(Clupea pallasi) 및 마른멸치(Engraulis japonicus)의 위생 특성 비교 및 품질기준 제시)

  • Kang, Sang In;Lee, Su Gwang;Kim, Yong Jung;Kim, Min Joo;Park, Sun Young;Heu, Min-Soo;Kim, Jin-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.5
    • /
    • pp.604-613
    • /
    • 2015
  • The objective of this study was to estimate the food quality of commercial boiled-dried Pacific herring Clupea pallasi as a substitute for boiled-dried anchovy. Standards for controlling quality of boiled-dried Pacific herring were suggested based on international (US FDA and CODEX) and domestic (Korean FDA, Standards on Quality of Seafood and Seafood Products, KS) standards for boiled-dried anchovy. The standards included requirements for moisture [less than 30% (less than 35 in very tiny sizes)], water activity (less than 0.85), salinity (less than 10%), water-phase salt (less than 20%), acid-insoluble ash (less than 1.5%), yeast and mold (fewer than 1.0×103 CFU/g), and different size and breakage (less than 5%). Based on the standards suggested, commercial boiled-dried Pacific herring passed nine levels (all levels) in water activity, acid-insoluble ash, mold and yeast concentrations; seven levels (L-1, 2, 3, 4, M-1, 2, S) in water-phase salt, and three levels (L-1, 3, 4) in the ratio of different size and breakage categories. These results suggest that the quality of commercial boiled-dried Pacific herring is similar to that of commercial boiled-dried anchovy.

Mechanical Properties and Microstructure of the Leucite-Reinforced Glass-Ceramics for Dental CAD/CAM

  • Byeon, Seon-Mi;Song, Jae-Joo
    • Journal of dental hygiene science
    • /
    • v.18 no.1
    • /
    • pp.42-49
    • /
    • 2018
  • The computer-aided design/computer-aided manufacturing (CAD/CAM) system was introduced to shorten the production time of all-ceramic restorations and the number of patient visits. Among these types of ceramic for dental CAD/CAM, they have been processed into inlay, onlay, and crown shapes using leucite-reinforced glass-ceramics to improve strength. The purpose of this study was to observe the mechanical properties and microstructure of leucite-reinforced glass-ceramics for dental CAD/CAM. Two types of leucite-reinforced glass-ceramic blocks (IPS Empress CAD, Rosetta BM) were prepared with diameter of 13 mm and thickness of 1 mm. Biaxial flexural testing was conducted using a piston-on-three-ball method at a crosshead speed of 0.5 mm/min. Weibull statistics were used for the analysis of biaxial flexural strength. Fracture toughness was obtained using an indentation fracture method. Specimens were observed by field emission scanning electron microscopy to examine the microstructure of the leucite crystalline phase after acid etching with 0.5% hydrofluoric acid aqueous solution for 1 minute. The results of strength testing showed that IPS Empress CAD had a mean value of $158.1{\pm}8.6MPa$ and Rosetta BM of $172.3{\pm}8.3MPa$. The fracture toughness results showed that IPS Empress CAD had a mean value of $1.28{\pm}0.19MPa{\cdot}m^{1/2}$ and Rosetta BM of $1.38{\pm}0.12MPa{\cdot}m^{1/2}$. The Rosetta BM sample exhibited higher strength and fracture toughness. Moreover, the crystalline phase size and ratio were increased in the Rosetta BM sample. The above results are expected to elucidate the basic mechanical properties and crystal structure characteristics of IPS Empress CAD and Rosetta BM. Additionally, they will help develop leucite-reinforced glass-ceramic materials for CAD/CAM.

Vertical Vibration Decrease Effect of Slab in Shear-Wall Structures According to Property and Size of Structural Members (전단벽식 공동주택의 부재 물성치 및 크기 변화에 따른 슬래브 수직진동 저감 효과)

  • Chun Ho-Min;Yoo Seung-Min
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.61-69
    • /
    • 2006
  • Vertical vibrations on the slab of buildings are affected by types of vibration sources, transfer paths, and the material property and the size of members. Among these parameters, the vibration sources and the transfer path can not be controlled, but the property and the size of members can be controlled in the phase of design the members. In this study, the vibration responses according to the property and size of members were obtained by using a prediction program based on dynamic-stiffness matrix. Three parameters which are not usually considered as major factors for architecral planning were selected fur these analyses. They are the strength of materials, the thickness of wall and the thickness of slab. The ground vibration source located near a building was used as vibration input data in the analyses. This study has its originality on presenting appropriate property and size of structural members in order to reduce vertical vibration of slab in shear-wall structures. Analysing the results from the vibration estimation program according to the variations of parameters, the appropriate ratio among the sizes of structural members were proposed. From these results, the vibration level on the slab which is not constructed yet would be predicted and the vibration peak level can be reduced or shifted into the desirable frequency range. Therefore, the vertical vibration could be controlled in the phase of designing buildings.

A Study on Radiographic Equipments and Situation for the Chest (흉부(胸部)의 X선촬영(線撮影) 및 촬영장치(撮影裝置) 현황(現況)에 관(關)한 조사(調査))

  • Ko, Shin-Gwan;An, Bong-Seon
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.3-9
    • /
    • 1985
  • From the study on the chest radiologic equipments and situations of university hospitals, general hospitals, and radiologic clinics located in Seoul area and Choong-cheong province, the author got conclusions as follows : 1. The rectfication methods of the equipments were employing mainly single or three-phase full wave, and 78% of the examined were using single phase full wave. 2. The focal sizes in case of small focus were less than 1.0mm in chest-only use, and more than 1.0mm in 81% of combined use. The focal sizes in case of large focus were more than 1.6mm in 78% of the total. 3. Maximum ratings of x-ray tubes were 47% at 125 kVp maximum tube voltage and 41% at 150kVp. The maximum tube currentes higher than 500mA were shown in 72% of all the examined. And the maximum exposure time was the range of 5-8sec. 4. Grid was not used in the 66% of all the hospitals. Equipment for chest-only was employing 10:1 grid ratio and the 2.0-2.9mmAl of total filtration formed 38% of all the examined. 5. In the processing time of exposed film, 68% of all was 90sec, and only 20% of all the examined used optimum developing temperature according to this condition. 6. In the radiographic conditions, more than 50% used low tube voltages lower than 70 kVp and only 3% of all the equipments used high tube voltages higher than 100 kVp. The 46.9% of all the equipments 300mA, and 53% of all used shorter exposure time less than 1/20(0.05) sec. 7. In the monthly average number of radiographs, 44% of all was x-ray the radiographs.

  • PDF

Novel SAW-based pressure sensor on $41^{\circ}YX\;LiNbO_3$ ($41^{\circ}YX\;LiNbO_3$ 기반 SAW 압력센서 개발)

  • Wang, Wen;Lee, Kee-Keun;Hwang, Jung-Soo;Kim, Gen-Young;Yang, Sang-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.1 s.343
    • /
    • pp.33-40
    • /
    • 2006
  • This paper presents a novel surface acoustic wave (SAW)-based pressure sensor, which is composed of single phase unidirectional transducer (SPUDT), three reflectors, and a deep etched substrate for bonding underneath the diaphragm. Using the coupling of modes (COM) theory, the SAW device was simulated, and the optimized design parameters were extracted. Finite Element Methods (FEM) was utilized to calculate the bending and stress/strain distribution on the diaphragm under a given pressure. Using extracted optimal design parameters, a 440 MHz reflective delay line on 41o YX LiNbO3 was developed. High S/N ratio, shan reflection peaks, and small spurious peaks were observed. The measured S11 results showed a good agreement with simulated results obtained from coupling-of-modes (COM) modeling and Finite Element Method (FEM) analysis.

Nutrient Intake and Utilization by Range Managed Sheep in Critical Physiological Stages Maintained on Grazing with Concentrate Supplementation in a Hot Semi-Arid Environment

  • Karim, S.A.;Santra, A.;Sharma, V.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.9
    • /
    • pp.1228-1234
    • /
    • 2000
  • The reported study was conducted on range managed Malpura ewes that were non-breeding empty, were at an advanced stage of pregnancy, and were in early lactation, under a protocol of free grazing with concentrate supplementation at 1.00, 1.25 and 1.50% of their body weight to assess their plane of nutrition and nutrient intake. The biomass yield of pasture plots was 1689, 1820 and 2912 kg/ha in pregnancy, lactation and empty phases, respectively. In addition to natural shrubs and forbs, Cenchrus ciliaris (36.4%) and dead litter (31.6%) were the major component of pasture vegetation during pregnancy. The dead litter disappeared during the lactation and empty phase with a concomitant increase in distribution of Cenchrus ciliaris to 73.0 and 87.2% respectively. The daily dry matter consumption from supplemental concentrate and free grazing was 70.1, 57.3 and 63.5 g/kg $W^{0.75}/d$ with concentrate to roughage ratio of 40:60, 47:53 and 33:67 in pregnancy, lactation and empty phases respectively. Digestibility of DM and OM were similar in the three phases while CP digestibility was higher (p<0.0l) during lactation than other two phases. Digestibility of NDF, ADF and cellulose were higher (p<0.0l) in empty than pregnancy and lactation, while hemicellulose digestibility was similar in lactation and empty and lower in pregnancy phase. The ewes in ~hases of pregnancy, lactation and empty consumed 7.1, 7.7 and 6.1 g DCP and 197.2, 214.6 and 232.5 kcal DE/kg $W^{0.75}/d$ respectively. It is concluded that ewes maintained on semi-arid Cenchrus dominated pasture with concentrate supplementation during pregnancy, lactation and empty phases consumed 45.2, 45.1 and 35.2 g DCP/Mcal ME respectively.

Stripping of Ferric Chloride by Mineral Acid Solution from the Loaded Alamine336 Phase (Alamine336에 추출(抽出)된 염화(鹽化) 제 2철(鐵)의 무기산용액(無機酸溶液)에 의한 탈거(奪去))

  • Lee, Man-Seung;Chae, Jong-Gwee
    • Resources Recycling
    • /
    • v.17 no.5
    • /
    • pp.37-43
    • /
    • 2008
  • Stripping experiments of iron from the loaded Alamine336 by sulfurous, chloric and sulfuric acid solutions have been performed by varying the concentration of acid and stripping conditions. The stripping percentage of iron decreased with the increase of HCl and $H_{2}SO_4$ concentration, while that increased with the increase of $H_{2}SO_3$ concentration up to 3 M. Stripping temperature had adverse effect on the stripping percentage of iron in the stripping by $H_{2}SO_3$ solution, while the stripping percentage of iron by HCl solution increased with the increase of temperature. Stripping isotherm of iron by 0.1 M HCl and 0.1 M $H_{2}SO_4$ solution indicated that three and four stripping stages could result in a solution containing 0.05 M iron at an O/A ratio of 1/10 from the loaded Alamine336 phase where iron concentration was 0.5 M.

Efficiency Questions of the Left-turn Prohibit in Case of 4-Leg Intersections with 5-Phase Signal System (5현시 신호체계 4지교차로의 좌회전 금지에 따른 효율성 분석)

  • 변상철;박병호
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.4
    • /
    • pp.91-106
    • /
    • 1996
  • This paper deals with on the efficiency questions of the left-turn prohibit at an isolated intersection and a corridor with 5-phase signal system. Its objectives are three-fold ; (1) to analyze the efficiency of the left-turn prohibit with the use of an imaginary network, (2) to evaluate various factors under consideration in decision making on the left-turn prohibit, (3) to provide a framework for estimating and evaluating overall impacts of the left-turn prohibit in traffic network. the major findings using an imaginary network and computer packages such as MINUTP, TRANSYT-7F and STATGRAPH are followings. First, left-turn prohibit reduces cycle length by 33 seconds and delay time per vehicle by 36 seconds at an isolated intersection, and cycle length by 31 seconds and delay time per veicle by 43 seconds along a corridor. Second, total vehicle mile of travel and total travel time at an isolated intersection seem up to increase 38.85 miles(57.36km), 14.4 hour on the average, Regarding to a corridor, total vehicle mile of travel is increased by 50.14 miles(80.22km), but total travel time is decreased by129.9 hours. Third, the efficiency of left-turn prohibit are affected the following eight factors including left-turn volume(veh/hr) and ratio(%), average delay time per vehicle(sec/veh) and others. Finally, several simple and multiple regression models to evaluate the impacts on the left-turn prohibit are formulated from the above eight factors. It can be expected that these models will take an important role in decision-making of left-turn prohibit.

  • PDF